Inspection history · 42
3 January 2023
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7615525
10 October 2022
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7575552
8 September 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7556711
26 August 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7543783
14 June 2022
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7476905
14 June 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7522786
25 May 2022
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7458705
25 May 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7461550
8 April 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7429203
4 October 2021
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7325949
30 June 2021
Initial Certification · Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7240071
1 October 2020
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7069143
26 July 2020
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7016252
26 July 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7017027
8 June 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6980716
7 May 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6678437
30 December 2018
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6606211
13 February 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6380922
22 August 2017
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6297229
29 September 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6038012
21 August 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6041992
27 June 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5920735
27 April 2016
Spot Check (Safety)
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5863495
26 April 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5920807
29 January 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5807795
18 January 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5847395
14 November 2015
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5821542
14 June 2015
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5152345
14 June 2015
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5161696
20 May 2015
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5130112
20 March 2014
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4825859
12 February 2014
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4799090
4 November 2013
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4752376
4 November 2013
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4776954
5 October 2013
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4752320
16 July 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4389797
2 May 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4301637
17 April 2012
Industry Initiated Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4288222
25 January 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4231902
17 October 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4208567
24 March 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4009001
21 April 2010
Spot Check (Safety)
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3721826
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 11 October 2022
Resolved
Auxiliary generator engine low lube oil and engine high cooling water alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm. The port side generator does not have an engine display/alarms at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 28 November 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 October 2022
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. The wheelhouse’s deck is holed and leaking down to the passageway on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 2 March 2023
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 October 2022
Resolved
The master must ensure that all hatches, door, and other openings designed to be watertight or weathertight function properly. The port side quick acting watertight door to the passageway does not close properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 2 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The fixed fire pump’s shaft packing is leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 2 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 June 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Provide a technician's report for the cause of failure to the vessel's generator and prove proper operation to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Make repairs to the fuel oil pump on the port ships service generator. Generator is only to be used under emergency situations until fuel leak is resolved.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 5 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 July 2021
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Several goose neck vents throughout the vessel are missing appropriate closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 29 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 July 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting on the main deck, crew mess, lower berthing, emergency escape and port side of the engine room were inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 July 2021
Resolved
Provide proof for the certification of the fire detection system by a Professional Engineer or a NICET level IV fire alarm engineering technician.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 26 August 2022
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 July 2021
Resolved
Alarms must: (1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm. There is no audible alarm at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 July 2021
Resolved
All piping, controls, valves, and alarms must be inspected; and the operation of controls, alarms, ventilation shutdowns, and pressure-operated dampers for each fixed fire-extinguishing system and detecting system must be tested, to determine that the system is operating properly. Several leaks were found in the fire monitor system piping
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 24 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Properly terminate or encapsulate dead ended electrical wiring outboard of the bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The Marine Sanitation Device was found to be leaking
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 July 2021
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Provide a means to recover an unconscious person from the water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 14 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
The owner, managing operator, master or officer in charge of a navigational watch of a towing vessel must ensure the following: The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. The aft tow hook is severely corroded and no longer serviceable, repair or replace the piece of equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. There is no guard provided for the fire monitors power take off unit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 24 September 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 June 2021
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. The galley space and accommodation doors on the vessel were found to be in disrepair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 7 May 2019
Resolved
Vessels of this section that operate on the Great Lakes or outside the Boundary lines, as set forth in 46 CFR part 7, are subject to load line requirements in subchapter E of this section. Vessel is restricted to operating within Apra Harbor until a satisfactory load line survey is completed. 46 CFR 136.250(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2019
Resolution: International load line survey completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 August 2017
Resolved
Remove all oily waste from the bilges and provide copy of receipt of waste oil removal to USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2017
Resolution: Removed approx. 500 gallons of oily water mixture.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2017
Resolved
Remove all oily waste from the bilges and provide copy of receipt of waste oil removal to USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2017
Resolution: Removed approx. 800 gallons of oily water mixture.
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2017
Resolved
Repair all 4 life rings. Replace deteriorated grab lines and life lines with new.
Due 24 August 2017
Resolved 24 August 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 August 2017
Resolved
Float light not working.
Due 22 August 2017
Resolved 24 August 2017
Stability › Weathertight Integrity › General
Issued 22 August 2017
Resolved
Repair dogs on weather tight hatches on main deck; unable to turn due to excessive rust.
Due 22 August 2017
Resolved 24 August 2017
Fire Fighting › Fire Hoses › Location
Issued 22 August 2017
Resolved
Remark all fire hose boxes with the words FIRE HOSE.
Due 22 August 2017
Resolved 24 August 2017
Engineering › Compressed Air System (control) › Compressor
Issued 14 June 2015
Resolved
Vessel lost engine control due to casualty to air system. Informed company rep [name withheld] that the engine casualty must be repair and test to the satisfaction of the attending MI prior to engage in commercial towing.
Action required: 705 - Other - as specified
Resolved 14 June 2015
Resolution: Completed repairs and test on inboard air compressor.
Engineering › Compressed Air System (control) › Compressor
Issued 14 June 2015
Resolved
Outboard air compressor overheats and tripped off line. Repair air compressor IAW manufacture instruction.
Action required: 705 - Other - as specified
Resolved 22 August 2017