Inspection history · 101
19 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7991259
7 November 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7821688
15 December 2021
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7368843
5 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7072074
15 July 2020
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7008756
2 March 2020
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919303
10 February 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6908128
12 August 2019
In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6782909
18 July 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6754430
7 May 2019
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6678857
30 April 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6674330
23 April 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6668643
27 March 2019
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6650883
25 August 2017
MARPOL Annex VI Survey · Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · MARPOL Annex II Examination · COI Inspection · Cargo Tank Internal · MTSA/ISPS Verification · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6251093
28 December 2016
MARPOL Annex VI Survey · Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6063085
5 January 2016
MTSA Verification · MARPOL Annex VI Survey · Periodic Inspection · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5791539
24 December 2014
Annual Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5043482
31 October 2014
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5013388
3 January 2014
MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4775456
4 September 2012
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4432057
2 November 2011
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4179567
5 October 2011
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4160840
21 December 2010
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3915035
22 November 2010
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3896270
15 July 2010
MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3796496
9 February 2010
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3677664
7 October 2008
MARPOL Annex I Examination · Annual Inspection · MTSA Verification · Administrative Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3340217
7 December 2006
MARPOL Annex I Examination · Construction Oversight · Internal Structural Exam · MTSA Verification · Administrative Inspection · Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2835963
11 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743970
16 February 2006
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2586368
3 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578842
27 December 2005
Annual Inspection · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2556639
8 December 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2548784
18 October 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2516943
4 October 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2507292
10 September 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2489993
11 March 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2308332
13 February 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2292256
12 October 2004
MARPOL Annex V Examination · MARPOL Annex I Examination · MTSA Verification · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2218774
15 September 2004
Hull Examination · Internal Structural Exam · Deficiency Check · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2196150
27 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2079856
9 May 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2063961
6 February 2004
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection · Administrative Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2001575
8 January 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1979994
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962289
24 November 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1953633
24 November 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1954795
7 November 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1943689
4 February 2003
MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1732841
4 November 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1702601
6 September 2002
In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1672854
3 July 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1640740
17 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1632987
6 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613381
16 April 2002
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1608099
21 March 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495901
5 March 2002
Internal Structural Exam · Deficiency Check · Hull Examination · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1491131
9 January 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477747
7 November 2001
MARPOL Annex V Examination · MARPOL Annex I Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1370400
29 August 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 518094
28 June 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1450647
27 June 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1067768
26 June 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1604461
21 November 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1056071
20 November 2000
MARPOL Annex V Examination · Re-Inspection · Damage Survey · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384607
22 October 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 453613
28 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 465800
1 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 153329
2 February 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432255
19 November 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456774
21 September 1999
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031514
20 September 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 157151
7 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 486940
22 January 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1122780
17 December 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 437411
24 September 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519949
21 July 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 499788
26 November 1997
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1111052
23 October 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 197487
23 October 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 472899
23 October 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 753480
13 November 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 539384
22 October 1996
Examination of Repairs · Damage Survey · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380676
11 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414703
6 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102888
16 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 436254
10 February 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 188344
5 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 518183
11 December 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363477
30 November 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463204
30 May 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 517146
13 February 1995
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155245
12 October 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 671303
23 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 122089
6 February 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1165109
1 December 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849381
27 January 1993
Deficiency Check · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1132941
21 January 1993
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444696
13 December 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 953031
1 March 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1232759
21 December 1989
Initial Construction-Excluding Oversight · Construction Oversight · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232746
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 October 2020
Resolved
To maintain a valid Certificate of Inspection (COI), you must complete your annual and periodic inspections within the periods specified... and your COI must be endorsed. The vessel was issued a COI on 17DEC2018 to expire 17DEC2023. An annual inspection of the vessel was due between 17SEP2019 and 17MAR2020. The vessel has failed to conduct the annual inspection within the required inspection period and therefore the COI is invalid. A new COI examination shall be conducted prior to carriage of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2020
Resolved 22 April 2026
Resolution: Vessel in laid up status
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
Resolved
Vessels that operate in salt water must be inspected in accordance with the intervals set forth in table 31.10-21(a). The vessel was required to complete two (2) internal structural examinations (ISE) within a five (5) year period, with no more than three (3) years between any two examinations. The vessel completed an ISE on 31OCT2014 and 17DEC2018, with an ISE being due 31OCT2019. The vessel failed to conduct the ISE as required. An ISE shall be conducted prior to carriage of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2020
Resolved 7 July 2026
Resolution: Vessel in laid-up status
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 7 May 2019
Resolved
Each transfer relief valve must open at the pressure at which it is set to open. Two caro pump relief valves were unable to sustaion their desired set pressure at 125psi. Repair or replace relief valves and retest prior to using cargo pumps #1 & #4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2019
Resolution: Reviewed test certs of Safety Relief Valves & found satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 April 2019
Resolved
46 CFR 35.35-70(b): Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at pressure they are set to open. 04 Cargo pump relief valves were found without clear markings and testing documentation (annual) could not be provided. PRIOR TO DISCHARGE documentation shall be provided to verify annual testing of all cargo Pump relief valves.
Action required: 705 - Other - as specified
Resolved 7 May 2019
Resolution: Witnessed sat bench test of 2 relief valves. remain two valves failed test. Issued new 835. See AN: 6678857
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 April 2019
Resolved
46 CFR 39.2001(j): each vessel vapor connection flange face must have a permanent stud projecting outward at top of flange face. Stud was found to be broken and not permanently mounted.
Prior to using port side Vapor connection stud must be permanantly installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2019
Resolved 24 September 2019
Resolution: see narrative
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 March 2019
Resolved
Manned tank barges and tankships authorized to carry Grade A, B, C, D liquids at any temperature or Grade E liquids at elevated temperatures shall be provided with a combustible gas indicator suitable for determining the presence of explosive concentrations of the cargo carried. New systems were found onboard but installation was not complete and system was inoperable. Complete installation IAW manufacturer’s instructions and demonstrate proper operation to the satisfaction of the attending OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2019
Resolved 18 July 2019
Resolution: The vessel has portable detection devices onboard and meets all requirements as set forth in 46 cfr 35.30-15 and is able to conduct operations with current Gas detection practices and equipment. The system in question is optional and is an addition to es
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 March 2018
Resolved
Gauge wasted areas in the forepeak longitudinal bulkheads w/ CG and ABS present.
Action required: 705 - Other - as specified
Resolved 21 March 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 March 2018
Resolved
Gauge wasted areas in the collision bulkhead w/ CG and ABS present.
Action required: 705 - Other - as specified
Resolved 21 March 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 March 2018
Resolved
Gauge wasted areas in the cofferdam bulkhead w/ CG and ABS present.
Action required: 705 - Other - as specified
Resolved 21 March 2018
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2018
Resolved
Replace all damaged wire armor onboard IAW 46 CFR 111.05-7.
Action required: 705 - Other - as specified
Resolved 20 December 2018
Construction/Loadline › Structures › Deck Plating
Issued 6 February 2018
Resolved
Crop and renew deck plating under port ballast pump house.
Action required: 705 - Other - as specified
Resolved 8 March 2018
Resolution: Steel around the deck house has been replaced. Affected area under will be clad welded.
Construction/Loadline › Structures › Deck Plating
Issued 6 February 2018
Resolved
Crop and renew deck plating under the stbd ballast pump house.
Action required: 705 - Other - as specified
Resolved 20 December 2018
Construction/Loadline › Structures › Deck Plating
Issued 28 December 2017
Resolved
Complete gauging of main deck and centerline bulkheads.
Action required: 705 - Other - as specified
Resolved 27 February 2018
Resolution: Completed gauging of the main deck.
Construction/Loadline › Structures › Deck Plating
Issued 11 December 2017
Resolved
Provide gauging report for wastage found on main deck plating IWO collision bulkhead (#4) on both #1 port and starboard cargo tanks just aft of the transverse bulkhead.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Construction/Loadline › Structures › Deck Plating
Issued 11 December 2017
Resolved
Provide gauging report for main deck plating IWO bulkhead #60 separating #8 port and stbd cargo tanks and aft void.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Construction/Loadline › Hull › Transverse Frame
Issued 11 December 2017
Resolved
Provide gauging report for transverse frames #32 (between #4 and #5 stbd cargo), #39 (between #5 and #6 stbd cargo), and #46 (between # 6 and #7 stbd cargo).
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Replaced top 18 inches of each transverse bulkhead.
Construction/Loadline › Structures › Trunk
Issued 11 December 2017
Resolved
Provide gauging report on wastage found on #3 port cargo tank expansion dome on vertical bulkhead located just under the hatch cover bolts.
Action required: 705 - Other - as specified
Resolved 20 December 2018
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 11 December 2017
Resolved
Provide hazardous location plan drawing.
Action required: 705 - Other - as specified
Resolved 11 December 2017
Resolution: Provided hazardous location drawing.
Deck/Cargo › Cargo Heating › General
Issued 29 December 2016
Resolved
Thermal Fluid Heater (TFH) was locked out/tagged out by operator due to leak into the cargo tanks that couldn't be located. Do not use until USCG MI recieved report of a successful hydro test of the cargo heater lines and witnesses a satisfactory test of alarms and shutdowns.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 7 July 2026
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 29 December 2016
Resolved
Cargo hoses were not labeled with the service intended.
Action required: 705 - Other - as specified
Due 29 January 2017
Resolved 29 December 2016
Resolution: Crewmembers properly labeled cargo hoses prior to inspectors departing from the barge.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 28 December 2016
Resolved
PV and HPV testing documentation was incomplete and inaacurate (01 HVPV listed as tested when 02 are installed, vacuum side not tested for both HVPVs and PVs, wrong testing pressure listed for HVPVs and PVs). Do not load cargo until proper HVPV and PV testing certificates are provided.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2017
Resolved 30 December 2016
Resolution: PVs and HVPVs were re-tested and new certificates provided. USCG MI conducted phone interview with testing tech rep and recieved adequate calibration certs for testing equipment used.
Deck/Cargo › Cargo Heating › General
Issued 6 January 2016
Resolved
Vessel was unable to test thermal fluid heater. Prior to loading any cargoes that require TFH, have testing witnessed by a MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2016
Resolution: Tech was onboard and inspectors were able to test all alarms and shutdowns with satisfactory results.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 6 January 2016
Resolved
Post proper life jacket donning placard.
Due 13 January 2016
Resolved 7 January 2016
Resolution: Viewed proper lifejacket donning placards are onboard and posted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 January 2016
Resolved
Port nav light is inoperable. Replace/repair
Due 7 January 2016
Resolved 7 January 2016
Resolution: Port running light was replaced and tested with satisfactory results.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2016
Resolved
Remove stray wire on #1 Gen and by forward pump room
Due 6 February 2016
Resolved 26 January 2016
Resolution: Received report and pictures illustrating the exposed wire has been pulled and the def has been rectified.
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 January 2016
Resolved
Repair vent pipe for potable water tank.
Due 6 February 2016
Resolved 7 January 2016
Resolution: Witnessed satisfactory repair of the potable water tank vent.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 6 January 2016
Resolved
Provide and post line diagram.
Due 6 February 2016
Resolved 26 January 2016
Resolution: Received picture from vessel rep illustrating the the cargo piping line diagram has been posted in the proper location on the vessel.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 January 2016
Resolved
Properly lable circuit breaker panels in aft STBD cargo pump room.
Due 6 February 2016
Resolved 26 January 2016
Resolution: Received pictures from vessel rep illustarting that the distribution panels have been properly labeled.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 6 January 2016
Resolved
P/V valve on forward port vapor line is frozen. Repair/ replace provide documantation for testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2016
Resolution: Witnessed replacement of the VCS p/v valve on vessel and reveiwed report that the new valve has been tested to the proper pressure settings.
Deck/Cargo › Cargo Stowage › General
Issued 6 January 2016
Resolved
Replace SOPEP and fire suit lockers.
Due 6 February 2016
Resolved 26 January 2016
Resolution: Received pictures from vessel rep that the SOPEP and firesuits lockers have been replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 6 January 2016
Resolved
Repair E-shutdown on FWD STBD cargo pump engine prior to conducting cargo ops with that engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2016
Resolution: Witnessed satisfactory test of the emergency stop system on the cargo pump prime movers.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 January 2016
Resolved
2 missing smoke detectors in quarters area.
Due 6 January 2016
Resolved 6 January 2016
Resolution: Smoke detectors were located and replaced during inspection.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 5 October 2011
Resolved
Each berthing must have a light. Berthing missing headlamps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 2 November 2011
Resolution: Completed SAT check of installed rack lighting.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 5 October 2011
Resolved
Pressure gage shall be visible from control station from pump. Gages not visible from pump control station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 2 November 2011
Resolution: Completed SAT check of pressure gage and ensured visibility form pump control station.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 5 October 2011
Resolved
Stowage of paint must not have any electrical equipment unless an approved space. Paint currently stored in an unapproved space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 2 November 2011
Resolution: Completed SAT inspection of newly installed paint locker.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 October 2011
Resolved
Lifebouys must be marked with name of vessel and port. Lifebouys are not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 2 November 2011
Resolution: Completed SAT inspection of properly labeled ring lifebouys.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 5 October 2011
Resolved
Cargo pump shall be isolated from source of vapor ignition by a gas tight bulkhead. Shaft penetration through bulkheads are not gas tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 2 November 2011
Resolution: Completed SAT inspection of all cargo pump shaft penetration modifications.
Stability › Unintentional Flooding › General
Issued 21 December 2010
Resolved
Properly renew the Port and Starboard running light, electrical cable penetrations through the main deck. (O/O attempted to have MSU GALV clear the deficiency by using red hand epoxy to cover the deteriorated penetration) Advised O/O that if not properly repaired by due date, the barge will be detained until corrected. USCG inspector please verify.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 10 January 2011
Resolution: Inspectors verified the electrical cable penetrations were properly renewed and in satisfactory condition.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 22 November 2010
Resolved
Flame screens were found with excess corrosion and debris. All flame screens are to be renewed and in serviceable condition NLT 22 Dec 10.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 21 December 2010
Resolution: Verified flame screen condition and proper installation
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 November 2010
Resolved
Renew wasted wire supports outside both aft cargo pump rooms, replace missing wire supports at forward overfill alarm sensor, and renew stuffing box tube IWO stbd sidelight.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 21 December 2010
Resolution: Verified renewal of cable supports
Deck/Cargo › Ballast › Pumps
Issued 22 November 2010
Resolved
Renew starboard ballast pump angle drive shaft coupling cover.
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 10 January 2011
Resolution: The Starboard ballast pump angle drive shaft coupling was outfitted with a new metallic cover.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 November 2010
Resolved
Renew wasted gasket at aft exhaust louver for thermal fluid heater.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 21 December 2010
Resolution: [name withheld] verified proper installation of new gasket in the ventilation cover.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 November 2010
Resolved
Prove proper operation of the combustible gas meter.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 21 December 2010
Resolution: [name withheld] verified there was on calibrated meter on board and witnessed the calibration of a secont meter.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 October 2008
Resolved
Demonstrate emergency shutdown of #2 stbd side pump engine prior to using pump for cargo operations.
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 14 October 2008
Resolution: Received letter from vessel rep attesting that the shutdown head assembly was replaced, engine shutdown tested and found satisfactory. Deficiency cleared.
Deck/Cargo › Cargo Heating › General
Issued 14 February 2006
Resolved
Prove proper operation of thermal fluid heater including required tests in accordance with 46CFR61.30-20 to the satisfaction of an attending marine inspector. Vessel is restricted from using thermal fluid heater until this requirement is met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2006
Resolved 18 February 2006
Resolution: Received field service report from technician, certifying the thermal fluid heater for operational use.
Engineering › Fuel Oil Service System › Hose
Issued 27 December 2005
Resolved
All cargo pump engine's have fuel and lube oil hoses that are well beyond a reasonable service life. Outer fire retardant cover crumbles in hand exposing inner reinforcement. Reinforcement is tacky to the touch indicating that the inner liner is breaking down. Replace all hose as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2005
Resolution: Attended vessel to observe test of newly installed hoses. All F/O and L/O service hose was replaced on all pump engines.
Engineering › Fuel Oil Service System › Hose
Issued 27 December 2005
Resolved
Generator engines have hoses in fuel and lube oil service that do not meet 46CFR56.60-25(b). Replace all improper materials accordingly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2006
Resolved 17 February 2006
Resolution: Hoses have been replaced to comply with 46 CFR 56.60-25(b).
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 December 2005
Resolved
Various engine installations have nonjacketed exhaust piping that is not properly insulated IAW ABS Rules. Properly insulate piping accordingly. 46CFR31.10-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2006
Resolved 17 February 2006
Resolution: Concerned area''s of exhaust piping have been insulated.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 27 December 2005
Resolved
Flame screen on C/T 3s is holed and will not function as intended. Repair flame screen prior to cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2006
Resolution: Unit repaired on the spot.
Deck/Cargo › Cargo Heating › General
Issued 27 December 2005
Resolved
Thermal fluid heater is leaking an excessive amount of combustion gasses from gaps in the sheathing surrounding the unit. Identify the source of exhaust gasses and repair
Condition: Improper/Lack of Maintenance
Due 14 February 2006
Resolved 18 February 2006
Resolution: Leaks have been repaired by a certified technician.
Electrical › Electrical Distribution System (service) › Switch
Issued 27 December 2005
Resolved
Floodlight switch in thermal fluid heater house is missing cover. Provide proper cover for box.
Condition: Improper/Lack of Maintenance
Due 27 January 2006
Resolved 17 February 2006
Resolution: Wire was removed back to breaker panel.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 December 2005
Resolved
Dead end wiring hangs from overhead in thermal fluid heater house. Properly terminate or remove.
Condition: Improper/Lack of Maintenance
Due 27 January 2006
Resolved 17 February 2006
Resolution: Wire was removed back to breaker panel.
Lifesaving › Immersion Suits › General
Issued 27 December 2005
Resolved
Provide immersion suit that is size appropriate for use by the mate, [name withheld], prior to his sailing outside the boundary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2005
Resolution: Observed new "JUMBO" size immersion suit on-board.
Engineering › Diesel Engine (auxiliary) › Distributor (air start)
Issued 6 February 2004
Resolved
Prior to using newly installed generator, call U.S. Coast Guard for In-Kind inspection. Provide generator specs prior to use.
Action required: 705 - Other - as specified
Resolved 15 September 2004
Construction/Loadline › Structures
Issued 4 February 2003
Resolved
Renew gaskets on FWD Port & Starboard cargo pump engine intake vent covers. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 24 November 2003
Construction/Loadline › Structures
Issued 4 February 2003
Resolved
Renew gasket on generator house door. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 24 November 2003
Electrical › Lighting (service)
Issued 4 February 2003
Resolved
Renew extinguished light bulbs in generator space. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 4 February 2003
Electrical › Electrical Distribution System (service)
Issued 4 February 2003
Resolved
Repair ground detection light malfunction on panel in generator space. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 24 November 2003
Engineering › Fuel Oil Service System › Hose
Issued 4 February 2003
Resolved
Renew/Repair fuel oil return line on fwd starboard cargo pump engine.
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 4 February 2003
Lifesaving › Inflatable Liferafts
Issued 6 September 2002
Resolved
Prior to the vessel's departure from the port of Philadelphia, later modified to prior to operating as a manned barge, provide service to the vessel's 6 man life raft. LEGACY COMPONENT DESC: Servicing
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Lifesaving › Inflatable Liferafts
Issued 6 September 2002
Resolved
Prior to the vessl'e departure from the port of Philadelphia/later modified to prior to operating as a manned barge, properly afix serviced 6 man life raft to the barge via painter to vessel with an approved weak link in accordance with 46CFR199.190 or 46CFR199.175. LEGACY COMPONENT DESC: Weak Link
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Communications › Radio Communications
Issued 6 September 2002
Resolved
Prior to the vessels departure from the port of Philadelphia/later modified to prior to operating as a manned barge, replace broken EPIRB and replace outdated hydro-release and broken hydro-release pin. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 6 September 2002
Resolved
Replace missing exhaust lagging on cargo pump aft outboard and forward starboard prior to these pumps being placed in operation or prior to the next cargo operation. LEGACY COMPONENT DESC: Exhaust blankets (lagging)
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Electrical › Lighting (service)
Issued 6 September 2002
Resolved
Repair or replace extinguished deck lighting in way of aft cabin deck house. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 6 September 2002
Resolved
Prior to placing port side outbard main generator set in operation, repair fuel leaks on or throught the fuel system of this gen set and replacemissing/loose rectifier cover on this genset. LEGACY COMPONENT DESC: Fuel leaks
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 6 September 2002
Resolved
Replace missing exhaust pipe blanket (lagging) on port outboard generator set. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Fire Fighting › Miscellaneous Items
Issued 6 September 2002
Resolved
Provide attentionto the vessel's housekeeping and eliminate fire hazards noted in standing lube oil in drip pans, oily rags left on deck in way of apparent fuel leaks, open buckets of lube oil in all machinery spaces and noted oil blow by from deck machinery on deck and bulkheads in the generator s LEGACY COMPONENT DESC: Waste Receptacles
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 6 September 2002
Resolved
Noted severe oil leaks on aft outboard cargo pumps prime mover. Provide repairs to this main diesel enging to correct oil sling and blow by. To be completed prior to the vessels next cargo operation "discharge". LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 4 February 2003
Deck/Cargo
Issued 27 June 2001
Resolved
REPLACE ANCHOR THAT WAS LOST OFF OF BRIDGEPORT, CT ON 26 JUNE 2001.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 20 November 2000
Resolved
C/R cracked sideshell #1S C/T IWO bays 3 & 4 and SSL's 12 & 13. Approx. 4' x 4'. Vsl is not to conduct commercial ops until cleared by USCG. Air test at 1.5 psig upon completion of repairs. This item may be completed to the satisfaction of ABS or the USCG.
Condition: Unknown
Due 21 November 2000
Resolved 21 November 2000
Engineering
Issued 20 November 2000
Resolved
Provide an accurate hand tach to conduct overspeed tests on #1 & 2 generators. Not to exceed 115% of rated speed.
Condition: Unknown
Due 21 November 2000
Resolved 21 November 2000
Electrical
Issued 20 November 2000
Resolved
Renew ground detector lamps on switchboard and prove SAT operation.
Condition: Unknown
Due 20 November 2000
Resolved 21 November 2000
Lifesaving
Issued 26 November 1997
Resolved
REMOVE/REPLACE EPIRB.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 26 November 1997
Resolved
INSTALL (2) BII PORTABLE FIRE EXTINGUISHERS ON CARGO DECK.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 26 November 1997
Resolved
WIPE UP EXCESS OIL AND FUEL UNDER ALL ENGINES.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 26 November 1997
Resolved
REPLACE BURNT OUT LIGHTING IN ALL PUMPHOUSE AND ENGINE ROOMS.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 26 November 1997
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOYS.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Electrical
Issued 26 November 1997
Resolved
INSTALL BLANK OVER OPEN CIRCUIT BREAKER OPENING IN AFT PUMPROOM.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 26 November 1997
Resolved
INSTALL COVERS OVER START BATTERIES ON ALL ENGINES.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 26 November 1997
Resolved
REPLACE FLAME SCREENS ON CARGO TANK PV VALVES 1 STBD, 2 STBD, 4 STBD, 8 STBD.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Engineering
Issued 30 November 1995
Resolved
REBRICK REFRACTORY IN THERMAL FLUID HEATER, PROVE PROPER OPERATION OF TFH_x001C_ AND CONDUCT ALL FIELD TEST PROCEDURES IN THE PRESENCE OF A MARINE INSPECTORPRIOR TO OPERATION OF THERMAL FLUID HEATER.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 1 December 1993
Resolved
Blank off openings in 120v power panel in aft cargo pump room.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 1 December 1993
Resolved
Repair water tight door on stbd side of accommodation space.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Deck/Cargo
Issued 1 December 1993
Resolved
Hydro statically test all cargo trasfer hoses.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 21 January 1993
Resolved
BARGE IS TO PROCEED TO TEXAS DRYDOCK CO., ORANGE, TX FOR DRYDOCK (HULL) EXAMINATION. VESSEL IS NOT TO TAKE CARGO IN TRANSIT. DRYDOCK EXAM TO BE PERFORMED BY COGNIZANT OCMI.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Electrical
Issued 21 January 1993
Resolved
TEST (OVERSPEED) TRIP ON INBOARD GENERATOR #2 IN THE PRESENCE OF CG MARINE INSPECTOR. _x001C_
Condition: Unknown
Due 29 January 1993
Resolved 22 January 1993
Engineering
Issued 21 January 1993
Resolved
THERMAL FLUID HEATER IS TO BE SATISFACTORILY OPERATED AND TESTED AS PER 46 CFR 61.30-20. TFH MUST BE TESTED IN THE PRESENCE OF CG MARINE INSPECTOR. TFH SHALL NOT BE USED TO HEAT CARGO OR OPERATED FOR TRANSFERS UNTIL TESTED.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 1 March 1991
Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991