MAURY USCG vessel records
← All vessels

CASON J. CALLAWAY

Built
1952
Last inspected
30 October 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 October 2023
…with no type recorded5
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5065392
WDH7556
Flag
UNITED STATES
Maury page id
psix-42789

Documentation record

Registered dimensions (L × B × D)749.4 ft × 70.2 ft × 31.3 ft
Registered tonnagegross 12,309 / net 9,332
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREAT LAKES ENGINEERING · RIVER ROUGE, MI, UNITED STATES · built 1952
Hull materialSteel
PropulsionSteam Turbine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDULUTH, MN
Endorsements, as the file codes themcw_ch, reg
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12309 - Regulatory (Subpart C or D), Gross Ton
9332 - Regulatory (Subpart C or D), Net Ton
26778 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 29 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

30 October 2023 Administrative Inspection · Uninspected Other
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7825441
17 December 2021 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7383849
7 January 2021 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7121138
12 October 2020 Periodic Inspection · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7075896
18 November 2019 Administrative Inspection · Annual Inspection · In-Service Inspection · Internal Structural Exam · Drydock Extension · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6857510
26 September 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6821657
17 September 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6814094
19 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6758114
18 June 2019 Deficiency Check · Examination of Repairs · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6717776
5 June 2019 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6704545
29 May 2019 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6698132
29 May 2019 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6701777
21 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6690524
8 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6679353
6 May 2019 Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6677692
30 April 2019 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6673239
17 April 2019 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6664752
16 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6663692
26 November 2018 Deficiency Check · Periodic Inspection · In-Service Inspection · Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6648422
27 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6492327
24 July 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6532638
1 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6405707
1 May 2018 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6482485
24 January 2018 Examination of Repairs · Deficiency Check · Plan Review (Other than "T") · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6375718
28 November 2017 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6314223
27 November 2017 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6313094
30 October 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6297691
22 December 2016 Deficiency Check · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6061441
6 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5886451
25 January 2016 Examination of Repairs · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5803080

Deficiency record · 29

02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 October 2020 No resolution recorded
Crop and renew area of stress cracking, in the vicinity of cargo hold #3, and the starboard storm tunnel.
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2020 No resolution recorded
#2 stbd Ballast Tank frame #50 box patch: Submit repair proposal to the cognizant OCMI for approval of permanent repairs. Repairs shall be completed to the satisfaction of the attending CGMI/Class Surveyor prior to 31MAR2021.
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 21 January 2020 Resolved
Make area of contact with crane available for inspection. Replace lifeline stanchions & cables.
Action required: 705 - Other - as specified
Due 21 January 2020
Resolved 18 February 2020
Resolution: Received notification from POC that two stanchions and life lines have been replaced. Visual inspection of area completed by MI 01/21/2020 with no notable damage except for above replaced items.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 June 2019 Resolved
Provide conclusive manufacturer failure analysis into steering mode failures when in follow up mode. Vessel shall be operated in NFU while in restricted waters until conclusion and rectification is completed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2019
Resolution: New rudder feed back potentiometers were installed and revised DVTP testing satisfactorily completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 May 2019 Resolved
29 MAY 2019 while underway in the Detroit River, the vessel experienced an issue with the steering system in follow up mode occurred. Follow up steering was not working as designed, causing the rudder to be stuck hard over. While in port the vessel tested the steering in all modes, and it is now working as designed. Company/Vessel shall have a tech attend and attest to steering gear is operating normally, and provide tech report to the satisfaction of the US Coast Guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 3 June 2019
Resolution: Technician report attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2019 Resolved
Steering pump malfunction. System works in all modes with the exception of FU maode while on the port pump.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 8 May 2019
Resolution: Received tech report attesting to completion of repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 April 2019 Resolved
16APR2019 while the vessel was underway in the St. Clair River, an issue with the steering system in follow up mode occurred. Follow up steering is not working as designed. Vessel is using non-follow up steering only now. Company/Vessel shall have a tech attend and attest to steering gear is operating normally.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 17 April 2019
Resolution: Vessel Captain provided tech report attesting to completed repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2018 Resolved
Auxillary boiler is not to be used until proper operation of main steam safety is demonstrated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Witnessed satisfactory testing of the steam safety relief valve.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 1 May 2018 Resolved
Emergency Generator did nottake load during a black out. Prove proper operation of emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: Witnessed proper operation of emergency generator
Construction/Loadline › Penetrations › Gasket
Issued 23 March 2018 Resolved
Renew where remaining all worn, cracked, or painted port light gaskets per survey dated 2/8/2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 26 April 2018
Resolution: Received an e-mail from vessels Master stating all worn port light gaskets has been addressed. The gaskets have been replaced. Requirement satisfied and cleared
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 23 March 2018 Resolved
Rescue Boat, unable to launch due to vessels moored stbd side to dock wall. In presence of a CG Marine Inspector; Lower, release, operate, retrieve, and stow the vessels Rescue Boat.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 1 May 2018
Resolution: Witnessed launching and recovery or rescue boat.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 23 March 2018 Resolved
Revise and submit the Boiler PSTP to attending CG Marine Inspector to reflect proper alarms and set points.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 18 April 2018
Resolution: Received Rev 4 of the vessels PSTP from vessels [name withheld] acceptable an approval letter will be submitted for [name withheld] signature
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 23 March 2017 Resolved
Port forward Life raft embarkation ladder, observed to short and would not reach the waterline at vessels highest sea going condition (w/fwd draft at 15ft 6 inches) when listed 15 degrees. Per 46 CFR 199.110(f), renew embarkation ladder with a 40 foot, 160.017 or 160.117 CG approved ladder.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement & Cert reflecting a new CG approved 42 foot ladder was installed.
Navigation › Piloting/Steering › Swing Meter
Issued 23 March 2017 Resolved
Observed pilot house steering stand, rudder angle indicator was off by five degrees, recalibrate and provide supporting documentation to CG Marine Inspector as required by 46 CFR 113.40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement, & attached service report reflecting the steering stand rudder indicator was recalibrated.
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 23 March 2017 Resolved
Launching instructions missing in the vicinity of the Rescue Boat, post signs near the Rescue Boat as required by 46 CFR 199.90
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 29 March 2017
Resolution: Verified via emails with vessels Master Placards in place
Lifesaving › Launching Appliances › Davit
Issued 23 March 2017 Resolved
Crews knowledge of lowering the Rescue Boat appeared minimal, conduct training with crew as required by 46 CFR 199.180
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 24 March 2017
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 23 March 2017 Resolved
In the presence of a CG Marine Inspector lower, operate, and raise the Rescue Boat as required by 46 CFR 199.160
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 24 March 2017
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 23 March 2017 Resolved
The vessels current Periodic Safety Tests Procedures (PSTP), Revision 2, dated 5/30/2001, paragraph 5. Electrical Power procedures is incomplete. IAW 46 CFR 61.40-6 or NVIC 1-69, company shall revise and submit the PSTP’s to USCG Marine Safety Center for review and approval.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 March 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 23 March 2017 Resolved
Observed isolation valve for emergency hand pump serving the main day tank failed during operational test of reach rod. Valve failed in the closed position. IAW 46 CFR 56.50-60(d), renew or make effective repairs to the valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Received e-mail from Master with statement & attached photo reflecting the transfer valve on the fuel oil service system was replaced.
Engineering › Steam Boiler (propulsion) › Pump
Issued 23 March 2017 Resolved
Unable to trip main propulsion boiler steam driven Coffin feed water pump. IAW 46 CFR 56.50-35, make repairs and demonstrate proper operation of the over speed trip and hand tripping device.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2017
Resolved 23 March 2017
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 26 March 2016 Resolved
Renew wasted pipe on FWD water heater; prove leak free operation. 46 CFR 56.97-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: Wasted piping was replaced on the fwd water heater. Photos and statement from Chief Engineer accepted as proof of completion.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 26 March 2016 Resolved
Renew wasted pipe for hot water supply to FWD house in bow thruster room overhead. 46 CFR 56.97-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: Wasted pipe in the overhead was replaced in kind. Statement and photos from the Chief Engineer were accepted as proof of completion.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 March 2016 Resolved
Make repairs to the AFT paint locker vent. 46 CFR 95.15-4
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 6 April 2016
Resolution: The vent pipe on the main deck was fitted with a new cap and screw down assembly to ensure proper closure and to prevent possible down flooding. Statement and photos from Chief Engineer were accepted as proof of completion.
Fire Fighting › Fire Hydrants › Material
Issued 26 March 2016 Resolved
Replace fractured valve on AFT Fire Station.
Condition: Improper/Lack of Maintenance
Due 26 April 2016
Resolved 27 March 2016
Resolution: Verified fractured valve on aft fire station was renewed.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 26 March 2016 Resolved
Demonstrate proper operation of the aft anchor brakes and release aft anchor to the satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 27 March 2016
Resolution: Met with vessels Mate, verified proper operation of the aft anchor.
Fire Fighting › Ventilation Systems › Fans
Issued 25 January 2016 Resolved
Prove proper operation of bow thruster room ventilation CO2 shutdown. 46 CFR 95.15-35
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2016
Resolution: Conducted operational test of ventilation shutdown for bow thruster space.
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2016 Resolved
Prove proper operation of #1 generator, parallel operation and reverse power relay. 46 CFR 111.12-11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2016
Resolution: EATON service rep attended vessel and repalced spring within breaker. Conducted operational test for paralleling and reverse power relay, all sat.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 25 January 2016 Resolved
Prove proper overcurrent protection for the #1, 2 & 3 generators. (requires breakers to be sent to EATON facility to be properly cleaned and serviced)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 23 March 2017
Resolution: Port Engineer provided four breaker servicing reports. Reports from Crown Eram LLC, Crown Point, IN all dated 2/28/2017. All reflecting breakers were serviced, repaired as required, with Digitrip tested at 110%, and all breakers ready for service.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 25 January 2016 Resolved
Demonstrate proper operation, lower to water and retrieve the rescue boat to the satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 27 March 2016
Resolution: Witnessed two crewmembers in the Rescue Boat, lowered to water, released, operated, raised and placed in the cradle.

Ownership record