Inspection record

Last inspected 21 January 2026
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 22 calendar years (2002–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9269752
WDB6235
Flag
UNITED STATES
Tonnage
15852 - Dead Weight, Ton 7159 - Convention (Subpart B), Gross Ton 6774 - Regulatory (Subpart C or D), Gross Ton 4572 - Convention (Subpart B), Net Ton 6774 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-37528
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 56

21 January 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299238
2 December 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8032338
5 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8029428
21 February 2024 MTSA/ISPS Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7868021
2 April 2023 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7694127
4 January 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7617034
2 December 2022 MTSA Verification · MARPOL Annex II Examination · COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602250
29 November 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601447
17 August 2022 Construction Oversight · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7536458
18 August 2021 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7290052
11 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7194143
29 November 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7104134
20 August 2020 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7038213
20 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7039319
20 August 2020 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7072614
19 June 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6981050
29 May 2020 COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Cargo Tank Internal · MTSA Verification · Examination of Repairs · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6939420
8 January 2020 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6885488
6 September 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6261001
12 September 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5998960
19 July 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5946320
6 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5792691
24 September 2015 MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5731583
21 September 2015 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5725502
27 July 2015 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5197391
26 September 2014 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4994621
24 September 2014 MTSA Verification · MARPOL Annex II Examination · MARPOL Annex VI Survey · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4991079
14 March 2014 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4816114
24 October 2013 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4747973
9 August 2013 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4677705
30 July 2012 Internal Structural Exam · Drydock Exam · MARPOL Annex I Examination · COI Inspection · Cargo Tank Internal · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4396779
14 November 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4189283
7 October 2011 Annual Inspection · MTSA Verification · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4162952
7 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3868484
8 September 2010 MARPOL Annex II Examination · Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3845516
26 July 2010 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3806473
2 June 2009 MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3493312
14 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3474647
14 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3474926
30 October 2008 MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3354137
10 October 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3349285
18 September 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3327166
30 August 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3043707
13 July 2007 Hull Examination · Internal Structural Exam · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2992677
25 August 2006 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2759625
18 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2627330
27 July 2005 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2441501
21 July 2005 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2434363
18 October 2004 MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2222853
23 August 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2174528
22 May 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2074823
12 February 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2005423
6 October 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1922018
20 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1797470
15 April 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1860574
23 September 2002 Initial Certification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1636385

Deficiency record · 29

01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 February 2024 Resolved
Load line marks to indicate the maximum amidship's draft to which a vessel can be lawfully submerged, in the various circumstances and seasons, shall be permanently marked on each side of the vessel in the form, manner, and location as required by this subchapter. Load line marks were not permanently affixed on the hull. The vessel will be permitted to maintain cargo operations under a Lakes Bays and Sounds route until repairs are complete. 46 CFR 42.07-5(a) (705c)
Action required: 705 - Other - as specified
Due 23 February 2024
Resolved 2 December 2024
Resolution: After closer inspection, vessel's load line was permanently marked with indentations. Recommend raised welding due to paint filling in the indentations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2024 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. The forward cargo tank trunk has a cracked weld on the gusset between trunk and anchor winch. Repair prior to next dry dock credit. 46 CFR 32.60-1 (705c)
Action required: 705 - Other - as specified
Resolved 2 December 2024
Resolution: Cracked weld on the gusset between trunk and anchor winch was repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 8 December 2022 Resolved
To embark on international voyages, a vessel must have a valid IAPP Certificate. Provide the SOx & NOx technical files for the hydraulic pump engine so that a correct IAPP Certificate can be issued, prior to embarking on an international voyage.
Action required: 705 - Other - as specified
Resolved 8 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 2 December 2022 Resolved
No extensive alterations involving machinery shall be made without the approval of the Commandant. Alterations shall be submitted to the OCMI for approval. Submit copies of EPA certificates, engine technical data attesting to weight and power rating, and technicians report attesting to installation. Required for cargo pump engines and hydraulic pump engine. Required prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 December 2022 Resolved
All access openings shall be weathertight when closed. Watertight doors on stbd cargo pump room and ballast rooms on aft deck have seized dog bones preventing a good seal of the door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2022 Resolved
Electrical installations must be installed and ensure the protection of crew. Electrical junction box in port cargo pump room in overhead is missing the cover. Install cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2022 Resolved
Approved portable fire extinguishers must be installed in accordance with table 34.50-10(a). 02 40B portable fire extinguishers are required in the port cargo pump,hydraulic pump, ballast generator engine room. 1 required at each exit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 December 2022
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 2 December 2022 Resolved
Provide technical data for ballast system pressure vessel receiver. Include data plate, approval number, serial number, and MAWP.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 December 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 August 2020 Resolved
Make permanent repairs to the pin hole in aft peak void stbd side (6' above waterline). Vessel authorized to transit to Sector New York zone for repairs; to me made to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 21 August 2020
Resolution: Sector Ny Duty MI received pictures of repair and ABS class report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 May 2020 Resolved
No stowage position for a survival craft on a tank vessel may be located on or above a cargo tank, slop tank or other tank containing explosive or hazardous liquids. Currently, the barges liferaft is located centerline directly above cargo tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 2 July 2020
Resolution: At request of owner, removed Conditional Occupancy authorization from COI.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 29 May 2020 Resolved
One emergency outfit is required for all unmanned tank barges having cargo tanks which exceed 15 feet in depth measured from the deck to the lowest point at which cargo is carried. Barge did not have the required emergency suit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 20 July 2020
Resolution: At request of owner, removed Conditional Occupancy authorization from COI.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 29 May 2020 Resolved
The high / overfill alarm required by the paragraphs (c) and (d) must be identified with a legend "HIGH-LEVEL ALARM" and "TANK OVERFILL ALARM". The high and overfill alarms were not labeled.
Action required: 10 - Deficiency Rectified
Due 29 May 2020
Resolved 29 May 2020
Resolution: Gulf Copper shipyard was able to install the correct legends prior to completion of the inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 September 2017 Resolved
Prior to conducting cargo operations, Complete new COI inspection, Credit Drydock, & Internal Structural Exams.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2020
Resolution: Completed all outstanding inspections.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 15 August 2013 Resolved
Cargo Pump Engine #2 120 volt panel is indicating a ground fault located in the liquid overfill protection alarm system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2013
Resolution: Company electrician indicated ground fault was coming from the high/overfill junction box. Loose wire connections were secured back into place which cleared the ground fault.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 August 2013 Resolved
Cargo Pump Engine #1 gas tight integrity is compromised with two holes in the bulkhead located in the hazardous zone area.
Due 29 August 2013
Resolved 15 August 2013
Resolution: Vessel barge captain pluged bolt fitting into holes, to avoid cargo vapors from entering into the space.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 15 August 2013 Resolved
Procedures and Arrangements Manual is not onboard the vessel.
Due 29 August 2013
Resolved 15 August 2013
Resolution: Company printed out the Procedures and Arrangments Manual and delivered it to the vessel.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 15 August 2013 Resolved
Vessel does not have a approved Volatile Organic Compound Management Plan (VOC) onboard. Vessel is prohibited from carrying crude oil on a international voyage until plan is approved and onboard. MARPOL ANNEX VI Reg. 15
Due 15 September 2013
Resolved 6 September 2013
Resolution: Received email from MSC with VOC management plan approval letter dated 06SEP2013.
Accommodation/Occupational Safety › Potable Water System › General
Issued 15 August 2013 Resolved
Vessel does not have installed mechanical eyewash stations and showers located on the weather deck.
Due 15 September 2013
Resolved 3 September 2013
Resolution: Witness test proper operation of the new installed mechanical eyewash stations and showers located on the weather deck. Test satisfactory.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 15 August 2013 Resolved
Vessel liquid overfill protection to the vapor control system power failure alarm (blue light) is inoperable.
Due 29 August 2013
Resolved 3 September 2013
Resolution: Properly tested the liquid overfill protection to the vapor control system power failure alarm (blue light), operational test satisfactory.
Engineering › Lubricating Oil Service System › Valve, Control
Issued 30 July 2012 Resolved
Vessel can't demonstrate low lube oil shutdown/alarm on gen set, must prove proper operation to CGMI.
Due 12 September 2012
Resolved 31 August 2012
Resolution: Proved proper operation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 30 July 2012 Resolved
Vessels cargo hose's on deck are not properly marked, must mark proper in accordance with CFR and show CGMI.
Due 12 September 2012
Resolved 31 August 2012
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 30 July 2012 Resolved
Vessel does not have a SOPEP manual on board, must provide and keep on board.
Due 12 September 2012
Resolved 31 August 2012
Resolution: Mannual on board
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 30 July 2012 Resolved
Vessel must provide proper bunker notes, label sample bottles, and conduct training with crew for proper operation and logging.
Due 12 September 2012
Resolved 31 August 2012
Resolution: Provided proper log and training of crew.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 7 October 2011 Resolved
High level and loss of power alarm visual indicator was INOP. Correct Prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2011
Resolution: ABS provided class report stating high level and loss op power alarms are properly working.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2010 Resolved
Replace guard for #2 cargo pump engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 10 September 2010
Resolution: Received photograph for guard installation.
Personnel › Training › Tank Barge Dangerous Liquids
Issued 8 September 2010 Resolved
Provide training for Barge's PIC/tankerman on MARPOL ANNEXII responsibilities (P&A Manual).
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 10 September 2010
Resolution: Received training log for barge personnel.
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 8 September 2010 Resolved
Vessel is not in compliance with MARPOL ANNEX VI. Vessel is restricted to domestic service until an initial IAPP survey is conducted.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 7 October 2011
Resolution: MI conducted MARPOL Annex VI survey. Vessel is in compliance with regualtions. Sector New York will issue IAPP cert.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 September 2010 Resolved
Provide evidence for emergency training and drills log IAW 46CFR97.355.
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 10 September 2010
Resolution: Received copies of training and drills.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 13 July 2007 Resolved
Provide tech report accreting to proper operation of high level and overfill alarms on the 3P and 5P tanks. Do not use tanks 3P and 5P until item cleared.
Due 8 September 2007
Resolved 10 August 2007
Resolution: Tech report received.