Records from 1993 to 2026. Most recent: inspection, 3 August 2026.
Inspection history · 152
3 August 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8453667
22 July 2026
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8444236
5 June 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8392550
28 May 2026
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8382401
16 April 2026
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8350732
13 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8346811
6 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8343357
30 March 2026
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8334077
30 March 2026
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8344717
30 December 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8288317
16 December 2025
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8284327
14 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8283996
12 December 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8282707
11 December 2025
Administrative Inspection · Deficiency Check · Annual Survey · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8282069
9 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8156099
7 June 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8154137
17 January 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8064983
17 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8065034
27 December 2024
Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8051175
20 September 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8006144
15 September 2024
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8002738
7 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7998283
26 August 2024
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7989527
28 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7944209
14 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7935008
28 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7922879
24 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7918273
13 May 2024
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7911229
30 April 2024
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7904333
9 April 2024
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7892936
2 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7888988
2 April 2024
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7891598
2 April 2024
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7911602
29 March 2024
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7887134
28 March 2024
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7888163
26 February 2024
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7870224
17 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7850311
1 December 2023
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7832131
23 September 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7797007
23 September 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7798103
18 September 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7793489
3 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7783751
2 September 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7784836
21 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7774928
13 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7767254
31 July 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7756858
22 July 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7751281
11 July 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7741291
4 July 2023
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7738305
21 May 2023
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7693177
18 May 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7691308
18 May 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7692384
25 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7675676
22 April 2023
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7676661
6 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7664182
1 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7661754
11 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7639524
15 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7478588
8 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7472118
17 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7433060
14 April 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7431217
13 April 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7430484
14 January 2022
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7380414
14 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7381533
11 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7639530
3 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7374944
25 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7372540
7 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7363711
7 December 2021
Internal Structural Exam · Annual Inspection · Drydock Extension
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7392607
29 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7359384
26 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7358751
14 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7311857
10 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7324153
6 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7306297
2 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7302671
27 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7303381
20 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7292118
18 August 2021
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7290528
18 August 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7291285
16 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7288077
10 August 2021
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7285562
6 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7279053
30 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7274914
26 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7268557
24 June 2021
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7343207
17 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7205453
9 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7205398
4 May 2021
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7188806
4 May 2021
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7188899
21 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7180075
19 April 2021
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7178150
2 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7169205
17 February 2021
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7141886
17 December 2020
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7113293
14 December 2020
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7111981
6 November 2020
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7090816
17 August 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7035913
16 August 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7035616
27 April 2020
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6944458
9 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6937752
2 April 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6939445
3 February 2020
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6907987
3 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6883353
27 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6879709
23 December 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6878337
7 October 2019
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6830414
10 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6808098
11 July 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6746284
11 July 2019
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6746638
11 July 2019
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6754115
29 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6699096
6 May 2019
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6677734
6 May 2019
Examination of Repairs · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6677758
25 April 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6671103
25 April 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6672737
18 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6665282
12 April 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6663297
29 March 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6653940
26 March 2019
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6652434
26 March 2019
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6663676
5 February 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6621783
28 January 2019
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6621773
9 January 2019
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6608128
9 January 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6608152
9 January 2019
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6608731
5 September 2018
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6542559
31 August 2018
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6531812
25 August 2018
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6542988
24 August 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6522109
24 August 2018
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6524634
26 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6491321
24 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6399273
11 April 2018
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6380091
10 April 2018
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6388492
10 April 2018
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6388936
27 March 2018
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6390058
2 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6234231
12 May 2017
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6144604
11 May 2017
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6214797
9 May 2017
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6142015
24 April 2017
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6142964
18 April 2017
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6127499
16 April 2017
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6126384
16 April 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6126577
29 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6114642
6 March 2017
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6099644
7 January 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6069921
2 December 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6052431
30 November 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6049800
3 November 2016
Drydock Extension
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6036696
3 November 2016
In-Service Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6046737
24 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5839615
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 3 August 2026
Resolved
The Vessel Master made notication to [name withheld], that they vessel will be sailing short 01 AB. The Master has indicated that a qualified replacement AB is not expected to be available until the vessel's port of call in Gary, IN, on or about 09 AUG 2026. Accordingly, the vessel is permitted to proceed with one less AB for a period not to exceed seven (07) days, expiring on 09 AUG 2026. A three person watch system and work/rest hours must be maintained in accordance with applicable laws. The vessel/company shall make reasonable efforts at each ports to find a replacement. Vessel shall noptify the OCMIU, SECTOR DETROIT, of any changes.
705c (7 days)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 August 2026
Resolved 4 August 2026
Resolution: AB replaced
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 March 2026
Resolved
All inspected vessels are issued a COI indicating minimum crew complement; crew was missing 3rd mate needed to meet minimum manning.
46 CFR 15.105(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2026
Resolution: 3rd mate on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2026
Resolved
Each rescue boat must carry as appropriate equipment specified in this part; fire extinguisher had not been serviced annually.
46 CFR 199.725(b)(9)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 23 March 2026
Resolution: New extinguisher installed in rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2026
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket; (07) lifejackets were missing lights.
46 CFR 177.70(b)(4)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 23 March 2026
Resolution: Lights installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2026
No resolution recorded
Panelboard switch units shall be provided with a circuit directory card marked with the description of load served; rated load was not listed on any distribution panel directory. Cross reference available wiring references and add rated loads to each distribution panel directory throughout the vessel prior to next topside inspection.
46 CFR 111.40-1(h) (Old "J")
Action required: 705 - Other - as specified
Due 1 March 2027
01 - Certificates & Documentation › 013 - Documents › Tables of working hours
Issued 20 March 2026
No resolution recorded
In addition to prescribing watch requirements, 46 U.S.C. 8104 sets limitations on the working hours of credentialed officers and crew members, prescribes certain rest periods, and prohibits unnecessary work on Sundays and certain holidays when the vessel is in a safe harbor. It is the responsibility of the Master or Person in Charge to ensure that these limitations are met. The work-rest logs being maintained currently are not satisfactory to prove this to be the case as they do not record time worked during drills (e.g see rough log with work-rest hours on 29Dec2025). Begin logging drills as work in work-rest system vessel has opted to use; make available for inspector at next topside.
46 CFR 15.710
Action required: 705 - Other - as specified
Due 1 March 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2026
Resolved
Each auxiliary boiler must be available for examination at intervals specified by 46CFR61.05-10. Aux boiler SerNo CHI-7825 shall be tagged out until the following inspections and tests have been completed: Mountings Open/Removed, Fire and water side inspections, boiler safety valve SerNo BT08067 shall be adjusted to relieve at not more than 45 psi. Due prior to boiler operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 July 2026
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Anchoring devices
Issued 30 December 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Each vessel is to be provided with two bower anchors(stocklass. The starboard anchor windlass is not operational and the starboard anchor and chain were lost. Provide a repair proposal and make repairs to starboard windlass and install starboard anchor prior to departure from Superior, WI.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 March 2026
Resolution: Stern anchor relocated to bow.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Anchoring devices
Issued 30 December 2025
Resolved
Each vessel is to be provided with two bower anchors (stocklass). The port anchor windlass is not operational. Conduct operational test in presence of class surveyor and provide report to CG prior to departure from Gary, IN.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2025
Resolution: Operational test of port anchor conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 30 December 2025
Resolved
Vessel is required to have the manning as specified on the COI. Vessel does not currently meet the minimum manning specified on COI and is short 2 ABs. Update WQSB to document emergency resposibilities. Vessel shall return to required minimum manning prior to departure from Superior, WI.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 March 2026
Resolution: Vessel is maneed per COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2025
Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy of the equipment. Vessel reported issue with port inboard main engine that prevents the engine from providing thrust to the prop. Vessel is equipped with 2 mains per prop and has not lost ability to maneuver. Vessel authorized to transit to Conneaut, OH for cargo offload and then to Ashtabula, OH for winter layup. Vessel master must inform CG of any subsequent issues during transit that may reduce vessel's ability to maneuver. CG/ABS will verify full operation of port inboard engine prior to vessel breaking out for spring shipping season.
Action required: 705 - Other - as specified
Due 1 March 2025
Resolved 19 March 2025
Resolution: Conducted satisfactory tests on port inboard engine.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 28 June 2024
Resolved
Master made notification to [name withheld], of crew shortage due to consent based discharge of 3rd Mat Johnaton Deering, ref# 3860923, and 1st Assistant Engineer [name withheld], ref#173470. This consent based discharge is needed to return these crewmembers to their previously assigned vessel that was temporarily out of service for repairs. The vessel is authorized to sail with one less 3rd Mate and one less 1st Assistant Engineer fro 10 days until 8 July 2024. Three person watch system and work/rest hours must maintained in accordance with applicable laws. The vessel/company shall make reasonable efforts at each port to find a replacement. Prior to the expiration of the deficiency, the vessel/company is required to provide proof of adequate effort to find crew replacements.
Action required: 705 - Other - as specified
Due 8 July 2024
Resolved 26 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024
Resolved
The port SSDG was removed for a major overhaul and a temporary generator was installed on the port aft main deck. Make permanent repairs and install the port SSDG to its original location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2024
Resolved 14 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 April 2024
Resolved
In addition to the emergency power source required under part 112 of this chapter, each self-propelled vessel must have at least two electric generating sources. Vessels reported the port generator is not currently operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 April 2024
Resolved
In addition to the emergency power source required under part 112 of this chapter, each self-propelled vessel must have at least two electric generating sources. Vessels reported the port generator is not currently operational. Vessel is authorized one time transit from Duluth, MN to Gary, IN then to Sturgeon Bay, WI with the following stipulations. Vessel cannot transit during storm or gale warnings are in effect by National Weather Service. Vessel must contact each Captain of the Port Zone prior to entering to inform them of entry and report if any new failures occur. Assist Tugs shall be used in accordance with voyage plan in addition to having an assist tug for the Straits of Mackinac, and informing Sector Northern Great Lakes VTS and Command Center the specific assist tugs being used for transit in the Straits and [name withheld] System. Notification must be made prior to entering Gros Cap. For Sector Northern Great Lakes area transit, tugs can depart once the vessel is safely west of the Mackinac bridge. Vessel must submit temporary repair plan for review and acceptance by local OCMI in Sturgeon Bay, WI. The port generator shall be repaired in 30 days from this 835V issuance date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2024
Resolved 10 April 2024
Resolution: A temp generator was placed on the main deck to replace the port SSDG. The ship now has two electric generating sources.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 March 2024
Resolved
Each cargo vessel must carry a lifeboat with aggregate capacity to accommodate the the total number of persons on board. The current lifeboat has insets at the bow and stern, along the port side. While the lifeboat sits with an even keel, and is not taking on water while deployed, the sharpness of the insets bring the integrity of the hull into question. Vessel is to replace the lifeboat in accordance with 46 CFR 160.156 and installed in accordance with 46 CFR Subchapter W, by next Winter Lay Up to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2025
Resolved 21 March 2025
Resolution: New CG approved rescue boat installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 January 2024
Resolved
EACH VESSEL MUST HAVE AN ILLUMINATED MAGNETIC STEERING COMPASS, MOUNTED IN A BINNACLE, THAT CAN BE READ AT THE STEERING STAND.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2024
Resolved 19 March 2024
Resolution: COMPASS WAS ADJUSTED AND READING ACCURATELY. THE DEFICIENCY IS CLEARED.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 January 2024
Resolved
EACH VESSEL MUST HAVE A CURRENT MAGNETIC COMPASS DEVIATION TABLE IN THE WHEELHOUSE.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 27 March 2024
Resolution: Received a copy of the deviation table, and the deficiency was cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 September 2023
Resolved
The main steering gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. During transit in the St. Marys River the rudder was stuck at Starboard 25 degrees for 50 seconds rendering the primary steerage of the ship inoperable. Conduct testing to diagnose this anomaly at anchorage and before transiting through the St. Marys river. Provide attestation to [name withheld] identifying Master's confidence in a safe voyage with mitigating steps if there is a re-occurrence. Also provide technician report prior to departing next port of call.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2023
Resolved 25 September 2023
Resolution: Techinician and Captain attested to proper operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 September 2023
Resolved
Main propulsion machinery must be provided with automatic shut-off controls. Vessel has a faulty fuel oil pressure switch that caused the engine to de-clutch when operating near the Sault locks on 2SEP23. Vessel must make permanent repairs to the faulty switch prior to departing Two Harbors MN.
46CFR90.20-1
46CFR58.05-10
Action required: 705 - Other - as specified
Due 3 September 2023
Resolved 4 September 2023
Resolution: Vessel replaced the faulty sensor.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 May 2023
Resolved
Vessel master reported an issue with their outboard port steering pump, which caused it to not be operational. Vessel crew shall trouble-shoot the system to identify the causal factor(s) for the steering pump to become not operational and conduct repairs and test steering using the outboard port steering pump to the satisfaction of the attending Coast Guard Marine Inspector or Class Surveyor prior to departing Duluth, MN.
Vessel master shall make arrangements to have an appropriate tug escort from Mud Lake to Gros Cap (St. Marys River system) and Duluth/Superior Harbor Entrance.
46 CFR 91.25-35(a)
46 CFR 61.20-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2023
Resolution: MSU Duluth cleared the deficiency on 21 May 2023. MISLE Activity #7693177.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2022
Resolved
Vessel experienced vibration from propeller associated equipment and has determined that it is most likely caused by ice damage. Vessel is permitted to proceed to Duluth, MN at reduced speed and appropriate weather conditions to effect immediate repairs to the satisfaction of Class or attending Coast Guard Marine Inspector. 46CFR58.05-1(a)
Action required: 15 - Rectify deficiencies by next port
Resolved 17 April 2022
Resolution: Issue caused by cable wrapped around port propeller. Cable removed; no further vibration or damage noted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 January 2022
Resolved
Due to mooring arrangements the required 1.1 overload weight test could not be completed. The life boat is to be tested IAW 46 CFR 199.190(i) due to the renewal of the COI. This test is to be followed by satisfactory demonstration of a person overboard drill. All to the satisfaction of an attending CG Marine Inspector.
46CFR199.190
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2023
Resolved 21 May 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 January 2022
Resolved
On B deck above the breaker panels at the door that leads to A deck there is an approved Muli-cable transit system to ensure structural fire adequacy of the overhead. Within this MCT there are four cables that enter a single MCT block. This MCT is to be corrected with the installation of an approved MCT system rated for the fire rating of the overhead and installed IAW the manufacturer's manual. (multiple cables may not penetrate a single block). To be inspected and air tested to the satisfaction of an attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 22 April 2023
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 18 August 2021
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under § 164.35(a), a second marine radar system that operates independently of the first. Vessel's secondary radar system is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2021
Resolved 18 August 2021
Resolution: Received email confirmation and the technician report from the vessel master that repairs had been carried out and radar was in good working order.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 December 2020
Resolved
The installed light bulb on the magnetic compass is inoperable and needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 20 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2020
Resolved
Aux. Boiler #-S4317, has a chunk of insulation missing on the fire door, that must be repaired with approved material, prior to being used.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2021
Resolved 4 May 2021
Resolution: Reviewed product information and photographs of the repaired area on the boiler doors. Repairs are acceptable and the deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 17 December 2020
Resolved
Wooden blocks on the davit, that hold the lifeboat in place while stowed, must be replaced due to rotted condition. Must be completed no later than 01JUN2021.
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 19 April 2021
Resolution: Photographs of newly installed wooden blocks sent to MSU Cleveland. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 August 2020
Resolved
The steering is operating at reduced capability. The steering system is equipped with two hydraulic pumps per rudder. Only one steering pump per rudder can be energized due to an undiagnosed fault. The system fault shall be diagnosed, repaired and satisfactorily tested prior to departing next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Due 20 August 2020
Resolved 17 August 2020
Resolution: Recieved Statement from Master and Chief Engineer attesting to proper operation after replacing two blown fuses caused by a loose wire.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2020
Resolved
Did not conduct drills to maintain social distancing practices (COVID-19) during inspection. Drills (Fire and abandon ship) to be conducted in the presence of Coast Guard inspectors at a future date.
Action required: 705 - Other - as specified
Due 2 June 2020
Resolved 27 April 2020
Resolution: Drills were conducted and photos were sent to MSU Toledo inspectors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2019
Resolved
Vessel reports discovering a loss of 3-4" of water in jacket- water head tank, and intrusion of water into the oil of the PIME. As a result, the PIME has been shutdown and taken out of service. Vessel authorized to load cargo in Superior, WI and subsequently transit to Conneaut, OH for offloading, and PIME repairs. Make complete repairs to PIME prior to departure from Conneaut, OH and provide service technician's report, and a statement from the C/E, certifying restoration of full engine functionality to MSU Cleveland or MSU Duluth.
Action required: 15 - Rectify deficiencies by next port
Due 10 January 2020
Resolved 3 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2019
Resolved
Port rudder failed to respond while on port pumps. Master switched to stbd pumps and regained full functionality. Provide tech service report regarding intermittent mode failure and cause and make permanent repairs to original condiiont prior to operation on port pumps.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 6 May 2019
Resolved 7 May 2019
Resolution: Sperry Tech attended vessel and found the system to be operating properly and could not ascertain the cause of the failure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 March 2019
Resolved
Repair/replace bearing on stbd inline generator
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 8 October 2019
Resolution: generator removed, re-built, re-installed, with all operational testing found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 March 2019
Resolved
Vessel was unable to lower the open Life Boat, as well as get the life boat underway during the Annual COI inspection due to location at the dock. Vessel is required to lower the life boat into the water and have crew maneuver the life boat in the water in the next 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 18 April 2019
Resolution: Vessel launched lifeboat while moored in Two Harbors, MN on 17APR19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2018
Resolved
One of the port propeller flukes was found to have significant inter-granular corrosion during inspection. The fluke number is HT79GA. A replacement fluke is not immediately available and must be ordered. Fluke # HT79GA may remain in service until a proper replacement in kind is available. In no case may the damaged fluke remain in service past 31JAN19. The fluke must be permanently repaired IAW ABS rules or replaced in kind by this date. Any adverse change in condition to the port side propulsion system or failures are to be immediately reported to the local [name withheld] or permanent repair to be verified by an attending CG Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2019
Resolved 10 September 2019
Resolution: Received Class Survey Report Clearing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 August 2018
Resolved
Due to loss of port rudder, vessel is required to discharge current cargo and make permanent repairs to rudder and damaged port propeller. Vessel is allowed to transit to Indiana Harbor to off load cargo and then proceed to Sturgeon Bay for repairs. During transit vessel is required to make safety rounds to ensure that there is no water ingress in spaces that could be affected by the loss of the port rudder at intervals of not more than two (2) hours
During transit to Indiana Harbor, vessel is required to notify each USCG Sector as the vessel enters each zone and ensure that there are no further requirements for safe transit (ie. tug assist).
When transiting the Sector Sault Ste. [name withheld] zone a tug assist will be required and the vessel will only be allowed to transit the locks during daylight hours.
46 CFR 58.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2018
Resolution: Repairs with Finial tests verified on 05SEP2018
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 10 April 2018
Resolved
Helmsman must remain on watch at all times until autopilot failure(loss of CDU) alarm is installed and tested to the satisfaction of the attending CG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 24 April 2018
Resolution: Examined autopilot failure alarm installation and witnessed satisfactory test at Silver Bay, MN.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2017
Resolved
Repair/replace affected areas damaged after grounding on the Conneaut Harbor breakwall. Areas to be identified after dry-docking in Erie, PA.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 31 May 2017
Resolution: Satisfactory tests and visual inspection conducted by CG MIs and Class. Deficiency is cleared.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 21 April 2017
Resolved
Submit revisions to the Design Verification Test Procedure (DVTP’s) for the Steering Stand to address all comments in the USCG Marine Safety Center letter E2-1701283 dated 18 April, 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 31 May 2017
Resolution: DVTPs have been submitted for review to MSC. Cleared 835.
Engineering › Steering Gear System › Actuator
Issued 21 April 2017
Resolved
After the USCG Marine Safety Center considers the Steering Stand Design Verification Test Procedure (DVTP’s) are satisfactory for shipboard testing, conduct shipboard testing in the presence of the Cognizant OCMI Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 10 April 2018
Resolution: Conducted shipboard testing as required.
Engineering › Thrusters › Seal
Issued 16 April 2017
Resolved
Determine source of hydraulic fluid leak on stern thruster/stern tube. Provide report to cognizant OCMI attesting to repair and satisfactory operation of stern thruster. Stern thruster is to remain secured from operation for remainder of voyage to Duluth/Superior.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 18 April 2017
Resolution: Stbd CPP hub found leaking at end plate jacking bolt holes. Sealed up with 5/8" bolts and comprssion washers by TL services. Tested and corrected.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 March 2017
Resolved
A helmsman shall remain on watch at the main steering console AT ALL TIMES while underway until shipboard testing of the Steering Stand Design Verification Test Procedures (DVTP’s) are verified to the satisfaction of attending CG Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 10 April 2018
Resolution: Issued updated 835 due to new test procedure results.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 March 2017
Resolved
When maneuvering or while navigating the river systems the Engine Control
Room shall be manned with one licensed engineer. Another crew member that is
knowledgeable on the operation of the steering system shall be immediately
available on request of the licensed engineer on watch until shipboard
testing of the Steering Stand Design Verification Test Procedures (DVTP's)
are verified by a CG MI
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 10 April 2018
Resolution: Required operation in "both" steering systems when navigating in restricted maneuverability situations as a condition on COI.
Operations/Management › Navigation Safety › Assist Tug(s)
Issued 24 March 2017
Resolved
Vessels Bow Thruster is not operational. Until corrected, to the satisfaction of the cognizant OCMI, when operating in restrictive water (Sturgeon Bay, in & out of Soo Locks, & Duluth Harbor) vessel must have tug assistance.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 31 March 2017
Resolution: Witnessed operational test of bow thruster in all modes after seals were replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 March 2017
Resolved
Vessel has uncompleted repairs to watertight bulkheads as follows: Watertight bulkhead at fr 90 between cargo holds 5&6, watertight bulkhead at fr 36 between cargo holds 2 & 3, and watertight bulkhead at fr 21 between cargo holds 1 & 2. Details of required repairs were issued via hard copy 835 which is scanned into activity and listed in narrative portion dated 20MAR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 31 March 2017
Resolution: Examined all steel work for watertight bulkhead inserts between cargo holds 1&2, 3&4 and 5&6. All sat.
Lifesaving › Lifeboat › Seating
Issued 2 December 2016
Resolved
Make permanent repairs to lifeboat: Replace deteriorated internal wooden components to include: port fore plywood walkway/seating; port fore outboard 2" X 10" bottom plank; and starboard aft outboard 2" X 10" bottom plank, to the satisfaction of the cognizant OCMI.
Condition: Improper/Lack of Maintenance
Due 2 January 2017
Resolved 23 December 2016
Resolution: Repaired.
Deck/Cargo › Ballast › Tank
Issued 29 November 2016
Resolved
Repair fracture in the #7 Starboard Ballast tank that is leaking into the conveyor tunnel prior to departure from port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 29 November 2016
Resolution: Attending Marine Inspector verified that temporary repair was completed and leak properly sealed. Permanent repair required during winter lay-up.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 November 2016
Resolved
Conduct Man Overboard drill to satisfaction of the attending Marine Inspector and conduct a satisfactory test of the lifeboat hook release mechanism.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 2 December 2016
Resolution: Witnessed proper launch and recovery of lifeboat.