MAURY USCG vessel records
← All vessels

KIRBY 10510

Built
1991
Last inspected
10 March 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 March 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 35 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

368960
Flag
UNITED STATES
Maury page id
psix-368960

Documentation record

Tonnage as PSIX records it705 - Regulatory (Subpart C or D), Gross Ton
705 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 59 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PALO DURO Towing Vessel · MISLE 194419 · 30 October 2012 · activity 4475313KIRBY 10554 Tank Barge · MISLE 477577 · 30 October 2012 · activity 4475313OHIO RIVER PRIDE Towing Vessel · MISLE 195230 · 10 March 1998 · activity 99059

Inspection history · 59

10 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8329196
17 December 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8284766
4 April 2025 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8112387
30 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8012033
2 October 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7802188
24 August 2023 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7775583
6 April 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7425894
28 October 2021 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7341125
7 July 2020 Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · COI Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6999578
17 January 2019 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6611785
7 September 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6287761
6 December 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6053614
14 October 2016 Drydock Exam · MTSA Verification · Examination of Repairs · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6020743
3 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5966986
23 March 2016 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5838058
2 July 2015 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5870392
31 July 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5007487
12 August 2013 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4682462
30 October 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4475313
1 September 2011 MTSA Verification · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4130108
29 October 2010 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3880495
10 May 2010 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3787703
1 September 2009 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3582450
28 May 2009 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3540444
17 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3274540
11 October 2007 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3077436
19 July 2007 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3026687
5 July 2006 MTSA Verification · COI Inspection · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2701921
12 January 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2565487
23 May 2005 COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2367127
18 April 2005 MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2336479
13 April 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2071539
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1988307
29 April 2003 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1826823
22 April 2002 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1624931
4 October 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 529617
31 July 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1069446
30 July 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070030
9 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412339
10 July 2000 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 819864
27 July 1999 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 773653
26 August 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 797462
10 March 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 99059
10 December 1997 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 780643
25 October 1996 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 859170
8 December 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404051
20 November 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1377557
6 September 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 530160
17 November 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432850
23 November 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1465123
24 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 837675
11 March 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 484504
6 January 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961680
13 November 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962713
29 July 1992 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254772
4 June 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 958691
2 April 1992 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 962461
14 March 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956862
27 November 1991 Hull Examination · Initial Certification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 937303

Deficiency record · 12

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 September 2024 Resolved
For cargoes that have toxic properties, listed in 46 CFR Table 151.05 with the “Special requirements” column referring to 46 CFR 151.50-5, an overfill alarm and shutdown system that meet the requirements of 46 CFR 39.2007(a), 39.2009(a), or 39.2009(b) must be used for primary overfill protection. Alarm was not functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
Resolution: Replaced battery
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 September 2024 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens. Inboard screens were found to be faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
Resolution: painted flat black
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 September 2024 Resolved
Each hose must be marked with one of the following: (1) The name of each product for which the hose may be used; or (2) For oil products, the words “OIL SERVICE” Each hose also must be marked with the following: (1) Maximum allowable working pressure; (3)Date of the latest test required by 33 CFR 156.170. Discharge piping stencil was missing maximum allowable working pressure and the name of the product which the piping may be used.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
Resolution: Hoses properly marked
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2024 Resolved
At each inspection for certification, periodic inspection, and at such other times as considered necessary, the inspector must determine that all fire extinguishing equipment is in suitable condition. Starboard fire extinguisher indicator was in the red and signs of corrosion on the neck and bottom.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
Resolution: Replaced fire Ext
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2024 Resolved
Cargo tanks in which Grade D or E liquids only are to be transported shall be fitted with gooseneck vents and flame screens. 3 goosenecks on the port side was missing flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 13 November 2024
Resolution: Replaced all flame screens
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 4 November 2016 Resolved
Relief valves are required at pump discharge except for centrifugal pumps so designed and applied that a pressure in excess of the MAWP for the system cannot be developed. Prior to cargo discharge operations, vessel shall provide documentation attesting that the centrifugal pump cannot exceed MAWP of the cargo pipeline.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 10 November 2016
Resolution: Visted vessel and verified that a new cargo pump relief valve was installed and tested in accordance with 46 CFR 56.07-10(b).
Deck/Cargo
Issued 20 November 1995 Resolved
Make cargo tank hatch and ullage opening flame screens available for Coast Guard inspection prior to loading cargo, but not later than compliance date.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Deck/Cargo
Issued 20 November 1995 Resolved
Make vapor control system piping available for Coast Guard inspection priorto loading cargo, but not later than the compliance date.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Deck/Cargo
Issued 20 November 1995 Resolved
Perform cargo hi-level alarm operational test prior to loading cargo, but not later than the compliance date.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Documentation
Issued 27 November 1991 Resolved
PROVIDE APPROVED CARGO TRANSFER PROCEDURES INCLUDING VAPOR RECOVERY SYSTEM PROCEDURES AS REQUIRED. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO PLACING BARGE IN SERVICE AND IN NO CASELATER THAN THE ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Deck/Cargo
Issued 27 November 1991 Resolved
PROVIDE PROOF THAT PUMP ENGINE FUEL TANK COMPLIES WITH APPLICABLE REGULATIONS (46 CFR 58.50-10(A)(4)(i) THROUGH (iii)) AND IS APPROVED BY _x001C_ G-MSC.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Engineering
Issued 27 November 1991 Resolved
INSULATE ABOVE DECK STEAM PIPING AS REQUIRED TO PROTECT AGAINST PERSONNEL INJURY. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO PLACING BARGE IN SERVICE AND IN NO CASE LATER THAN THE ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991

Ownership record