Inspection history · 30
30 October 2023
Administrative Inspection · Uninspected Other
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7825441
17 December 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7383849
7 January 2021
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7121138
12 October 2020
Periodic Inspection · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7075896
18 November 2019
Administrative Inspection · Annual Inspection · In-Service Inspection · Internal Structural Exam · Drydock Extension · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6857510
26 September 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6821657
17 September 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6814094
19 July 2019
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6758114
18 June 2019
Deficiency Check · Examination of Repairs · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6717776
5 June 2019
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6704545
29 May 2019
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6698132
29 May 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6701777
21 May 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6690524
8 May 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6679353
6 May 2019
Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6677692
30 April 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6673239
17 April 2019
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6664752
16 April 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6663692
26 November 2018
Deficiency Check · Periodic Inspection · In-Service Inspection · Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6648422
27 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6492327
24 July 2018
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6532638
1 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6405707
1 May 2018
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6482485
24 January 2018
Examination of Repairs · Deficiency Check · Plan Review (Other than "T") · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6375718
28 November 2017
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6314223
27 November 2017
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6313094
30 October 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6297691
22 December 2016
Deficiency Check · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6061441
6 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5886451
25 January 2016
Examination of Repairs · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5803080
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 October 2020
No resolution recorded
Crop and renew area of stress cracking, in the vicinity of cargo hold #3, and the starboard storm tunnel.
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2020
No resolution recorded
#2 stbd Ballast Tank frame #50 box patch: Submit repair proposal to the cognizant OCMI for approval of permanent repairs. Repairs shall be completed to the satisfaction of the attending CGMI/Class Surveyor prior to 31MAR2021.
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 21 January 2020
Resolved
Make area of contact with crane available for inspection. Replace lifeline stanchions & cables.
Action required: 705 - Other - as specified
Due 21 January 2020
Resolved 18 February 2020
Resolution: Received notification from POC that two stanchions and life lines have been replaced. Visual inspection of area completed by MI 01/21/2020 with no notable damage except for above replaced items.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 June 2019
Resolved
Provide conclusive manufacturer failure analysis into steering mode failures when in follow up mode. Vessel shall be operated in NFU while in restricted waters until conclusion and rectification is completed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2019
Resolution: New rudder feed back potentiometers were installed and revised DVTP testing satisfactorily completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 May 2019
Resolved
29 MAY 2019 while underway in the Detroit River, the vessel experienced an issue with the steering system in follow up mode occurred. Follow up steering was not working as designed, causing the rudder to be stuck hard over. While in port the vessel tested the steering in all modes, and it is now working as designed. Company/Vessel shall have a tech attend and attest to steering gear is operating normally, and provide tech report to the satisfaction of the US Coast Guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 3 June 2019
Resolution: Technician report attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2019
Resolved
Steering pump malfunction. System works in all modes with the exception of FU maode while on the port pump.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 8 May 2019
Resolution: Received tech report attesting to completion of repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 April 2019
Resolved
16APR2019 while the vessel was underway in the St. Clair River, an issue with the steering system in follow up mode occurred. Follow up steering is not working as designed. Vessel is using non-follow up steering only now. Company/Vessel shall have a tech
attend and attest to steering gear is operating
normally.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 17 April 2019
Resolution: Vessel Captain provided tech report attesting to completed repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2018
Resolved
Auxillary boiler is not to be used until proper operation of main steam safety is demonstrated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Witnessed satisfactory testing of the steam safety relief valve.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 1 May 2018
Resolved
Emergency Generator did nottake load during a black out. Prove proper operation of emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: Witnessed proper operation of emergency generator
Construction/Loadline › Penetrations › Gasket
Issued 23 March 2018
Resolved
Renew where remaining all worn, cracked, or painted port light gaskets per survey dated 2/8/2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 26 April 2018
Resolution: Received an e-mail from vessels Master stating all worn port light gaskets has been addressed. The gaskets have been replaced. Requirement satisfied and cleared
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 23 March 2018
Resolved
Rescue Boat, unable to launch due to vessels moored stbd side to dock wall. In presence of a CG Marine Inspector; Lower, release, operate, retrieve, and stow the vessels Rescue Boat.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 1 May 2018
Resolution: Witnessed launching and recovery or rescue boat.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 23 March 2018
Resolved
Revise and submit the Boiler PSTP to attending CG Marine Inspector to reflect proper alarms and set points.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 18 April 2018
Resolution: Received Rev 4 of the vessels PSTP from vessels [name withheld] acceptable an approval letter will be submitted for [name withheld] signature
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 23 March 2017
Resolved
Port forward Life raft embarkation ladder, observed to short and would not reach the waterline at vessels highest sea going condition (w/fwd draft at 15ft 6 inches) when listed 15 degrees. Per 46 CFR 199.110(f), renew embarkation ladder with a 40 foot, 160.017 or 160.117 CG approved ladder.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement & Cert reflecting a new CG approved 42 foot ladder was installed.
Navigation › Piloting/Steering › Swing Meter
Issued 23 March 2017
Resolved
Observed pilot house steering stand, rudder angle indicator was off by five degrees, recalibrate and provide supporting documentation to CG Marine Inspector as required by 46 CFR 113.40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement, & attached service report reflecting the steering stand rudder indicator was recalibrated.
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 23 March 2017
Resolved
Launching instructions missing in the vicinity of the Rescue Boat, post signs near the Rescue Boat as required by 46 CFR 199.90
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 29 March 2017
Resolution: Verified via emails with vessels Master Placards in place
Lifesaving › Launching Appliances › Davit
Issued 23 March 2017
Resolved
Crews knowledge of lowering the Rescue Boat appeared minimal, conduct training with crew as required by 46 CFR 199.180
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 24 March 2017
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 23 March 2017
Resolved
In the presence of a CG Marine Inspector lower, operate, and raise the Rescue Boat as required by 46 CFR 199.160
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 24 March 2017
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 23 March 2017
Resolved
The vessels current Periodic Safety Tests Procedures (PSTP), Revision 2, dated 5/30/2001, paragraph 5. Electrical Power procedures is incomplete. IAW 46 CFR 61.40-6 or NVIC 1-69, company shall revise and submit the PSTP’s to USCG Marine Safety Center for review and approval.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 March 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 23 March 2017
Resolved
Observed isolation valve for emergency hand pump serving the main day tank failed during operational test of reach rod. Valve failed in the closed position. IAW 46 CFR 56.50-60(d), renew or make effective repairs to the valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement & attached photo reflecting the transfer valve on the fuel oil service system was replaced.
Engineering › Steam Boiler (propulsion) › Pump
Issued 23 March 2017
Resolved
Unable to trip main propulsion boiler steam driven Coffin feed water pump. IAW 46 CFR 56.50-35, make repairs and demonstrate proper operation of the over speed trip and hand tripping device.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2017
Resolved 23 March 2017
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 26 March 2016
Resolved
Renew wasted pipe on FWD water heater; prove leak free operation. 46 CFR 56.97-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: Wasted piping was replaced on the fwd water heater. Photos and statement from Chief Engineer accepted as proof of completion.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 26 March 2016
Resolved
Renew wasted pipe for hot water supply to FWD house in bow thruster room overhead. 46 CFR 56.97-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: Wasted pipe in the overhead was replaced in kind. Statement and photos from the Chief Engineer were accepted as proof of completion.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 March 2016
Resolved
Make repairs to the AFT paint locker vent. 46 CFR 95.15-4
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: The vent pipe on the main deck was fitted with a new cap and screw down assembly to ensure proper closure and to prevent possible down flooding. Statement and photos from Chief Engineer were accepted as proof of completion.
Fire Fighting › Fire Hydrants › Material
Issued 26 March 2016
Resolved
Replace fractured valve on AFT Fire Station.
Condition: Improper/Lack of Maintenance
Due 26 April 2016
Resolved 27 March 2016
Resolution: Verified fractured valve on aft fire station was renewed.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 26 March 2016
Resolved
Demonstrate proper operation of the aft anchor brakes and release aft anchor to the satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 27 March 2016
Resolution: Met with vessels Mate, verified proper operation of the aft anchor.
Fire Fighting › Ventilation Systems › Fans
Issued 25 January 2016
Resolved
Prove proper operation of bow thruster room ventilation CO2 shutdown. 46 CFR 95.15-35
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2016
Resolution: Conducted operational test of ventilation shutdown for bow thruster space.
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2016
Resolved
Prove proper operation of #1 generator, parallel operation and reverse power relay. 46 CFR 111.12-11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2016
Resolution: EATON service rep attended vessel and repalced spring within breaker. Conducted operational test for paralleling and reverse power relay, all sat.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 25 January 2016
Resolved
Prove proper overcurrent protection for the #1, 2 & 3 generators. (requires breakers to be sent to EATON facility to be properly cleaned and serviced)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 23 March 2017
Resolution: Port Engineer provided four breaker servicing reports. Reports from Crown Eram LLC, Crown Point, IN all dated 2/28/2017. All reflecting breakers were serviced, repaired as required, with Digitrip tested at 110%, and all breakers ready for service.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 25 January 2016
Resolved
Demonstrate proper operation, lower to water and retrieve the rescue boat to the satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 27 March 2016
Resolution: Witnessed two crewmembers in the Rescue Boat, lowered to water, released, operated, raised and placed in the cradle.