Records from 1991 to 2016. Most recent: operational control imposed, 27 July 2016.
Inspection history · 23
27 July 2016
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5955361
6 April 2016
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5850054
15 December 2015
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5781968
6 April 2014
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4830629
25 July 2006
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2724323
19 July 2006
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2717909
20 July 2002
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1651191
9 April 2002
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1603098
1 December 2000
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 153128
25 September 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 161650
11 August 1995
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 20748
9 March 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259719
17 August 1991
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 939602
15 August 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 676023
23 July 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252095
18 June 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198036
18 June 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250519
16 May 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221957
30 April 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213177
6 April 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942700
30 March 1991
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1224307
1 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1211035
26 February 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342197
Construction/Loadline
Issued 18 June 1991
Resolved
PROVIDE METALLIC BAND STRAPPING (AT LEAST 5/8" WIDE BY .015" THICK) IN WAY OF ALL NYLON/PLASTIC STRAPPING NOT MORE THAN 24" APART ON ALL HORIZONTAL WIRING RUNS ON CERTERLINE OF DECK.
Condition: Unknown
Due 15 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 March 1991
Resolved
REPAIR AND PROVE OPERATION OF ALL BALLAST TANK CLOSED GAUGING SYSTEMS.
Condition: Unknown
Due 30 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 30 March 1991
Resolved
PROVIDE USCG APPROVED STABILITY LETTER. VESSEL SHALL NOT BE LOADED WITH CARGO UNTIL STABILITY LETTER HAS BEEN ISSUED.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Deck/Cargo
Issued 30 March 1991
Resolved
PROVE OPERATION OF REVERSE POWER TRIPS OF GENERATORS. GENERATORS SHALL NOT BE OPERATED SIMULTANEOUSLY UNTIL A USCG MARINE INSP HAS WITNESSED PROPER OPERATION OF REVERSE POWER TRIPS AND PARALLELING GENERATORS.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Electrical
Issued 30 March 1991
Resolved
PROVIDE METALLIC BAND STRAPPING (AT LEAST 5/8" WIDE BY .015" THICK) IN WAY OF ALL NYLON/PLASTIC STRAPPING NOT MORE THAN 24" APART ON ALL HORIZONTAL WIRING RUNS ON CENTERLINE OF DECK.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Electrical
Issued 30 March 1991
Resolved
PROVIDE DIAGRAMS (DRAWINGS) OF ALL ELECTRICAL WIRING TO USCG MARINE SAFETY CENTER FOR REVIEW AND APPROVAL. ALL WIRING REMOVED FROM THE BARGE SHALL BE OMITTED FROM DIAGRAM.
Condition: Unknown
Due 15 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 30 March 1991
Resolved
DEMONSTRATE SHUTDOWNS OF CARGO PUMPS PRIOR TO USING CARGO PUMPS.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Deck/Cargo
Issued 30 March 1991
Resolved
PROVIDE DRAWING OF ALL CARGO PIPING TO USCG MARINE SAFETY CENTER FOR REVIEWAND APPROVAL. ALL PIPING REMOVED FROM VESSEL SHALL BE OMITTED FROM DRAWING.
Condition: Unknown
Due 15 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 30 March 1991
Resolved
PROVIDE NEWLY INSTALLED FIRE ALARM SYSTEM DRAWINGS TO USCG MARINE SAFETY CENTER FOR REVIEW AND APPROVAL. POWER SHALL REMAIN DISCONNECTED UNTIL APPROVED.
Condition: Unknown
Due 15 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 30 March 1991
Resolved
PROVIDE USCG APPROVED "INFORMATION FOR MASTER" AS PER 33CFR157.47, (STABILITY, DAMAGE STABILITY AND LOADING INFORMATION) PRIOR TO LOADING CARGO AT A U.S. PORT.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991