MAURY USCG vessel records Sign in
← All vessels

PATRIOT

PATRIOT is a 1970 passenger vessel (inspected). The Coast Guard has recorded 156 inspections since 1981, most recently in April 2026, along with 456 deficiencies — 1 with no resolution recorded —, 30 operational controls and 11 casualty investigations between 2011 and 2022.

Records from 1981 to 2026. Most recent: inspection, 29 April 2026.

Built
1970
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7947
Flag
UNITED STATES
303290000
Maury page id
psix-46658

Inspections, by type

…with no type recorded37
…past their stated due date1
Years with a record 43 calendar years (1981–2026)
The 156 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.0 ft × 17.0 ft × 8.6 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE, LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTANAPAG HARBOR, SAIPAN, MP
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7947MMSI 303290000 · active · compulsorily equipped · granted 12 December 2025, expires 3 December 2035
WCR3480MMSI not assigned · expired · voluntarily equipped · granted 3 May 1995, cancelled 9 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENDEAVOR Towing Vessel · MISLE 139738 · 4 March 2022 · activity 7408400SHAMROCK Passenger (Inspected) · MISLE 46149 · 13 August 2020 · activity 7032577TALOFOFO Towing Vessel · MISLE 944367 · 8 June 2020 · activity 6980716TAGA Towing Vessel · MISLE 488566 · 30 August 2011 · activity 4136933CAJUN Passenger (Inspected) · MISLE 304503 · 16 December 1997 · activity 160450

Inspection history · 156

29 April 2026 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8358409
1 April 2026 Vessel Attendance · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8340142
6 March 2026 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8319581
18 February 2026 Annual Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8311232
28 August 2025 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8219478
14 May 2025 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8135517
4 September 2024 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7995769
5 July 2024 Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7949281
28 May 2024 Drydock Extension · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7921181
13 March 2024 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7880278
13 February 2024 Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7864706
1 March 2023 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7690201
30 December 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7615250
12 August 2022 In-Service Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7541130
24 June 2022 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7485640
17 March 2022 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7413310
6 March 2022 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7406829
4 March 2022 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7408400
28 February 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7402845
21 January 2022 COI Inspection · Deficiency Check · Re-Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7401089
6 December 2021 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7362907
16 July 2021 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7260359
16 July 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7260605
12 June 2021 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7222895
18 May 2021 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7201557
30 December 2020 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7117933
13 November 2020 Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7096572
23 September 2020 Spot Check · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7063988
13 August 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7032577
9 June 2020 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6971712
8 June 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6980716
10 February 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6905820
14 January 2020 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6888806
30 August 2019 Administrative Inspection · Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6798822
24 June 2019 Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6724698
4 June 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6702936
12 February 2019 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6624890
1 October 2018 Examination of Repairs · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6552111
9 March 2018 Internal Structural Exam · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6369870
30 January 2018 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6345911
3 January 2018 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6331765
27 October 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6298036
27 October 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6302985
21 October 2017 Deficiency Check · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6292077
18 October 2017 Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6293750
8 October 2017 Damage Survey · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6289078
22 September 2017 Damage Survey · Examination of Repairs · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6272277
21 September 2017 In-Service Inspection · Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6272278
15 September 2017 Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6271418
11 September 2017 Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6263940
10 September 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6734297
30 August 2017 Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255106
30 August 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255108
29 August 2017 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6255112
22 May 2017 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6151947
27 April 2017 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6138521
20 April 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6129465
20 April 2017 Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6131960
17 April 2017 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6125906
4 April 2017 Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6124230
21 January 2017 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6074914
8 December 2016 COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6054188
24 March 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5839434
10 February 2016 Hull Examination · Examination of Repairs · Internal Structural Exam · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5830451
6 January 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5792635
17 June 2012 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4348403
13 September 2011 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4143670
30 August 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4130538
30 August 2011 Examination of Repairs · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4136812
30 August 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4136933
30 August 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4136943
26 August 2011 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4127199
26 January 2011 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3933152
24 January 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3949651
20 December 2010 In-Service Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3913534
23 September 2010 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3855299
9 April 2009 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3448917
1 February 2008 Internal Structural Exam · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3138743
7 September 2007 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3051476
27 February 2007 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2878199
31 May 2006 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2665552
7 February 2006 COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2580379
13 August 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2479051
4 May 2005 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2348820
4 May 2005 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2348824
1 May 2005 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2346502
1 April 2005 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2324134
27 October 2004 MTSA Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2234361
8 September 2004 In-Service Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2189842
25 March 2004 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2035051
15 January 2004 Deficiency Check · Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1984896
18 December 2003 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1965990
23 January 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1726176
30 January 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1482051
15 January 2002 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1477257
14 December 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1473960
11 March 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1061363
20 February 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1058087
19 January 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1384652
4 February 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 814020
20 January 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365534
29 December 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1372857
19 November 1999 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1369421
15 November 1999 Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1372819
11 November 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 143232
1 November 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796246
19 October 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 792041
15 July 1999 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1360988
8 June 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 805933
9 May 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796496
29 January 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1124426
12 January 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1372460
18 February 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777746
22 January 1998 Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777070
18 December 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 781881
16 December 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 160450
14 June 1997 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 775618
11 February 1997 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1095243
14 January 1997 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1096410
14 January 1997 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1098322
20 May 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1083855
5 April 1996 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1078996
20 February 1996 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 884809
11 September 1995 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 881188
24 February 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 850771
24 February 1995 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377347
20 May 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 859313
10 May 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 858186
6 April 1994 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1396071
8 January 1994 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 851363
15 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 661607
7 December 1993 Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 849489
2 April 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1146235
22 May 1992 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 955028
6 April 1992 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1441956
18 September 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353325
8 August 1991 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353213
10 April 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 930296
10 April 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1241750
1 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922178
16 April 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1240080
20 March 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240655
12 March 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907916
10 April 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894708
23 March 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 991787
20 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333152
4 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311573
12 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992096
17 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299972
22 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981739
3 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972485
30 September 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277540
23 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966427
4 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272217
31 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275582
16 April 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273867

Deficiency record · 456

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 April 2026 Resolved
The owner or managing owner shall make a vessel available for drydock examinations, internal structural examinations, required by this section. Drydock due no later than 31Mar26. Haul out and make vessel available for drydock and internal structural exams. Satisfactory drydock must be completed prior to carriage of passengers. 46 CFR 176.600(a) - 701 c.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2026
Resolved 29 May 2026
Resolution: Drydock extension approved for 09 months IAW CVC-WI-029(series), due NLT 31Dec26.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2026 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port and starboard side engine gauges are not working as intended. Repair or replace as needed to the satisfaction of MI. 46 CFR 182.20-5 (b) - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 9 June 2026
Resolution: New gauge fitted and tested in presence of attending MI. All gauges verified as of 09Jun26.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 February 2026 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicator for lazarette space is not working. Replace bulb to satisfaction of MI. 46 CFR 182.530(c) - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 6 March 2026
Resolution: New bulbs installed for all floodable spaces, alarms tested at pilothouse, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 February 2026 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Modification were made to starboard aluminum fuel tank fill pipe, FRP was molded where the pipe goes through the aluminum deck. Remove the FRP to ensure watertightness. 46 CFR 177.100 - 705 c. Prior to drydock completion.
Action required: 705 - Other - as specified
Due 31 March 2026 — due date passed with no resolution recorded
Resolution: Extended deficiency due date to coincide with drydock extension approval until 31Dec26.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 February 2026 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Starboard generator is used to start air compressor for air starter of both M/E and port generator. Starboard generator uses a battery to start, battery is not working. Replace as needed to satisfaction of MI. 46 CFR 182.10-1 - 10 c.
Action required: 10 - Deficiency Rectified
Due 18 February 2026
Resolved 18 February 2026
Resolution: New battery was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 May 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel anniversary date 08DEC, Annual Inspection was due no later than 08MAR25, 3 months past its anniversary date. Conduct Annual Inspection prior to the carriage of passengers or cargo. 46 CFR 176.500(b)(1) - 701 c.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Completed satisfactory expanded annual inspection, no deficiencies identified.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 13 March 2024 Resolved
Replace damaged metal screen for port side fuel tank vent pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 13 March 2024 Resolved
Remote fuel remote shutoff pull must be marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 March 2024 Resolved
Install missing covers for electrical outlet in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 March 2024 Resolved
Remove plastic bag in forward engine room bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 March 2024 Resolved
Make proper wire connection in generator's gauges panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 March 2024 Resolved
Secure engine room deck plates starboard side of generation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2024
Resolved 15 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2023 Resolved
Multiple adult life jackets with deteriorated reflective tape. Replace with new USCG approved reflective tape.
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 13 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2023 Resolved
Secure and repair leak on starboard fuel return line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 13 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2023 Resolved
Replace non-approved hose (no markings/ratings) on starboard pneumatic solenoid valve with an approved line and proper fittings on each end in accordance with OEM specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 13 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2023 Resolved
Remove adult lifejacket marked with vessel name: CHAMORRO and replace with lifejackets marked with the vessel name: PATRIOT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 15 May 2023
Resolution: Verified adult lifejackets properly marked with vessel's name IAW with cite: PATRIOT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2023 Resolved
Mark door with number and identification of the items stowed inside. Mark stowage compartments for adult lifejackets stored in passenger cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 15 May 2023
Resolution: Doors marked indicating quantity and identification of adult and children lifejackets inside.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 March 2023 Resolved
All electrical equipment and circuits must be clearly marked and identified. Electrical panel in the engine room is missing labels identifying circuits and equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 15 May 2023
Resolution: Verified circuits and equipment are correctly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 March 2023 Resolved
Replace guard for light in overhead above generator in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 15 May 2023
Resolution: Verified new guard installed over light above generators.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 March 2023 Resolved
Replace missing ammonia inhalant in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 15 May 2023
Resolution: Verified ammonia inhalant in onboard first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 1 March 2023 Resolved
Repair and prove operation of bridge windshield wiper to the satisfaction of the attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 13 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2023 Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Proof of training for designated crew on how to properly use/calibrate ALCO Mate Prestige/alcohol breathalyzer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 13 March 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 August 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their dueite during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Complete training and drills to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Completed drills to the satisfaction of the attending USCG MI.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 12 August 2022 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Conduct fire drill to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Completed drills to the satisfaction of the attending USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2022 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the compartment. No special fuel strainers other than those recommended or furnished by the engine manufacturer will be required. Replace missing suitable marine type strainer on starboard side main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Suitable marine fuel strainer with bowl installed to the satisfaction of the attending USCG MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 August 2022 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following items listed under 46 CFR 185.506, as applicable. Conduct passenger safety orientation to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Witnessed passenger orientation provided by crew to the satisfaction of the attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 August 2022 Resolved
Operational readiness, maintenance and inspection of lifesaving equipment. Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Maintenance, inspections of survival craft and testing of EPIRB are completed in accordance with Subpart and logged or otherwise documented for review by the Coast Guard upon request.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Verified in vessel's log book.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2022 Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use in fire fighting. The hand portable fire pump may also serve as a bilge pump. Vessel to have and maintain a hand operated portable fire pump in accordance with cite.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 20 September 2022
Resolution: Portable hand pump delivered to vessel and maintained on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2022 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation…It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Replace missing exhaust lagging on starboard main engine exhaust outboard bank to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Corrected to the satisfaction of the attending USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2022 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Excessive fresh water leak from pipe with suspected wastage connected to port side main engine heat exchanger tank. Repair or replace pipe with new to as original to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Repairs completed to the satisfaction of the attending USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2022 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Excessive fresh water leak from pipe with suspected wastage connected to port side main engine heat exchanger tank. Repair or replace pipe with new to as original to the satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Repairs completed to the satisfaction of the attending USCG MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2022 Resolved
Verify each electrical panel numbered switching unit and circuit directory are correct and properly labeled in accordance with this cite.
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Labeled to the satisfaction of the attending USCG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2022 Resolved
46 CFR 111.01-1: Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. Vessel lost starboard generator due to restriction of fuel; unable to provide electrical power to vital systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2022
Resolution: Clogged fuel filters. Filters were replaced. Generator test with no discrepancy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2022 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Pending completion of satisfactory dry dock for USCG credit, vessel is prohibited from conducting commercial operations including carrying passengers and hazardous cargo for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 January 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Replace life floats with new to as original to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 24 June 2022
Resolution: Vessel has new 3 x 15 person USCG approved life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 January 2022 Resolved
Grab Lines of the 2 ring life buoys at the stern of the vessel are deteriorated from ultraviolet light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 January 2022 Resolved
Each life jacket must be marked with Type I retroreflective material. Replace retroflective material on 7 life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident (SMI) shall comply with the requirements for drug and alcohol testing; within 2 hours when the SMI occurred for alcohol, unless precluded by safety concerns related to the incident: The vessel does have test kits available on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2022
Resolution: Verified by attending MIs during inspection of ITVs at Cabras, F2 Pier.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 January 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. Bridge and engine room electrical panel must be marked to identify each equipment and amperage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 January 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Replace missing labels to properly identify emergency lightings located in the engine room and througout the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2022 Resolved
For dry dock: 1) Prove operation of fuel shut off valve for main fuel tank in forward engine room compartment, 2) repair stbd side engine room access ladder to prevent from shifting, 3) repair/reinforce top guard rails to operating station located above wheelhouse to withstand 200lbs/per inch, and 4) remark designated locations on open deck for fuel and freshwater.
Action required: 705 - Other - as specified
Resolved 28 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2022 Resolved
Replace missing guard for steering pump shaft, missing bolt for water pump and secure oil leak from port side main engine bolt in way of inboard exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 25 January 2022 Resolved
Embarkation ladder for MOB/emergencies does not secure over starboard side guard rail. Repair ladder and prove that it can be properly secured to starboard guard to allow the crew to recover a helpless person from the water to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 28 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 January 2022 Resolved
As appropriate for intend voyage, a vessel must carry adequate and up-to-date charts. The Patriot uses paper charts as its primary means of charting and the most current printed chart on board are from the 2015 notice to mariners for Guam and Saipan. Charts have not been corrected to reflect the current local notice to mariners publication (LNM Week 02/22 was on board).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2021 Resolved
Main propulsion machinery shall be in proper operating condition and fit for service intended. Vessel suffered an engine casualty to its main propulsion engine rendering the vessel unfit to get underway to Saipan for its scheduled inspection for COI-Renewal. Prior to movement and scheduling of COI, determine cause of failure and effect permanent repairs to the main propulsion engine(s) in accordance with manufacturer's procedures. Upon completion of satisfactory sea trials post repair, contact USCG MI to schedule a deficiency follow up and sea trial. Submit report of failure and description of repairs completed to USCG MI for review.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding the designed limitations. The port main engine is not capable of operating at constant marine load.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2021 Resolved
46 CFR 111-01: Electrical installations on vessels must ensure maintenantce of services necessary for safety under normal and emergency conditions. Vessel generators suffered casualty, unable to provide electrical power to the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 December 2020 Resolved
Inoperable RPM gauges for port Propulsion Engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 December 2020 Resolved
damaged / missing deck rail aft passenger deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 30 December 2020 Resolved
Missing gasket for starboard engine room escape hatch to aft deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 December 2020 Resolved
Wasted and holed port entrance to engine room from aft deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 December 2020 Resolved
Inoperable engine temperature gauge for starboard generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 December 2020 Resolved
Improper (exposed connections) wire connection for battery charger in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 30 December 2020 Resolved
Improper location for engine room exhaust ventilation duct.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 13 January 2021
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 December 2020 Resolved
Crew unable to demonstrate proper operations of the single Side Band (MF/HF) radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 23 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2020 Resolved
Old T / 46 CFR 182.25-5 (c): Each bilge suction line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. Replace missing check valve on bilge suction line in galley and prove operation to the satisfaction of the attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2020
Resolution: Inspected bilge suction line in galley with new check valve installed and witness satisfactory test of suction line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 September 2020 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessels over 65 feet are required to have 2 fixed power pumps with minimum capacity required to pump 50 gallons per minute. The two required fixed power bilge pumps shall be self-priming and shall beach be driven by different sources of power.Prove proper of operation of port side and starboard side bilge pumps to the satisfaction of the attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2020
Resolution: Witnessed satisfactory test of port/staboard bilge pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2020 Resolved
Old T / 46 CFR 182.25-5 (e): The portable hand bilge pump shall be provided with suitable hose for pumping bilges on the suction and discharge ends. Provide portable hand bilge pump with adequate length of hose for discharge side and to reach bottom of bilge in forward anchor chain locker, engine room space, aft steering and below forward crew cabin without having to access space below main deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2020
Resolved 17 November 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 July 2020 Resolved
46 CFR 176.20-1(Old T): Repairs affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall not be made without the knowledge and approval of the Officer in Charge of Marine Inspections. Vessel is restricted to operating no more than 3 miles from shore pending permanents repairs to starboard side shell using a metal plate insert that is ABS certified. Permanent repairs must be completed to the satisfaction of the attending Marine Inspector no later than vessel's next scheduled dry dock date of 28FEB2022, or upon delivery and proof of an ABS certified metal plate, or whichever is sooner.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 17 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 January 2020 Resolved
46 CFR 180.30-1: A vessel caring only one ring buoy must must have an operational working floating light. Replace missing battery in accordance with manufacturer's specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 January 2020 Resolved
46 CFR 180.25: Each life jacket and ring buoy must be marked in clearly legible block capital letters with the vessel's name. Remark vessel's name on all ring buoys and replace deteriorated reflective SOLAS I tape with USCG approved.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 January 2020 Resolved
46 CFR 182.530: A visual and audible bilge high level alarm must be provided at the operating station to indicate a high water level. High water bilge alarm for passenger cabin is audible is low but visual indicator working. Repair alarm to operating condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2020 Resolved
46 CFR 183.30-35: The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. Flames screens must be of corrosion resistant wire of at least 30 x 30 mesh.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2020 Resolved
46 CFR 183.01-15: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and vessel from electrical hazards. Remove dead-end wires in bulkhead cabinet in crew galley.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 January 2020 Resolved
Remark all fill line, vents and sounding tubes on deck.
Action required: 705 - Other - as specified
Resolved 31 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 14 January 2020 Resolved
Repair windshield wiper on wheelhouse window and prove operation.
Action required: 705 - Other - as specified
Resolved 31 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2020 Resolved
Repair anchor light and prove operation.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2020 Resolved
Repair unapproved overhead light connected to 110V outlet in crew galley.
Action required: 705 - Other - as specified
Resolved 31 March 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 January 2020 Resolved
Repair emergency light in crew galley and prove operation.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2020 Resolved
Replace missing hold back chains or corrosion resistant cables for fill lines on deck.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 January 2020 Resolved
Remove fuel shut off valves in engine room compartment for maintenance and prove operation.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2020 Resolved
Secure reach rod to valve in forward chain locker.
Action required: 705 - Other - as specified
Resolved 31 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2020 Resolved
Removed debris from bilge suction ends and make available for further test/inspection.
Action required: 705 - Other - as specified
Resolved 31 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2020 Resolved
Repair exposed electrical cables on port/starboard exterior lights forward of the wheelhouse and on top of wheelhouse in way of aft window.
Action required: 705 - Other - as specified
Resolved 31 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2020 Resolved
Repair reach rod to main fuel shut off valve to turn freely.
Action required: 705 - Other - as specified
Resolved 31 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2020 Resolved
Remove or properly cap exposed electrical wires above mains in engine room compartment.
Action required: 703 - Prior to bunkering operations
Resolved 31 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020 Resolved
Repair leaking port main engine pneumatic actuator.
Action required: 705 - Other - as specified
Resolved 31 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2020 Resolved
Replace broken wheel valves for fixed bilge suction lines in frwd engine room bilge with new.
Action required: 705 - Other - as specified
Resolved 31 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2020 Resolved
Make permanent repairs to horn. Portable horn may be used as a temporary solution until dry dock.
Action required: 705 - Other - as specified
Resolved 31 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 14 January 2020 Resolved
Replace missing thimble on rope for anchor.
Action required: 705 - Other - as specified
Resolved 31 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
46 CFR 176.20: Repair and secure leak to port main engine water pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 22 October 2019
Resolution: Got vessel underway in Outer Apra Harbor. No leaks observed from port M/E water pump.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 October 2019 Resolved
46CFR183.410: Total of 3 overhead lights in engine room compartment are inoperable, one with a broken cover secured with two copper wires to hold it in position. Prove proper operation of overhead lights and replace broken light fixture cover with new.
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 26 December 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 September 2019 Resolved
46CFR184.704: Unapproved pipe modification made to waste line for forward washroom. Discovered non-metallic hose connected to discharge line for forward washroom into the bilge. Remove non-metallic hose and cap end to as original to prevent an accidental release of raw sewage/gray water into the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 15 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019 Resolved
46CFR183.200: Air compressor in forward void continuously trips; secure air compressor until proper repairs and test are completed to the satisfaction of the attenidng USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 15 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019 Resolved
46CFR183.220: All electrical equipment and circuits must be clearly marked and identified. Found multiple single-pole circuit breakers marked as "spare" in the "on" position that could not be verified by crew and circuit breakers incorrectly labeled for the equipment/circuits in use. Remark/label breaker panels througout the vessel with the equipment/circuits connected and in use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 22 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 August 2019 Resolved
46 CFR 176.20: Repair solenoid starter to port main engine as to original and prove proper operation to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2019 Resolved
46 CFR 176.20: Replace with new or bench test to prove operation of gage on port side compressor in engine room to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 August 2019 Resolved
46 CFR 185.700: Vessel's 3 x 15 person BAs are not maintained in accordance with manufacturer's specficiations and in readily condition; BAs are exposed directly in the sun causing over 50% of the exterior protective layer to crack and deteriorate exposing inner foam, separated beckets and deteriorated netting. Must be replaced with new USCG approved and properly maintained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 December 2019
Resolution: Three new 15 x person BAs installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 August 2019 Resolved
Fuel leaking into the engine room creating a fire hazard. Replace leaking site glass tube for fuel tank on aft bulkhead in engine room with new and to as original to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2019 Resolved
Excessive exhaust leaks in engine room compartment coming from both main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 June 2019 Resolved
Replace missing sign for hearing protection at entrance to engine room.
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 2 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 25 June 2019 Resolved
Install missing guard over belt on compressor in forward void.
Action required: 705 - Other - as specified
Resolved 2 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2019 Resolved
46 CFR 182.100: Remove all oily waste from bilge and secure oil leaks in engine room. Port side transmission shifter observed with leaks and starboard side main engine with multiple oil leaks. Repairs to secure leaks must be in accordance with manufacturer’s specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2019 Resolved
46CFR182.100: Multiple exhaust leaks in engine room from port and starboard main engines. Observed exhaust leak on inboard bank on starboard main engine and on outboard exhaust bank on port main engine. Repair or replace exhausts to as original. Crew to also remove exhaust lagging to inspect/assess for further leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 12 February 2019 Resolved
46CFR182.100: Engine room deck plates and port/starboard ladders with oil creating unsafe and slippery conditions. Remove oil residue from all work surface areas. Recommend applying a non-skid or anti-slip surface coating on ladder rungs and portions of deck plates in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2019 Resolved
46CFR183.330: Electrical distribution panel in wheelhouse does not correctly identify each vital/non-vital equipment in use on the vessel. Correctly identify and remark each electrical switch on panel and prove on/off power supply to each equipment to the satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 February 2019 Resolved
46CFR179.360(a): Replace watertight gasket on deck hatch cover for forward chein locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 February 2019 Resolved
46 CFR 180.72/130/200/185.604: Weak link stowed on wheelhouse deck is not connected to a life float. Weak link must be attached to life float as per manufacturer’s instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 February 2019 Resolved
46CFR182.410: Replace main engine alarms in wheelhouse with new and prove operation to the satisfaction of the attending USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 6 May 2019
Resolution: Audible and visual alarm for low fuel and oil pressure tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 February 2019 Resolved
46CFR177.960: Replace missing guard on air compressor in forward auxiliary space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 6 May 2019
Resolution: Guard installed over moving belt on compressor.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 February 2019 Resolved
46CFR181.300: Fire pump discharge output tested below required psi. Prove proper operation of fire pump in accordance with cite.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 11 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2019 Resolved
IMO Res A.658 Annex 2(3.1); 46 CFR 180.72: Identified 39, adult Type 1 PFDs and 1, child Type 1, PFD with worn and missing reflective tape. Replace reflective tape with USCG approved SOLAS A reflective tape to as original. Vessel is also restricted to operating within Apra Outer Harbor until corrected to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 12 February 2019 Resolved
46CFR182.602: Provide means for communication between engine room and wheelhouse to the satisfaction of USCG; crew unable to prove how communications is maintained while underway when Captain is in wheelhouse and crew is in machinery compartment. Vsl is not required to have fixed means but must be able to demonstrate communications between operating station and machinery compartment in case of emergency and during routine maintenance checks while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 9 April 2019
Resolution: Company signed procedure for means of communication dtd 03MAY2019.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2019 Resolved
46 CFR 181.500/NFPA 10: Replace B1 type portable fire extinguisher in wheelhouse with new. B1 fire extinguisher discharge nozzle is unusable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2019 Resolved
46 CFR 181.115/120: Prove proper operation of all interior smoke detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 February 2019 Resolved
46CFR183.432: Prove proper operation of all interior emergency lights and mark IAW cite. Emergency overhead light in lower forward crew cabin inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 20 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 12 February 2019 Resolved
46 CFR 185.606: Replace missing latch on emergency hatch covers on deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 9 April 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 February 2019 Resolved
46 CFR 184.610(c): Prove proper operation of PA system in lower passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 February 2019 Resolved
46 CFR 184.402: Replace missing compass deviation table in wheelhouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 February 2019 Resolved
46CFR184.506: Replace missing placard for emergency broadcast placard in wheelhouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 12 February 2019 Resolved
46CFR184.404: Prove proper operation of radar required for Oceans per vessel’s Certificate of Inspection. Vessel is also restricted to operating within Outer Apra Harbor pending correction to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
09 - Working and Living Conditions › 091 - Living Conditions › Clear head
Issued 12 February 2019 Resolved
46CFR176.818: Prove proper operation of washrooms in main passenger accommodation and in forward crew accommodation space. Vessel is restricted to operating within Outer Apra Harbor and runs less than 30 minutes pending corrective action to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 6 May 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 February 2019 Resolved
46CFR182.720: Unapproved repairs to MSD line using tape. Repair MSD line to as original. Pending proper repairs to the satisfaction of USCG, washrooms are also prohibited from being used.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 11 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 February 2019 Resolved
46CFR183.200(b): Replace missing protective covers for overhead light in lower passenger cabin and in forward crew accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2019 Resolved
46CFR181.500/NFPA 10: Inspection tags attached on portable fire extinguishers must be marked with the identification number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 February 2019 Resolved
46CFR176.816: Broken and unreadable control panel in wheelhouse with switches to identifying each navigational and emergency lights. Repair or replace panel to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 9 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2019 Resolved
46CFR183.330: Electrical distribution panel in wheelhouse does not correctly identify each vital/non-vital equipment in use on the vessel. Correctly identify and remark each electrical switch on panel and prove on/off power supply to each equipment to the satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2018 Resolved
Steering Ram Failure. Replace with new approved equipment to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 2 August 2019
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 March 2018 Resolved
Crew member must be able to pick up the person in water as required by 46 CFR 185.512(a)(2). crew were unable demonstrate recovery of person in water, recovery harness was on board but davit was not set up to lift PIW to main deck. Demonstrate crew ability to pick up PIW to main deck.
Due 23 March 2018
Resolved 23 March 2018
Lifesaving › Lifefloat › Serviceable
Issued 9 March 2018 Resolved
Life saving equipment must be in serviceable conditions as required by 46 CFR 176.808(b). Found vessel's life float with damaged (torn) outer later exposing inner core. Repair life float per manufacture instruction or replace life float.
Due 23 March 2018
Resolved 23 March 2018
Documentation › Markings/Placards › Warning Signs
Issued 9 March 2018 Resolved
Escape hatch must be marked on both sides in clear legible letter (2 inches) high: " EMERGEN CY EXIT. KEEP CLEAR" as requir3ed by 46 CFR185.606. Properly stencil escape hatch in wheel house deck.
Due 23 March 2018
Resolved 23 March 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2018 Resolved
Electrical equipment must be maintained to protect crew and passenger from electrical hazard as required by 46 CFR 183.200. Install missing light bulb in forward crew berthing .
Due 23 March 2018
Resolved 23 March 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 March 2018 Resolved
Hand portable fire extinguishers must be properly maintained and in serviceable conditions as required by 46 CFR 176.810(b)(1). Found one portable CO2 with pressure gauge indicated under pressure and one missing service tag. Provide proof of maintenance and service conducted.
Due 23 March 2018
Resolved 23 March 2018
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 January 2018 Resolved
Damaged starboard generator exhaust pipe. Conduct repair with in-kind material. Operational test to be attested by the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 4 January 2018
Resolution: Completed repairs. Operational test was satisfactory.
Engineering › Steering Gear System › Valve, Control
Issued 15 November 2017 Resolved
While attending vessel at Pier F2, for deficiency follow up was informed of an air leak when control throttle is engaged in forward position. To be repaired prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 27 October 2017 Resolved
Spring pin for starboard side actuator stop to be replaced with new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2017
Resolved 28 October 2017
Resolution: New pin installed on actuator stop.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 21 October 2017 Resolved
Transmission linkage failed due to backed out threads.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 October 2017 Resolved
46 CFR 176.20-1: Make ready for inspection port and starboard main exhausts for USCG inspection.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 15 November 2017
Resolution: Inspection complete and no exhaust leaks observed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 October 2017 Resolved
46 CFR 176.20-1: Submit repair plan for exhaust leaks for USCG; repairs to be completed in accordance with USCG approved plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2017
Lifesaving › Work Vest › Readily Accessible
Issued 19 October 2017 Resolved
46 CFR 176.25-40: Replace missing work vests; must be maintained and made readily available for crew on board at all times.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 20 February 2019
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2017 Resolved
46 CFR 184.502 A vessel must comply with the applicable requirements for any radio installation requirements issued by the FCC as set forth in 47 CFR 80. Vsl equipped with an SSB. Provide proof of operators RR for all potential captains. Captains without an RR are prohibited from operating on an OCEANS route.
Action required: 705 - Other - as specified
Resolved 20 February 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 10 October 2017 Resolved
46CFR176.830: Replace exhaust lagging saturated with oil with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2017
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2017 Resolved
46 CFR 176.700: Replace leaking oil return hose on port main engine with new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 October 2017 Resolved
46CFR176.830: Remove all oily waste from bilge and water/trash from aft steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2017
Engineering › Steering Gear System › Actuator
Issued 22 September 2017 Resolved
46 CFR 176.20-1: Make repair to port actuator to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2017
Resolution: Internal seal replaced with new.
Engineering › Steering Gear System › Actuator
Issued 22 September 2017 Resolved
46 CFR 176.20-1: Replace repaired valve actuator with new to the satisfaction of the attending MI. This is the second casualty. First casualty occurred on 21SEP2017.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 8 December 2017
Resolution: New port and starboard actuators installed and tested satisfactory.
Engineering › Steering Gear System › Piping
Issued 22 September 2017 Resolved
46 CFR 176.20-1: Replace unapproved plastic compression fittings and hose that directs air to the port actuator to as original.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 15 November 2017
Resolution: Replaced with copper tubing and compression fittings.
Engineering › Steering Gear System › Solenoid Valve
Issued 22 September 2017 Resolved
46 CFR 176.20-1: Replace unnapproved repairs (splice wires with exposed connectors) to as original for pressure switch/solenoids on both port and starboard main propulsion engines.
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 15 November 2017
Resolution: Replaced with copper tubing and compression fittings.
Engineering › Steering Gear System › Actuator
Issued 21 September 2017 Resolved
Actuator for port side throttle was removed to replace wasted shaft seal. Repair plan submitted by P/E.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 September 2017 Resolved
Replace missing deck plate for port side shaft. Shaft is partially exposed forward of genenerator. Secure deck plate over exposed starboard side shaft in engine room compartment.
Due 19 September 2017
Resolved 19 September 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 September 2017 Resolved
Remove all oily waste from bilge and wipe all machinery and deck plates free of oil. No sail issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 September 2017 Resolved
Replace or repair single side band to the satisfaction of the attending MI. Vessel is prohibited from OCEANS route pending proper repair or replacement.
Action required: 705 - Other - as specified
Resolved 23 March 2018
Operations/Management › Vessel Activity › Construction/Repair
Issued 19 September 2017 Resolved
Submit to OCMI a repair proposal for securing leaks on main propulsion engines including port side transmission.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 15 November 2017
Operations/Management › Vessel Activity › Construction/Repair
Issued 19 September 2017 Resolved
Conduct repair to secure leaks on main propulsion engines in accordance with OCMI approved repair proposal.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 September 2017 Resolved
Repair sea water leaks on port main propulsion main engine on intake manifold.
Due 19 September 2017
Resolved 19 September 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 September 2017 Resolved
Repair sea water leaks on port main wet exhaust in engine room compartment.
Due 19 September 2017
Resolved 19 September 2017
Resolution: Replaced missing clamps on 1" dump line connected to wet main exhaust.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 15 September 2017 Resolved
Assess and make repairs to port side main propulsion engien due to excessive exhaust. Observed at speeds less than 10 x 100 rpm, excessive amount of exhaust even while engine is idling.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 8 December 2017
Resolution: Sea trial completed with no further issues.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 11 September 2017 Resolved
Unknown cause of port engine failure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 12 September 2017
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 September 2017 Resolved
Battery missing from main cabin detector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 12 September 2017
Engineering › Fuel Oil Service System › Filter
Issued 11 September 2017 Resolved
Active fuel oil leak in way of secondary fuel filter system / sending unit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 12 September 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 September 2017 Resolved
Several emergency lights inpoerable.
Condition: Improper/Lack of Maintenance
Due 28 September 2017
Resolved 25 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 30 August 2017 Resolved
Determine the cause of water entering the starboard main engine's cylinders, make proper repair, and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2017
Resolved 1 September 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 22 May 2017 Resolved
Starboard propulsion engine sustained high engine temperature caused engine to shut-down. Trouble shoot the cause of the casualty, conduct repairs I.A.W. engine manufacture instructions. No Sail until repairs are completed and OPS test in conducted to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 24 June 2017
Resolution: Replaced engine with in-kind engine, conducted satisfactory underway test.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 April 2017 Resolved
46 CFR 176.830: Install guard over shaft of motor pump on lube oil service tank.
Due 8 May 2017
Resolved 8 May 2017
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 25 April 2017 Resolved
46 CFR 182.100: Replace missing pressure gauge for lube oil service pump.
Due 28 April 2017
Resolved 27 April 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 April 2017 Resolved
46 CFR 182.100: Secure and repair leaking valve on lube oil service tank in engine room.
Due 28 April 2017
Resolved 27 April 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 April 2017 Resolved
46 CFR 182.100: Repair water leak on port side expansion tank for generator.
Due 28 April 2017
Resolved 27 April 2017
Engineering › Fuel Oil Service System › Tank
Issued 17 April 2017 Resolved
Lazzarette tank ran empty while vessel was underway. Engines became airbound.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2017
Resolved 17 April 2017
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 17 April 2017 Resolved
Expansion tank witnessed to be actively spraying water throughtout engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2017
Resolved 17 April 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 April 2017 Resolved
46 CFR 182.100/176.830: Remove all oily waste in bilge and properly dispose of IAW federal/state laws.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 April 2017 Resolved
46 CFR 176.830: Replace exhaust lagging for port and starboard side propulsion engines. Repair leaking water on stbd exhaust and replace missing support bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Engineering › Bilge Water Management System › Not Installed
Issued 14 April 2017 Resolved
46 CFR 176.830: Replace bilge pick up in forward compartment of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Secure oil leaks to port side propulsion engine, near governor, starter, etc.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Replace missing covers/panels for electrical boxes in auxiliary, electrical distribution panel for air compressor in engine room and A/C unit in aux space found with duct tape over openings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Stability › Watertight Integrity › Coaming
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Make watertight engine room hatch cover on deck to as original.
Due 15 May 2017
Resolved 15 September 2017
Lifesaving › Lifefloat › Markings
Issued 14 April 2017 Resolved
46 CFR 185.604: Name of vessel and capacity must be marked on vessel's life floats.
Due 17 April 2017
Resolved 15 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Remove dead end wires under operating station and replace cover for J-box.
Due 17 April 2017
Resolved 25 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Cap off dead end wires in forward cabin and replace missing covers for light fixtures.
Due 17 April 2017
Resolved 25 April 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2017 Resolved
46 CFR 176.830/182.100: Properly connect spliced wires for engine air start indicator alarm in engine room at electrical box on bulkhead adjacent to port side main engine.
Due 17 April 2017
Resolved 15 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 4 April 2017 Resolved
46 CFR 182.100/176.830: Exhaust leak in way of turbo charger on port side propulsion main engine. Remove port side exhaust lagging for inspection and repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 April 2017 Resolved
46 CFR 182.100: Remove all oily waste in bilge and properly dispose IAW federal/state laws.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 4 April 2017 Resolved
46 CFR 182.100/176.183: Replace missing exhaust lagging on port side main propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 21 January 2017 Resolved
Failure of Starboard propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2017
Resolved 16 February 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 January 2017 Resolved
46 CFR 182.100: Remove oily wsate in bilge and properly dispose IAW federal/state laws. Vessel crew to document/log remove oily waste and submit to USCG upon request.
Action required: 705 - Other - as specified
Resolved 16 February 2017
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 20 January 2017 Resolved
46 CFR 176.800: Additional crew member dedicated to removing oily waste from bilge and continuously wipe down all machinery equipment oil free in machinery space.
Action required: 705 - Other - as specified
Resolved 16 February 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Secure leaks and make repairs to both port and starboard side engines.
Action required: 705 - Other - as specified
Resolved 16 February 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Secure water leak and make repairs to port side engine wet exhaust.
Action required: 705 - Other - as specified
Resolved 15 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Secure exhaust leaks and make repairs to port side engine exhaust.
Action required: 705 - Other - as specified
Resolved 16 February 2017
Engineering › Steering Gear System › Solenoid Valve
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Repair and secure hydraulic leak from steering selector in engine room compartment.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Submit scope/description of engine repairs and steering selector.
Action required: 705 - Other - as specified
Resolved 17 April 2017
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 20 January 2017 Resolved
46 CFR 176.700/182.100: Submit copy of regular maintenance plan and checklist for mains.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 20 February 2019
Resolution: Extended due date to 01NOV017.
Electrical › Electric Generation Source (service) › Generator
Issued 27 December 2016 Resolved
46 CFR 176.700: Repair starboard side generator expansion tank to as original. Unapproved repairs made-missing fixed connection for recirculating fresh water hose.
Due 30 December 2016
Resolved 14 January 2017
Electrical › Electric Generation Source (service) › Generator
Issued 27 December 2016 Resolved
46 CFR 182.710: Replace non-metallic piping material for vital system (water supply line for generator) w/original.
Due 30 December 2016
Resolved 14 January 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 December 2016 Resolved
46 CFR 177.600: Prove proper operation of powered ventilation in engine room compartment.
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 23 March 2018
Resolution: Extended due date.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 December 2016 Resolved
46 CFR 182.100/176.700: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Starboard engine leaking oil in multiple areas.
Due 20 December 2016
Resolved 27 December 2016
Engineering › Steering Gear System › Piping
Issued 19 December 2016 Resolved
46 CFR 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Repair and secure leak from steering wheel shaft at operator's station.
Due 30 December 2016
Resolved 27 December 2016
Engineering › Steering Gear System › Solenoid Valve
Issued 19 December 2016 Resolved
46 CFR 182.100/176.700: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Repair and secure hydraulic leak from steering selector in engine room compartment.
Due 27 December 2016
Resolved 27 December 2016
Lifesaving › Lifefloat › Serviceable
Issued 8 December 2016 Resolved
46CFR176.808(b): Make proper repairs to life floats. Life floats found with deteriorated beckets and grab lines deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2016
Resolution: Temporary repairs acceptable; lines replaced with new and beckets secured with strap pending new shipment of life floats (total of three 15 man life floats).
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 8 December 2016 Resolved
46 CFR 182.430(a): Replace exhaust lagging for mains and generators found missing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Replaced to the satisfaction of MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 December 2016 Resolved
46 CFR 183.420: Side lights inoperable. Prove proper operation of running lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Corrected to the satisfaction of MI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 December 2016 Resolved
46 CFR 183.432(b): Prove proper operation of emergency lights in all spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Corrected to the satisfaction of MI.
Engineering › Fuel Oil Service System › Filter
Issued 8 December 2016 Resolved
46 CFR 182.455(b)(6): Install missing flame bowl with an approved type for port side fuel filter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Corrected to the satisfaction of MI.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 December 2016 Resolved
46 CFR 176.818: Crew and passenger messrooms used to store waste materials and trash. Remove and dispose of properly IAW state laws.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 December 2016 Resolved
46 CFR 177.500(i)/46 CFR 185.606: Missing marking for Emergency Exits on upper passenger cabin and galley.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Corrected to the satisfaction of MI.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 8 December 2016 Resolved
46 CFR 181.400(e): Replace missing smoke detector in crew cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2016
Resolution: Smoke detectors reinstalled in accommodation space for crew sleeping quarters.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 December 2016 Resolved
46 CFR 182.100: Prove power has been secured to inoperable A/C unit at source and switch board.
Due 11 December 2016
Resolved 11 December 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2016 Resolved
46 CFR 176.802: Replace missing bulkhead panel in lower cabin with exposed electrical and piping.
Due 11 December 2016
Resolved 11 December 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 December 2016 Resolved
46 CFR 185.520: Log drills/safety equipment in vessel log book as required for MOB, fire, fire extinguishers, life jacket and life floats.
Due 11 December 2016
Resolved 11 December 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2016 Resolved
46 CFR 111.60-17: Remove dead end wires in galley and crew cabin; use approved connectors for spliced wires.
Due 11 December 2016
Resolved 11 December 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 December 2016 Resolved
46 CFR 176.830: Remove unsecured and decommissioned miscellaneous ship service related equipment stored in forward auxiliary space.
Due 11 December 2016
Resolved 11 December 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 8 December 2016 Resolved
46 CFR 111.75-20: Replace missing light guard for overhead light in aft steering space.
Due 11 December 2016
Resolved 11 December 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 December 2016 Resolved
46 CFR 183.430: Missing portable flashlights near engine room compartment and at operating station.
Due 11 December 2016
Resolved 15 April 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2016 Resolved
46 CFR 111.01-1: Properly cap off dead end wires for water pump in forward auxiliary space and prove power has been secured.
Due 11 December 2016
Resolved 11 December 2016
Electrical › Electric Generation Source (service) › Generator
Issued 8 December 2016 Resolved
46 CFR 182.100: Repair air regulator for port side engine. Regulator is secured with a plastic strap tie.
Due 16 December 2016
Resolved 19 December 2016
Electrical › Electric Generation Source (service) › Generator
Issued 8 December 2016 Resolved
46 CFR 182.100: Repair starboard side generator starter and secure electrical wiring.
Due 16 December 2016
Resolved 19 December 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 December 2016 Resolved
46 CFR 177.960: Install machine guards over exposed moving parts on port and starboard side generators.
Due 16 December 2016
Resolved 19 December 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 December 2016 Resolved
46 CFR 176.800: Install proper latch for electrical panel in engine room compartment.
Due 16 December 2016
Resolved 15 April 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 December 2016 Resolved
46 CFR 185.520(a)/(f) and 46 CFR 185.702: Inspect and log life sling for readiness; maintain in IAW manufacturer's recommendations. Crew to demonstrate proper use and familiarization at next drill facilitated by the master.
Action required: 705 - Other - as specified
Resolved 23 March 2018
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 December 2016 Resolved
46 CFR 185.516(a): Post donning instructions for various types of life jackets.
Due 30 December 2016
Resolved 19 December 2016
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 8 December 2016 Resolved
46 CFR 182.720(e): Replace kinked fuel hoses connected to fuel tank in steering space with USCG approved.
Due 30 December 2016
Resolved 19 December 2016
Electrical › Electric Generation Source (service) › Generator
Issued 8 December 2016 Resolved
46 CFR 182.100: Replace broken lens cover for port and starboard side air reciever gage at operating station.
Due 8 January 2017
Resolved 15 April 2017
Electrical › Electric Generation Source (service) › Generator
Issued 8 December 2016 Resolved
46 CFR 176.700/182.100: Starboard side generator's expansion tank removed from service for repairs to secure leaks.
Action required: 705 - Other - as specified
Resolved 13 April 2017
Resolution: Load test of stbd generator conducted.
Lifesaving › Lifefloat › Approval
Issued 6 January 2016 Resolved
Requirements for Out of Water Survival Craft and replacement of Life Floats and Rigid Buoyant Apparatus. See Special Note for guidance and timelines.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Engineering › Reduction Gearing/Clutches › Shaft
Issued 30 August 2011 Resolved
Key damaged for shaft keyway on stbd engine reduction gear. Demonstrate proper operation of stbd engine and associated shafting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2011
Resolution: Keyway repaired and tested satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 30 August 2011 Resolved
Approximately 2 inch puncture located in hull, port side forward, adjacent to the collision bulkhead. The puncture is approximately 6 feet above the water line. Crop and renew holed hull plating, port side forward.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2011
Resolution: Hull repaired and tested satisfactorily.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 August 2011 Resolved
Repair pin hole leak in elbow on starboard MDE cooling system.
Due 16 September 2011
Resolved 13 September 2011
Resolution: Leak repaired.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 February 2011 Resolved
Vsl restricted to short runs to MSC ships within the harbor until completion of proper repairs on engine exhaust leak located in steering gear space. Master required to test and log carbon monoxide reading after each run and ventilate the space to prevent gas build-up.
Due 28 February 2011
Resolved 26 August 2011
Resolution: Both mufflers in the lazarette were replaced. Atmosphere tested 0 CO.
Accommodation/Occupational Safety › Ventilation › General
Issued 10 February 2011 Resolved
Correct outstanding def: Lazarette atmosphere at unsafe levels. CO levels reading 5ppm to 10ppm at scuttle entry.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2011
Resolved 26 August 2011
Resolution: Both mufflers in the lazarette were replaced. Atmosphere tested 0 PPM of CO.
Stability › Watertight Integrity › General
Issued 10 February 2011 Resolved
Forepeak scuttle not watertight.
Due 10 February 2011
Resolved 10 February 2011
Resolution: Hatch cover closing device adjusted, tested with water hose.
Engineering › Bilge Water Management System › Valve
Issued 10 February 2011 Resolved
Repair bilge cutoff valve to collision bulkhead in forpeak.
Due 10 February 2011
Resolved 10 February 2011
Stability › Watertight Integrity › General
Issued 10 February 2011 Resolved
Lazarette scuttle not watertight.
Due 24 February 2011
Resolved 26 August 2011
Resolution: Scuttle made watertght.
Communications › Radio Communications › EPIRB
Issued 10 February 2011 Resolved
Hydrostatic release expiration date not marked.
Due 24 February 2011
Resolved 15 February 2011
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 February 2011 Resolved
Install additional warning sign in below decks crew space "keep sewage overboard closed within 3NM of shore."
Due 24 February 2011
Resolved 15 February 2011
Engineering › Bilge Water Management System › Not Operational
Issued 10 February 2011 Resolved
Prove proper function of bilge system. Non-self priming and stops suction. Restore to 50 gpm contant function. Demonstrate for all watertight spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2011
Resolved 15 February 2011
Lifesaving › Lifebuoys › Approval
Issued 10 February 2011 Resolved
Replace existing non-CG approved ring buoy with CG approved type.
Due 24 February 2011
Resolved 15 February 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (air motor)
Issued 24 January 2011 Resolved
Prove proper operation of PME transmission (reverse).
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2011
Resolved 10 February 2011
Accommodation/Occupational Safety › Ventilation › General
Issued 20 December 2010 Resolved
Submit proposal to address outstanding def regarding laz ventilation and possible exhaust leak.
Due 21 December 2010
Resolved 21 December 2010
Personnel › Manning/Qualifications › Citizenship Requirements
Issued 20 December 2010 Resolved
Required deckhand (1) per COI was not a U.S. Citizen.
Action required: 705 - Other - as specified
Resolved 24 January 2011
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 April 2009 Resolved
Start conducting and logging monthly EPIRB testing.
Due 23 April 2009
Resolved 23 April 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 April 2009 Resolved
Properly blank all open bays in AC electrical panels in wheelhouse and stbd entrance to E/R
Due 23 April 2009
Resolved 23 April 2009
Engineering › Bilge Water Management System › Valve
Issued 9 April 2009 Resolved
Label fwd/forepeak remote bilge valve handle.
Due 23 April 2009
Resolved 23 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 April 2009 Resolved
Provide proper bracket for portable fire extinguisher in fwd berthing.
Due 23 April 2009
Resolved 23 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2009 Resolved
Install glass globe on light fixture in fwd head.
Due 23 April 2009
Resolved 23 April 2009
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 April 2009 Resolved
Install smoke detectors in all overnight accomodations.
Due 23 April 2009
Resolved 23 April 2009
Construction/Loadline › Structures › Scuttle
Issued 9 April 2009 Resolved
Repair/adjust lower dog on fwd house door.
Due 23 April 2009
Resolved 23 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2009 Resolved
Install cover on light fixture, lower aft bunkroom.
Due 23 April 2009
Resolved 23 April 2009
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 9 April 2009 Resolved
Install lagging on stbd M/E turbo.
Due 23 April 2009
Resolved 23 April 2009
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 April 2009 Resolved
Properly install stbd M/E exhaust cooling water hose (kinked).
Due 23 April 2009
Resolved 23 April 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 April 2009 Resolved
Clean oil from aft E/R bilge.
Due 23 April 2009
Resolved 23 April 2009
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 April 2009 Resolved
Secure fuel lines fwd of port M/E.
Due 23 April 2009
Resolved 23 April 2009
Electrical › Electrical Distribution System (service) › Cable
Issued 9 April 2009 Resolved
Repair if needed and properly support port M/E electrical sending wires (melted cable insulation sleeve)
Due 23 April 2009
Resolved 23 April 2009
Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2009 Resolved
Clean oil from both AC generator(s) windings.
Due 23 April 2009
Resolved 23 April 2009
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 9 April 2009 Resolved
Repair oil leak on port M/E turbo lubrication line.
Due 23 April 2009
Resolved 23 April 2009
Fire Fighting › Fire Pumps › Pressure
Issued 9 April 2009 Resolved
Fire pump recently replaced w/out USCG notification. Provide new pump specs to meet 46 CFR 181.10.
Due 23 April 2009
Resolved 27 August 2010
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 9 April 2009 Resolved
Repair aft air reciever pressure guage.
Due 23 April 2009
Resolved 23 April 2009
Engineering › Bilge Water Management System › Pump
Issued 9 April 2009 Resolved
Provide portable hand bilge pump w/adequate hose.
Due 23 April 2009
Resolved 23 April 2009
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 9 April 2009 Resolved
Repair/install permanent battery charger. Portable charger currently installed, no other means to charge DC system are operational.
Due 23 April 2009
Resolved 23 April 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 April 2009 Resolved
Verify annual user fee's have been paid/current. MISLE show's past due. Note: There is no MSILE system/subsystem for this def...
Due 23 April 2009
Resolved 23 April 2009
Resolution: Per FINCEN, userfees due 01MAY09.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 April 2008 Resolved
Replace buoyant line on two (2) lifebuoys.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 17 April 2008
Resolution: New black floating line installed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 April 2008 Resolved
Replace eight (8) expired personal marker lights on adult lifejackets.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 28 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 April 2008 Resolved
Install missing personal marker lights on three (3) adult lifejackets.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 28 May 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 April 2008 Resolved
Place required amount of aspirin inside first aid kit.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 17 April 2008
Resolution: All items in first aid kit current.
Construction/Loadline › Hull › Hull Plating
Issued 13 February 2008 Resolved
Crop and renew a four (4) foot by five (5) foot wasted section of the starboard side shell in the steering room from the starboard aft corner to approximately five feet forward and from the chine to approximately four feet above.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 18 March 2008
Resolution: completed vacuum box test of insert, test satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 13 February 2008 Resolved
Crop and renew a three (3) foot by Four (4) foot section of bottom plating in steering gear room, from the transom to approximately four (4) feet forward and approximately eighteen (18) inches to port and starboard from the center line.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 21 March 2008
Resolution: Plating renewed and a satisfactory vacuum box test conducted.
Engineering › Steering Gear System › Piping
Issued 13 February 2008 Resolved
Make permanent repairs to hydraulic vent line.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Permanent repairs made satisfactory.
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 February 2008 Resolved
Remove all through hull fittings for inspection / testing.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: All through hull fittings were replaced with new valves all valves were leak tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 13 February 2008 Resolved
Repair / replace two (2) broken channel cooler valves, remove remaining valves for test / inspection.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Valves were repalced with new valves and pressure tested satisfactory.
Engineering › Lubricating Oil Service System › Hose
Issued 13 February 2008 Resolved
Replace all hoses longer than sixty (60) inches with piping / tubing and hoses shorter than sixty (60) inches.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: All hoses longer than sixty (60) inches were replaced with proper tubing or piping and hoses were shortened as necessary.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 13 February 2008 Resolved
Install pipe brackets on main engine jacket water cooling piping.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Pipe brackets were installed as needed.
Engineering › Fuel Oil Service System › Piping
Issued 13 February 2008 Resolved
Install brackets for main engine fuel oil piping.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Piping brackets were installed as needed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2008 Resolved
Install brackets for wiring system.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Proper wiring brackets were installed as needed.
Fire Fighting › Ventilation Systems › Fans
Issued 13 February 2008 Resolved
Clean engine room exhaust blower and ducting.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: A new exhaust blower was installed and tested satisfactory.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 February 2008 Resolved
Remove rope and install proper brackets for air conditioning ducting.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: Proper ducting brackets were installed as needed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 February 2008 Resolved
Remove unused PCV piping penetrating into forward peak tank and properly plug collision bulkhead.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 3 April 2008
Resolution: PVC piping was removed and penetration plugged.
Construction/Loadline › Hull › Bottom Plating
Issued 13 February 2008 Resolved
Crop and renew bottom plating in passenger area port side approximately three (3) feet by two (2) feet.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 21 March 2008
Resolution: Plating renewed and a satisfactory vacuum box test conducted.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 September 2007 Resolved
Repair leaking starboard shaft bearing.
Condition: Improper Installation
Due 21 September 2007
Resolved 27 September 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 September 2007 Resolved
Remove oil from engine room and lazarette bilge.
Condition: Improper/Lack of Maintenance
Due 21 September 2007
Resolved 11 September 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 7 September 2007 Resolved
Remove excessive oil from deck plates and ladder.
Condition: Improper/Lack of Maintenance
Due 21 September 2007
Resolved 11 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2007 Resolved
Replace guards on lighting in lazarette.
Condition: Improper/Lack of Maintenance
Due 21 September 2007
Resolved 11 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2007 Resolved
Install covers on fluorescent lighting in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 7 March 2007
Construction/Loadline › Structures › Manhole
Issued 27 February 2007 Resolved
Replace seal on forward watertight hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 7 March 2007
Engineering › Compressed Air System (start air) › Compressor
Issued 7 February 2006 Resolved
Secure bracket on Port MDE air start
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 February 2006 Resolved
Install railing on port aft railing.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 February 2006 Resolved
Replace latch on bridge electrical distribution panel.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 February 2006 Resolved
Replace fuel valve handle on Port MDE Raycor filter.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Engineering › Lubricating Oil Service System › Hose
Issued 7 February 2006 Resolved
Replace lube oil hoses in lazarette.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2006 Resolved
Make repair proposal for starboard gusset where it penetrates the deck.
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 13 March 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 February 2006 Resolved
Install a condensation line on forward a/c compressor.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 February 2006 Resolved
Replace/repair fuel shut off valves.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 February 2006 Resolved
Provide adequate measures to ensure overboard discharge valve for type III MSD is secured while vessel is within three miles from shore.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Documentation › Logs/Records › Logbook (official)
Issued 7 February 2006 Resolved
Provide updated log book with drills and epirb test.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2006 Resolved
Provide complete first aid kit.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Lifesaving › Lifefloat › Pendant
Issued 7 February 2006 Resolved
Install 18 ft lanyards on float lights on life floats.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Engineering › Generator (propulsion-electric) › Cable
Issued 7 February 2006 Resolved
Tighten battery cables.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 24 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2005 Resolved
Install wire nuts on electrical connections in engine room.
Due 15 April 2005
Resolved 4 May 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 April 2005 Resolved
Provide valid copy of COD.
Due 15 April 2005
Resolved 4 May 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 April 2005 Resolved
Replace retro tape as needed.
Due 15 April 2005
Resolved 4 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 1 April 2005 Resolved
Install fuel hoses that meet SAE J-1942 standards.
Due 15 April 2005
Resolved 1 April 2005
Engineering › Fuel Oil Service System › Filter
Issued 1 April 2005 Resolved
Replace/repair fuel filter on SSDG.
Due 15 April 2005
Resolved 4 May 2005
Lifesaving › Buoyant Apparatus
Issued 15 January 2004 Resolved
Replace life float, port side. LEGACY COMPONENT DESC: life float
Due 29 January 2004
Resolved 29 January 2004
Lifesaving › Lifebuoys
Issued 15 January 2004 Resolved
Replace life ring, fwd port side. Lanyard must be detachable from life ring.
Due 29 January 2004
Resolved 29 January 2004
Fire Fighting › Fire Pumps
Issued 15 January 2004 Resolved
Repair/replace discharge pressure gauge for fire pump.
Due 29 January 2004
Resolved 29 January 2004
Electrical › Electrical Distribution System (service)
Issued 15 January 2004 Resolved
Repair electrical distribution panel door located in engine room. Provide a directory for all breakers in panel.
Due 29 January 2004
Resolved 29 January 2004
Stability
Issued 15 January 2004 Resolved
Permanently label bilge manifold, engine room.
Due 29 January 2004
Resolved 29 January 2004
Accommodation/Occupational Safety
Issued 15 January 2004 Resolved
Install locking device for sewage overboard discharge valve.
Due 29 January 2004
Resolved 29 January 2004
Accommodation/Occupational Safety
Issued 15 January 2004 Resolved
Post a "Do not discharge within 3 miles of land" in vicinity of MSD overboard discharge valve.
Due 29 January 2004
Resolved 29 January 2004
Navigation
Issued 15 January 2004 Resolved
Replace glass, port, fwd accomodation space.
Due 29 January 2004
Resolved 29 January 2004
Deck/Cargo
Issued 15 January 2004 Resolved
Install additional lifeline courses to prevent passengers from going fwd, port and starboard sides.
Due 29 January 2004
Resolved 29 January 2004
Engineering
Issued 15 January 2004 Resolved
Plug crankcase discharge & MDE fuel priming line.
Due 29 January 2004
Resolved 29 January 2004
Operations/Management
Issued 15 January 2004 Resolved
Provide a "hot line" for DAPI program and provide a 60 minute supervisory training.
Due 29 January 2004
Resolved 29 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 30 January 2003 Resolved
Provide guide for port generator flywheel. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 15 February 2003
Resolved 14 February 2003
Engineering › Fuel Oil Service System
Issued 30 January 2003 Resolved
Install chafing gear on starboard main engine fuel hoses. LEGACY COMPONENT DESC: Hose
Due 15 February 2003
Resolved 14 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 30 January 2003 Resolved
Repair port engine room blower motor cover and clean oily substance in way of blower motor.
Due 15 February 2003
Resolved 14 February 2003
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 January 2003 Resolved
Program SSB radio with emergency frequency.
Due 30 January 2003
Resolved 30 January 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 January 2003 Resolved
Replace lifebuoy line with buoyant line.
Due 30 January 2003
Resolved 30 January 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 January 2003 Resolved
Repair / replace lifebuoy light.
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 January 2003 Resolved
Provide inventory for first aid kit.
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 January 2003 Resolved
Make repairs to port side railing (connection to deck).
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 January 2003 Resolved
Repair engine room port ladder.
Due 30 January 2003
Resolved 30 January 2003
Engineering › Fuel Oil Service System › Hose
Issued 23 January 2003 Resolved
Install chafing gear on fuel hoses throughout the engine room.
Due 30 January 2003
Resolved 30 January 2003
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 23 January 2003 Resolved
Provide non conductive matting in front of switchboard.
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 January 2003 Resolved
Remove oil from engine room bilge.
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 January 2003 Resolved
Remove oil from engine room equipment and piping.
Due 30 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 January 2003 Resolved
Remove open oil containers from engine room.
Due 30 January 2003
Resolved 30 January 2003
Fire Fighting › Fire Pumps
Issued 23 January 2003 Resolved
Repair and lable fire pump motor controler.
Due 30 January 2003
Resolved 30 January 2003
Engineering › Fuel Oil Service System › Valve
Issued 23 January 2003 Resolved
Repair port side emergency fuel shut off valve.
Due 30 January 2003
Resolved 30 January 2003
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 January 2003 Resolved
Replace EPIRB hydrostatic release.
Due 30 January 2003
Resolved 30 January 2003
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 January 2003 Resolved
Order replacement antenna for EPIRB.
Due 30 January 2003
Resolved 30 January 2003
Lifesaving › Buoyant Apparatus
Issued 15 January 2002 Resolved
Vessel name missing from new paddles for life floats. LEGACY COMPONENT DESC: paddles
Due 29 January 2002
Resolved 30 January 2002
Resolution: Paddles marked.
Lifesaving › Buoyant Apparatus
Issued 15 January 2002 Resolved
Restencil vessel name on vessel ring buoys. LEGACY COMPONENT DESC: ring buoy
Due 29 January 2002
Resolved 30 January 2002
Resolution: Ring Buoys marked.
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 January 2002 Resolved
Replace worn retroreflective material on five lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Due 29 January 2002
Resolved 30 January 2002
Resolution: Retroreflective material replaced.
Electrical › Lighting (service)
Issued 15 January 2002 Resolved
Replace missing bulb in lazerette. LEGACY COMPONENT DESC: Lighting Fixture
Due 29 January 2002
Resolved 30 January 2002
Resolution: Bulb and cover replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 15 January 2002 Resolved
Strengthen deck plate support member located in forward compartment, lower level.
Due 29 January 2002
Resolved 30 January 2002
Resolution: Deck repaired.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 December 2001 Resolved
Missing blanks in missing breaker spaces.
Due 3 January 2002
Resolved 3 January 2002
Resolution: installed blanks.
Engineering › Steering Gear System › Rudder Bearing
Issued 27 December 2001 Resolved
Rudder Bearing - Worn
Action required: 705 - Other - as specified
Resolved 3 January 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 December 2001 Resolved
Deck over ford cabin bilge broken
Action required: 705 - Other - as specified
Resolved 27 December 2001
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 December 2001 Resolved
Cracks in bulkhead in area of generator exhaust pipes at lazerette/engine room bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 December 2001
Engineering
Issued 27 December 2001 Resolved
Replace missing bolts in diesel exhaust pipe hangers in lazzerette.
Action required: 705 - Other - as specified
Resolved 27 December 2001
Construction/Loadline
Issued 20 February 2001 Resolved
Renew and post fire and bilge pump operating instructions.
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Electrical
Issued 20 February 2001 Resolved
Repair port side generator temperature sensor and/or gauge.
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Fire Fighting
Issued 20 February 2001 Resolved
Install a fire pump capable of delivering at least 60 psi at the pump outlet.
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Engineering
Issued 20 February 2001 Resolved
Stencil fire pump and bilge pump controls, as well as engine room ventilation fan and fuel shut-offs.
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Engineering
Issued 19 January 2001 Resolved
Repair exhaust leaks in the engine room and steering gear space.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001 Resolved
Restock first aid kit in accordance with 46CFR160.041.1.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Engineering
Issued 19 January 2001 Resolved
Replace fire screen mesh for all fuel tank vents.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Documentation
Issued 19 January 2001 Resolved
Complete an annual audit of company's random drug testing program.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Accommodation/Occupational Safety
Issued 19 January 2001 Resolved
Install a public announcement system in the passenger spaces.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Unknown
Issued 19 January 2001 Resolved
Conduct man over board and fire drills with all crews.
Condition: Unknown
Due 19 February 2001
Resolved 29 January 2001
Navigation
Issued 19 January 2001 Resolved
Update all navigational charts in accordance with the Notice to Mariners.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Documentation
Issued 19 January 2001 Resolved
One member of each crew must have a valid FCC VHF operator's permit.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 19 January 2001 Resolved
Repair or replace the starboard main engine jacket water temperature sensor.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001 Resolved
Create and implement a preventative maintenance program.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Fire Fighting
Issued 19 January 2001 Resolved
Provide vent closures for openings into the engine space.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Accommodation/Occupational Safety
Issued 19 January 2001 Resolved
Repair aft exterior public announcment speaker.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 19 January 2001 Resolved
Repair broken wiring for engine room ventilation fan.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Engineering
Issued 20 January 2000 Resolved
Repair exhaust leak in the steering gear space.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Properly wire and close junction box starboard main engine.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Mark all circuits in panel A at entrance to engine room.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 20 January 2000 Resolved
Install a retaining device for forward hatch cover.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Remove dead end wiring, aft pilothouse and inboard port engine.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Engineering
Issued 20 January 2000 Resolved
Prove proper operation of low lube oil pressure alarm.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 20 January 2000 Resolved
Update charts with local notice to mariners regularly.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 20 January 2000 Resolved
Obtain applicable sections of the light list.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Accommodation/Occupational Safety
Issued 20 January 2000 Resolved
Secure forward starboard seat in lower passenger space.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Repair or remove overhead light starboard side engine room.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Repair all gauges for port and starboard generator sets.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 20 January 2000 Resolved
Make proper electrical wire connections for navigation lights, start air solenoid, and at junction box inboard starboard main engine.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Accommodation/Occupational Safety
Issued 20 January 2000 Resolved
Ensure proper ventilation for steering gear space.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 29 December 1999 Resolved
Make repairs to pitting in bottom plate and CVK in accordance with approvedrepair proposal.
Condition: Unknown
Due 2 January 2000
Resolved 2 January 2000
Construction/Loadline
Issued 29 December 1999 Resolved
Submit written repair proposal for pitting for Coast Guard approval.
Condition: Unknown
Due 2 January 2000
Resolved 2 January 2000
Construction/Loadline
Issued 15 November 1999 Resolved
Repairs to be made to the vessel's propellors and rudders as well as make an external examination of the hull to the satisfaction of the attending marine inspector prior to passenger or cargo service.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Engineering
Issued 1 November 1999 Resolved
Provide gauges at vessel's aft operating station indicating engine RPM, J/Wtemp, and lube oil pressure for propulsion engines. In lieu of installing gauges, establish company policy directing vessel Master to operate vessel at main operating station except during actual cargo/personnel transfer ops
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 19 October 1999 Resolved
Splice painter to two of vessel's (forward) lifefloats.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Lifesaving
Issued 19 October 1999 Resolved
All waterlights for lifefloats to be connected with 18 foot lanyard.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Electrical
Issued 19 October 1999 Resolved
Label on and off for battery disconnect switch.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Lifesaving
Issued 19 October 1999 Resolved
Prove proper operation of all waterlights.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Lifesaving
Issued 19 October 1999 Resolved
Replace grablines and pendants on lifefloats.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Construction/Loadline
Issued 9 May 1999 Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Lifesaving
Issued 12 January 1999 Resolved
Remove all open lights and extension cords from engine space.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 12 January 1999 Resolved
Provide vessel crew to conduct both fire and man overboard drills in the presence of a CG inspector.
Condition: Unknown
Due 12 January 1999
Resolved 15 January 2002
Resolution: Cleared prior to MISLE migration.
Lifesaving
Issued 12 January 1999 Resolved
Obtain two (2) extra adult life jackets to bring vessel total up to 58. Until such time the extra life jackets are on board the vessel is limited to no more than 56 total persons on board.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Documentation
Issued 12 January 1999 Resolved
All vessel operators to have FCC Radio Operators Permit.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 12 January 1999 Resolved
Replace broken antenna on EPIRB. Until such time antenna is replaced, vessel is limited to not more than three (3) miles from shore.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 12 January 1999 Resolved
Obtain one more source of portable lighting.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 12 January 1999 Resolved
Replace expired hydrostatic release for EPIRB.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999 Resolved
Reattach missing handwheel on starboard main engine cooling water intake valve.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 12 January 1999 Resolved
Replace missing 30 x 30 mesh flame screen on oil tank vent, main deck stbd side, aft.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 12 January 1999 Resolved
Replace missing bolt on governor to engine mount, #2 SSDG.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Unknown
Issued 22 January 1998 Resolved
Document/log the required monthly EPIRB tests in accordance with 46 CFR 185.728.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Fire Fighting
Issued 22 January 1998 Resolved
Conduct sufficient fire drills to ensure that each crew member is familiar with his or her duties in case of fire onboard the vessel and shall be documented/logged in accordance with 46 CFR 185.524.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Lifesaving
Issued 22 January 1998 Resolved
Conduct sufficient man overboard drills to ensure that all crew members arefamiliar with their duties during emergencies that necessitate the recoveryof persons who have fallen overboard along with a record of these drills inaccordance with 46 CFR 185.520.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Unknown
Issued 22 January 1998 Resolved
Install sufficient pipe hangers on the aft fuel oil tank vent to adequatelysupport the piping.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Unknown
Issued 22 January 1998 Resolved
Remove and properly dispose of the excessive oil in the Engine room bilge to limit the risk of fire hazards in the space.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Unknown
Issued 22 January 1998 Resolved
Hydrostatically test the aft starting air receiver in the presence of a Coast Guard Inspector in accordance with 46 CFR 61.10-5.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Construction/Loadline
Issued 18 December 1997 Resolved
Crop and renew damaged side plating, associated framing, longitudinals, andbulkhead, in way of starboard side, midships. Temporay repair with two-partmetal epoxy authorized until such time repairs can be accomplished. Vessel may carry passengers/cargo only after obtaining permission from Coast Guard
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 14 January 1997 Resolved
Post life jacket donning instructions placard.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Accommodation/Occupational Safety
Issued 14 January 1997 Resolved
Install proper bulbs in bunk light fixtures located above "old" bunks, or remove fixtures.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Accommodation/Occupational Safety
Issued 14 January 1997 Resolved
Secure water heater against rolls and seas.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 14 January 1997 Resolved
Install "continuous bonding strap" on aft fuel tank fill line.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
Install pipe plug in pipe passing through bulkhead between engine room and after steering space.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Electrical
Issued 14 January 1997 Resolved
Install "blanks" in openings of breaker panel "A" located engine room fwd.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 14 January 1997 Resolved
Install guard over opening of engine room exhaust blower.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
Post diagram and operating procedures for bilge drainage system and for thebilge/firefighting cross connect system.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
Remove excess oil from bilges in engine room.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 14 January 1997 Resolved
Install missing valve handwheel on stbd engine raw water cooling line to strainer.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Fire Fighting
Issued 14 January 1997 Resolved
Repair firefighting nozzle on port firefighting hose station, ensure nozzleshuts off when turned to the shut/off position.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Deck/Cargo
Issued 14 January 1997 Resolved
Replace chain on anchor.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Electrical
Issued 14 January 1997 Resolved
Identify missing component on fire pump motor controller, replace/install same.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 14 January 1997 Resolved
Replace torn insulation on both port and stbd engine exhaust lines.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Fire Fighting
Issued 14 January 1997 Resolved
B-II CO2 fire extinguisher located main cabin aft needs hydrostatic testing
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Lifesaving
Issued 14 January 1997 Resolved
Mark "DISTRESS SIGNALS" on smoke/flare storage box.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Documentation
Issued 20 February 1996 Resolved
Shoe proof of compliance with FCC required Safety Radiotelephone Certificate/Inspection.
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Navigation
Issued 20 February 1996 Resolved
Replace improper nav light bulbs in P & S running lights, or replace running light fixtures.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Electrical
Issued 20 February 1996 Resolved
Install adequate emergency lighting below deck, lower passenger area.
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Lifesaving
Issued 20 February 1996 Resolved
Life float waterlight inoperative.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Lifesaving
Issued 20 February 1996 Resolved
Obtain four (4) more adult pfd's to bring total in line with total persons on COI.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Engineering
Issued 20 February 1996 Resolved
Replace missing bolts for fuel oil tank cover, lower passenger space.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Electrical
Issued 20 February 1996 Resolved
Remove dead end electrical cable, located forward machinery space.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Construction/Loadline
Issued 20 February 1996 Resolved
Lable bilge manifold valves.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Construction/Loadline
Issued 20 February 1996 Resolved
Post bilge piping digram in area of bilge manifold.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Fire Fighting
Issued 20 February 1996 Resolved
Free up combination fire nozzle, stbd fire station.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Accommodation/Occupational Safety
Issued 20 February 1996 Resolved
Due to total passenger count exceeding 49, vessel is required to have two (2) operating toilets and sinks, 1 male, 1 female.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Lifesaving
Issued 20 February 1996 Resolved
Install proper sized weak links on life floats.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Navigation
Issued 20 February 1996 Resolved
Install missing cotter pin in steering arm, port side.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Construction/Loadline
Issued 20 February 1996 Resolved
Provide shackle and eye for anchor and anchor line.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Documentation
Issued 20 February 1996 Resolved
Install missing oil pollution placard, install in vicinity of bilge pump inengineroom.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Lifesaving
Issued 20 February 1996 Resolved
Pump out oil from lazzerette/aft steering and engineroom bilges.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Lifesaving
Issued 20 February 1996 Resolved
Replace deteriating life lines on life floats.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Fire Fighting
Issued 20 February 1996 Resolved
Obtain hand operable fire pump capable of pumping minimum 5 gpm.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Accommodation/Occupational Safety
Issued 20 February 1996 Resolved
Mark with arrow and wording all emergency escapes from below deck passengerareas.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Accommodation/Occupational Safety
Issued 20 February 1996 Resolved
Identify plastic piping in bow compartment.
Condition: Unknown
Due 15 January 2002
Resolved 15 January 2002
Resolution: Previously cleared prior to MISLE migration.
Accommodation/Occupational Safety
Issued 20 February 1996 Resolved
Install hull valve in sewage system discharge line, forward machinery space
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Electrical
Issued 20 February 1996 Resolved
Correct improper wire splice in 110v line, located above refrigerator.
Condition: Unknown
Due 24 March 1996
Resolved 24 March 1996
Documentation
Issued 11 September 1995 Resolved
Obtain FCC issued Radio Telephone Certificate, or show intent of compliancewith a copy of completed application and copy of payment.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Lifesaving
Issued 24 February 1995 Resolved
PROVIDE LIFEJACKET LIGHT FOR EACH OF THE REQUIRED PFDS ON BOARD FOR INSPECTION BY CG MARINE INSPECTOR PRIOR TO CARRIAGE OF PASSENGERS OR NO LATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 24 February 1995 Resolved
REPLACE ONE MISSING PADDLE FOR ONE OF THE LIFEFLOATS FOR INSPECTION BY THE CG MARINE INSPECTOR. THIS SHALL BE COMPLIED WITH PRIOR TO CARRIAGE OF PASSENGERS OR NO LATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 24 February 1995 Resolved
PROVIDE 6 RED HAND FLARES AND 6 HAND ORANGE SMOKE DISTRESS SIGNALS IN A WATERTIGHT CONTAINER FOR INSPECTION BY CG MARINE INSPECTOR. THIS SHALL BE COMPLIED WITH PRIOR TO CARRIAGE OF PASSENGERS OR NO LATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 24 February 1995 Resolved
OBTAIN FCC STATION LICENSE BEARING CURRENT VESSEL'S NAME. POST SAME IN THE BRIDGE OR ANY CONSPICOUS LOCATION FOR INSPECTION BY THE CG MARINE INSPECTORPRIOR TO CARRIAGE OF PASSENGERS OR NO LATER THAN 01APR95._x001C_ _x001C_
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 24 February 1995 Resolved
PRIOR TO CARRIAGE OF PASSENGERS ENSURE THAT CG MARINE INSPECTOR EXAMINES AND VERIFIES VESSEL OPERATOR'S LICENSE.
Condition: Unknown
Due 24 February 1995
Resolved 30 January 2002
Resolution: Item previously cleared prior to MISLE migration.
Documentation
Issued 24 February 1995 Resolved
OBTAIN AND POST FOR INSPECTION BY THE CG MARINE INSPECTOR A SAFETY RADIOTELEPHONE CERTIFICATE BEARING VESSEL'S CURRENT NAME. THIS SHALL BE COMPLIED WITH NO LATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 24 February 1995 Resolved
OBTAIN AND POST FOR INSPECTION BY THE CG MARINE INSPECTOR CERTIFICATE OF DOCUMENTATION BEARING VESSEL'S CURRENT NAME. THIS SHALL BE COMPLIED WITH NOLATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
System not recorded
Issued 24 February 1995 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF AND TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR PRIOR TO CARRIAGE OF PASSENGERS OR NO LATER THAN 01APR95.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 6 April 1994 Resolved
Provide weak link for one (of three) life floats. _x001C_ _x001C_ Vessel restricted to maximum of 30 persons until completed._x001C_ _x001C_
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Documentation
Issued 6 April 1994 Resolved
Provide valid FCC Safety Radio Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 7 December 1993 Resolved
INSTALL GLASS GLOBE ON LIGHT IN FORWARD COMPARTMENT.
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Electrical
Issued 7 December 1993 Resolved
CLEAN OIL IN VICINITY OF EXHAUST FAN( LOCATED IN ENGINE ROOM) AND TEST HYDRAULIC LINE FOR LEAKS.
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Electrical
Issued 7 December 1993 Resolved
PROPERLY CONNECT ELECTRICAL WIRES ON A.C. UNIT IN ENGINE ROOM.
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Electrical
Issued 6 April 1992 Resolved
INSTALL BLANK TO COVER MISSING SWITCH ON CIRCUIT BOARD LOCATED IN ENGINE ROOM, STARBOARD SIDE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Documentation
Issued 6 April 1992 Resolved
FORWARD UP TO DATE COPY COPY OF OPERATORS FCC CERTIFICATE TO MSO CORPUS CHRISTI, TEXAS.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Lifesaving
Issued 6 April 1992 Resolved
RENEW GRAB LINE ON STARBOARD AFT RING BUOY, DUE TO WASTAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Fire Fighting
Issued 6 April 1992 Resolved
RENEW THE ERODED BOLT ON FIRE/BILGE PUMP COUPLING, DUE TO WASTAGE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 8 August 1991 Resolved
MAKE PERMENANT REPAIRS TO 3 WELD FRACTURES FOUND IN THE LAZARETTE IN WAY OFTHE STARBOARD CORNER OF THE TRANSOM AT THE DECK LEVEL AND TWO OTHERS IN THETRANSOM STIFFINERS._x001C_
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Engineering
Issued 8 August 1991 Resolved
ISSUED REQUIREMENT TO REMOVE UNAUTHORIZED EXHAUST FAN FROM ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Lifesaving
Issued 16 April 1990 Resolved
STENCIL LIFE RING BUOYS (3) WITH VESSEL NAME.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
PROVIDE FLOAT FREE LINK OF CORRECT SIZE TO VESSEL'S LIFEFLOATS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Engineering
Issued 16 April 1990 Resolved
REPLACED FLAME SCREENS ON VESSEL'S PORT AND STARBOARD FUEL TANK VENTS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 16 April 1990 Resolved
INSTALL RETAINING CLIPS ON PORT AND STARBOARD QUADRANT GEAR PINS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Documentation
Issued 16 April 1990 Resolved
PLACE ON BOARD FCC RADIOTELEPHONE SAFETY CERTIFICATE, FCC STATION LICENSE, AND FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Construction/Loadline
Issued 16 April 1990 Resolved
STENCIL VESSEL'S NAME AND HAILING PORT ON VESSEL STERN.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 16 April 1990 Resolved
PROPERLY ALIGN VESSEL'S NAVIGATION LIGHT BULBS WITHIN LENS. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS REQUIRMENT IS MET.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Construction/Loadline
Issued 16 April 1990 Resolved
REPLACE GASKET IN PORT ENGINEROOM WEATHERTIGHT DOOR.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
STENCIL VESSEL'S LIFEFLOATS (2) WITH VESSEL NAME.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Lifesaving
Issued 16 April 1990 Resolved
STENCIL LIFEFLOAT PADDLES (4) WITH VESSEL NAME.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Engineering
Issued 16 April 1990 Resolved
INSTALL HEAT SHIELDS ON PORT AND STARBOARD GENERATOR AND PORT MAIN ENGINE FUEL FILTERS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Construction/Loadline
Issued 12 March 1990 Resolved
EFFECT PERMANENT REPAIRS TO AFT FUEL TANK IN RUDDER COMPARTMENT.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Lifesaving
Issued 30 September 1983 Resolved
INSTALL GRAB LINES 18 INCHES APART ON ALL LIFE FLOATS.
Condition: Unknown
Due 30 September 1983
Resolved 30 September 1983

Casualty record · 11

24 January 2011Routine · role: Involved in a Marine Casualty · activity 3949651
30 August 2011Routine · role: Involved in a Marine Casualty · activity 4136933
30 August 2011Routine · role: Involved in a Marine Casualty · activity 4136943
7 October 2011Routine · role: Involved in a Marine Casualty · activity 4165077
17 June 2012Routine · role: Involved in a Marine Casualty · activity 4348403
14 May 2015Routine · role: Transiting Vicinity of Primary Subject · activity 5130877
24 March 2016Routine · role: Involved in a Marine Casualty · activity 5839434
10 September 2017Routine · role: Involved in a Marine Casualty · activity 6734297
27 October 2017Routine · role: Involved in a Marine Casualty · activity 6302985
16 July 2021Routine · role: Involved in a Marine Casualty · activity 7260605
4 March 2022Routine · role: Involved in a Marine Casualty · activity 7408400
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.