MAURY USCG vessel records
← All vessels

SIGNET WARHORSE III

Built
2001
Last inspected
12 June 2026
Controls
None recorded without a removal date
Also recorded as
DOLPHIN III (2004)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 12 June 2026
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2002–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8967577
WDH4883
Flag
UNITED STATES
Tonnage
1108 - Convention (Subpart B), Gross Ton 299 - Regulatory (Subpart C or D), Gross Ton 332 - Convention (Subpart B), Net Ton 203 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-33161
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

SIGNET WARHORSE I Towing Vessel · MISLE 585078 · 6 December 2025 · activity 8279997SIGNET WARHORSE I Towing Vessel · MISLE 585078 · 4 December 2025 · activity 8299986

Inspection history · 43

12 June 2026 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8402896
1 June 2026 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8385421
28 May 2026 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8382772
6 December 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8279287
6 December 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8279997
4 December 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8299986
21 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8272293
20 February 2025 ISM Oversight
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8082071
24 October 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8024244
13 August 2024 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7979592
25 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7942552
25 June 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7960488
15 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7912892
19 April 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7898459
19 April 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7898487
26 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7855987
16 March 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7651875
15 March 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7651331
1 February 2023 ISM SMC Audit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7630485
12 September 2022 MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7571114
13 July 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7255410
19 August 2020 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 7043178
22 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942521
27 September 2019 Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6835060
16 August 2019 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6785183
25 April 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6686458
4 January 2018 MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6332354
3 January 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6332982
9 October 2014 Administration · MARPOL · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5000692
11 July 2014 Administration · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4918709
10 December 2012 Deficiency Check · Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4499375
22 March 2010 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3700330
29 September 2009 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3600397
23 July 2009 MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3542727
6 February 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3413464
19 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3382691
22 December 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2274265
22 December 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2279845
10 August 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2161907
10 August 2004 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2318818
17 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2070543
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978416
25 February 2002 Uninspected Towing Vessel
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489078

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2026 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation AND be suitable for route and service; Sector Jacksonville was notified that the exhaust manifold was glowing red due to the number 4 fuel injector, injecting excessive smoke from the exhaust on both engines. Vessel is required tugs while entering/leaving the port and must remain at the pier until a satisfactory inspection is complete.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2026
Resolved 1 June 2026
Resolution: Installed 10 new fuel injectors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2025 Resolved
Machinery must be maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The Port Main Engine is out of service due to failed cylinder head assemblies on the #5,#9, and #8 cylinders.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2025
Resolution: Port MDE Repaired; replaced #5, #8, and #9, head assemblies. ABS has witnessed a satisfactory operational test and cleared condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel had a low frequency on the number 1 SSDG while it was supplying power to the vessel. Shutdown caused a temporary loss of power until the E-Gen started. Discovered debris in the f/o filter, changed filter and generator operation was restored with no issues. 46 CFR 143.205 (a) Code 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 April 2024
Resolution: Corrected
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 5 January 2009 Resolved
-Per Reg 33 CFR 151.26(b)(6), Appendix A of the SOPEP must be revised to include an updated version of the NOCP List for International Operations, Annex 2. -All references to Regulation 26 of Annex I, must be changed to reference Regulation 37 of Annex I of the International Convention for the Prevention of Pollution from Ships.
Due 5 February 2009
Resolved 1 June 2009
Resolution: Deficiencies addressed and SOPEP amended accordingly. SOPEP expires 07/25/2011.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.