MAURY USCG vessel records Sign in
← All vessels

ROCKMORE

ROCKMORE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1992, most recently in May 2017, along with 95 deficiencies — 7 with no resolution recorded —.

Records from 1992 to 2017. Most recent: inspection, 17 May 2017.

Built
1987
Last inspected
17 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAD6502
376268
Flag
UNITED STATES
—
Maury page id
psix-376268

Inspections, by type

…with no type recorded9
…past their stated due date7
Years with a record 20 calendar years (1992–2017)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

Inspection history · 48

17 May 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6148966
9 June 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5908268
25 February 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3690263
9 June 2008 Annual Inspection · Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232515
22 May 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3220981
13 May 2008 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3205554
6 July 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2985486
9 March 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2884976
29 August 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2783000
10 May 2006 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2645452
29 March 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2612105
27 March 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2610100
22 August 2005 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2480877
20 August 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2499583
21 July 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2434040
7 June 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2090954
27 August 2003 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1918514
27 August 2002 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1667283
12 June 2002 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1629650
4 September 2001 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1072626
21 June 2001 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435225
7 July 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1397458
6 June 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1399404
7 July 1999 Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1470536
3 July 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 136455
26 May 1999 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 809671
22 June 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793025
6 April 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123584
1 July 1997 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1113296
17 June 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110649
4 July 1996 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 933927
28 May 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1192517
9 April 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1079892
10 July 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 881970
1 June 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875352
25 July 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1176320
19 July 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 870567
3 June 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329656
18 April 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 857561
31 March 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1165904
30 June 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 843719
29 June 1993 Deadweight Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156222
25 June 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 843959
1 February 1993 Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 829461
1 February 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1139803
16 November 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1137032
17 September 1992 Deadweight Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1269025
30 June 1992 Initial Certification · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1269731

Deficiency record · 95

Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 June 2008 Resolved
Documentation - Floating assembly not ready for inspection.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 3 July 2008
Resolution: Annual inspection completed
Fire Fighting › Fire Pumps › Arrangement
Issued 9 June 2008 Resolved
Firefighting - No fire pump on board. Your vessel is certificated as 114ft in length, provide fire fighting pump system in accordance with 46 CFR 181.300 (all that applies)
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Portable Yanmar diesel pump semi/permanently installed on float #2
Fire Fighting › Fire Hoses › Number
Issued 9 June 2008 Resolved
Firefighting - No 1.5 inch certified fire hose on board. Provide 1.5 fire hose in accordance with 46 CFR 181.320 all that applies
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Two 50'' lengths of hose provide
Fire Fighting › Fire Main › Condition
Issued 9 June 2008 Resolved
Firefighting - No fire main system on board to support fire fighting operations, either provide sufficient hose length to engage in fire fighting operations anywhere on board or provide fire main and hydrant system in accordance with 46 CFR 181.310 all that applies.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Sufficient hose length provided
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 June 2008 No resolution recorded
Firefighting - Galley ventilation system and grease extraction system installed incorrectly. In accordance with 46 CFR 181.425 Equipment in this system must meet Underwriters Labratory 710 "Exhaust hoods for commercial cooking equipment" and installation of equipment must meet NFPA 96 "Standard for ventilation control and fire protection of commercial cooking operations".
Action required: 705 - Other - as specified
Due 30 June 2008 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 9 June 2008 Resolved
Pollution - Galley hood grease extraction/collection system discharges directly overboard in violation of 33 CFR 151, the Federal Water Pollution Control Act and Oil Pollution Act of 1990. Install proper grease and oil retention system on board, make provisions for proper disposal of waste oils ashore.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 22 July 2008
Resolution: Propane sytem has been removed and the grease extraction system will no longer be needed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 June 2008 Resolved
Pollution - Sewage arrangement on board is not installed to manufacture specifications. Vent pipe on Liberty sewage lift pump required to be minimum height above sewage collection tank. Manufacture recommends a minimum 10 foot stand pipe fastned to building for support.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 21 July 2008
Resolution: vent pipes installed sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 June 2008 No resolution recorded
Pollution - Sewage holding tank inadequately protected or vented as per 33 CFR 159 all that applies to marine sanitation system Type III. Repair cover over holding tank and make repairs to vent stand pipe. Make all parts accessable to routine maintenance and inspection.
Action required: 705 - Other - as specified
Due 30 June 2008 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 June 2008 Resolved
Pollution - No visible Marpol V sewage placard posted as per 33 CFR 159.59. Provide sewage placard and post in a visible place that can be seen while conducting sewage transfer or maintenace operations.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Placard posted
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 June 2008 Resolved
Pollution - No visible means of level indication on enclosed sewage tank. Lifting lid and exposing crew persons to vapors is not an acceptable means of level indication. Provide acceptable level indicator as per 33 CFR 159.83.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Level indicator installed (clear plastic tube)
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 9 June 2008 Resolved
Occupational Safety - Propane system unsatisfactory in design, installation, and maintained condition. Cooking equipment & gas systems for LPG required to meet 46 CFR 184.220, 46 CFR 184.240, American Boat and Yacht Council (ABYC) A-1 "Marine LPG Systems" & National Fire Protection (NFPA) 302 Ch 6 "Cooking systems" Bring LPG cooking system into compliance with noted regs.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 22 July 2008
Resolution: Propane system removed.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 9 June 2008 Resolved
Occupational Safety - Numerous galley electrical outlets missing plug covers. As per 46 CFR 111.79-1 provide drip proof plug covers for all outlets.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 24 June 2008
Resolution: Outlet covers installed
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 9 June 2008 Resolved
Firefighting - Excessive build-up of grease from ventilators on exterior roof of galley. As per 46 CFR 176.830 this is a fire hazard. Remove grease from roofing material, make provisions for routine cleaning to minimize build-up.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 24 June 2008
Resolution: Roof cleaned and re coated w/ roofing cement
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 June 2008 Resolved
Occupational Safety - Potable water (drinking water) system on mechanical float is unsanitary. Storage tanks, pumps, and hoses in direct vicinity of liquid sewage, garbage waste, fuel oil, and engine exhaust pollutants. Water system is at a high degree of risk from cross contamination with these systems. Provide a suitable structure to isolate this system and protect it from contamination.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Dog house constructed over tanks & pumps. Water service lines re-routed away from sewage lines.
Documentation › Markings/Placards › Capacity Marking
Issued 9 June 2008 Resolved
Documentation - Visible indicator of maximum number of persons on each float not posted. COI designates maximum number each float may carry, provide placard or other suitable means of indicating max number of persons allowed in a highly visible place where passengers and crew can see it.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Signs w/ max persons allowed placed on each float
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 June 2008 Resolved
Electrical - Circuit breaker boxes missing doors and lables. Provide closure door for boxes and properly label circuit breakers as per 46 CFR 183.220 and 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Doors replaced, lables installed
Stability › Incline Test › General
Issued 9 June 2008 No resolution recorded
Stability - Floats 1,2,3 are certificated and have a stability letter. Float 4, containing the mechanical systems has no stability letter yet it is an integral part of the operation and is attached in the same manner as the other floats and is readably accessible by the crew. Remove all cleats from float 4 and provide plans for constuction and testing of new float prior to operations in 2009.
Action required: 705 - Other - as specified
Due 30 June 2008 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 June 2008 Resolved
Operations - Personnel drills not conducted. Conduct drills to include fire, man overboard, and abandon ship.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Drills conducted satisfactorily
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 June 2008 Resolved
Firefighting - Wires impropely installed in control box for galley vent hood fire suppression system. Have certified technician repair and recertifiy this system as per 46 CFR 181.425
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 24 June 2008
Resolution: Fire appliance tech has repaired and recertified system
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 9 June 2008 Resolved
Engineering - Generator not bolted down to deck of float. Fasten generator to float to prevent movement of unit as per 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 24 June 2008
Resolution: Generator is bolted to deck
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 June 2008 Resolved
Engineering - Diesel generator auxiliary fuel tank not properly fastened down to prevent movement. Properly brace and support fuel tank as per 46 CFR 182.440 (b) (3).
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: Fastned down with steel cable
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 June 2008 Resolved
Engineering - Diesel generator independant fuel tank not electrically bonded to common ground. Provide neccessary bonding equipment for fuel tank as per 46 CFR 182.440 (b) (4).
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Resolution: E-bonded to generator
Stability › Incline Test › General
Issued 9 June 2008 Resolved
Issued requirement for stability test to be completed w/ in 21 days (24JULY2008) on mechanical float (float #4)
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 21 July 2008
Resolution: Changed 835
Fire Fighting › Fire Hoses › Connections
Issued 9 June 2008 No resolution recorded
Provide spanner wrenchs, pump cover and hose station for fire pump.
Due 4 August 2008 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2008 No resolution recorded
Remove all extension cords from float 4.
Due 4 August 2008 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 June 2008 No resolution recorded
Replace 22 adult life jackets.
Due 21 July 2008 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 July 2007 Resolved
Properly install batteries in Galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 6 July 2007
Electrical › Electric Supply System (service) › Cable
Issued 6 July 2007 Resolved
Remove loose and dead wiring from old /unused circuits in Galley
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 6 July 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 July 2007 Resolved
galley sink drain disconnected.
Condition: Unknown
Due 6 July 2007
Resolved 6 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 July 2007 Resolved
Condition: Improper Installation
Due 6 July 2007
Resolved 6 July 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 6 July 2007 Resolved
Condition: Unknown
Due 6 July 2007
Resolved 6 July 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 6 July 2007 Resolved
Galley fan and wiring covered in grease. Clean fan, provide new plug for fan.
Condition: Improper/Lack of Maintenance
Due 6 July 2007
Resolved 6 July 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 July 2007 Resolved
remove and properly stow all paint and associated chemicals from outside galley space.
Condition: Improper Installation
Due 6 July 2007
Resolved 6 July 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 6 July 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 July 2007
Resolved 6 July 2007
Documentation › Certificates/Documents › Stability Letter
Issued 22 August 2005 Resolved
Properly display all pages of applicable vessel stability letter.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Construction/Loadline › Structures › Superstructure
Issued 22 August 2005 Resolved
Provide protection from chafing and install conduit run to limit tripping hazard in way of aft house/ generator float.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 22 August 2005 Resolved
Provide protection from chafing elements for power supply lines in way of turnbuckles in way of the main floats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Personnel › Training › Fire Fighting Basic
Issued 22 August 2005 Resolved
In accordance with 46 CFR 185.504 provide an accurate and immediate passenger count at all times while passengers are embarked.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 August 2005 Resolved
All life jackets 143 adult and 15 children shall be stowed in an accessible location to passengers at all times passengers are embarked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Stability › Incline Test › General
Issued 22 August 2005 Resolved
Provide documentation attesting to the consideration of presently installed canopy with in vessel stability calculation limitations.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2005 Resolved
provide conduits and proper wire runs for cable/wire/power cords in way of galley/house/office.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 August 2005 Resolved
Provide proper waste receptacles and stowage area on aft generator package- separation of trash and area in way of generator must be maintained to provide proper airflow to generator set- proposal to be acceptable to OCMI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 August 2005 Resolved
Provide separation and acceptable arrangement for (2) potable water tanks/ (1) sanitation tank on the generator float.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2005
Resolved 24 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2005 Resolved
Provide adequate first aid kit.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Provided sat.
Fire Fighting › Nozzles › Type
Issued 21 July 2005 Resolved
Provide metallic type nozzles for all fire hoses.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Provided sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 July 2005 Resolved
make permanent repairs to missing punch out IWO distribution panel.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Repairs made sat.
Electrical › Electric Supply System (service) › Cable
Issued 21 July 2005 No resolution recorded
Remove extension cords from galley exhaust fan and aft shack.
Due 28 July 2005 — due date passed with no resolution recorded
Resolution: Extension cords removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 July 2005 Resolved
Remove all grease from galley hood and ventillation ducting.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Grease removed sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 July 2005 Resolved
Address raill courses.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Netting added to rails.
Electrical › Electric Supply System (service) › Cable
Issued 21 July 2005 Resolved
provide wire run supports IWO galley.
Due 28 July 2005
Resolved 27 July 2005
Resolution: All wire runs supported sat.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 July 2005 Resolved
Provide emergency instructions that outline procedures for disconnecting attached floats in case of fire or other emergency.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Provided same.
Construction/Loadline › Structures › Superstructure
Issued 21 July 2005 Resolved
Make permanent repairs to galley roof IWO electrical panel that is holed.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Repairs made to galley roof sat.
Documentation › Certificates/Documents › Stability Letter
Issued 21 July 2005 Resolved
Post stability letter as required.
Due 28 July 2005
Resolved 27 July 2005
Resolution: stab letter posted sat.
Documentation › Logs/Records › Logbook (official)
Issued 21 July 2005 Resolved
Provide training log book.
Due 28 July 2005
Resolved 27 July 2005
Resolution: Log book provided sat.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 27 August 2003 Resolved
Provide proper number of grease traps in Gaylord Hood. Vessel out of service till spring 2004. Extended requirement to 15May04.
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 9 August 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 August 2003 Resolved
Provide proper rack to hold CO2 canisters secure.
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 7 October 2003
Lifesaving › Lifebuoys
Issued 27 August 2003 Resolved
Provide proper lanyard for life buoy ringlight. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 7 October 2003
Documentation › Certificates/Documents
Issued 27 August 2003 Resolved
Post COI on board the Vessel. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 7 October 2003
Lifesaving
Issued 12 June 2002 Resolved
Provide a life jacket donning placard.
Due 26 June 2002
Resolved 28 June 2002
Lifesaving › Lifebuoys
Issued 12 June 2002 Resolved
Replace line on 2 life rings, label and put retro tape on all life rings, and provide a life ring light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2002
Engineering › Diesel Engine (propulsion-electric)
Issued 12 June 2002 Resolved
Remove or repair the unused generator outside of the galley. If not repairing the generator remove the associated fuel tank.
Due 26 June 2002
Resolved 5 August 2002
Engineering › Diesel Engine (propulsion-electric)
Issued 12 June 2002 Resolved
Properly fasten the generator and its associated fuel tank to the deck.
Due 26 June 2002
Resolved 28 June 2002
Accommodation/Occupational Safety › Potable Water System
Issued 12 June 2002 Resolved
Place proper covers and bug screens on top of the fresh water tanks.
Due 26 June 2002
Resolved 28 June 2002
Communications › Radio Communications
Issued 12 June 2002 Resolved
Provide an emergency broadcast placard.
Due 26 June 2002
Resolved 24 July 2002
Personnel › Training
Issued 12 June 2002 Resolved
Provide emergency instructions for MOB and Fire Drills.
Due 26 June 2002
Resolved 28 June 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 12 June 2002 Resolved
Properly install a grease extraction hood, including an approved dry or wet chemical fire extinguishing system on the outboard deep fat fryer. (ref. 46 CFR 181.425 (a) (b)) Until requirement is met fryer may not be used.
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 13 September 2002
Resolution: Fryer was moved under the hood.
Accommodation/Occupational Safety › Cooking Systems
Issued 12 June 2002 Resolved
Properly install an approved dry or wet chemical fire extinguishing system in the existing range hood or install an approved range hood with fire extinguishing system (ref. 46 CFR 181.425)
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 13 September 2002
Lifesaving
Issued 7 July 2000 Resolved
PROVIDE ONE ADDITIONAL RING BUOY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 July 2000
Resolved 12 July 2000
Lifesaving
Issued 26 May 1999 Resolved
PROPERLY LABEL THE NUMBER OF PFDS CONTAINED IN EACH PFD STORAGE BIN.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Lifesaving
Issued 28 May 1996 Resolved
REPLACED 2 WASTED RING BUOYS WITH RETROREFLECTIVE TAPE.
Condition: Unknown
Due 28 May 1996
Resolved 13 June 1996
Fire Fighting
Issued 28 May 1996 Resolved
REPLACED MISSING FIRE HOSE AT FIRE STATION.
Condition: Unknown
Due 28 May 1996
Resolved 13 June 1996
Engineering
Issued 28 May 1996 Resolved
REPLACED WORN FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 28 May 1996
Resolved 13 June 1996
Accommodation/Occupational Safety
Issued 28 May 1996 Resolved
LABELED PFD STORAGE THIS EXAM.
Condition: Unknown
Due 28 May 1996
Resolved 13 June 1996
Lifesaving
Issued 28 May 1996 Resolved
REPLACED MISSING BELT GUARD TO SERVICE GENERATOR.
Condition: Unknown
Due 28 May 1996
Resolved 13 June 1996
Electrical
Issued 1 June 1995 Resolved
REHANG THE POWER CABLE, MOUNT AND PROPERLY DEAD END THE OUTLET NEAR THE SINKS IN THE GALLEY OUTLET RECEPTACLE NEAR THE SINKS IN THE GALLEY NO LATERTHAN 1JUL95.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Electrical
Issued 1 June 1995 Resolved
MAKE WEATHERTIGHT THE ELECTRICAL JUNCTION BOX ON TOP OF THE HOT WATER HEATER NO LATER THAN 1JUL95.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Electrical
Issued 1 June 1995 Resolved
PLACE BLANK BREAKERS IN THE GALLEY BREAKER BOX NO LATER THAN 1JUL95.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Accommodation/Occupational Safety
Issued 1 June 1995 Resolved
PRIOR TO MAKING DECK SPACE AVAILABLE TO PASSENGERS IN WAY OF THE PROPANE STORAGE AREA, ENCLOSE THE PROPANE CYLINDERS TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Electrical
Issued 1 June 1995 Resolved
PERMANENTLY CONNECT THE FREEZER TO THE POWER SUPPLY NO LATER THAN 1JUL95.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Accommodation/Occupational Safety
Issued 1 June 1995 Resolved
MAKE PERMANENT REPAIRS TO THE GALLEY OVERHEAD, WHERE DAMAGED, ABOVE THE ELECTRICAL BREAKER BOXES NO LATER THAN 1JUL95.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 3 June 1994 Resolved
PROVIDE AND INSTALL MAXIMUM CAPACITY LABELS FOR PASSENGERS ON EACH FLOAT,_x001C_ FOUR ON SERVICE FLOAT, FIFTY-FIVE ON MIDDLE FLOAT, AND SIXTY ON AFT AUX FLOAT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Lifesaving
Issued 3 June 1994 Resolved
PROPERLY SEPARATE CHILDRENS LIFEJACKETS FROM ADULT LIFEJACKETS.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Fire Fighting
Issued 3 June 1994 Resolved
PROVIDE AND INSTALL FIRE AXE.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Electrical
Issued 3 June 1994 Resolved
MAKE PERMANENT REPAIRS TO GENERATOR SET EXHAUST MUFFLER HANGERS AND PROPERLY INSULATE EXHAUST PIPE FROM SURROUNDING WOOD STRUCTURE.
Condition: Unknown
Due 7 June 1994
Resolved 20 June 1994
Fire Fighting
Issued 3 June 1994 Resolved
PROVIDE AND INSTALL MARINE MOUNTING BRACKETS FOR TWO B-II FIRE EXTINGUISHERS IN GENERATOR ROOM.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Fire Fighting
Issued 3 June 1994 Resolved
PROVIDE TWO ADDITIONAL B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Accommodation/Occupational Safety
Issued 3 June 1994 Resolved
PROVIDE LABELING FOR MALE AND FEMALE HEADS.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Lifesaving
Issued 3 June 1994 Resolved
PROVIDE AND INSTALL WARNING LABELS FOR LIQUID PROPANE GAS SYSTEMS AS PER ABYC._x001C_
Condition: Unknown
Due 7 June 1994
Resolved 20 June 1994
Engineering
Issued 3 June 1994 Resolved
PROVIDE GAUGES ON LIQUID PROPANE GAS REGULATORS AS PER NFPA/ CHAPTER SIX.
Condition: Unknown
Due 7 June 1994
Resolved 20 June 1994
Electrical
Issued 3 June 1994 Resolved
PERMANENTLY MOUNT LIGHTING FIXTURES IN BOTH HEADS.
Condition: Unknown
Due 7 June 1994
Resolved 20 June 1994
Fire Fighting
Issued 3 June 1994 Resolved
PROVE PROPER OPERATION OF INSTALLED FIRE PUMP.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Lifesaving
Issued 3 June 1994 Resolved
PROPERLY LABEL LIFEJACKETS STORAGE LOCKERS.
Condition: Unknown
Due 3 June 1994
Resolved 20 June 1994
Electrical
Issued 3 June 1994 Resolved
POST OIL POLLUTION PLACARD IN GENERATOR ROOM.
Condition: Unknown
Due 7 June 1994
Resolved 20 June 1994
Lifesaving
Issued 30 June 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING AND ABANDONSHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Electrical
Issued 30 June 1992 Resolved
PROVIDE CURRENT ELECTRICAL INSTALLATION PLAN FOR INSTALLED ELECTRICAL EQUIPMENT. PLAN SHOULD INCLUDE WIRING, GENERATOR, DISTRIBUTION PANEL INSTALLATIONS.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.