MAURY USCG vessel records
← All vessels

MANULANI

Built
2005
Last inspected
7 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2026
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9273674
740193
Flag
UNITED STATES
Maury page id
psix-740193

Documentation record

Registered dimensions (L × B × D)661.5 ft × 105.6 ft × 63.6 ft
Registered tonnagegross 32,575 / net 14,558
ITC dimensions (L × B × D)661.5 ft × 105.6 ft × 63.6 ft
ITC tonnagegross 32,575 / net 14,558
BuilderKVAERNER PHILADELPHIA SHIPYARD · PHILADELPHIA, PA, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32575 - Convention (Subpart B), Gross Ton
14558 - Convention (Subpart B), Net Ton
38369 - Dead Weight, Ton
51816 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 178 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TALOFOFO Towing Vessel · MISLE 944367 · 25 May 2022 · activity 7461550

Inspection history · 178

7 April 2026 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8368402
21 February 2026 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8313772
19 February 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312488
19 February 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8315006
8 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8292208
2 January 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8289459
30 December 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8304660
16 December 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8284768
13 December 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8280248
1 December 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8275708
29 November 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8274087
17 November 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8269881
27 October 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8259684
25 October 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8259341
20 October 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8255906
18 October 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8257196
22 September 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8239241
15 September 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8235086
6 September 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8229953
25 August 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8231037
23 August 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8218903
14 August 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8210213
8 August 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8205703
8 August 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8214536
5 August 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8203055
1 August 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8200378
30 July 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8198805
21 July 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8191269
28 June 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8165767
16 June 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8160614
14 June 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8158128
4 June 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8158762
2 June 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8150295
7 May 2025 MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8130522
11 April 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8123671
8 February 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8074155
31 January 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8072552
29 January 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8071629
25 January 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8070679
13 January 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8063074
11 January 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8062256
3 January 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8057280
30 December 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8052960
20 December 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8049828
17 December 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8048443
14 December 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8087686
18 November 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8036643
25 October 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8038300
21 October 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8022477
19 October 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8020802
12 October 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8015783
4 October 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8014626
24 September 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8008450
20 September 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8006711
14 September 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7999665
27 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7990591
22 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7988129
13 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7980634
6 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7976701
23 July 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7965433
22 July 2024 ACP Periodic Oversight · Periodic Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7964127
22 July 2024 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7965769
15 July 2024 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7959176
13 July 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7957407
10 July 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7960133
2 July 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7947570
15 June 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7935472
5 June 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927774
1 June 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7924748
18 May 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7914678
6 May 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7907686
26 April 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7901637
23 April 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7899994
8 April 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7892480
30 March 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888160
25 March 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884820
18 March 2024 Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7881289
16 March 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7878430
26 February 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7870393
24 February 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7869645
14 February 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881313
13 February 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7865156
30 January 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7858282
3 January 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7844747
29 December 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7870668
20 December 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7841072
4 December 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7833528
20 November 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7827691
4 November 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7820210
24 October 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813887
21 October 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7813933
10 October 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7805984
7 October 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7811475
26 September 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7798855
18 August 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7771129
8 August 2023 Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7803686
7 August 2023 Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7760449
29 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7757419
23 July 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7749414
22 July 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7753964
18 July 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7746155
1 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7734140
20 June 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7719040
17 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7722437
7 June 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7708094
5 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7721960
3 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7758315
23 May 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7695165
8 May 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7683725
24 April 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7674940
22 March 2023 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654767
22 March 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7657975
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649117
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649119
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649121
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649127
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649143
9 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648625
9 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648629
9 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648639
9 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648652
23 February 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7645324
14 February 2023 Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624137
14 February 2023 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7657277
24 January 2023 Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7633672
12 January 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7615771
11 September 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7556103
22 August 2022 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7512292
13 June 2022 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7478180
6 June 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7601252
25 May 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7461550
23 May 2022 Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7456869
23 May 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7457029
17 May 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7454223
4 April 2022 ACP COI Oversight · Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7408695
16 July 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7262878
13 July 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7276535
6 July 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7257731
27 April 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7184426
27 April 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7186039
19 April 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7179071
17 March 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7157815
17 March 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7220874
10 December 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7109371
1 September 2020 Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7047228
26 August 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7044420
23 June 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6980719
7 May 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6950665
5 May 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6949268
8 April 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6936817
21 January 2020 Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6891675
4 January 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6900069
2 January 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881907
1 January 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6879312
16 October 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6835348
12 July 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6746836
11 June 2019 Explosive Handling Operation-Administrative
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6710193
28 May 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6690771
6 November 2018 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6575193
26 September 2018 Damage Survey · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6550352
21 August 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6520760
10 August 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6506697
14 May 2018 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6410404
7 May 2018 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6389642
3 April 2018 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6390269
19 February 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385410
13 October 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6290274
10 July 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6732996
27 June 2017 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6190720
5 June 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6166811
22 May 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6152875
18 April 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6122462
8 February 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6086158
4 January 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6066638
23 October 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6030299
3 May 2016 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5853548
23 February 2016 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5821452
27 January 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5807873

Deficiency record · 46

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 February 2026 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Vessel reported loss of ahead propulsion. Make necessary repairs to the satisfaction of attending class surveyor. 74 SOLAS (04) II-1/26.3
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 February 2026
Resolution: ABS attended vessel and witnessed repairs to fuel system and operation test of system to their satisfaction. Vessel is clear to resume normal operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 August 2025 Resolved
(a) No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Operator self-reported crew found cracks in the sea chest for Scrubber unit. Submit repair plan once vessel reach the Port of Honolulu to the sactisfaction of Class and Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2025
Resolved 9 August 2025
Resolution: The piping was back gouged, rewelded and coated.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 May 2025 Resolved
Fire detection and alarm systems shall be kept in good order so as to ensure their required performance if fire occurs. The port side smoke detector in the bridge and the galley fixed call point did not operate. SOLAS 74 (20 cons) II-2/14.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 10 June 2025
Resolution: Class sent report attesting to repalcement and proper operation of the smoke detector and call point.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. MI discovered temporary splice in lighting circuit on switchboard in the ECR. Front panel light on the end of the switchboard. 74SOLAS (04)II-2/45.5.6
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 25 July 2024
Resolution: Accepted by RO
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 July 2024 Resolved
Where ‘‘A’’ class divisions are penetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code. MI discovered unauthorized pipe penetration in the ECR emergency escape trunk. 74SOLAS (04)II-2/9.3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 25 July 2024
Resolution: Accepted by RO
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Handrail leading up to port lifeboat weatherdeck found holed in two places and requires repair. 74 SOLAS (04) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 25 July 2024
Resolution: Accepted by RO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Dead end cable found coiled around speakers on 2nd and 3rd house decks in the passageways. 74 SOLAS (04) II-1/40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 25 July 2024
Resolution: Accepted by RO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
All electric cables and wiring external to equipment shall be at least of a flame-retardant type and shall be so installed as not to impair their original flame-retarding properties. MI discovered electrical extension cord permanently affixed in the Steering Gear Room. 74SOLAS (04)II-2/45.5.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 July 2024
Resolution: Cord removed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 July 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port side lifeboat aft gripe cable found with broken individual strands of wire cable. 74 SOLAS (14) III/20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 July 2024
Resolution: Crew replaced gripe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Port side weatherdeck light on 02 deck broke away from mounting bracket and found unsecured. 74 SOLAS (04) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 July 2024
Resolution: Crew remounted light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2024 Resolved
Ships shall be designed, constructed, and maintained in compliance with structural mechanical and electrical requirements of a classification society which is recognized by the Administration. Marine Inspectors identified two soft patches on 4 foot section of greywater piping in the starboard side of the engine room. 74 SOLAS 2004 II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2024
Resolved 26 April 2024
Resolution: Piping was cropped and renewed and accepted by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
THE MACHINERY... SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. VESSEL REPORTED ITS MAIN PROPULSION ENGINE HAD LOST ASTERN CAPABILITY AND WAS NOT FUNCTIONING AS DESIGNED. VESSEL IS ENROLLED IN USCG ACP PROGRAM AND REPAIRS SHALL BE COMPLETED TO THE SATISFACTION OF ATTENDING CLASS SURVEYOR, VESSEL MUST PROVIDE SATISFACTORY CLASS REPORT PRIOR TO DEPARTURE FROM SECTOR PUGET SOUND COTP ZONE. SOLAS 74 (2004 CONS)CHAPTER II/1 REG 26; 17A,C
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2023
Resolution: Vessel provided satifactory ABS Class surveyor report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 August 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect...including...in paint lockers, unless the Administration is satisfied that such equipment is: appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Marine Inspectors found the following non-intrinsically safe electrical equipment in the forward paint locker: karaoke machine, corded drills for paint mixing, daisy chained cords, battery powered tools and a heat lamp. Remove items or replace with intrinsically safe alternatives. 74 SOLAS (04) II-1/45.10.4
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 15 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 August 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During retrieval of port life boat, forward davit was found to have a vibration that transferred oscillations to the falls. Determine cause of vibrations and make repairs to the satisfaction of RO. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 August 2023 Resolved
The purpose of this regulation is to limit fire growth potential in every space of the ship. For this purpose, the following functional requirements shall be met: means of control for flammable liquids in the space shall be provided. During inspection, Marine Inspector found open cans of paint and a plastic/open top trash can full of used paint cleaning rags and solvents. 74 SOLAS (09) II-2/5.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 August 2023 Resolved
The following protection systems shall be kept in good order so as to ensure their required performance if fire occurs: structural fire protection, including fire resistant divisions, and protection of opening and penetrations in these divisions. During inspection, Marine Inspector found stairwell fire service door at 03 Deck would not self close. 74 SOLAS (09) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 August 2023 Resolved
The safe passage of crew shall be provided by at least one of the means prescribed in table 25-1.1. During inspection, marine Inspector found a storm rail next to aft davit of port life boat that was wasted and had a sharp edge. Additionally, forward end of cargo hold 05 was found to have broken wire rope lifelines. ICLL(88) III/25-1(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 7 August 2023 Resolved
Where bulwarks on the weather portions of freeboard or superstructure form wells, ample provision shall be made for rapidly freeing the decks of water and for draining them. During inspection, Marine Inspector found starboard side/amid-ships scupper blocked with debris. ICLL(88) III/24(1)(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 August 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 August 2023 Resolved
The following protection systems shall be kept in good order so as to ensure their required performance if fire occurs: structural fire protection, including fire resistant divisions, and protection of opening and penetrations in these divisions. During Inspection, Marine Inspector found multi-cable transit missing stuffing material for shore power cable penetration through bulkhead. 74 SOLAS (09) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 August 2023
Resolution: Crew repaired while inspectors onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 February 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. The bracket to the smoke detector in the fuel purifier room is broken and being supported by the power cord.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2023
Resolution: Cleared by Class; Finding No. 1631.0, ABS Preliminary Report No. 5688796.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 February 2023 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Identified oil soaked lagging on high pressure pump in fuel oil purfier room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 22 March 2023
Resolution: Pernament repairs verified by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 February 2023 Resolved
tairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-"0" class divisions and be protected by self-closing doors at all levels. Main stairway in accomodation space doors do not sefl-close and latch properly at deck 1,2,4,5, and 6.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2023
Resolution: Cleared by Class; Finding No. 1631.0, ABS Preliminary Report No. 5688796
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 4 April 2022 Resolved
All external openings leading to compartments assumed intact in the damage analysis which are below the final damage waterline are required to be watertight. MI found cargo hatch vent closures unserviceable on hatches 4,5 and 6. Vessel to prove watertight all vent closures.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 11 April 2022
Resolution: Accepted as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022 Resolved
No less than 1/2 of lifebuoys shall be provided with self-igniting lights. Prove proper operation of the lifebuoy light located STBD side just forward of the gangway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2022
Resolved 4 April 2022
Resolution: The ships crew replaced the water light battery, test SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 April 2022 Resolved
Condition after survey, MI found an overhead light fixture unsecured STBD side 2nd deck exterior. Provide proper mounting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 11 April 2022
Resolution: Accepted as a condition of class.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 April 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found steering pump motor controllers 1 and 2 with their bottoms cutout. Provide intact motor controller boxes/enclosures.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 11 April 2022
Resolution: Accepted as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 April 2021 Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. Marine Inspector found 03 Hydrostatic releases installed incorrectly on the Ship's port (2) and bow (1)liferafts. The hydrostatic releases appeared to have been installed incorrectly (upside down) during the liferafts installation of June 2020. 74SOLAS III/13.4.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 April 2021
Resolved 19 April 2021
Resolution: Ship's force removed the upside down hydrostatic releases and reinstalled as per design.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 April 2021 Resolved
Each liferaft shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. Marine Inspector found 03 Hydrostatic releases installed incorrectly on the Ship's port (2) and bow (1)liferafts. The hydrostatic releases appeared to have been installed incorrectly during the liferafts installation of June 2020. MI requested to have the releases corrected imediatley. Chief mate agreed and inform the MI the liferafts are inspected weekly and the crew nor himself noticed the releases installed incorrectly. CG is requiring an internal audit of its life saving inspection procedures and a corrective action within 90 days. 74SOLAS III/13.4.2 LSA 4.1.6
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 July 2021
Resolved 13 July 2021
Resolution: SQE Specific Oversight Audit report uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2020 Resolved
Lifejackets shall be so placed as to be readily accessible and their position shall be plainly indicated. Placarding was missing from lifejacket stowage location in engine control room. 74 SOLAS (04) III/7.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
Resolution: Placards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 January 2020 Resolved
Immersion suits shall be so placed as to be readily accessible and their position shall be plainly indicated. Placards indicating immersion suit stowage location were missing in the Engine Control Room. 74 SOLAS (14) III/32/3.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
Resolution: Placards installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 21 January 2020 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. MI witnessed crewmembers unable to communicate with each other during a fire drill and tangled hoses during drill. 74 SOLAS (14) II-2/15/2.2.1
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
Resolution: MI conducted training with fire teams and Chief Mate regarding fire fighting procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 January 2020 Resolved
All life-saving applicances shall be in working order. 3 rations from the Port lifeboat were missing.
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 21 January 2020 Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least 3 courses. Courses on rail by port lifeboat embarkation deck are broken. 66 ICLL Reg. 25
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
Resolution: Course repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2020 Resolved
Lifebuoys must comply with the LSA Code. Retro-reflective tape on 3 buoys on stbd forward deck are degraded and need replacement.
Action required: 10 - Deficiency Rectified
Due 21 January 2020
Resolved 21 January 2020
Resolution: Replacement tape installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 May 2019 Resolved
The auxiliary steering gear shall be of adequate strength and capable of steering the ship at navigable speed. Repair #2 steering pump (emergency) so that it can be powered by the emergency switchboard. 74SOLAS(04) II-1/29.4.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 May 2019
Resolved 28 May 2019
Resolution: Received satisfactory class report LA3675810-D from ABS attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 May 2019 Resolved
The following shall be tested in accordance with the fire test procedures code: fire dampeners, including their relative means of operation. Repair inoperable engine room inlet fire dampener. 74SOLAS(04) II-2/9.7.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2019
Resolved 28 May 2019
Resolution: Received satisfactory class report LA3675810-D from ABS attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 May 2019 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Remove hold-back devices on both doors leading to purifier room. 74SOLAS(04) II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 May 2019
Resolved 28 May 2019
Resolution: Deficiency rectified to the satisfaction of the attending MI.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 28 May 2019 Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration. MI witnessed crew and contractors using simple green in the engine room. Do not permit use of Simple Green where it would contaminate bilge water because is not an approved cleaner in accordance with the OWS manufacturer’s instructions. MARPOL I/14.6
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 May 2019
Resolved 28 May 2019
Resolution: Deficiency rectified to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2018 Resolved
Propulsion control from the Navigating Bridge is to be provided. Vessel reported an EOT automation fault on the bridge control station causing the command of dead slow ahead/astern to give slow ahead/astern. All other speeds are unaffected from the bridge control station. Engine Control Room retains normal operation of the EOT. Conduct repairs to bridge control station and prove proper operation of all speeds ahead/astern from bridge control station.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 November 2018
Resolution: See Tech and ABS reports in deficiency documents.
Engineering › Compressed Air System (start air) › Valve
Issued 22 May 2017 Resolved
Replace relief valves identified to exceed the Maximum Allowable Working Pressure (MAWP) on the following pressure vessels: start air receivers and compressors, high pressure fuel buffer tank, DG start air tank, emergency generator receiver tank. Provide a substantial lifting device for each valve.
Action required: 705 - Other - as specified
Due 30 July 2017
Resolved 23 April 2018
Resolution: Received satisfactory report from ABS and Port engineer identifying replacement of all required relief valves.
Engineering › Compressed Air System (start air) › Valve
Issued 18 April 2017 Resolved
Provide a class report from ABS concerning relief valves on start air receivers /tanks and compressors, buffer tanks high pressure fuel, DG start air tank, emergency generator receiver tank, to include hand relif devices.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2017
Resolution: Received class report and outstanding condition of class was issued.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 18 April 2017 Resolved
Provide all vent outlets for fuel tanks with either two 20x20 mesh wire screens with 05.-1.5 inch between, or one 30x30 inch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 5 June 2017
Resolution: Received satisfactory class report confirming replacement of all fuel/ oil tank vent screens with 30 x 30 mesh.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2017 Resolved
Provide proper ring buoy light line for all ring buoys, dark synthetic or ultraviolet resistant.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 5 June 2017
Resolution: Received a satisfactory class report confirming replacement of ring buoy line with the approved type.
Engineering › Fuel Oil Service System › Pump
Issued 7 June 2016 Resolved
Prove proper operation of the #2 main engine low pressure fuel oil supply pump to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Replaced mechanical shaft seal.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 June 2016 Resolved
Repair A-60 fire door hinge to electrical instruments locker on the 01 Deck to the satisfaction of Class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Re-welded hinge to door.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 June 2016 Resolved
Identified 02 inoperable smoke detectors in the engine room. Vessel is unmanned ER at night.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Readjusted pins between base and head to complete full contact.

Ownership record