MAURY USCG vessel records Sign in
← All vessels

SHAMROCK

SHAMROCK is a 1969 passenger vessel (inspected). The Coast Guard has recorded 153 inspections since 1982, most recently in April 2026, along with 435 deficiencies — 2 with no resolution recorded —, 29 operational controls and 12 casualty investigations between 2011 and 2023.

Records from 1982 to 2026. Most recent: inspection, 21 April 2026.

Built
1969
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE6236
Flag
UNITED STATES
367377680
Maury page id
psix-46149

Inspections, by type

…with no type recorded33
…past their stated due date2
Years with a record 41 calendar years (1982–2026)
The 153 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 16.6 ft × 7.8 ft
Registered tonnagegross 59 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1969
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTANAPAG HARBOR, SAIPAN, MP
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE6236MMSI 367377680 · active · compulsorily equipped · granted 7 September 2018, expires 23 September 2028
WCY6789MMSI 367375130 · expired · voluntarily equipped · granted 29 August 2008, cancelled 3 November 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCK3222MMSI not assigned · expired · compulsorily equipped · granted 28 July 1994, cancelled 2 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TALOFOFO Towing Vessel · MISLE 944367 · 8 September 2022 · activity 7556711PATRIOT Passenger (Inspected) · MISLE 46658 · 13 August 2020 · activity 7032577PATRIOT Industrial Vessel · MISLE 81187 · 1 May 1996 · activity 162099

Inspection history · 153

21 April 2026 Vessel Attendance · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8355018
24 November 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8273601
8 September 2025 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8229074
14 February 2025 In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8081173
11 February 2025 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8077717
12 December 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8047718
30 October 2024 In-Service Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8026807
24 October 2024 Annual Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8007407
9 October 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8016511
2 August 2024 Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7972694
22 November 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7828519
22 November 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7865845
28 September 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7799672
3 August 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7761678
13 March 2023 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7649904
30 December 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7615251
16 September 2022 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7574786
8 September 2022 Damage Survey · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7554600
8 September 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7556711
11 August 2022 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7530435
11 August 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7531264
10 August 2022 Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7541188
6 April 2022 Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7423790
26 January 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7420446
25 January 2022 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7420367
23 August 2021 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7293808
6 August 2021 Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7278703
29 June 2021 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7264003
9 May 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7193186
11 December 2020 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7110003
18 November 2020 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7097420
13 October 2020 Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7075787
13 August 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7032577
5 July 2020 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7000131
7 November 2019 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6861652
28 August 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6797662
7 July 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6739062
6 June 2019 Spot Check · Examination of Repairs · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6705156
9 October 2018 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6562871
28 September 2018 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6550448
24 September 2018 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6546974
29 August 2018 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6526012
6 February 2018 Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6350047
3 January 2018 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6332307
5 November 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6307022
5 November 2017 Administrative Inspection · Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6736590
21 October 2017 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6292070
20 October 2017 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6293767
10 October 2017 In-Service Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6289828
31 August 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255861
31 August 2017 In-Service Inspection · Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255865
16 August 2017 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6243017
16 August 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6244205
8 August 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6235928
3 July 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6197440
25 April 2017 Spot Check · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6138527
7 February 2017 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083770
28 January 2017 In-Service Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6080761
24 January 2017 Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6182898
9 January 2017 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6067768
8 November 2016 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6039894
31 October 2016 Examination of Repairs · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6032951
31 October 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6077381
23 October 2016 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6027991
12 August 2016 Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5965219
8 August 2016 In-Service Inspection · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5966855
18 July 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5948656
27 June 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5935856
27 May 2016 Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5896906
23 May 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5902942
9 May 2016 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5873152
30 April 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5873995
19 March 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5838617
19 March 2016 Examination of Repairs · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5847312
6 January 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5792636
2 November 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5755241
20 July 2015 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5189688
10 August 2014 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7030452
29 September 2011 Deficiency Check · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4160356
17 August 2011 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4118037
15 August 2011 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4110963
15 July 2011 Examination of Repairs · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4081863
8 July 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4136950
16 November 2010 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3891953
1 May 2009 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3466786
10 September 2008 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3321475
23 October 2007 Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3085124
16 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2887569
8 August 2006 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2739549
31 May 2006 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2665549
28 October 2005 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2523658
14 June 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2389830
18 November 2004 Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2243271
1 November 2004 Periodic Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2231892
27 October 2004 MTSA Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2235099
8 September 2004 In-Service Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2189865
25 May 2004 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2077394
15 August 2003 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1883514
8 April 2003 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1769907
27 December 2002 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1732516
7 October 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1687680
20 September 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1678005
6 September 2002 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1668073
22 August 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1376712
16 August 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1387133
2 October 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 822021
25 July 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1369776
5 May 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048630
2 May 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048541
29 March 2000 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1378932
23 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 778915
15 June 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1190343
7 June 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1360939
6 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801168
5 October 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801633
15 August 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 798269
20 July 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1129587
29 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394904
21 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442569
23 May 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 694891
16 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1082731
1 May 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 162099
26 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396510
18 January 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1434357
22 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382992
7 September 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385319
27 July 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374113
19 August 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1389688
13 July 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423804
11 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 80565
17 July 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353384
21 December 1991 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7568
11 October 1991 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 936248
7 August 1991 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1253632
24 July 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 926358
19 July 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1236564
9 July 1990 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1214636
12 December 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1234384
1 November 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 979051
24 June 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 898834
13 June 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 894780
9 June 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 967195
5 April 1989 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1202876
30 November 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1208244
30 May 1988 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1199581
3 December 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002845
29 May 1987 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002412
29 May 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1033349
19 February 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1322522
5 August 1986 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1304849
9 May 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299562
9 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294461
1 November 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275098

Deficiency record · 435

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2026 No resolution recorded
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection, as required in § 176.105 of this part. The operator failed to complete a COI renewal prior to the expiration of the COI. The operator did not submit a written application for renewal 30 days prior to the expiration of the COI. 46 CFR 176.404
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 April 2026 No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. During a damage survey conducted following Typhoon Sinlaku, the vessel SHAMROCK was found to have sustained significant structural damage to the starboard side hull in way of Starboard Void Space No. 3. Damage is consistent with a collision event in which the vessel SUPER EMERALD broke free from its mooring and struck the vessel LEATHERNECK outboard of SHAMROCK, allegedly causing SHAMROCK to be crushed against the dock on its starboard side. The following structural damage was observed: 1. Upper weld seam puncture – between transverse frames 1 and 2, above upper longitudinal frame 1: The deck chine weld seam in Void Space No. 3 starboard was found punctured in the bay between transverse frames 1 and 2, above longitudinal frame 1. The weld exhibited a breach with visible separation of the seam consistent with compressive impact loading. 2. Side shell weld seam puncture – aft of transverse frame 1, between longitudinal frames 1 and 2: An additional puncture to the side shell weld seam was observed aft of transverse frame 1 in the bay between upper longitudinal frames 1 and 2. 3. Longitudinal frame – stitch weld fracture at upper longitudinal frame 2 at the transverse frame 2 intersection, side shell: Found fractured at the junction of longitudinal frame 2 and transverse frame 2 along the side shell, with visible separation of the weld toe and loss of structural continuity at that node. SHAMROCK will proceed to drydock at the earliest practicable opportunity for a complete out-of-water structural assessment and full repair of all collision-related damage identified by the MI. The SHAMROCK is NOT authorized to carry passengers or operate under its Certificate of Inspection until all deficiencies identified herein are corrected to the satisfaction of the attending MI. The vessel may only be operated for the limited purpose of proceeding under its own power to a drydock or repair facility, provided the vessel remains in a seaworthy condition for such transit and the transit is coordinated with MSU Saipan. 46 CFR 176.600 (d)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 December 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts. The overcurrent protection installed to protect the DC emergency circuit is rated for AC current only and does not protect the conductor from an electrical fire. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 1 December 2025
Resolved 10 December 2025
Resolution: All breakers in the DC circuit were replaced with DC rated UL listed 20 amp breakers. All 14 AWG DC conductors are protected by 20 amp breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts. The newly installed breaker panel on the bridge is missing a circuit breaker cover, exposing live conductors to crew members and creating an electrical shock hazard. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
Resolution: The crew placed a circuit breaker cover over the empty space on the breaker panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 November 2025 Resolved
Gauges to indicate jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The port main engine jacket water discharge temperature gauge was not operational when tested. 46 CFR 182.20-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
Resolution: The crew replaced the jacket water temperature sensor and temperature sensor gauge at the helm. The system was tested and found operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2025 Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. The steering hydraulic ram is leaking hydraulic oil when the steering gear is in use. The oil is leaking at a rate of 1/4 cup upon each turn of the steering gear. 46 CFR 182.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2025
Resolved 1 December 2025
Resolution: The crew replaced the hydraulic ram O-rings. The system was tested and was no longer leaking oil.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2025 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. The starboard main engine is missing lagging around the turbo charger, endangering personnel that come into contact with the piping during operation. 46 CFR 182.20-20; 46 CFR 182.15-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 1 December 2025
Resolution: The crew members placed lagging around the turbo chargers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts. The battery charger 10 AWG conductor is taped to a 2 AWG conductor. The connection does not meet regulations and is not enclosed. Furthermore, the conductor is not protected by an overcurrent device. 46 CFR 183.115(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
Resolution: The 2 AWG and 10 AWG conductors were removed and replaced with an 8 AWG conductor from the battery to battery charger. The 8 AWG conductor is protected by a 30 amp breaker. The breaker and conductor connection is inside of a new UL listed breaker panel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 November 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Dive report dated 31OCT24 found 3 inch by 1 inch blade tip damage to one of the starboard propeller blades. Repair or replace starboard propeller to the satisfaction of attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 8 September 2025
Resolution: Deficiency Extended to next drydock, Sep2025. Extended by act 8047718. The propeller was replaced in the 2025 credit dry dock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 October 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel reported a loss of propulsion while underway and subsequent grounding. Vessel was able to return to port and reported no flooding to internal sections of the hull. Provide diver's report to identify any possible underwater damage sustained as a result of the grounding. 46 CFR 177.100 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2024
Resolved 6 November 2024
Resolution: Receieved diver's report dated 31Oct24 which found 3in by 1in damage to stbd prop blade. Performed satisfactory sea trials on 06Nov24. Plans to repair or replace stbd prop asap. CG FM/SEC GUAM to issue a seperate deficiency for stbd prop.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 October 2024 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Vessel reported loosing propulsion due to failure of a control air pressure switch. Perform satisfactory sea-trials to the satisfaction of attending Marine Inspector. 46 CFR 182.30-1 - 17c.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2024
Resolved 6 November 2024
Resolution: Performed satisfactory sea trials. Crew replaced air control valve which keeps steering control air at operating pressure. Control valve found faulty and replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 November 2023 Resolved
Gauges to indicate engine RPM, jacket water temperature, and lubricating oil pressure must be provided for all propulsion engines installed on the vessel. The gauges must be readily visible at the operating station. The stbd main engine's jacket water temperature gauge is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 September 2023 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. The vessel completed a simplified stability test in 2011 IAW 46 CFR 178.330. Page two of the stability letter was not found posted on the vessel. 46 CFR 176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 14 October 2023
Resolution: The second page of the stability letter is posted.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 September 2023 Resolved
IAW 46 CFR 184.115, an existing vessel need not comply with the requirements of § 184.610 until March 11, 2001, or 10 years after its keel was laid or the vessel was at a similar stage of construction, whichever is later. 46 CFR 184.610(e)- On a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, a public address system is not required if a public announcement made from operating station without amplification can be heard throughout the accommodation spaces of the vessel during normal operating conditions, to the satisfaction of the cognizant OCMI. A public address system is required on this vessel and is installed. 46 CFR 183.310- (1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: (i) The vital systems listed in § 182.710 of this chapter; (ii) Interior lighting except for decorative lights; (iii) Communication systems including a public address system required under § 184.610 of this chapter; and (iv) Navigation equipment and lights. The following systems were tested under emergency battery power and were not operational: VHF radio and PA system. 46 CFR 183.310
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 14 October 2023
Resolution: The public address system is connected to emergency DC power. Witnessed the crew test the public address system under emergency power in all passenger spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2023 Resolved
A suitable hull strainer shall be installed for diesel engine cooling in the circulating water intake line. The hull strainer was found leaking water at one drop per 10 seconds. 46 CFR 182.20-10(b)(3)
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 14 October 2023
Resolution: The strainer is no longer leaking and was found in good condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
All wiring shall be run as high as practicable above the bilges. The starting conductors for the main engines and generator were found installed in the bilge. 46 CFR 183.05-50(a)
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 14 October 2023
Resolution: The conductors for the main engine were removed from the bilge and installed along the top of the longitudinal engine bed stringer.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
An electrical system that has any current carrying conductor intentionally connected directly or indirectly to the metal hull shall be subject to additional requirements as determined by the OCMI in subchapter J as per 46 CFR 183.10-30(a). Ground detection for each AC system that has a grounded neutral must have the following equipment that can withstand the max available fault current without damage: An anmeter that: indicates the current in the ground connectino, has a scale that accuratley and with clear definition indicates current in the 0 to 10 ampere range, and an ammeter switch that is the spring return to on type as per 46 CFR 111.05-27. The anmeter installed for ground fault detection is outside of the current range specified in the regulations. The anmeter was not found to be operational when tested. 46 CFR 183.10-30(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2023
Resolved 13 March 2025
Resolution: A new anmeter was found installed at the switchboard and connected to the neutral to ground.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
Batteries connections shall be made to the battery terminals with permanent type connectors. Unapproved butterfly nuts found installed at battery terminals. 46 CFR 183.05-20(c)
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 14 October 2023
Resolution: Permanent connectors were found on all batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. Unapproved welding cable was found installed from the battery switch to the main engine starting battery. 46 CFR 183.115(c) 46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 14 October 2023
Resolution: The welding cable was removed and replaced with 2 AWG marine grade conductors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. A SENS battery charger with a manufacture date of 2019 was found installed onboard without approved electrical plans. Provide approved electrical plans for the new intallation. 46 CFR 183.115(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2023
Resolved 24 October 2024
Resolution: Verified installation IAW MSC approved drawing Dwg. No. SHAMROCK 700-001, Rev.0. Drawing approved by MSC letter dated 22Sep24.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 27 adult lifejackets and 6 child lifejackets were found in poor condition and tore at the collar when tested by bending in hand. Total persons reduced to 24 and no children are permitted. 46 CFR 180.71(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2023
Resolved 24 October 2024
Resolution: Verified all 51 type 1 adult lifejackets and 6 type 1 child lifejackets onboard per COI, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 September 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. One life float paddle was found fractured and is not ready for service. Total persons reduced to 30. 46 CFR 180.175(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 October 2023
Resolved 14 October 2023
Resolution: The life float paddle was replaced with a new paddle like and in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 September 2023 Resolved
Each hatch exposed to the weather must be watertight. Flush deck hatches on the aft main deck were found without gaskets. 46 CFR 171.124(a)
Action required: 705 - Other - as specified
Due 5 October 2023
Resolved 29 September 2023
Resolution: The gaskets for all flush deck hatches on the aft main deck were renewed as original.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2023 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. The operator replaced the previous single phase Delco Generator rated for 240 volts and 25KVA, with a new generator that is manufactured by MagnaPlus and distributed by Marathon Generators. The new generator is a model 283PSL1707, serial MT-0117293-0122, rated for 40 deg C ambient temp, 1800 RPM, 60 Hz, 480 Volts, 3 phase, with an output of 45 amps/30KW. An email was sent to the port engineer in January 2022 stating that if the new generator electrical rating is different than the original then electrical plans must be submitted to MSC for approval. Submit AC electrical plans for the new generator installation to MSC for approval. 46 CFR 183.115(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2023
Resolved 13 March 2025
Resolution: The new electrical plans were submitted to MSC and approved. Serial: E2-2500818
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2023 Resolved
Machinery must be suitable for the vessel and its operations and for the purpose intended. Crew commenced replacement of port & STBD propulsion engines without notify the CG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officerin Charge, Marine Inspection. Repair hole on line connected to bilge suction system in forward engine room compartment to the satisfaction of the attending USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 November 2023
Resolution: Repair completed to the satisfaction of the attending USCG MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Prove operation of bilge suction in lower cabin.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 November 2022
Resolution: Tested operational to the satisfaction of the attending USCG MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Bilge suction line below galley space is not fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 November 2022
Resolution: Corrected to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
Repair holed and wasted potable water supply line on starboard side main deck to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 November 2022
Resolution: Repaired to the satisfaction of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 October 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light comes on intermittently. Repair and prove operation of anchor light to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 November 2022
Resolution: Tested operational to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 October 2022 Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Replace broken wooden paddle due to wood rot with new for 15 x person buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2022
Resolution: Replaced with new to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 October 2022 Resolved
Retroreflective material required by this section must be Type I material that is approved under subpart 164.018 of this subchapter. Replace unapproved reflective tape on ring buoys with USCG approved type in accordance with cite.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2022
Resolution: Replaced with new USCG approved tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2022 Resolved
Each life jacket must be marked with Type I retro-reflective material in accordance with 46 CFR 164.018. Total of 23 x adult and 1 x child personal flotation devices inspected with non-approved USCG reflective tape. Replace with USCG approved reflective tape to the satisfaction of the attending USCG [name withheld] corrective action, vessel is limited to carrying no more than 28 persons including crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Corrected with USCG approved reflective tape the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. (1) Engine room compartment electrical panel must be marked to identify each equipment and amperage that are in use for operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Marked/labeled to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2022 Resolved
Electrical installation shall be to the satisfaction of the OCMI rep. Properly secure loose overhead light fixture above generator in engine room compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Corrected to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2022 Resolved
Electrical installation shall be to the satisfaction of the OCMI rep. Prove operation of port side forward flood light on mast.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Tested to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2022 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Positive and negative electrical wires are wrapped around battery terminals. Properly connect electrical cables to battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Verified each battery cable with terminals properly connected to the battery with side post adapters.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. On August 11, 2022, while the vessel was at Sumay Cove, the vessel suffered a loss of electrical power and the generator main breaker failed to reset. Prior to carrying passengers conduct a causal analysis as to the failure of the electrical system, provide written documentation to the scope of repairs, and effect permanent repairs. Repairs and tests are to satisfaction of the attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: New electrical breaker installed and tested with load to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 August 2022 Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use in fire fighting. The hand portable fire pump may also serve as a bilge pump. Vessel to have and maintain a hand operated portable fire pump in accordance with cite.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 12 October 2022
Resolution: Portable hand pump on board and operated to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 August 2022 Resolved
Verify each electrical panel numbered switching unit and circuit directory are correct and properly labeled in accordance with this cite.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Electrical panel at wheelhouse correctly labeled to the satisfaction of the attending USCG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 August 2022 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Repair or replace with new as to original leaking port side overboard valve in engine room to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Replaced with new to the satisfaction of the attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 August 2022 Resolved
Operational readiness, maintenance and inspection of lifesaving equipment. Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Maintenance, inspections of survival craft and testing of EPIRB are completed in accordance with Subpart and logged or otherwise documented for review by the Coast Guard upon request.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Reviewed vessel's log book and verified monthly tests are documented by crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2022 Resolved
Make repairs to the stbd main engine throttle in the wheel house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 January 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Replace water logged/damaged life floats to as original to the satisfaction of the attending USCG Marine Inspector. Update: 12MAY2022 - Pending new life floats, vessel is prohibited from carrying no more than 10 persons total on each voyage. Vsl has installed a 10 person life float approved by CID.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 June 2022
Resolution: Vessel has 2 x 15 new USCG approved life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 August 2021 Resolved
Vessel must stow the buoyant apparatus in a float free arrangement. Vessel had painted the weak link to the vessel hull.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep removed the paint from the week links.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 August 2021 Resolved
All vessels (old T) are required to be provided with a hand operated portable fire pump having a capacity of 5 gpm. Vessel was missing the portable hand fire pump.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep provided a hand portable fire pump for the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2021 Resolved
The Marine employer must have adequate amount of alcohol testing devices onboard the vessel for the total crew size onboard.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep provided adequate amount of alcohol testing devices for the crew size onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 August 2021 Resolved
Placards containing the instructions for the donning and use of lifejackets onboard the vessel must be posted in conspicuous places that are regulary accessible and visible to the crew and passengers. Vessel was missing the instrucitons for the JIM BUOY life jacket model SO-1.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep provided a new donning placard for the applicable life jacket model.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 August 2021 Resolved
1Vessel must carry an appoved first-aid kit. vessel had expired medications within the first-aid kit.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep replaced all expired onboard medications.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 August 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel had the 2009 edition charts onboard with no weekly NTM updates corrected.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep provided updated cahrts for the intended areas of operation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 August 2021 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. The lighting fixture in the fwd lower compartment was extinguished.
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
Resolution: Vessel rep replaced the extinguised light bulb.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 December 2020 Resolved
While underway on board vessel SHAMROCK to and from a vessel at anchorage, MI observed weathertight/watertight doors remained open during both transits. Vessel is on an Oceans route per COI and stability letter states that all openings remain closed. Vessel is restricted to operating within Apra Harbor, Guam until full compliance is met to the satisfaction of the attending [name withheld] in this part shall be construed as limiting the marine inspector from making such tests or inspections as are reasonable and practicable to be assured of the seaworthiness of the vessel per 46 CFR 176.30-1.
Action required: 705 - Other - as specified
Resolved 23 July 2021
Resolution: New watertight gaskets installed for engine room hatch, man hole cover on main deck on door to lower cabin below main deck. New weathertight gaskets on aft passenger cabin on main deck. Used up to 30psi water pressure via hose for test-all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2020 Resolved
Where fixed seats are installed, the seat spacing shall be such as to provide for ready escape in case of fire or other casualty. Bench seats in main passenger cabin to are not bolted/affixed to the deck to prevent from shifting or turning over. Repair to as original to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2020
Resolved 30 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2020 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. It was reported by the vessel's crew that the vessel's air conditioning unit is inoperable. Openings on deckhouse and to lower passenger cabin are kept open while underway with passengers for hire on board. Repair unit in accordance with manufacturer's recommendation or recommend replacing with new. Electrical installations must be in manufacturer's recommendation or recommend replacing with new. manufacturer's recommendation or recommend replacing with new. Electrical installation of unit must be in accordance with Subpart 183.05-1 or 183.10, respectively.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020 Resolved
Exposed electrical wiring not enclosed in junction box on water pump in forward compartment below crew galley. Remove or cap off exposed electrical wiring from breaker box and loose wiring throughout the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 3 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 October 2020 Resolved
CFR 182.530(a),(c): On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. There is no high water alarm in the lower passenger area, which is normally unmanned. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 October 2020 Resolved
OLD T 46 CFR 171.124(a): Each hatch exposed to the weather must be watertight. There are currently three hatches that were found allowing water access into the spaces; the aft door to the lower passenger area, the aft door to the main passenger area, and the engine room hatches on the main deck. (Restricted to operating within Outer Apra Harbor).
Action required: 705 - Other - as specified
Due 14 November 2020
Resolved 23 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 October 2020 Resolved
OLD T 46 CFR 180.15-5(d): The water light for the life float must be attached to the life float by a lanyard at least 18 feet in length. The current configuration utilizes a corrosion resistant clip so is not directly attached with the lanyard. (Restricted to operating within Outer Apra Harbor).
Action required: 705 - Other - as specified
Resolved 19 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 October 2020 Resolved
OLD T 46 CFR 180.15-5(c): Each life float must be fitted with a painter that is installed to run out freely. Current painter is not able to run out freely to utilize the weak link if vessel were sinking. Install in accordance with manufacturer’s procedures. Vessel is restricted to Lakes, Bays, and Sounds so must remain within inner harbor Guam until corrected. (Restricted to operating within 3 miles from shore).
Action required: 705 - Other - as specified
Resolved 19 October 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 October 2020 Resolved
46 CFR 180.70(d): Each vessel must carry one floating water light with a lanyard securing the water light around the body of the life ring buoy with a corrosion-resistant clip to allow for quick disconnection of the light and lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 October 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 October 2020 Resolved
OLD T 46 CFR 177.35(b)Rails shall consist of evenly spaced courses and the spacing between courses shall not be greater than 12 inches. Replace missing lower course on starboard side aft of house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 October 2020 Resolved
OLD T 46 CFR 183.05-15(c): Each ungrounded conductor of circuits supplying lights shall be equipped with a circuit breaker or switch and fuse at the point of attachment to the power source. Current bathroom light in main passenger cabin is not on a breaker in the main switchboard. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 18 November 2020
Resolution: Wiring properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 October 2020 Resolved
OLD T 46 CFR 183.05-35: Accessories, such as switches, shall be standard National Electrical Code types for the loads to be carried and shall be of types listed by Underwriters’ Laboratories, Inc. or other recognized testing laboratory. Also, for vessels operating on salt water, all lights, receptacles and switches shall be constructed of corrosion resistant material. Passenger cabin wash room has an unapproved electrical installation for operating the toilet. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 3 February 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2020 Resolved
OLD T 46 CFR 185.30-15: All escape hatches and other emergency exits shall be marked on both sides “Emergency Exit, Keep Clear”. Current signage is worn and in need of replacement. (NLT 20NOV2020).
Action required: 705 - Other - as specified
Due 14 November 2020
Resolved 19 October 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 October 2020 Resolved
OLD J 46 CFR 112.05-10 Table 112.05-5 footnote 5, battery operated lanterns used for emergency lighting shall have rechargeable batteries and incorporate an automatic battery charger that will maintain the battery in a fully charged condition. Current emergency lighting installation in crew cabin space is wired on main circuit with main light switch. This allows the control of the charger to be turned on and off with the main light switch and is not in a constant charging position. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 3 February 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2020 Resolved
OLD T 46 CFR 177.30-5(b) All toilets and wash basins shall be fitted with adequate plumbing. The sewage line in crew cabin is taped and not threaded into piping. Also, lower cabin sewage line is leaking. Correctly install plumbing for both locations to avoid sewage leaking into the spaces. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 3 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 October 2020 Resolved
46 CFR 183.420: Navigation Rule #29 indicates that a red all around light below a white all-round light in a vertical line is used for pilot vessels. SHAMROCK has lights mounted for this configuration but the red light is not operational. (NLT 20NOV2020).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 19 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 14 October 2020 Resolved
46 CFR 184.704: A vessel with installed toilet facilities must have a marine sanitation device (MSD) that complies with 33 CFR 159. Vessel has an installed Type III marine sanitation device (MSD) holding tank. Verify Captain’s head is connected to holding tank and is in proper working condition. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 3 February 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2020 Resolved
46 CFR 181.520: Each fire extinguisher must be located so they are clearly visible and readily accessible. Fire extinguisher at lower crew cabin is not properly marked to verify location. Provide Fire Extinguisher placard for location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 18 November 2020
Resolution: Fire extinguisher location verified after flooring was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2020 Resolved
OLD T 46 CFR 176.20-1: The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI. Vessel is a small passenger vessel responsible for passenger and crew safety. Removable wooden deck panels in lower passenger cabin area is deteriorated and with wood rot; deck is unstable which provides a safety hazard to crew and passengers. Wooden bulkhead panel in way of portable fire extinguisher is loose and poses a hazard to crew. Secure side panel and replace wooden deck to original.Prior to replacing with new wooden deck panels, contact USCG MI to inspect bilge below deck prior to repairs. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 18 November 2020
Resolution: Flooring replaced to provide safe working environment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 October 2020 Resolved
OLD T 46 CFR 182.25-10: All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). The portable hand bilge pump shall be provided w/suitable hoses for pumping bilges on the suction and discharge ends. Replace missing portable hand bilge pump and maintain on board vessel. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 15 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2020 Resolved
OLD T 46 CFR 176.20-1: Low water pressure from starboard side garden hose. Repair water pump to starboard side garden to the satisfaction of the attending USCG Marine Inspector. (NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2020
Resolved 3 February 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 October 2020 Resolved
46 CFR 183.220 (d): All electrical equipment and circuits must be clearly marked and identified. Switchboard panels are not properly labeled at operating station and inside engine room compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 18 November 2020
Resolution: Switchboard panels were properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 October 2020 Resolved
OLD T 46 CFR 176.25-50: At each initial and subsequent inspection...the Marine Inspector shall require that all observed unsafe practices and hazardous situations be corrected. Properly secure or remove hanging dead end wires in forward passenger cabin.(NLT 20NOV2020).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 18 November 2020
Resolution: Dead end wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 October 2020 Resolved
Life jackets must be maintained IAW 46 CFR 180.71; replace unapproved whistles with USCG approved, mark life jackets with name of vessel.
Action required: 10 - Deficiency Rectified
Resolved 14 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2020 Resolved
OLD T 46 176.20-1: Hole discovered at port side exterior of house in way of hold back hook. Repair hole on port side wheelhouse to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 October 2020
Resolution: Inspected final repairs of 18 x 18 metal plate insert on port side wheelhouse; witnessed NDT-airlance and inspected port side window installed to as original; witnessed leak test along edge of window using shorside hose. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020 Resolved
Repair port side main propulsion engine prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2020
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 28 August 2019 Resolved
Seat must be constructed to minimize the possibility of injury. Repair damaged seat covers that have sharp edge and exposed seating frames.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 23 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2019 Resolved
Unfinished deck installation in lower passenger cabin. Make permanent repair to lower cabin decks; refasten deck flooring plywood to aluminum frames, re-install deck tiles, and make all fixed seating secure to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 23 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 28 August 2019 Resolved
Install missing cover for electrical outlet in lower cabin portside wall and repair inoperable ceiling light fixtures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 August 2019 Resolved
Repair inoperable overhead light fixtures in engine room and steering space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 August 2019 Resolved
Attach/secure loose overhead ceiling and portside wall in lower passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 23 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 August 2019 Resolved
Repair or replace inoperable port engine temperature gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 August 2019 Resolved
Repair damaged life float (LF) IAW manufacture instructions or replace damaged LF with in-kind LF.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 7 November 2019
Resolution: New 2 x 15 person BAs installed; replaced in kind and inspection point checklist from manufacturer on board to be used by crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2019 Resolved
Replace worn out retro-reflector tape on life ring buoy located outside port bridge door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2019 Resolved
Replace worn out retro-reflector tape on all identified adult & child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 28 August 2019 Resolved
Repair inoperable existing PA system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 August 2019 Resolved
Conduct crew training for MOB and fire drill in GUAM prior to carry passenger. Show proof of previously conducted crew training recorded in Log or other documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 28 August 2019 Resolved
DAPI AUDIT to be conduct in GUAM by SECTOR Guam inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 23 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2019 Resolved
Repair damaged & disconnected electrical wire to starboard engine fuel sensor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 28 August 2019 Resolved
Repair damaged supply vent louvers for air condition supply to lower passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 August 2019 Resolved
Remove standing water in steering space bilge. Locate the source of water intrusion and repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 30 August 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 June 2019 Resolved
46CFR176.25-50: Accumulation of waste oil in engine room bilge. Remove dispose of wast oil IAW federal/state laws. Determine cause of oil leak and make repairs IAW manufacturer's recommendations to prevent further leaks from reoccuring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2019 Resolved
46CFR176.20-1/5: Generator exhaust with unapproved temporary repairs. Remove exhaust lagging for USCG inspection. Prior to repairs, submit repair plan to USCG for review. Upon completion of satisfactory repairs to the attending MI, exhaust must be rewrapped with marine exhuast insulation/heat wrap.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
46CFR182.20-5: Repair port side main engine temperature gauge at operating station and locally in engine room compartment to as original. Prove proper operation to attending MI.
Action required: 705 - Other - as specified
Resolved 23 September 2019
Resolution: New sensor at operating station installed and tested to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
46 CFR 182.20-20: Stbd main engine inboard exhaust bank with missing marine exhaust wrap/insulation. Repair to ensure all exposed parts of exhaust is covered to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018 Resolved
Post number of life jackets for adult and child in passenger cabin.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018 Resolved
Replace missing whistle and lights on life jackets. A total of 51 adult life jackets and 6 child life jackets must be maintained on board per COI.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2018 Resolved
Replace broken float light for buoyant apparatus.
Action required: 705 - Other - as specified
Resolved 19 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2018 Resolved
Replace wasted reflected SOLAS A tape on buoyant apparatus.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 18 October 2018 Resolved
Replace missing mechanical plug for starboard fuel containment on deck.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 October 2018 Resolved
Repair aft watertight door for lower passenger cabin on deck.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 October 2018 Resolved
Replace missing gasket on port and starboard wheelhouse watertight doors.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018 Resolved
Remove expired medications in additional first aid kit and replace with new.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018 Resolved
Remove or properly cap off electrical wires in way of main engine port and starboard alternators.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018 Resolved
Repair broken electrical panel door in engine room compartment.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018 Resolved
Repair electrical junction box on forward bulkhead and in way of fire/bilge pump in engine room compartment.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018 Resolved
Mark in 2 inch block letters fuel vent, fuel line, water line, fuel shut off, etc. on deck.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 October 2018 Resolved
Replace missing battery operated smoke detector in forward crew cabin.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 18 October 2018 Resolved
Replace missing port side bulkhead panel in forward crew cabin.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 October 2018 Resolved
Repair broken overhead light above rack in forward crew cabin.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 October 2018 Resolved
Repair watertight hatch cover for forward anchor locker/peak void to prevent down flooding.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018 Resolved
Prove operation of emergency lights.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 October 2018 Resolved
Vessel allowed to operate per CID until 30OCT2018, pending receipt of new COD. Vsl's COD had expired in June 2018, and had rqsted for new to include Coastwise trade. Previous issued COD only listed Registry.
Action required: 705 - Other - as specified
Due 30 October 2018
Resolved 18 October 2018
Resolution: New COD has Coastwise and Registry.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2018 Resolved
Replace exhaust lagging with new on outboard exhaust bank on starboard main engine prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018 Resolved
Vessel's port side electrical starter for main engine failed to start. Replace starter with new and test to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2018
Resolution: Successfully op tested new electrical starter on port main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2018 Resolved
46 CFR 176.20-1: Replace coupling btwn shaft from hydraulic steering pump to motor with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2018
Engineering › Steering Gear System › Piping
Issued 6 February 2018 Resolved
Tie-rod failure reported.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2018 Resolved
Mark all fuel tank vents, fuel filling lines, water tank vents, etc. on deck in 1" letters.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 January 2018 Resolved
Replace damaged grouding wire on generator with new.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 14 February 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 January 2018 Resolved
Replace remaining unapproved battery cables with new and marine approved cables.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 30 January 2018 Resolved
Repair hydraulic oil supply line on aft bulkhead in engine room to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2018 Resolved
Replace missing microphone in wheelhouse for PA system with new.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2018 Resolved
Repair broken wheelhouse floodlights or replace with new.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2018 Resolved
Mark port side life ring with vessel's name in black letters, 2" high.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 January 2018 Resolved
Submit proof of new tachometer for starboard main engine.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 16 March 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 January 2018 Resolved
Repair electrical panel with missing hinges that attaches to front panel in forward bulkhead in engine room compartment.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2018 Resolved
Show proof of working external lights to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
Engineering › Steering Gear System › Valve
Issued 5 January 2018 Resolved
Pressure gauge needle was missing. Replacement gauge required to determine steering geer system pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2018
Resolution: New pressure gauge installed. 650 psi was noted to be max system pressure.
Operations/Management › Vessel Activity › Other
Issued 5 January 2018 Resolved
CG-835 directed vessel company to provide a written plan to monitor the steering system and steering ram (see scaaned CG-835 in MISLE documents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2018
Engineering › Steering Gear System › Ram
Issued 5 January 2018 Resolved
Install marine grade steering ram (30 days from completion of defiencies 1 & 2). See scanned CG-835 in MISLE.
Action required: 705 - Other - as specified
Resolved 18 October 2018
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2018 Resolved
Electric starter cable for starboard engine observed charred and signs of melting insulation. Renew with proper gauge of USCG approved cable.
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 14 February 2018
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2018 Resolved
Remove dead-end wire in way of starboard engine starter cable.
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 19 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2017 Resolved
46 CFR 176.20-1: Starboard rudder post with unapproved repairs and wastage. Replace with new to as original to the satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2017 Resolved
46 CFR 176.20-1: Vessel suffered steering casualty to port side rudder post. Replace port side rudder post, linkage and ram to as original per approved USCG plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2017
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2017 Resolved
46 CFR 176.20-1: Vessel suffered steering casualty to steering ram; replace ram to as original per approved USCG plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Engineering › Compressed Air System (control) › Piping
Issued 21 October 2017 Resolved
Throttle control air piping under main operating station leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Communications › Alarms/Indicators › Fire Alarm
Issued 21 October 2017 Resolved
Installed smoke detector in passenger cabin inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 October 2017 Resolved
46 CFR 177.900: Repair starboard side guard rail to as original. Temporary repair approved by Command.
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 5 December 2017
Documentation › Certificates/Documents › FCC SSL
Issued 20 October 2017 Resolved
46 CFR 184.502: A vessel must comply with the applicable requirements for any radio installation requirements issued by the FCC as set forth in 47 CFR 80. Vsl equipped with an SSB. Provide proof of operators RR for all potential captains. Captains without an RR are prohibited from operating on an OCEANS route.
Action required: 705 - Other - as specified
Resolved 8 December 2017
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 19 October 2017 Resolved
46 CFR 177.30-5: Repair fresh water pump for washroom to as original and make ready for use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2017
Resolved 5 December 2017
Engineering › Steering Gear System › Valve, Control
Issued 19 October 2017 Resolved
46 CFR 176.30-1: Secure wiring for aft steering controls to as original.
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 5 December 2017
Electrical › Electric Generation Source (service) › Generator
Issued 10 October 2017 Resolved
46CFR176.830: Make repairs to vsl's ship service generator to as original. Replace electrical battery cables with marine approved type. Prior to repairs, submit scope of work to USCG for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Resolution: Load test completed satisfactory.
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2017 Resolved
46 CFR 176.830: Replace oil return hose on starboard side main engine to as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Engineering › Bilge Water Management System › Pump
Issued 10 October 2017 Resolved
46 CFR 176.20-1: Repair fire/bilge pump to as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2017
Resolution: Broken contact in the motor on the centrifugal switch replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 10 October 2017 Resolved
Replace missing exhaust lagging on both banks on starboard main to as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 October 2017 Resolved
46 CFR 183.420: Running lights inoperable. Vessel restricted from operating during limited visibility and at night.
Action required: 705 - Other - as specified
Resolved 8 October 2017
Engineering › Steering Gear System › Power Unit
Issued 31 August 2017 Resolved
Provide repair plan for damage to the port railing and aft steering control station, and make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 31 August 2017 Resolved
Make lazerett space "safe for workers", identify exhaust leaks and make permanent repair.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 6 October 2017
Engineering › Steering Gear System › Power Unit
Issued 16 August 2017 Resolved
Vessel steering system inoperative. Repair to the satifaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 August 2017 Resolved
Replace or repair inoperable single side band.
Due 8 September 2017
Resolved 18 October 2018
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 8 August 2017 Resolved
Repair in-operable smoke detector in main cabin.
Due 8 September 2017
Resolved 10 August 2017
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 8 August 2017 Resolved
Repair holed and wasted port exhaust muffler.
Due 8 September 2017
Resolved 6 October 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2017 Resolved
Install missing hose clamps on port heat exchanger.
Due 8 September 2017
Resolved 10 August 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2017 Resolved
Replace wasted pipe reducer on port engine cooling system.
Due 8 September 2017
Resolved 6 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 8 August 2017 Resolved
Repair oil leak on port engine inboard valves cover.
Due 8 September 2017
Resolved 10 August 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 August 2017 Resolved
Replace old/leaking hydraulic hoses attached to the hydraulic ram.
Due 8 September 2017
Resolved 6 October 2017
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 August 2017 Resolved
Unclogged drain line around hatch to steering space.
Due 8 September 2017
Resolved 10 August 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 August 2017 Resolved
Install missing aft deck rail (Rope).
Due 8 September 2017
Resolved 10 August 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 April 2017 Resolved
46 CFR 182.100: Remove all oily waste (approx. 24 gals) from bilge machinery space. No evidence of water intrusion or leaks from engines. Crew claims that the water came from the rain that occurred earlier in the day when bunkering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Removed to the satisfaction of attending MI.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2017 Resolved
46 CFR 182.100/176.830: Repair leaking sea water coolant line for port side main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2017
Resolution: Satisfactory repaired to attending MI.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 7 February 2017 Resolved
Starboard side engine fuel pump removed to be refurbished; not delivering fuel to engine causing it to unexpectedly shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2017
Resolution: Repairs completed to the satisfactio of MI.
Engineering › Compressed Air System (start air) › Compressor
Issued 28 January 2017 Resolved
Failed head gasket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: Repairs made to the satisfaction of attending MI.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 January 2017 Resolved
46 CFR 182.100: Remove oily waste from bilge. Bilge in engine room must be free of waste oil at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2017
Resolved 24 January 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 January 2017 Resolved
46 CFR 176.700/182.100: Identify cause of oil leaks on starboard main engine and make proper repairs to secure further leaks.
Due 29 January 2017
Resolved 3 February 2017
Resolution: Leaking oil plugs replaced with new. Engergized engines and got underway with no further evidence of leaks.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 24 January 2017 Resolved
47 CFR 80.905: Vessel is on an OCEANS route and is required to be fitted with a SSB radio. Vsl is prohibited from operating on an OCEANS route until corrected.
Action required: 705 - Other - as specified
Resolved 3 February 2017
Resolution: Verified installation of vessel's SSB. Per crew, the SSB was removed and placed in a storage comparment when it separated from its support.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 24 January 2017 Resolved
46 CFR 182.100: Reapir inoperable RPM gage for stbd main propulsion engine at operator's station.
Due 29 January 2017
Resolved 3 February 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 January 2017 Resolved
46 CFR 176.700/182.100: Make premanent repair to stbd side main propulsion engine supply line connected to the salt water pump. Unapproved repair made to elbow on supply line.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 January 2017 Resolved
Found engine room bilge with about 12 inches of waste oil. Engine room bilge must be free of waste oil and fire hazards as required by 46 CFR 176.830. Remove waste oil and oil residue from engine room bilge.
Action required: 705 - Other - as specified
Resolved 10 January 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 January 2017 Resolved
Found STBD engine exhaust pipe leaking exhaust gas.
Action required: 705 - Other - as specified
Resolved 10 January 2017
Engineering › Compressed Air System (start air) › Compressor
Issued 9 January 2017 Resolved
Failed start air compressor
Action required: 705 - Other - as specified
Resolved 10 January 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 December 2016 Resolved
46 CFR 176.830: Bilge found with approximately 3 to 5 gallons of oily water mixture.
Due 9 December 2016
Resolved 9 December 2016
Resolution: Oily waste removed prior to getting underway.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 November 2016 Resolved
46 CFR 183.210: Electrical panels in machinery space must be watertight and be of suitable construction and corrosion-resistant. 46 CFR 183.200 In addition must be installed and maintained to protection passengers, crew, and other persons and vessel from electrical hazards.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 December 2016
Lifesaving › Work Vest › General
Issued 8 November 2016 Resolved
46 CFR 180.78: Additional personal flotation devices to be separated from life jackets as not to be easily confused with that of the life jackets.
Due 30 November 2016
Resolved 9 December 2016
Stability › Watertight Integrity › General
Issued 8 November 2016 Resolved
46 CFR 176.800: Replace signage for lower passenger cabin watertight door to keep closed at all times.
Due 18 November 2016
Resolved 9 December 2016
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 8 November 2016 Resolved
46 CFR 185.700: Alterations made to existing ladder for MOB does not secure the ladder over the rails to prevent it from shifting or coming off.
Due 16 December 2016
Resolved 9 February 2017
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 8 November 2016 Resolved
Submit electrical plan IAW 46 CFR 176.700, for modified electrical distribution with company approval stamp.
Due 16 December 2016
Resolved 22 June 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 October 2016 Resolved
Prove proper operation of installed emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 31 October 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 31 October 2016 Resolved
Prove proper operation of high water alarms.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2016
Resolved 31 October 2016
Communications › Public Address System › Announcing Station
Issued 31 October 2016 Resolved
Prove proper operation of installed deck communications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 31 October 2016
Electrical › Electric Generation Source (service) › Generator
Issued 25 October 2016 Resolved
Immediately remove all wiring from the generator starter not required for the starting of the generator.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2016
Resolved 25 October 2016
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 25 October 2016 Resolved
Replace oiled generator air filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 25 October 2016
Electrical › Electric Generation Source (service) › Generator
Issued 25 October 2016 Resolved
Identify unknown wires previously attached to generator starter and properly install with circuit protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 31 October 2016
Electrical › Electric Generation Source (service) › Generator
Issued 23 October 2016 Resolved
Generator Failure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2016
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2016 Resolved
Loss of oil pressure on ship service generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Load test completed to the satisfaction of attending MI.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 August 2016 Resolved
Port fuel shut off remote valve found inoperable. Repair and prove proper operation. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 August 2016 Resolved
Lazarette high water and audible/visual alarm inoperable. Repair and prove proper operation. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 12 August 2016 Resolved
Remove all oily waste in engine room and lazarette. 46 CFR 176.830.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Lifesaving › Lifefloat › Float Free
Issued 12 August 2016 Resolved
Life floats are not arranged to float free. Lines are fouled. Arrange life floats in accordance with cite. 46 CFR 180.137.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 August 2016 Resolved
Expired batteries for ring life buoys floating lights. Replace with new battery with screw type. 46 CFR 180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 August 2016 Resolved
Expired batteries for life float floating electric waterlights. Replace with new battery with screw type. 46 CFR 180.175
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 August 2016 Resolved
Missing fasteners for port side engine room ventilation ducting access plate. Replace with new. 46 CFR 177.620
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 August 2016 Resolved
Missing ladder for emergency escape in space forward of wheelhouse. Replace with suitable means of egressing from lower level to exit through emergency escape. 46 CFR 177.500(m) Previously written to correct prior to carrying passengers. Facility is fabricating a ladder. New due date issued.
Due 30 August 2016
Resolved 23 August 2016
Resolution: New ladder installed to the satisfaction of attending MI.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 August 2016 Resolved
Make proper repair to 110 volt for SSB and prove proper operation to attending MI. 46 CFR 183.392
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Tested to the satisfaction of the attending MI.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 August 2016 Resolved
Ladder in A/C space not mounted to support frames. Properly mount ladder in A/C room. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 August 2016 Resolved
Missing (17) adult life jackets. As per COI (51) adult life jackets must be carried on board. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 August 2016 Resolved
Original and valid COI must be displayed on board at all times. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Original on board and posted to the satisfaction of the attending MI.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 August 2016 Resolved
Port and starboard life ring buoys must be marked IAW. Missing name of vessel. 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 August 2016 Resolved
Ventilation cover for A/C duct in forward accommodation space not secured. Make proper repairs. 46 CFR 176.830
Due 30 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 August 2016 Resolved
Make proper repairs to watertight aft bulkhead from main deck to lower passenger cabin. Submit repair plan to USCG for review and approval. 46 CFR 179.320
Due 30 August 2016
Resolved 23 September 2016
Resolution: Verified temporary repairs. Permanent repairs to be made at next dry dock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 August 2016 Resolved
Remove all dead end wires: on top of wheel house, inside lower passenger cabin, and above watertight door aft of house. 17AUG16: Operator intends to replace missing spot light to top of wheel house by said due date of 30AUG16.
Due 30 August 2016
Resolved 23 September 2016
Resolution: Corrected to the satisfaction of attending MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 August 2016 Resolved
Portable fire extinguisher (A-II) missing proof of annual service located aft exterior main deck. 46 CFR 176.810
Due 30 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 12 August 2016 Resolved
Missing cover for receptacle in upper passenger cabin. Replace with new appropriate cover. 46 CFR 176.830
Due 30 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Engineering › Fuel Oil Service System › Filter
Issued 12 August 2016 Resolved
Replace bottom petcock valve for port side fuel filter with an approved mechanical plug. 46 CFR 182.455
Due 30 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 12 August 2016 Resolved
Provide proof of manufacturer's instructions for onboard maintenance of life floats. 46 CFR 185.710(d)
Due 30 August 2016
Resolved 23 August 2016
Resolution: Company generated instructions to be carried out per manufacturer's recommendations.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 August 2016 Resolved
No proof of documenting maintenance for emergency, completed drills (MOB and Fire), and voyage plan. 46 CFR 185.503, 520, and 524
Due 30 August 2016
Resolved 23 September 2016
Resolution: Verified drills conducted during annual and inspection of life saving equipment logged.
Personnel › Training › Familiarization Training
Issued 12 August 2016 Resolved
No proof of crew training completed. 46 CFR 185.420
Due 30 August 2016
Resolved 23 September 2016
Resolution: Verified crew knowledge on instructions for fire and MOB drills using portable ladder with platform.
Engineering › Fuel Oil Service System › Hose
Issued 12 August 2016 Resolved
Outstanding deficiency issued in June 2016: replace non-approved hoses on all primary vital systems (i.e. steering, fuel) with approved hose material such as J1942. 46 CFR 182.720
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 August 2016 Resolved
Demonstrate MOB using portable platform to the satisfaction of attending [name withheld] from prior to carrying pax to 30AUG2016, due to inclement weather.
Due 7 November 2016
Resolved 7 November 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 August 2016 Resolved
Navigational charts for intended area of transit not up to date. No proof of local notice to mariners on board. 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Engineering › Bilge Water Management System › Not Operational
Issued 12 August 2016 Resolved
Replace reach rod in chain locker for bilge suction line with new. Functional test to be completed to the satisfaction of the attending MI. 46 CFR 176.804
Due 19 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 August 2016 Resolved
Replace non-apporved masthead light with USCG approved.
Due 19 August 2016
Resolved 17 August 2016
Resolution: Vsl rep proved to attending USCG that installed mast head light is of approved type.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 12 August 2016 Resolved
Secure oil leaks in engine room. Leak along weld and connection on 2-3" pipe that penetrates through aft engine room bulkhead from steering room and leaking steering hose connections.
Due 19 August 2016
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 August 2016 Resolved
Properly install lash to secure grab lines in place due to deteriorated beckets. Properly arrange float free rope to painter cage as per manufacturer's instructions; submit copy of instructions to USCG, and keep identification tag on board and make avble to USCG upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Engineering › Steering Gear System › Ram
Issued 12 August 2016 Resolved
Replace missing hardware with original for steering gear system in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 12 August 2016 Resolved
Replace missing cover for electrical box (float switch) in lazarette. 46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 August 2016 Resolved
Replace missing guard for overhead light in lazarette. 46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Communications › Public Address System › Broadcast Location
Issued 12 August 2016 Resolved
Missing PA system in lower passenger cabin. Passengers are prohibited from entering lower cabin until public announcement system is installed as original and tested to the satisfaction of attending MI. 46 CFR 184.610
Due 30 August 2016
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 August 2016 Resolved
Replace missing bulkhead panels in lower passenger cabin and space forward of wheelhouse. Exposed wiring and service lines. 46 CFR 176.800
Due 30 August 2016
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 August 2016 Resolved
Make permanent repairs to prevent an accidental discharge of oil/water from float drain valve for air compressor located above port side batteries in engine room. 46 CFR 176.800
Due 30 August 2016
Resolved 23 August 2016
Resolution: Corrected to the satisfaction of attending MI.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 12 August 2016 Resolved
Make permanent repairs for port and starboard side alarms to as original. 46 CFR 176.800
Due 30 August 2016
Resolved 23 September 2016
Resolution: Corrected to the satisfaction of attending MI.
Engineering › Pressure Vessel › Marking and Stamping
Issued 12 August 2016 Resolved
Provide documentation for pressure vessel in lazarette and make ready for USCG inspection. 46 CFR 61.10-5
Due 30 August 2016
Resolved 28 September 2016
Resolution: Documentation for pressure received and attached under Documents.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 August 2016 Resolved
Vessel original construction included crew/passenger toilet and washing space. Spaces have been secured for a length of time with waste still on board. Provide schedule of when spaces will be back in operation and removal of wastes.
Due 30 August 2016
Resolved 9 September 2016
Resolution: Vessel conducts short runs within Apra Harbor that are less than 30 minutes. Verified overboard sewage discharge valve is secured.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 8 August 2016 Resolved
Leaking generator exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Repairs complete and operational test with load witnessed by attending MI. All satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 May 2016 Resolved
Remove all exhaust lagging from both the port and stbd main engine and make available for inspection.
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Exhausts removed to transferred to vessel maintenance shop for repairs.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 May 2016 Resolved
Remove all exhaust lagging from both the generator and make available for inspection.
Action required: 705 - Other - as specified
Resolved 15 July 2016
Operations/Management › Pollution › Control of Discharge of Oil
Issued 27 May 2016 Resolved
Repair multiple oil leaks throughout engineroom; remove oil and residues from bilges and make available for inspection.
Action required: 705 - Other - as specified
Resolved 15 July 2016
Resolution: Oily waste removed from bilge space engine room.
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 May 2016 Resolved
Replace non-approved hoses on all primary vital systems (i.e. steering, fuel, etc.) with approved hose material (i.e. J1942).
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 23 September 2016
Resolution: Corrected to the satisfaction of MI.
Engineering › Compressed Air System (control) › Compressor
Issued 19 March 2016 Resolved
Repair control systems leading to Marine Casualty
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 11 April 2016
Resolution: Air compressor was repaired.
Engineering › Compressed Air System (control) › Compressor
Issued 19 March 2016 Resolved
Provide repair proposal for SHAMROCK repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2016
Resolved 5 April 2016
Resolution: Repair proposal submitted.
Lifesaving › Lifefloat › Approval
Issued 6 January 2016 Resolved
Requirements for Out of Water Survival Craft and replacement of Life Floats and Rigid Buoyant Apparatus. See Special Note for guidance and timelines.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 9 May 2016
Resolution: Requirement rescinded.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 November 2015 Resolved
Fire extinguisher equipment shall be exmined and tested. No proof of services conducetd on two portable CO2 in engine room. Provide CG proof of test and service conducted on CO2s. old T 176.25-25
Due 10 November 2015
Resolved 22 November 2015
Fire Fighting › Fire Pumps › Pressure
Issued 2 November 2015 Resolved
The fire pump outlet shall be fitted with a pressure gage. Pump has a damaged pressure gage. Install in-kind pressure gage. Old T 181.10-1
Due 10 November 2015
Resolved 24 November 2015
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 2 November 2015 Resolved
Toilet shall be fitted aith adequate plumbing. Found toilet not secured to doundation. Install toilet as original. old T 177.30-5
Due 10 November 2015
Resolved 24 November 2015
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2015 Resolved
Deck structure must be in original design. Found uninstalled deck frames in lower passenger cabin causing deck to buckle. Insatll deck frame as original. Old t 176.25-5
Due 10 November 2015
Resolved 24 November 2015
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 November 2015 Resolved
Portable CO2 shall be installed with proper mounting bracket. Found uninstalled mounting bracket in lower passenger cabin. Permanentaly install mounting bracket. Old T 181.30-10
Due 10 November 2015
Resolved 22 November 2015
Stability › Watertight Integrity › General
Issued 2 November 2015 Resolved
The door to weather deck must be watertight. Door to lower passenger cabin missing gasket. Install door gasket with permanent adhesive. Old T 171.124
Due 10 November 2015
Resolved 22 November 2015
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2015 Resolved
One ring life buoy must have floating waterlight. Found light on aft ring life buoy not operable. Service light on ring life buoy. Old T 180.30-1
Due 10 November 2015
Resolved 24 November 2015
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 2 November 2015 Resolved
Wash sink port forward main passenger cabin shall be in serviceable condition. Found plumbing to the sink leaking causing rot wood with in space. Old T 176.25-45
Due 10 November 2015
Resolved 22 November 2015
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 November 2015 Resolved
EAP hot-line phone number must be display / post. Missing post hot-line number.
Due 10 November 2015
Resolved 24 November 2015
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 November 2015 Resolved
EPIRB shall be tested monthly. No proof of conducted EPIRB monthly testing. Provide CG official log showing monthly testing of the EPIRB. Old T 185.25-20
Due 10 November 2015
Resolved 24 November 2015
Communications › Alarms/Indicators › Fire Alarm
Issued 2 November 2015 Resolved
Fire protective device shall be tested by operation. Inoperable fire/smoke detector in for crew accommodation. Show proper operation for smoke & fire detection alarm. Old T 176.25-15
Due 10 November 2015
Resolved 22 November 2015
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 November 2015 Resolved
Hatch exposed to weather must be watertight. Drian line to engine room hatches are clogged causing water leak into engine room. Unclogged hatch drainage. Old T 171.124
Due 10 November 2015
Resolved 22 November 2015
Electrical › Lighting (service) › Lighting Fixture
Issued 2 November 2015 Resolved
All electrical installation shall be to the satisfactory of the OCMI. Found port deck light fixture missing light bulbs. Install in-kind light bulbs. 183.01-15
Due 10 November 2015
Resolved 22 November 2015
Communications › Visual Communication › Red Warning Signal
Issued 2 November 2015 Resolved
Reduction gear shall be in proper operating condition. Found inoperable temperature indicator for STBD R/G temperature. Shoe proper operation of the temperature indicator. Old T 176.25-10
Due 10 November 2015
Resolved 22 November 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2015 Resolved
Navigation light shall be in satisfactory condition and fit for service intended. Lens on mast light restrict visibility. Repair mast light as original. Old T 176.25-40
Due 10 November 2015
Resolved 22 November 2015
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 November 2015 Resolved
Electrical panel shall be in safe electrical condition. Missing breaker in electrical panel in engine room. Properly seal slot or install missing breaker. 176.25-15
Due 10 November 2015
Resolved 24 November 2015
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 November 2015 Resolved
Machinery shall be in proper operating condition. Disconnected oil pressure sensor for port engine. repair as original. Old T 176.25-10
Due 10 November 2015
Resolved 24 November 2015
Stability › Watertight Integrity › General
Issued 2 November 2015 Resolved
Unsafe practice or hazardous condition shall be corrected. Found accumulation of an unknown liquid in bilge for lower passenger cabin. Permanently secure the source of bilge liquid and remove liquid from the bilge. 176.25-50
Due 10 November 2015
Resolved 22 November 2015
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 November 2015 Resolved
Panel box shall be fitted with permanent sign warning indicating 220 Volts and identifying circuits to be disconnected to remove all potentials in excess of 24 volts. Old T 183.10-10
Due 10 November 2015
Resolved 24 November 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2015 Resolved
All wiring and cables shall be suitable for marine service. Wires for aft deck PA speaker has been splice and connected with twist on cap. Make wire splicing moisture & wet proof. Old T 183.10-20
Due 10 November 2015
Resolved 24 November 2015
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 2 November 2015 Resolved
Washing space shall be in serviceable and sanitary conditions. Sink in galley is not properly installed and in poor condition. Repair as original. Old T 176.25-45
Due 10 November 2015
Resolved 24 November 2015
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 2 November 2015 Resolved
Galley space shall be in serviceable and sanitary conditions. Damage tiles on sink counter table. repair as original. Old T 176.25-45
Due 10 November 2015
Resolved 24 November 2015
Engineering › Compressed Air System (start air) › Control Gear
Issued 2 November 2015 Resolved
Engine starting system shall be in proper operating condition. Pressure limit switch on start air compressor is missing protective cover which exposed the internal electrical connection to moisture/soot/heat. Repair as original. Old T 176.25-10
Due 10 November 2015
Resolved 24 November 2015
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 2 November 2015 Resolved
Cooling system for main propulsion machinery shall be in proper operating condition. Found temporary patch on port engine salt water discharge pipe. make permanent repair as original. Old T 176.25-10
Due 10 November 2015
Resolved 24 November 2015
Engineering › Compressed Air System (control) › Hose
Issued 2 November 2015 Resolved
STBD reduction gear shall be in proper operating condition. Found air hose to STBD R/G disconnected with bolt screw into end fitting. Repair as original. Old T 176.25-10
Due 10 November 2015
Resolved 24 November 2015
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 2 November 2015 Resolved
Expansion tank for generator shall be in proper operating condition. Found electrical level indicator with expose internal wiring connection. Repair as original. Old T 176.25-10
Due 10 November 2015
Resolved 24 November 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 November 2015 Resolved
Part of exhaust system between the point of cooling water injection and the engine manifold shall be insulated. Missing insulation on exhaust pipes for port & STBD engines. Install insulations. Old T 182.15-15
Due 10 November 2015
Resolved 23 September 2016
Resolution: Corrected to the satisfaction of MI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2015 Resolved
Rails shall consist of evenly spaced course. Unable to connect aft port rope link to the post. Repair as original. Old T 177.34
Due 10 November 2015
Resolved 27 May 2016
Resolution: Corrected.
Engineering › Steering Gear System › Actuator
Issued 2 November 2015 Resolved
Vessel shall be provided with suitable steering apparatus. Found hydraulic oil leaking from steering wheel hub. Repair as original. (Old T 182.30-1
Action required: 705 - Other - as specified
Resolved 27 May 2016
Resolution: Corrected.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 7 October 2011 Resolved
Remove excessive oil from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2011
Resolution: Engine room bilge pumped.
Engineering › Fuel Oil Service System › Filter
Issued 15 August 2011 Resolved
Repair leak on starboard Racor filter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2011
Resolution: Filter seals replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 15 August 2011 Resolved
Remove excessive oil from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2011
Resolution: Bilges pumped.
Lifesaving › Lifebuoys › Not on Board
Issued 15 August 2011 Resolved
Provide (1) 26" ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2011
Resolution: New ring provided.
Fire Fighting › Fire Main › Condition
Issued 15 August 2011 Resolved
Cap off old fire pump pipe leading to the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2011
Resolution: Pipe capped.
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 August 2011 Resolved
Provide means to keep passenger count ashore while on Limited C/W or less yoyages.
Due 17 August 2011
Resolved 17 August 2011
Resolution: Passenger count information provided.
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 August 2011 Resolved
Provide means to keep crew/passenger list-voyage plan ashore while on Coastwise or Ocean voyages.
Due 17 August 2011
Resolved 17 August 2011
Resolution: Crew/passenger list/voyage plan recall phone numbers provided.
Construction/Loadline › Hull › Hull Plating
Issued 15 August 2011 Resolved
Provide repair proposal for wasted hull plating IWO galley on the port side.
Due 22 August 2011
Resolved 7 October 2011
Resolution: Wasted hull plating cropped and renewed.
Construction/Loadline › Hull › Stiffener
Issued 15 August 2011 Resolved
Repair fractured welds in the forepeak, port side IWO inset.
Due 22 August 2011
Resolved 7 October 2011
Resolution: Fractured welds repaired.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 15 August 2011 Resolved
Repaired fractured welds on storm rail bracket, port side, forward.
Due 22 August 2011
Resolved 7 October 2011
Resolution: Storm rail repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 August 2011 Resolved
Provide 18' lanyard on lifeflost waterlights.
Due 22 August 2011
Resolved 10 October 2011
Resolution: 18'' lanyard provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 August 2011 Resolved
Post EAP hotline phone number.
Due 22 August 2011
Resolved 7 October 2011
Resolution: EAP hotline phone number posted.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 August 2011 Resolved
Repair generator expansion tank fill pipe and make deck penetration watertight.
Due 22 August 2011
Resolved 7 October 2011
Resolution: Fill pipe repaired and deck penetration made watertight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 August 2011 Resolved
Renew expired medications in first aid kit.
Due 29 August 2011
Resolved 15 August 2011
Resolution: New first aid kit provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 August 2011 Resolved
Program MMSI into DSC radio.
Due 29 August 2011
Resolved 14 October 2011
Resolution: MMSI programmed into DSC radio.
Construction/Loadline › Structures › Scuttle
Issued 15 August 2011 Resolved
Make galley hatch/port light weather tight.
Due 29 August 2011
Resolved 10 October 2011
Resolution: Galley hatch and port light made weather tight.
Construction/Loadline › Structures › Door
Issued 15 August 2011 Resolved
Make aft accommodation doors weather tight.
Due 29 August 2011
Resolved 15 August 2011
Resolution: Doors weather tight.
Engineering › Bilge Water Management System › Strainer
Issued 15 August 2011 Resolved
Provide strainer for bilge suction in forward A/C space.
Due 29 August 2011
Resolved 7 October 2011
Resolution: Strainer installed.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 August 2011 Resolved
Re-route temperature gauge wires on both MDEs.
Due 29 August 2011
Resolved 10 October 2011
Resolution: MDE temperature guage wires re-routed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 August 2011 Resolved
Place name of vessel and hailing port on stern of vessel.
Due 29 August 2011
Resolved 10 October 2011
Resolution: Hailing port placed on stern of vessel.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 August 2011 Resolved
Provide cover for electrical junction box in forward head.
Due 29 August 2011
Resolved 15 August 2011
Resolution: Cover installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2011 Resolved
Make proper wire splices in electical breaker panel.
Due 29 August 2011
Resolved 15 August 2011
Resolution: Proper splices made.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 August 2011 Resolved
repair light in forward birthing.
Due 29 August 2011
Resolved 15 August 2011
Resolution: Light repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 August 2011 Resolved
Repair leak on starboard MDE exhaust at wye.
Due 29 August 2011
Resolved 7 October 2011
Resolution: Leak repaired.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 August 2011 Resolved
Provide magnetic compass deviation table.
Due 15 September 2011
Resolved 14 October 2011
Resolution: Magetic compass deviation table provided.
Engineering › Bilge Water Management System › Pump
Issued 15 August 2011 Resolved
Provide self priming bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2011
Resolution: Installed bilge pump had foreign material in the pump housing and the housing was cracked. The pump housing was replaced and tested satisfactory.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 August 2011 Resolved
Repair starboard tachometer, water temperature and oil pressure gauges.
Due 15 September 2011
Resolved 10 October 2011
Resolution: Gauges repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 15 August 2011 Resolved
Provide fully operational bilge main system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2011
Resolution: Bilge main tested satisfactorily until new self priming bilge pump can be installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2010 Resolved
Main deck forward light fixture missing light bulb, leaving open socket. Replace bulb.
Due 30 November 2010
Resolved 3 December 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 16 November 2010 Resolved
Replace retro-reflective material on PFDs as needed.
Due 30 November 2010
Resolved 3 December 2010
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 16 November 2010 Resolved
Provide a total of 51 adult Type I PFDs onboard. Vsl restricted to not more than 49 persons onboard.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 November 2010 Resolved
Esnure all portable fire extinguishers are serviced annually.
Due 30 November 2010
Resolved 3 December 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 16 November 2010 Resolved
Install additional grab/safety lines on starboard side main deck.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 December 2010
Lifesaving › Lifefloat › Painter
Issued 16 November 2010 Resolved
Make lifefloat(s) painter arrangement so painter can pay out freely. *Vessel restricted to Lakes, Bays, and Sounds route until corrected.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 16 November 2010 Resolved
Repair gooseneck vent (missing flange bolts) on starboard side, main deck, forward.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2010 Resolved
Open light bulb sockets in light fixture in crew head. Replace.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electric Supply System (service) › Cable
Issued 16 November 2010 Resolved
Ensure electrical connections in vicinity of AC compressor are per regulations.
Due 30 November 2010
Resolved 3 December 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 November 2010 Resolved
Close MSD overboard valve.
Due 16 November 2010
Resolved 3 December 2010
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 November 2010 Resolved
Install correct means to cap fuel cap in aft fuel tank fill port.
Due 30 November 2010
Resolved 3 December 2010
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 16 November 2010 Resolved
Remove or properly store all flammables (paint, paint thinner) onboard.
Due 30 November 2010
Resolved 3 December 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2010 Resolved
Ensure first aid kit has all required items and are within expiration date.
Due 30 November 2010
Resolved 3 December 2010
Engineering › Compressed Air System (control) › Piping
Issued 16 November 2010 Resolved
Replace air hose on starboard main diesel engine air compressor.
Due 30 November 2010
Resolved 3 December 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 November 2010 Resolved
Repair aft fuel tank remote closure.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2010 Resolved
Determine use and ensure proper circuit protection for small wires attached to battery.
Due 30 November 2010
Resolved 15 August 2011
Resolution: Small wires removed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 November 2010 Resolved
Repair lagging on exhaust systems as needed.
Due 30 November 2010
Resolved 20 May 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 November 2010 Resolved
Ensure 100 amp breaker on main S/B is properly sized for generator.
Due 30 November 2010
Resolved 10 December 2010
Resolution: Per info provided by company electrican, generator is rated for 25 KVA, 104 Amps @ 240VAC
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 16 November 2010 Resolved
Clean all bilge strainers (coated in oil).
Due 30 November 2010
Resolved 10 December 2010
Resolution: Sat tested bilge system from all spaces o/b.
Engineering › Bilge Water Management System › Pump
Issued 16 November 2010 Resolved
Demonstrate ability to draw suction from all spaces with bilge pump.
Due 30 November 2010
Resolved 10 December 2010
Resolution: Sat tested bilge system from all spaces o/b.
Communications › Public Address System › Audio Distribution System Silencing
Issued 16 November 2010 Resolved
Install Public Address speaker in forward accomodation.
Due 30 November 2010
Resolved 3 December 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 16 November 2010 Resolved
Properly hang/secure air system pipes in machinery space overhead.
Due 30 November 2010
Resolved 10 December 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 16 November 2010 Resolved
Repair starboard main engine tachometer.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 November 2010 Resolved
Replace metal bands on electrical wire/cables where cutting into insulation.
Due 30 November 2010
Resolved 10 December 2010
Deck/Cargo › Cargo Transfer (solid) › General
Issued 16 November 2010 Resolved
Submit information on boom use, weight testing, and impact on vessel stability.
Due 30 November 2010
Resolved 15 August 2011
Resolution: Boom removed.
Construction/Loadline › Structures › Scuttle
Issued 16 November 2010 Resolved
Repair forepeak scuttle and make watertight. Vessel restricted to Lakes, Bays, and Sounds until corrected.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Construction/Loadline › Structures › Scuttle
Issued 16 November 2010 Resolved
Ensure lazarette hatch and all aft main deck hatches watertight. Vessel restricted to Lakes, Bays, and Sounds until corrected.
Action required: 705 - Other - as specified
Resolved 10 December 2010
Resolution: Dogs installed, tested sat w/water hose.
Lifesaving › Lifefloat › Markings
Issued 16 November 2010 Resolved
Relabel vessel name on ring buoys and life floats as needed.
Due 30 November 2010
Resolved 10 December 2010
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 16 November 2010 Resolved
Start logging monthly EPIRB testing.
Due 30 November 2010
Resolved 3 December 2010
Engineering › Steering Gear System › Ram
Issued 16 November 2010 Resolved
Correct excessive play in steering ram connection.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 16 November 2010 Resolved
Repair electrical outlet (damaged) in forward AC/MSD/water tank space.
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 September 2008 Resolved
Repair/properly cover exposed wires in wheelhouse overhead, portside.
Due 24 September 2008
Resolved 24 September 2008
Documentation › Certificates/Documents › FCC SSL
Issued 10 September 2008 Resolved
Provide correct radio station authorization (license) for inspected "compulsory" vessels. (i.e. "SB" -Ships Compulsory instead of "SA"-recreational/voluntary).
Due 24 September 2008
Resolved 24 September 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 September 2008 Resolved
Provide current COD onboard. (MISLE shows vsl has valid COD, but O/O claims they haven't rcvd it).
Due 24 September 2008
Resolved 12 September 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 September 2008 Resolved
Update emergency broadcast placard with correct call sign.
Due 24 September 2008
Resolved 24 September 2008
Lifesaving › Lifefloat › Painter
Issued 10 September 2008 Resolved
Repair/replace sun rotted section on life float(s) painter lines.
Due 24 September 2008
Resolved 24 September 2008
Construction/Loadline › Structures › Scuttle
Issued 10 September 2008 Resolved
Repair fore peak WT hatch so it can be made water-tight and install captive chain. Vessel restricted to LBS until corrected.
Due 24 September 2008
Resolved 12 September 2008
Engineering › Bilge Water Management System › Valve
Issued 10 September 2008 Resolved
Repair fore peak remote bilge suction valve.
Due 24 September 2008
Resolved 24 September 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 October 2007 Resolved
Sewage discharge. Lock shut and remove cond discharge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 24 October 2007
Resolution: Disconnected a/c discharge from holding tank.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 October 2007 Resolved
Add two (02) light bulbs to open sockets in head.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 24 October 2007
Resolution: Two lights bulbs were installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 October 2007 Resolved
Repair saltwater leak port MDE exhaust cooling.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Salt water leak has been repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 October 2007 Resolved
Stbd MDE inboard exhaust manifold bolt broken and leaking exhaust.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessels reps removed broken stud and re-installed new exhaust manifold bolt.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 24 October 2007 Resolved
Hydraulic motor engine room repair cage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessel reps installed cage over open motor, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2007 Resolved
Hang wire runs with steel hanger 1 per 24".
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessels reps installed all steel hangors through out the vessel.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 23 October 2007 Resolved
Replace salt water psi gauge on a/c colling pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Gauge has been replaced.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 23 October 2007 Resolved
A/C amp gauge for SSDG panel needs replacement.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessel reps removed broken gauge and re-installed new gauge, tested sat.
Construction/Loadline › Structures › Door
Issued 23 October 2007 Resolved
Repair watertight doors gaskets and dogs.
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessels reps replaced dogs, and replaced the gasket material on the bridge doors. All sat.
Engineering › Fuel Oil Service System › Filter
Issued 23 October 2007 Resolved
Gen set racor filter missing fire protection bowl.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessel reps installed new steel bowl on the gen set racor filter.
Construction/Loadline › Hull › Transverse Frame
Issued 23 October 2007 Resolved
Repair five (05) fractures marked in aft steering.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 13 November 2007
Resolution: Vessel reps repaired all fractures, with sat results.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 August 2006 Resolved
Have all portable fire extinguishers serviced.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 17 August 2006
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 17 August 2006 Resolved
Remove all oil from vessel's bilges.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 17 August 2006
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 17 August 2006 Resolved
Ensure all installed lighting is operating properly.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Stability › Watertight Integrity › General
Issued 17 August 2006 Resolved
Remove and cap hydraulic hoses in fwd L.L. berthing area.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Engineering › Compressed Air System (start air) › Piping
Issued 17 August 2006 Resolved
Secure air hose in lazarette.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Engineering › Steering Gear System › Piping
Issued 17 August 2006 Resolved
Secure hydraulic hoses for steering system.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 17 August 2006
Stability › Watertight Integrity › General
Issued 17 August 2006 Resolved
Secure deck hatch, portside, lazarette tightly to make weather tight.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 August 2006 Resolved
Replace all fantail safety rail lines with new line.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 August 2006 Resolved
Replace all corroded shckles for safety rail lines.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 17 August 2006 Resolved
Install securing device for "knife" transfer switch box, aft bulkhead engine room.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 17 August 2006 Resolved
Provide a sling or harness to retreive a man-overboard.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 17 August 2006 Resolved
Replace all corroded/rotten battery boxes.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Construction/Loadline › Structures › Air Pipe
Issued 17 August 2006 Resolved
Cap/plug bulkhead opening, fantail that leads to head.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Lifesaving › Buoyant Apparatus › Float Free
Issued 17 August 2006 Resolved
Make all lifering lines easily deployable.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 August 2006 Resolved
Remove and clean all bilge strainers.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 17 August 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 8 August 2006 Resolved
Secure high water alarm in lazarette.
Due 17 August 2006
Resolved 17 August 2006
Construction/Loadline › Penetrations › Gasket
Issued 8 August 2006 Resolved
Install securing devices on engine room hatch (small) and lazarette hatch to prevent from falling on personnel.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 October 2005 Resolved
Repair emergency lighting in salon.
Due 14 November 2005
Resolved 21 November 2005
Engineering › Steering Gear System › Piping
Issued 28 October 2005 Resolved
Repair air line fitting on steering system.
Due 14 November 2005
Resolved 21 November 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 28 October 2005 Resolved
Install MSD vent pipe to vent to atmosphere.
Due 14 November 2005
Resolved 21 November 2005
Electrical › Electric Generation Source (service) › Switch
Issued 1 November 2004 Resolved
Remove/repair broken generator control switch.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 15 June 2005
Resolution: Completed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 November 2004 Resolved
Lock/secure MSD door to prevent accidental discharge when within 3 miles of shore.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 15 June 2005
Resolution: Completed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 November 2004 Resolved
Remove old MSD holding tank from engine room.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 15 June 2005
Resolution: Completed.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 August 2003 Resolved
Repair/replace watertight gasket on fwd accomodation space emergency escape.
Due 29 August 2003
Resolved 1 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 August 2003 Resolved
Install guard over generator fly wheel.
Due 29 August 2003
Resolved 1 November 2004
Documentation › Certificates/Documents
Issued 6 September 2002 Resolved
Provide proof of EPIRB registration.
Due 1 October 2002
Resolved 7 October 2002
Resolution: EPIRB Registered.
Operations/Management › Drills/Instruction
Issued 6 September 2002 Resolved
Perform and log monthly EPIRB tests.
Due 1 October 2002
Resolved 20 September 2002
Fire Fighting
Issued 6 September 2002 Resolved
Prove annual servicing of all portable fire extinguishers.
Due 1 October 2002
Resolved 7 October 2002
Resolution: Portable extinguishers serviced.
Engineering › Fuel Oil Service System
Issued 6 September 2002 Resolved
Replace all plastic plugs on Racor flame impingement bowls with metallic plugs.
Due 20 September 2002
Resolved 20 September 2002
Engineering › Bilge Water Management System
Issued 6 September 2002 Resolved
Obtain and put on board a portable hand bilge pump with sufficient length of hose to pump out any compartment.
Due 20 September 2002
Resolved 20 September 2002
Engineering › Bilge Water Management System
Issued 6 September 2002 Resolved
Post bilge manifold diagram or properly label manifold valves.
Due 20 September 2002
Resolved 20 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 6 September 2002 Resolved
Install "rail" across stern section and on side sections of vessel to prohibit passenger access.
Due 20 September 2002
Resolved 20 September 2002
Navigation
Issued 25 July 2000 Resolved
Update the Tanapag Harbor chart to include the latest changes to the channel buoys.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Engineering
Issued 25 July 2000 Resolved
Electrically bond the flexible fuel hose to the metallic fuel fill piping on the aft, port fuel tank.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Navigation
Issued 25 July 2000 Resolved
Install fastening hardware connecting the hydraulic steering ram yoke assembly to the steering tiller.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Lifesaving
Issued 25 July 2000 Resolved
Provide a watertight and bright in color container for the storage of the distress signals.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Navigation
Issued 25 July 2000 Resolved
Provide the latest edition of the 1972 COLREGS for the vessel.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Navigation
Issued 25 July 2000 Resolved
Provide an electronic position fixing device for the vessel. The vessel's route is restricted to not more than 20 miles from shore until completion.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Engineering
Issued 2 May 2000 Resolved
Properly insulate all four turbochargers on both main engines.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 2 May 2000 Resolved
Repair or renew B-II fire extinguisher located on aft weather deck.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 2 May 2000 Resolved
Clean all oil and fuel from engine room bilges.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Lifesaving
Issued 29 March 2000 Resolved
Post signs, port and starboard after deck restricting passenger access to outboard sides of vessel.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Engineering
Issued 29 March 2000 Resolved
Replace all worn lagging on engine exhaust lines in engineroom.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Construction/Loadline
Issued 29 March 2000 Resolved
Gouge out, drill stop, prepare and reweld the recurring hairline fracture, main deck bow, in way of cabin forward starboard corner.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Construction/Loadline
Issued 7 June 1999 Resolved
Prove proper operation for closure of weatherdeck hatches.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 7 June 1999 Resolved
Renew hydrostatic release for EPIRB, until such time vessel is restricted to no more than three miles from shore.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 7 June 1999 Resolved
Replace gaskets on all hatch closures.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Engineering
Issued 7 June 1999 Resolved
Replace/renew 90 degree elbow on fuel vent piping, until such time, vessel may not operate with passengers on board.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 7 June 1999 Resolved
Double hose clamp fwd bilge suction hose.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Navigation
Issued 7 June 1999 Resolved
Identify and repair leak in hydrolic steering line.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Fire Fighting
Issued 7 June 1999 Resolved
Show proof of service for all portable fire extinguishers. If proof can notbe provided, all extinguishers must be serviced.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Engineering
Issued 7 June 1999 Resolved
Repair remote fuel shut-off valve.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Electrical
Issued 7 June 1999 Resolved
Prove operation of emergency lighting.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 7 June 1999 Resolved
Remove all free standing fuel in fuel tank space, until such time, vessel may not operate with passengers onboard.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 20 July 1998 Resolved
Provide adequate stowage for the lifejackets located in the lower passengerarea.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 20 July 1998 Resolved
Renew expired hydrostatic release unit for EPIRB.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Documentation
Issued 20 July 1998 Resolved
Obtain a valid FCC Communications Act Safety Radiotelephony Certificate.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 20 July 1998 Resolved
Obtain and place on board a vessel log to log required drills, passenger count, etc.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 20 July 1998 Resolved
Obtain a watertight container for vessel's pyro distress signals.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 20 July 1998 Resolved
Obtain updated charts and publications for the vessel's area of operation.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Construction/Loadline
Issued 20 July 1998 Resolved
Identify and mark bilge valve located beneath the water storage tank located in the a/c space.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Documentation
Issued 20 July 1998 Resolved
Obtain a valid FCC Station License.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Unknown
Issued 20 July 1998 Resolved
Install a public address system in the passenger spaces.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Construction/Loadline
Issued 20 July 1998 Resolved
Provide more secure deck plating in the a/c space.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Electrical
Issued 20 July 1998 Resolved
Install/repair existing lighting in both passenger spaces.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Construction/Loadline
Issued 20 July 1998 Resolved
Clear area around the bilge suction strainer located aft in the lower passenger space. Remove all debris from the cabin space bilge.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Accommodation/Occupational Safety
Issued 20 July 1998 Resolved
Secure all seating to deck or bulkhead to preclude shifting during heavy seas.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Deck/Cargo
Issued 20 July 1998 Resolved
Obtain an anchor of sufficient size for the vessel.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Fire Fighting
Issued 20 July 1998 Resolved
Obtain an adequate hose to use as a firefighting hose on board the vessel.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 26 April 1996 Resolved
INSTALL LIFERAFTS PRIOR TO CARRING PASSENGERS OR CARGO.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Engineering
Issued 26 April 1996 Resolved
STOP THE OIL LEAK ON THE PORT MAIN ENGINE REDUCTION GEARS SECELTOR.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Navigation
Issued 26 April 1996 Resolved
STOP THE OIL LEAK ON THE STEERING PUMP.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Engineering
Issued 26 April 1996 Resolved
FIX THE LEAK IN THE GENERATOR EXHAUST PIPE AND THE MAIN ENGINE TURBO.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Navigation
Issued 26 April 1996 Resolved
FIX THE RADIO TO SENT AND RECEIVE.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Electrical
Issued 26 April 1996 Resolved
FIX OR REMOVE THE SPOT LIGHT.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Lifesaving
Issued 26 April 1996 Resolved
REMOVE OIL & WATER FROM ENGINE ROOM AND STERN COMPARTMENT.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Electrical
Issued 18 January 1996 Resolved
Have the generator cleaned prior to operating.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 17 July 1992 Resolved
Conduct fire and rescue drill in the presence of the U. S. Coast Guard.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Navigation
Issued 19 July 1990 Resolved
REPAIR PORT RUDDER POST SUPPORT WHERE FRACTURED.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Engineering
Issued 19 July 1990 Resolved
PROVIDE PROPER RELIEF VALVE FOR S/S AIR TANK IN LAZERETTE.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Accommodation/Occupational Safety
Issued 19 July 1990 Resolved
PROVIDE 3/4 FULL INDICATING DEVICE FOR SEWAGE HOLDING TANK. VESSEL LIMITEDTO TRIPS OF 30 MINUTES UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Fire Fighting
Issued 19 July 1990 Resolved
PROVIDE PROPER HAND FIRE PUMP AND PROVE OPERATION.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Electrical
Issued 19 July 1990 Resolved
PLACE COVER OVER WIRING WHERE WIRE CROSSES THRU HATCH OPENING OF ENG ROOM TO PREVENT WEARING OF WIRE.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Lifesaving
Issued 19 July 1990 Resolved
PROVIDE SEPERATE STOWAGE FOR CHILDS LIFE PRESERVERS.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Engineering
Issued 19 July 1990 Resolved
REPAIR/REPLAACE TACHOMETER STBD MAIN ENG.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Engineering
Issued 19 July 1990 Resolved
REPAIR STBD MAIN ENG R/W PUMP
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Lifesaving
Issued 19 July 1990 Resolved
LABEL FWD EMERGENCY ESCAPE HATCH (INTERNALLY).
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Accommodation/Occupational Safety
Issued 19 July 1990 Resolved
PROVIDE SAFETY RAILS ON ELECTRIC STOVE.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Lifesaving
Issued 9 June 1989 Resolved
PROVIDE TWO CHILD CG APPROVED TYPE I LIFE PRESERVERS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 9 June 1989 Resolved
PASSENGER ALLOWANCE REDUCED TO 6 UNTIL 10 MAN LIFERAFT IS REPLACED WITH 20 MAN RAFTS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 5 April 1989 Resolved
REPLACE THE GLASS IN THE FORWARD PORTHOLE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Accommodation/Occupational Safety
Issued 30 May 1988 Resolved
INSTALL ADEQUATE RAILS AROUND PERIPHERY OF WEATHER DECK.
Condition: Unknown
Due 30 May 1988
Resolved 30 May 1988
Accommodation/Occupational Safety
Issued 30 May 1988 Resolved
INSTALL ADEQUATE AND PROPERLY MARK EMERGENCY ESCAPE FOR AFT ACCOMODATION SPACES.
Condition: Unknown
Due 30 May 1988
Resolved 30 May 1988
Lifesaving
Issued 30 May 1988 Resolved
INSTALL APPROVED WATER LIGHTS ON SURVIVAL SUITS (EXPOSURE SUITS).
Condition: Unknown
Due 30 May 1988
Resolved 30 May 1988
Lifesaving
Issued 9 May 1986 Resolved
LABEL LIFE PRESERVERS STORAGE AREAS, IN ACCORDANCE WITHY 46 CFR 180.25-15 (B).
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Lifesaving
Issued 9 May 1986 Resolved
PROVIDE PERMANENT STOWAGE AREA FOR LIFE PRESERVERS.
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Accommodation/Occupational Safety
Issued 9 May 1986 Resolved
PROVIDE FUEL SHUTOFF VALVE FOR LENNOX HEATING UNIT IN ACCORDANCE WITH 46 CFR182.20-40(B)(3).
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Accommodation/Occupational Safety
Issued 9 May 1986 Resolved
PROVIDE COAST GUARD APPROVED TYPE II OR III MARINE SANITATION DEVICE PRIOR TO PLACING TOILETS IN SERVICE.
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986

Casualty record · 12

8 July 2011Routine · role: Involved in a Marine Casualty · activity 4136950
14 May 2015Routine · role: Involved in a Marine Casualty · activity 5130877
19 March 2016Routine · role: Involved in a Marine Casualty · activity 5838617
30 April 2016Routine · role: Involved in a Marine Casualty · activity 5873995
27 June 2016Routine · role: Involved in a Marine Casualty · activity 5935856
18 July 2016Routine · role: Involved in a Marine Casualty · activity 5948656
31 October 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6077381
5 November 2017Routine · role: Involved in a Marine Casualty · activity 6307022
9 May 2021Routine · role: Involved in a Marine Casualty · activity 7193186
11 August 2022Routine · role: Involved in a Marine Casualty · activity 7531264
8 September 2022Routine · role: Involved in a Marine Casualty · activity 7556711
22 November 2023Routine · role: Involved in a Marine Casualty · activity 7865845
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.