D. GRAY KIMEL

D. GRAY KIMEL is a 1982 towing vessel. The Coast Guard has recorded 50 inspections since 1993, most recently in September 2025, along with 29 deficiencies and 21 casualty investigations between 2002 and 2022.

Records from 1993 to 2025. Most recent: inspection, 8 September 2025.

Built
1982
Last inspected
8 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 8 September 2025
…with no type recorded32
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ9768
212216
Flag
UNITED STATES
Maury page id
psix-212216

Documentation record

Registered dimensions (L × B × D)66.5 ft × 26.0 ft × 8.7 ft
Registered tonnagegross 141 / net 96
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEASTERN MARINE, INC. · PANAMA CITY, FL, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it141 - Regulatory (Subpart C or D), Gross Ton
96 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 17

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

YORK Freight Barge · MISLE 1727791 · 15 May 2022 · activity 7452602WICOMICO Freight Barge · MISLE 419064 · 24 February 2022 · activity 7402925RAPPAHANNOCK Freight Barge · MISLE 1711630 · 14 December 2021 · activity 7377508NI Freight Barge · MISLE 1489839 · 17 May 2021 · activity 7199006UNDOCUMENTED BARGE Freight Barge · MISLE 1665437 · 17 May 2021 · activity 7199006NANTICOKE Freight Barge · MISLE 465049 · 19 April 2020 · activity 6941793ELIZABETH Freight Barge · MISLE 74776 · 20 December 2019 · activity 6877187CAPTAIN HANK Towing Vessel · MISLE 172599 · 20 December 2019 · activity 6877187WICOMICO Freight Barge · MISLE 419064 · 20 December 2013 · activity 4773266SC-214 Freight Barge · MISLE 54745 · 27 July 2012 · activity 4409364RAPPAHANNOCK Freight Barge · MISLE 610248 · 27 July 2012 · activity 4409364POTOMAC Freight Barge · MISLE 419063 · 29 March 2012 · activity 4274364RAPPAHANNOCK Freight Barge · MISLE 610248 · 14 March 2012 · activity 4264421NANTICOKE Freight Barge · MISLE 465049 · 9 October 2010 · activity 3867108CHOPTANK Freight Barge · MISLE 934644 · 18 July 2008 · activity 3274577PATAPSCO Freight Barge · MISLE 462384 · 5 November 2007 · activity 3093810218 Freight Barge · MISLE 870812 · 14 January 2007 · activity 2857372BARGE #4 Freight Barge · MISLE 455903 · 28 May 2002 · activity 1621953BARGE # 216 Freight Barge · MISLE 729011 · 28 May 2002 · activity 1621953WEEKS 105 Freight Barge · MISLE 237320 · 7 October 1993 · activity 149821

Inspection history · 50

8 September 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8229595
19 August 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7970505
9 July 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7949830
11 December 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7838565
1 November 2023 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7818853
5 October 2023 In-Service Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7805918
14 October 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7580242
15 May 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7452602
24 February 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7402925
14 December 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7377508
18 October 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7359353
15 September 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7313745
18 August 2021 Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7290297
30 July 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7272438
30 July 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7272839
17 May 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7199006
19 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7037413
19 April 2020 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6941793
20 December 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6877187
30 January 2019 Deficiency Check · Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6617206
12 October 2017 Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6289563
3 February 2014 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4794557
20 December 2013 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4773266
27 July 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4409364
29 March 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4274364
14 March 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4264421
16 November 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4189945
28 July 2011 Industry Initiated Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4102658
9 October 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3867108
13 December 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3650727
7 August 2009 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3560960
20 March 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3492938
22 January 2009 Type not recorded
No type recorded · Station Portsmouth · USCG East District (CGD-E) · Activity 3398487
14 January 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3431056
18 July 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3274577
29 April 2008 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3194984
5 November 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3093810
17 January 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2857244
14 January 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2857372
5 January 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2851965
17 October 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2810758
20 February 2006 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2624795
14 February 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2632023
28 May 2002 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1621953
22 April 2002 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1816420
23 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 160834
29 May 1997 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 161764
8 January 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 61097
7 October 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 149821
1 October 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 58125

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical equipment must be marked with its respective current and voltage ratings. The wires running to and from the starboard generator to the battery are not marked with their approval information or current/voltage rating. In addition the outer insulator is cracked and damaged posing a potential electrical hazard. Install new wires in accordance with the standards outlined in 46 CFR 143.575 or alternatively in 46 CFR 143.580. 46 CFR 143.400
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
Resolution: Wires replaced with USCG approved wire.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 September 2025 Resolved
Each crew berthing area shall be equipped with information regarding procedures and resources to report crimes, including sexual assault and sexual harassment, including information on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard. Vessel does not have posters instructing to report sexual harassment/assault directly to USCG. Provide posters that specifically instruct victims to report incidents directly to USCG by means as stated. 46 U.S.C. 11101(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 9 October 2025
Resolution: Recieved photos of posted SASH posters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel's shaft seal was found excessively leaking water, the crew was able to immediately tighten seal. 46 CFR 143.205
Action required: 10 - Deficiency Rectified
Resolved 8 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 9 July 2024 Resolved
10138 - A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated. The system must:(1) Have an alarm in the pilothouse distinct from any other alarm;(2) Require action from the master or officer in charge of a navigational watch, during an interval not to exceed 10 minutes, in order to reset the alarm timer; and(3) Immediately (within 30 seconds) notify another crewmember if the pilothouse alarm is not acknowledged. The vessel does not have a pilothouse alerter system installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2024
Resolution: BNWAS was installed when the vessel first entered drydock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 November 2023 Resolved
The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. There was no heat detector alert at the operating station. 46 CFR 142.330 (a)(3) 60c
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2023
Resolved 16 November 2023
Resolution: Serviced by third party company; attended vessel and re-tested heat detector over the starboard engine. Verified audible and visual on the panel on the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 November 2023 Resolved
A power-driven vessel when towing astern shall exhibit: two masthead lights in vertical line, sidelights,and two towing lights in a vertical line. Two of the stern lights and port side light were inoperable. Prior to restricted visibility or night operations. 33 CFR 83.24 (c)(ii)(iii) 705c
Action required: 705 - Other - as specified
Due 1 November 2023
Resolved 16 November 2023
Resolution: Witnessed proper operation of the two stern lights and port side navigations lights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2023 Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures. Fire extinguisher in engine room, had a broken discharge horn. 46 CFR 142.240(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 16 November 2023
Resolution: Verified third party company replaced the horn in kind on the portable fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 1 November 2023 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Navigation assessment, in accordance with § 140.635. There was no record of Navigation assessments. Captain stated they were done verbally. 46 CFR 140.915(a)(6) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 11 December 2023
Resolution: Recieved objective evidence of logs being completed, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 November 2023 Resolved
Equipment, cargo, and industrial components on board the tow are properly secured and made ready for transit. Spill kit not secured to deck. 46 CFR 140.805 (b) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Witnessed spill kit secured to the bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2023 Resolved
Multi-outlet adapters (power strips) may not be connected to other adapters (“daisy-chained”), or otherwise used in a manner that could overload the capacity of a receptacle. Galley and wheelhouse had multi-outlet adapters in use. 46 CFR 143.575(c) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Verified the galley and bridge outlet adapters were removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 1 November 2023 Resolved
Means must be provided for stopping each fan to a ventilation system machinery spaces and for closing, in case of fire. The vent cover for the starboard intake, had a corroded hole in the cover. 46 CFR 144.605 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Verified a new cover was fitted and welded onto the vent opening.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2023 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes. CO2 Instruction placard was deteriorated and illegible. 46 CFR 76.15-10(h) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Verified renewed sign installed; verified both had the same part number for the system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2023 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Main fuel shut off valve for all components was inoperable. 46 CFR 143.260(b) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Witnessed proper operation of the renewed remote fuel shut-off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Hard fuel lines on both engines were installed with broken supports, total of 12 supports broken between port and stbd MDE. 46 CFR 143.205(a) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: Verified new supports were installed in-kind on port and starboard main engines.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 November 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. High bilge level alarm in the aft section of the engine room was inoperable. 46 CFR 143.230(a)(5) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2023
Resolved 16 November 2023
Resolution: The space is equipped with two bilge high level alarms and only required one. This duplicate was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 November 2023 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Fresh water tank gasket leaking into Engine room. 46 CFR 140.510(a)(2) 10c
Action required: 10 - Deficiency Rectified
Due 1 November 2023
Resolved 1 November 2023
Resolution: Crew tightened the bolts on the hatch; securing the leak.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2023 Resolved
Each lifebuoy with a floating electric water light must have a lanyard, secured around the body of the lifebuoy. Light not attached to body of lifebuoy. 46 CFR 141.360(c)(4) 10c
Action required: 10 - Deficiency Rectified
Due 1 November 2023
Resolved 1 November 2023
Resolution: Witnessed crew connect the light around the body of the ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 November 2023 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Excessive amount of oil and water discovered on top of engine block in the vicinity of intake turbo of starboard MDE. 46 CFR 143.205(c)(1) 10c
Action required: 10 - Deficiency Rectified
Due 1 November 2023
Resolved 1 November 2023
Resolution: Witnessed the crew clean up the excessive oily water mixtures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 July 2021 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel experienced a loss of the main generator due to coolant leak. Completed repair will be observed and cleared by a Marine Inspector from this office prior to departure of next port of call.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2021
Resolution: Visually inspected engine replacement and verify replacement in kind.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 August 2020 Resolved
Any towing vessel with alternating watches or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. Post emergency duties and duty stations for all crew members to the satisfaction of the Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 14 October 2022
Resolution: Cleared during annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 August 2020 Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets and immersion suits must be carried so that a lifejacket and an immersion suit is immediately available for persons at each normally manned watch station. Vessel was missing 01 lifejacket and 01 immersion suit. No additional persons may be onboard other than crew until lifejacket and immersion suit are provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 August 2020
Resolution: Coast Guard marine inspector received evidence of new life jacket and immersion suit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2019 Resolved
Fire pump was unable to deliver water from both hoses at 50 PSI. The pump delivered water at 40 PSI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 29 July 2019
Resolution: Witnessed testing of newly installed f/p.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 January 2019 Resolved
Fuel transfer pump not mounted permantently in engine room
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2019
Resolved 10 June 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2019 Resolved
Low level alarm on day tank must be visable and audible at each operating station
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 29 July 2019
Resolution: Witnessed testing of newly installed low level alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 January 2019 Resolved
Generator power supply indicator bulbs are both out
Condition: Improper/Lack of Maintenance
Due 10 July 2019
Resolved 29 July 2019
Resolution: Witnessed testing of indicator bulbs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2019 Resolved
Machinery & Electrical systems must be designed and maintained for saftey of vessel and crew, plastic zip ties are used for bundling solely verses metal
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 29 July 2019
Resolution: Inpsected un-supported cabling and all plastic ties were replaced with metal banding.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 April 2008 Resolved
Record keeping- Company did not do DOT required background check in the past on new employees, representative DER at the audit was under the impression that having new employees take a pre-employment drug test fulfilled the requirements. Was told by DAPI that all employees need to have a background check done who were there latest hires.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcan’s, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 April 2008 Resolved
EAP Requirements- Training is required for Supervisory positions on the Vessel. Supervisor receive 1 hour EAP training needed.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcans, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 April 2008 Resolved
Company did show proof of Alcohol Testing Kits. DER and Safety person showed a sample of a drug Testing kit that would be used for a serious marine incident testing, not incompliance with the applicable regulations.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcans, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.

Casualty record · 21

22 April 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1816420
28 May 2002Routine · role: Involved in a Marine Casualty · activity 1621953
17 October 2006Routine · role: Involved in a Marine Casualty · activity 2810758
14 January 2007Routine · role: Involved in a Marine Casualty · activity 2857372
17 January 2007Routine · role: Involved in a Marine Casualty · activity 2857244
5 November 2007Routine · role: Involved in a Marine Casualty · activity 3093810
18 July 2008Routine · role: Involved in a Marine Casualty · activity 3274577
14 January 2009Routine · role: Involved in a Marine Casualty · activity 3431056
13 December 2009Routine · role: Involved in a Marine Casualty · activity 3650727
9 October 2010Routine · role: Involved in a Marine Casualty · activity 3867108
16 November 2011Routine · role: Involved in a Marine Casualty · activity 4189945
27 July 2012Routine · role: Involved in a Marine Casualty · activity 4409364
20 December 2013Routine · role: Involved in a Marine Casualty · activity 4773266
3 February 2014Routine · role: Involved in a Marine Casualty · activity 4794557
20 December 2019Routine · role: Transiting Vicinity of Primary Subject · activity 6877187
19 April 2020Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6941793
17 May 2021Routine · role: Involved in a Marine Casualty · activity 7199006
30 July 2021Routine · role: Involved in a Marine Casualty · activity 7272839
14 December 2021Routine · role: Involved in a Marine Casualty · activity 7377508
24 February 2022Routine · role: Involved in a Marine Casualty · activity 7402925
15 May 2022Routine · role: Sighted in Area · serious marine incident, as classified · 1 injured · activity 7452602
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

NIGHT FALCON (2002–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.