NIPPON MARU

NIPPON MARU is a 1990 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1992, most recently in August 2025, along with 45 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1992 to 2025. Most recent: inspection, 1 August 2025.

Built
1990
Last inspected
1 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8817631 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
360080
Flag
JAPAN
—
Maury page id
psix-360080

Inspections, by type

…with no type recorded26
…past their stated due date1
Years with a record 25 calendar years (1992–2025)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4840 - Dead Weight, Ton
22472 - Convention (Subpart B), Gross Ton
21903 - Regulatory (Subpart C or D), Gross Ton
7896 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

USS YON 308 Public Tankship/Barge · MISLE 5680 · 30 December 2018 · activity 6606211TALOFOFO Towing Vessel · MISLE 944367 · 30 December 2018 · activity 6606211CG29247 Public Vessel, Unclassified · MISLE 1542666 · 30 December 2018 · activity 6606211SAN PEDRO Industrial Vessel · MISLE 52671 · 4 February 1993 · activity 459519

Inspection history · 69

1 August 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8200348
14 January 2020 ISPS Exam · STCW 95 Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6879338
2 January 2019 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6608261
30 December 2018 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6602625
30 December 2018 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6606211
27 December 2018 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6610878
30 December 2017 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6329919
13 January 2017 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6072368
30 December 2016 Ballast Water Examination · STCW 95 Exam · MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam · MARPOL Annex V Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6063004
9 March 2016 PII Safety Exam · COC-CVE Quarterly · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5825948
30 December 2015 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5789056
2 January 2012 MARPOL Annex I Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4216829
25 June 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3247272
31 May 2007 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2948017
2 July 2006 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2696692
24 June 2006 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2689869
7 June 2006 Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2672864
26 February 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2304467
26 February 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2304472
26 January 2005 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2280908
2 January 2005 ISPS III Exam
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2267583
2 January 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2269679
2 January 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2269682
1 January 2005 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2267558
7 July 2004 ISPS II Exam · COC-CVE Annual
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2124320
1 January 2004 Security Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2041673
30 December 2003 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2050619
3 July 2003 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1834360
25 June 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1828352
23 June 2003 Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1824671
1 January 2003 MARPOL Annex V Examination · Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1722539
22 November 2002 Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1709648
18 November 2002 Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 1710457
28 June 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1638392
15 June 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1698443
12 June 2002 MARPOL Annex I Examination · MARPOL Annex V Examination · Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1628940
12 April 2002 Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1604213
29 October 2001 Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1073965
10 July 2001 MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1070946
16 June 2001 Control Verification · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1362286
27 March 2001 Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1362111
18 September 2000 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1418771
12 June 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1050900
6 June 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 278523
6 June 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279636
6 June 2000 Control Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 818686
4 July 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 430355
4 July 1999 Quarterly Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1088581
31 December 1998 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364981
4 July 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 417602
1 January 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 410648
1 January 1998 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 783502
1 January 1997 Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1098284
30 March 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 388986
30 March 1996 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1078953
31 December 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 386392
31 December 1995 Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 878935
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 884119
22 May 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 378674
31 March 1995 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1152589
11 January 1995 Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 862416
31 December 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 373637
30 March 1994 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1167510
1 January 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 363508
1 January 1994 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1159464
4 February 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 459519
29 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 356041
29 January 1993 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 828800
31 March 1992 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1270009

Deficiency record · 45

09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 January 2020 Resolved
After survey of the shop had been completed, no change shall be made in the structural arrangement without sanction of administration. Identified temporary combustible storage structures surrounding the steering gear units.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 15 January 2020 Resolved
The condition of the ship shall be mainained to conform to present regualtiuon to ensure the ship will remain fit to corceed to sea without danger to the ship or persons onboard. Identified crack in door corner into ship's laundry.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 January 2020 Resolved
Door holdback arrangments shall be fitted with remote release devices of the remote type. Fire screen door E-3 failed to properly close.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2020 Resolved
Fire extinguishers shall be periodically examined. Identified crached hoses for portable fire extinguishers inside the engineroom.
Action required: 10 - Deficiency Rectified
Due 15 January 2020
Resolved 15 January 2020
Resolution: Vessel crew replaced hoses that were found to be cracked on the semi portable unit and portable extinguisher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 December 2018 No resolution recorded
Vessel did not comply with CG SECGUAM COTP Order 101-18
Action required: 705 - Other - as specified
Due 30 December 2018 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Cable
Issued 30 December 2016 Resolved
0950 Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Multiple electrical extension cords were observed energizing the spot remover machine in the ship's laundry. SOLAS (04 cons. ed) II-1/Reg. 40.1.3 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2016
Resolved 30 December 2017
Resolution: Verified clear during this inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 December 2016 Resolved
0950 Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Unapproved wiring at electrical distribution panel powering stage lighting at dolphin hall. SOLAS (04 cons. ed) II-1/Reg. 40.1.3 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2016
Resolved 30 December 2017
Resolution: Cleared as per attached Class Survey
Personnel › Training › Crisis Management/Human Behaviour
Issued 30 December 2016 Resolved
0220 Prior to being assigned shipboard duties on board passenger ships, seafarers shall have completed training required by regulation V/2. Officers do not have training evidence for Crowd Management or Crisis Management as required by V/2. STCW (2010) CH. V Reg. V/2.4 and V/2.5 40b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2016
Resolved 13 January 2017
Resolution: Received correspondance from Japan Government providing evidence of crew competancy training.
Fire Fighting › Nozzles › Condition
Issued 31 December 2015 Resolved
All nozzles shall be of an approved dual purpose type. All exterior nozzles inspected do not funtion as intended. 74 SOLAS (81 Amend) II-2/5.8.4 Action Taken 30 a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 December 2015
Resolved 31 December 2015
Resolution: The ship's crew inspected every fire nozzle on the vessel to identify the units that did not function properly. All identified nozzles were restored temporarily with a rubber bonding glue. Crew has requested replacement nozzles and will replace all in Feb
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 December 2015 Resolved
On all general arrangement plans shall be arranged for the guidance of the ships officers. The vessel was not following their fire control plan by stowing random items in spaces throughout the ship and having installed cooking equipment in berthing and throughout accommodation spaces. 74 SOLAS (81 Amend) II-2/20 Action Taken 30 a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Resolution: All inappropriately stowed flammable materials and cooking appliances were removed from unapproved areas. Examiners examined spaces and found stowage to be in order.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 December 2015 Resolved
The opening in funnels to permit exhaust ventilation shall be reduced to a minimum consistent with the needs of ventilation and the proper and safe working of the ship. Multiple exhaust dampers were wasted and did not close properly. 74SOLAS(81Amend)II-2/11.2.1 Action Taken 30 a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Resolution: The ship's crew repaired rusted dampers with welding of new metal plates and epoxy. Adjustments were also made to the dampers allowing them to close properly.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 December 2015 Resolved
The company should ensure inspections are held at appropriate intervals. The condition of fire nozzles and dampers indicate the vessel crew is not performing adequate monthly and quarterly inspections per the vessel Manual Maintenance Guidelines, ISM 071 page AX 2-12 and 13 Action Taken 30 a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2015
Resolution: The vessel was issued an additional requirement to conduct an external ISM audit.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 31 December 2015 Resolved
Exhaust ducts from galley ranges where grease or fat is likely to accumulate shall be fitted with fixed means for extinguishing a fire. The deep fryer does not have a fixed extinguishing system. 74 SOLAS (01 Cons) II-2/41-2.4.3.4 Action Taken 30 a/c** NKK class disagreed with the requirement for fixed firefighting. Action Taken 50 a.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: Vessel provided satisfactory documentation that it is exempt from this regulation.
Construction/Loadline › Markings › Load Line Mark
Issued 31 December 2015 Resolved
The subdivision load lines shall be assigned and marked by the notation C.1. The load line was not marked C.1. 74 SOLAS (04 Cons) II-1/13.2 Action Taken 50 a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: The load line is now permanently marked with C.1.
Construction/Loadline › Markings › Load Line Mark
Issued 31 December 2015 Resolved
The load line marks shall be permanently marked on the side of the ship. The deck line did not have sufficient permanent marking. ICLL 66/ Reg 8 Unified Interpretation LL.4 Action Taken 50 a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: The deck line is now permanently marked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 December 2015 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. There electrical installations throughout the ship that are not approved and create a hazard. 74 SOLAS (01 Cons) II-1/40.1 Action Taken 40 a
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 March 2016
Resolution: All electrical hazards and unapproved installations have been removed.
Engineering › Fuel Oil Service System › Piping
Issued 31 December 2015 Resolved
The condition of the ship shall be maintained to ensure that the ship will remain fit to proceed to sea without damages to the ship or persons on board. There are general lube oil and fuel oil leaks throughout the engine room. 74 SOLAS (14 Cons) I/11 Action Taken 50 a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: The general leaks have been repaired in the engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 December 2015 Resolved
Machinery shall be installed to reduce any danger to persons on board with due regard being paid to moving parts. Machinery in the #9 A/C space was missing protective guards. 74 SOLAS (01 Cons) II-1/26.1 Action Taken 50 a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: Vessel installed protective guards over moving parts.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 31 December 2015 Resolved
11. Doors to machinery spaces shall be reduced to at minimum the proper and safe working of the ship The A60 door insulation from the A/C room to engine room was falling off. 74 SOLAS (81 Amend) II-2/11.2.1 Action Taken 10 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 31 December 2015
Resolution: The vessel's crew repaired the fire boundary insulation.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 December 2015 Resolved
Based on deficiencies #01 and #03 citing unserviceable fire nozzles and substandard condition fire dampers, Coast Guard requires external ISM audit. Action Taken 50 a.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 9 March 2016
Resolution: Vessel provided a class report for ISM Audit and implementation of new SMS procedures.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 1 January 2005 Resolved
Provide all Sub-Commanders for liferafts with a muster list.
Action required: 15 - Rectify deficiencies by next port
Due 23 January 2005
Resolved 23 January 2005
Resolution: Corrected.
Fire Fighting › Means of Escape › Mimic Plans
Issued 1 January 2005 Resolved
Highlight and provide "You Are Here" marking on passenger escape plans.
Action required: 15 - Rectify deficiencies by next port
Due 23 January 2005
Resolved 23 January 2005
Resolution: Corrected.
Lifesaving › Buoyant Smoke Signals › General
Issued 7 July 2004 Resolved
Smoke signal for life ring on port side bridge wing expired.
Action required: 705 - Other - as specified
Due 8 August 2004
Resolved 1 January 2005
Fire Fighting › Automatic Sprinkler System › Pressure Gauges
Issued 7 July 2004 Resolved
Replace sprinkler system fresh water tank pressure gauge. Have vessel's classification society test and certify.
Action required: 705 - Other - as specified
Due 8 August 2004
Resolved 1 January 2005
Lifesaving › Lifeboat
Issued 23 June 2003 Resolved
Provide exhaust port flappers to prevent the entry of sea water into the engine during operations for all lifeboats. Complete prior to departing Juneau, Alaska. LEGACY COMPONENT DESC: Exhaust Pipe
Due 26 September 2003
Resolved 31 December 2003
Documentation
Issued 6 June 2000 Resolved
COFR #103501-13 invalid without bridging or bareboat charter letter. NPFC granted one time exemption from this regulation to depart San Francisco Bay. Correct prior to entering next U.S. port.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 31 December 1998 Resolved
Provide locking device for all sprinkler zone valves. SOLAS 74 amended II-2/12.2.2
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Lifesaving
Issued 31 December 1998 Resolved
Properly install photoluminescent lifeboat placards in stairway landings incenter stairway Decks 1,2, and 3. Solas 74 amended II-2/41.2.4.7 and SOLAS74 amended III/9
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Lifesaving
Issued 31 December 1998 Resolved
Properly lubricate wire rope falls for port and stbd tender vessels. SOLAS74 amended III/19.
Condition: Unknown
Due 31 March 1999
Resolved 4 January 1999
Lifesaving
Issued 31 December 1998 Resolved
Demonstrate proper operation of all seized embarkation lighting on_x001C_ port and stbd boat decks. SOLAS 74 amended III/11.4
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Provide 2 water fog applicators in the main generator room. SOLAS 74 amended II-2/41-2.1.3
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Properly install remote indicators for all normally open and normally closed FSDs on all stairway enclosures, MVZ BHDs and galley boundaries. SOLAS 74 amended II-2/41.2.4.2.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Install smoke detector in the upper level of #5 air conditioner room, stbd side Deck 4. SOLAS 74 amended II-2/41-2.2.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Renew wasted FSD #55, main pantry stbd side Deck 4. SOLAS 74 amended II- 2/30.2.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Comply with all outstanding RFSA plan review comments in U.S. Coast Guard Marine Safety letter #16710/P003382 dated November 5, 1998.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Found that fire screen doors do not have indicator switches that show that door is completely closed. Install indicator switches in each fire screen door frame to show door is completely closed. SOLAS 74 amended II-2/41- 2.4.2.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
Properly install photoluminescent tape in the following locations: upperlevel engine room escape FR 48-50 stairway Deck 6; Fwd stairway Deck B-1; athwartships corridor at FSD #43, stbd side Deck 3. SOLAS 74 amended II-2/41-2.4.7.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 31 December 1998 Resolved
All dry chemical extinguishers require annual servicing and inspection. Install and date servicing tags. SOLAS 74 amended II-2/6.5
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Construction/Loadline
Issued 31 December 1998 Resolved
Prove proper operation of audible alarm for WTD #6. SOLAS 74 amended II- 1/15.9.1.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Deck/Cargo
Issued 4 July 1998 Resolved
REPLACE PORT LIFEBOAT FALLS AS RECOMMENDED BY CLASS SURVEY REPORT DATED 04JUL98.
Condition: Unknown
Due 3 January 1999
Resolved 3 January 1999
Lifesaving
Issued 4 July 1998 Resolved
SALT WATER COOLING SUCTION VALVE IN #8 LIFEBOAT FROZEN SO THAT ENGINE COULDNOT BE COOLED.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Fire Fighting
Issued 1 January 1998 Resolved
Fire screen doors not operable; e.g. FSD 1, 2, & 7 did not fully closed when released from electro-magnetic release. The failure of these doors tonot properly operate is non-adherence with SOLAS 74 (amended) I/11
Condition: Unknown
Due 1 January 1998
Resolved 1 January 1998
Fire Fighting
Issued 1 January 1998 Resolved
No. 92 fire damper not operable in non-adherence with SOLAS 74 (amended) I/11.
Condition: Unknown
Due 1 January 1998
Resolved 1 January 1998
Fire Fighting
Issued 1 January 1998 Resolved
Galley and #6 deck snack pantry do not have fixed extinguishing equipment for range ducts in non-adherence with SOLAS 74 (amended) II-2/41-2.
Condition: Unknown
Due 3 January 1999
Resolved 3 January 1999
Lifesaving
Issued 1 January 1998 Resolved
Starboard bridge wing orange smoke signal not fit for service, e.g. it is severely rusted and has a hole in it due to corrosion, in non-adherence with SOLAS 74 (amended) I/11 & III/19.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.