Records from 1990 to 2007. Most recent: inspection, 18 October 2007.
Inspection history · 34
18 October 2007
Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3082128
29 August 2006
Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2762718
29 August 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2783000
29 March 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2612105
27 March 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2610100
7 December 2005
In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2547404
23 August 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2471823
20 August 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2499583
8 August 2005
Excursion Permit
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2456099
11 April 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2331068
9 August 2004
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2207601
9 August 2004
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2214142
27 August 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1934466
12 June 2002
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1629647
22 May 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1447109
6 June 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1404990
8 September 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1402944
22 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793032
28 April 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793366
17 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110790
20 February 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 789456
28 May 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1086015
15 April 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085751
9 April 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1079804
7 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1019717
3 June 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1327255
8 June 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142862
26 June 1992
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957760
18 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1262874
21 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957460
25 June 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 921998
12 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 905949
12 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 927539
28 February 1990
Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 917363
Stability › Incline Test › General
Issued 21 July 2008
Resolved
No stability test ever conducted on the vsl. Owner given to 21 August 2008 to complete simplified stability test in the presence of Coast guard Marine Inspector.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 4 September 2008
Resolution: Vsl passed stab test for 23 persons at 140 lbs per person.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 29 August 2006
Resolved
Install UL approved fire detecting system in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2006
Resolved 1 September 2006
Resolution: Witnessed approved fire detecting system.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 29 August 2006
Resolved
Provide copy of current state registration.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 1 September 2006
Resolution: Copy of state registration provided.
Engineering › Bilge Water Management System › Not Operational
Issued 29 August 2006
Resolved
Repair inoperable bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2006
Resolved 1 September 2006
Resolution: Bilge high level alarm operable. All sat.
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 August 2006
Resolved
Replace worn red gear cooling hoses.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 1 September 2006
Resolution: Worn hoses replaced. All sat.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 29 August 2006
Resolved
Remove all excess oil from bilge.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 1 September 2006
Resolution: Oil removed from bilge. All sat.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 29 August 2006
Resolved
Clean and inspect racor filter.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 1 September 2006
Resolution: Racor inspected and cleaned. All sat.
Engineering › Steering Gear System › Linkage
Issued 29 August 2006
Resolved
Replace keeper clip for transmission linkage.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 1 September 2006
Resolution: Keeper clip replaced. All sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 December 2005
Resolved
Properly stow life jackets and seperate adult life jackets from childrens.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 29 August 2006
Resolution: All jackets seperated sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 December 2005
Resolved
Remove all dead end wiring throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2006
Resolved 1 September 2006
Resolution: All dead end wiring removed. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2005
Resolved
Install audible and visual bilge alarm indicators at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2006
Resolved 1 September 2006
Resolution: Audible and visual alarm indicators installed. All sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 December 2005
Resolved
Properly mark stowage location for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 29 August 2006
Resolution: Location marked sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 7 December 2005
Resolved
Properly mount portable fire extinguishers so they are clearly visible and accessible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 29 August 2006
Resolution: Fire extinquisers mounted sat.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 7 December 2005
Resolved
Install UL approved fire detecting system in engineroom.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2006
Resolved 1 September 2006
Resolution: Approved fire fighting detection installed. All sat
Engineering › Steering Gear System › Rudder
Issued 7 December 2005
Resolved
Provide auxiliary means of steering.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 29 August 2006
Resolution: Due to vessel being certifcated under Old sub chapter "T" and the vessel is operating on a LBS 1000" route a second means of steering is not required.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 August 2005
Resolved
Properly install a brackets for the BII and BI portable fire extinguishers, (engine space and operator station).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 13 September 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 August 2005
Resolved
Install/secure hand railing at the entry step to launch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2005
Resolved 23 August 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 23 August 2005
Resolved
Repair high level bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2005
Resolved 23 August 2005
Construction/Loadline › Structures › Scuttle
Issued 23 August 2005
Resolved
Install captive chains for on deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 13 September 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 August 2005
Resolved
Replace worn transmission hoses.
Condition: Improper/Lack of Maintenance
Due 15 September 2005
Resolved 13 September 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 23 August 2005
Resolved
Repair loose mast light fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2005
Resolved 23 August 2005
Engineering › Bilge Water Management System › Not Operational
Issued 9 August 2004
Resolved
Install and connect electrical wiring to the bilge pump, and prove proper operation of the pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2004
Resolved 9 August 2004
Resolution: Wiring for the bilge pump installed and properly connected. Tested bilge pump.
Engineering › Bilge Water Management System › Valve
Issued 9 August 2004
Resolved
Install overboard discharge valve on the bilge system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: Valve installed.
Engineering › Bilge Water Management System › Hose
Issued 9 August 2004
Resolved
Replace worn overboard bilge discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: Hose replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 August 2004
Resolved
Replace the worn raw water hose from the through hull valve to the MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: Hose replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 August 2004
Resolved
Install double hose clamps for all fittings in line with the through hull valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: All fittings double hose clamped.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 August 2004
Resolved
Inspect and properly connect the emergency pull linkage to the fixed fire extingusher system for the engine room space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: Engine room space fire extingushing system properly installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 August 2004
Resolved
Provide and install sixty feet of line for the life ring.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 9 August 2004
Resolution: Sixty feet of line installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2004
Resolved
Provide first aid kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Resolution: First aid kit provided.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 9 August 2004
Resolved
Post on the vessel near the operating station, emergency operating instructions.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 9 August 2004
Resolution: Emergency operating instructions posted.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 August 2004
Resolved
Label lifejacket storage areas.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 9 August 2004
Resolution: Lifejacket storage areas properly labeled.
Lifesaving › Lifebuoys
Issued 27 August 2003
Resolved
Demonstrate properly operating waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2003
Resolved 7 October 2003
Resolution: Battery replaced.
Lifesaving
Issued 22 May 2001
Resolved
REBOLT AFT WATERTIGHT HATCH.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Engineering
Issued 6 June 2000
Resolved
Renew flexible cooling inlet hose(exhaust).
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Engineering
Issued 6 June 2000
Resolved
Renew flexible exhaust hose.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Documentation
Issued 15 April 1996
Resolved
PRIOR TO CARRYING PASSENGERS, HAVE THE SECOND REINSPECTION CONDUCTED ON BOARD THE VESSEL.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Navigation
Issued 8 June 1993
Resolved
PRIOR TO OPERATION, PROVIDE A SUFFICIENT SOUND PRODUCING DEVICE AS REQUIREDBY RULE 33 OF THE NAVIGATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Fire Fighting
Issued 8 June 1993
Resolved
PROVIDE RETAINING BRACKETS FOR BOTH BIII DRY CHEMICAL FIRE EXTINGUISHERS STORED IN THE FORE PEAK.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Engineering
Issued 25 June 1990
Resolved
INSTALL PROPER FUEL VENT PIPE DIAMETER 5/8" IN ACCORDANCE WITH 182.20-35.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990