Inspection history · 48
22 February 2023
Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7639279
8 February 2023
Permit to Proceed
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7634216
7 November 2022
Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7592209
3 October 2022
Administrative Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7575802
20 September 2022
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7563188
18 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7562715
16 September 2022
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7567111
14 June 2022
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7477113
20 December 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7368454
15 December 2020
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7112284
27 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961834
18 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6837129
4 June 2019
Re-Inspection · Deficiency Check · MTSA/ISPS Verification · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6745065
14 August 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5216077
4 December 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5034078
4 December 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5034485
3 November 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5021115
18 February 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4809019
20 November 2013
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4756374
20 November 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4756694
18 July 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4388850
29 February 2012
Administrative Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4253809
29 February 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4257540
13 February 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4243660
13 February 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4244689
14 November 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4189283
21 September 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4150970
11 May 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3581525
2 July 2008
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3204357
1 March 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3156350
11 August 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3027447
26 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2879871
1 November 2006
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2812039
20 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2632482
28 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2611948
17 April 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2336215
15 December 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2259935
20 October 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2225295
12 October 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2219021
14 September 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2206633
21 June 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2106017
12 May 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2092046
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979686
1 July 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1658506
17 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 730411
11 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 187668
21 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762463
16 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 207332
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
The Ultrasonic Testing report, 5702232, reflects the following areas which are wasted in excess of the allowable limits: (Page 4) Position 2, 3, 5, and 6. (Page 6) Position 1 thru 7 and 17. (Page 7) Position 1, 2, and 3. (Page 10) Position 2, 4, 12, and 13. (Page 12) Position 1. (Page 14) Position 1, 6, and holed area. (Page 15) Position 4. (Page 17) Position 3. (Page 23) Position 25. (Page 27) Position 4, 6, 8, and 12. (Page 30) Position 1, and 3 thru 5.
Provide repair proposal to crop and renew identified areas to original.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Fuel piping has worn sections due to rubbing of the fuel shut-off reach rods.
Crop and renew.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
#2 ballast water tank portside: identified overboard piping with two check valves in-line, piping between flange coupling and check valves is severely corroded, location outer shell most aft.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
#2 ballast water tank portside: conduct gauging in presence of CG Marine Inspector 1' from forward bulkhead aft and up 1' on the internal bulkhead, location most inboard and forward bay.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #2 Ballast tank:
MI identified holed and corroded bottom longitudinal in the #2 Starboard void approx. (marked with orange spray paint).
Crop/Renew.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #3 Ballast Tank:
MI identified deck longitudinal in bay 1 replaced not in kind to original scantling. Crop/renew.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #3 Ballast Tank:
MI identified cracked weld approx. 12" long in bay #1 IWO centerline bulkhead and bottom longitudinal. Re-weld.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #3 Ballast Tank:
MI identified three (03) deck longitudinals IWO transverse frame with cracked welds. Re-weld.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #4 Ballast Tank:
MI identified two (02) transverse deck stiffeners wasted and corroded. Crop/renew.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #4 Ballast Tank:
Crop/renew vertical stiffener IWO man hole and piping bracket.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #5:
MI identified cracked weld and hole on vertical stiffener in outboard bay, IWO aft bulkhead. Re-weld.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #5 Ballast Tank:
MI identified cracked weld on deck longitudinal in inboard bay. Re-weld.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times.
Starboard #5 Ballast Tank:
MI identified wasted deck long. in bay #1. Crop/renew.
46 CFR 137.120(a)
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Prior to operations. Vessel surrendered its COI per the owners request.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 January 2023
No resolution recorded
Fore Peak: 03 bottom most transverse/longitudinal stiffeners on both sides of the vessel (port and starboard). Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 January 2023
No resolution recorded
4s: Overhead stringers and transverse/longitudinal stiffeners as marked. Forward bulkhead area as marked/noted on UT report. Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 January 2023
No resolution recorded
4p: Aft-most transverse frame on bottom of tank. Overhead stringers and transverse/longitudinal stiffeners as marked. Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 January 2023
No resolution recorded
5s: Overhead stringers in both inboard/outboard baffled compartments as marked and transverse/longitudinal stiffeners as marked. Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 January 2023
No resolution recorded
5p: Overhead stringers and transverse/longitudinal stiffeners as marked. Inboard compartment-Port Bulkhead as marked. Prior to credit dry dock.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2023
No resolution recorded
A towing vessel must undergo an annual inspection within three months before or after the COI Anniversary date. Vessel is outside the 90 day window for completing its annual inspection. Vessel must complete its annual inspection prior to commercial operations. 46 CFR 137.200
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 January 2023
Resolved
Provide scantlings or alternative proof of original thickness of hull material. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 31 January 2023
Resolution: Vessel rep provided scantlings.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 23 January 2023
Resolved
Thoroughly descale and clean the following spaces for further inspection: Fwd peak space, 4 p/s, 5 p/s. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 31 January 2023
Resolution: Designated tanks were throughly cleaned for inspection
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 January 2023
Resolved
Prep fwd bulkheads in p/s freshwater tanks for further inspection of pitting. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 31 January 2023
Resolution: Bulkhead was prepped for UT shots
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 January 2023
No resolution recorded
Replace all gaskets on voids and ballast tanks. Prior to credit dry dock.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 January 2023
No resolution recorded
Prior to conducting any steel repairs, a repair plan must be submitted to be reviewed to include all materials, welder performance qualifications, and welding procedures. Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 January 2023
No resolution recorded
The following locations have been marked for Crop and Renew:
4s: Middle Bay, 02 overhead transverse stiffeners as marked. Outside Bay, 02 overhead transverse stiffeners as marked. Inside Bay, 01 overhead transverse stiffeners as marked.
4p: Middle Bay, 01 overhead transverse stiffeners as marked. Inside Bay, 01 overhead transverse stiffeners as marked.
Prior to credit dry dock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2022
No resolution recorded
Vessel had pin hole in hull port side forward near draft marks. Conduct UT shots around welded pin hole to determine metal thickness. Provide report to us on findings. If vessel crew is conducting UT shots, a Marine Inspector needs to be present. 46 CFR 137.120(a). Prior to credit dry dock
Vessel completed an unauthorized clad weld with no oversight on pin hole in fwd peak space (port side). Area was was hose tested/NDT with no intrusion of water. Vessel is to make permanent repairs prior to credit dry dock.
Action required: 705 - Other - as specified
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2022
Resolved
Both propellers have not been inspected as required by ABS report. Submit report, post loss of tow line, from ABS, attesting to the inspection of both propellers.137.330(a)(4). prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 3 February 2023
Resolution: ABS report recieved attesting the NDT of the props and hub. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 7 November 2022
Resolved
Prior to inspection of ballast and void tanks, a Marine Chemist needs to issue a certificate attesting that the tanks are Safe for Workers. Provide Marine Chemist certificate after scraping tanks, removing mud and pumping residual water off prior to scheduling Internal Structural Exam. Once a Marine Chemist Certificate is issued, the atmosphere of the tanks SHALL NOT be changed. 29 CFR 1915.12. prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 23 January 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 September 2022
No resolution recorded
A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination (DD/ISE) at least twice every 5 years, with not more than 36 months between examinations. Towing Vessel [name withheld] received its COI on 13Sep2019 and was due for DD/ISE by 30Sep2022. Make the vessel available for a DD/ISE prior to operation as a towing vessel. 46 CFR 137.300
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2022
Resolved
Electrical equipment must be provided with circuit isolation. Cable between 2nd deck generator and the main switchboard has no breaker or isolation switch. 46 CFR 143.250 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: A breaker was added in the shore tie panel on the upper deck of the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022
Resolved
All seals and gaskets must be properly maintained to prevent leaks combustible liquid into the machinery space. #1 and #2 Fuel oil transfer pumps are badly leaking diesel into the bilge. Repair pumps to prevent leaks. 46 CFR 143.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: No longer leaking. Crew says they replaced shaft seal. 2nd time this def has been issued in 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 September 2022
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Crew was unable to gain suction with either bilge pump. Demonstrate proper operation of bilge dewatering system. 46 CFR 143.275
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: Satisfactorily tested vessel electric submersible bilge pump.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 27 September 2022
Resolved
Any towing vessel must identify the duties of each person on board during an emergency, including: (1) Responding to fires and flooding. Vessel was unable to demonstrate ability to dewater bilge spaces. Vessel crew must demonstrate proficiency with shipboard emergency operations. 46 CFR 140.405(b)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: Crew showed some competency on 03OCT. Will be checked at upcoming in service inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2022
Resolved
New electrical installations that are not replacements in kind must comply with the requirements of 46 CFR 143 subpart C. A new generator was installed on the vessel 2nd deck due to the original port generator being inoperable. This new generator must be made to meet all applicable requirements listed in 46 CFR 143.555 and 46 CFR 143.575. 46 CFR 143.205(d) prior to commercial ops.
Action required: 705 - Other - as specified
Resolved 23 January 2023
Resolution: Generator has been taken out of service and not opertional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2022
Resolved
All seals and gaskets must be properly maintained to prevent leaks of combustible liquid, into the machinery space. Significant oil leaks were noticed on the starboard generator and port main propulsion engine. Make necessary repairs to prevent oil leaks. 46 CFR 143.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: No longer leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Remove accumulation of oil from engine room bilge. 46 CFR 142.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: Approx. 4200 gallons of oily water removed by mobile transfer facility or transferred into slop tank.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 September 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Main switchboard has openings in front that are inadequately covered. Install permanent covers over missing breakers. 46 CFR 143.400(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2022
Resolution: Permanent covers were installed on switchboard. Note that this is the 3rd time this def has been issued since 2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Vessel port propeller was fouled during retrieval of tow line while in the process of attempting to reconnect dead ship tow of USS YORKTOWN in the Delaware Bay. On scene divers indicated that the port prop. was fouled with tow wire and that there was damage to the port strut, shaft tube, and propeller. Vessel is restricted from conducting towing operations. Vessel must be hauled out of the water so that damage survey can be conducted to the satisfaction of an attending CG Marine Inspector of the port prop and bottom of the vessel.46CFR143.205 - 705(C)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 September 2022
Resolved 14 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 18 September 2022
Resolved
The owner/managing operator/master of a towing vessel must ensure the strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. During retrieval of the lost tow line, the vessel's starboard tow winch was damaged and suffered multiple structural fractures at the base of the tow winch. Make vessel available for full examination of the damage to the starboard tow winch to the satisfaction of the attending CG Marine Inspector prior to conducting towing operations with the vessels starboard side tow winch. 46CFR140.801(a) 705(c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 September 2022
Resolved 23 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2022
Resolved
Machinery and electrical systems must be designed and maintained for the safe operation of the towing vessel and safety of persons onboard. The vessel's keel cooler system was not operating properly and required refilling of potable water to the system which the vessel did not have onboard to prevent overheating of the starboard main engine. Ensure a leak does not exist in the vessels keel cooler system and provide proper operation of the vessels starboard main engines to the satisfaction of the attending marine inspector. 46CFR143.205 60(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2022
Resolved 3 February 2023
Resolution: ABS report recieved attesting to the proper operation of both main engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 September 2022
Resolved
Rails or equivalent level protection must be installed near the periphery of all decks. During the retrieval of the lost tow wire the vessel's superstructure and mast collided with the USS YORKTOWN damaging handrails in the vicinity of the upper pilot house and support A damage survey of the upper pilot house and support shall be conducted to ensure the vessel is fit for service for it's intended route to the satisfaction of the attending CG marine inspector. 46CFR144.800 16(c)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 23 January 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 June 2022
Resolved
Electrical systems must be maintained to provide safe operation and safety of persons onboard. The vessel must not cause the structure or integrity of the vessel to be questioned by the [name withheld] engine room water tight bulkhead has a penetration with a cut and exposed wire in it that must be removed. The penetrations must then be sealed to ensure water tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: Wire was removed. Bulkhead penetration was sealed, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2022
Resolved
Rotating machinery must be protected by a cover or guard.
Air compressors did not have guards covering the pulleys and belts. Install proper guards.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: Air compressor guard was properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2022
Resolved
Exhaust pipes from an internal combustion engine must be insulated.
Exhaust lagging on the STBD main engine is missing/improperly installed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: Lagging was adjusted and determined to be SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2022
Resolved
All seals and gaskets must be maintained to prevent leaks of flammable of combustable materials.
Fuel transfer valves in the overhead of the engine room were leaking from the packing gland. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: Packing glands were tightened. Valves were cleaned. No signs of leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Extension cords must not be used as a permanent connection to a source of electrical power.
Berthing area is using an extension cord from a rack light to power a refrigerator. Remove and properly wire.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: The extension cord was removed and the mini refrigerator it powered was taken off the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Electrical systems and equipment must function properly to minimize shock hazards.
Distribution panel in the E/R has openings where breakers should be. Properly blank off these holes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 16 June 2022
Resolution: Openings were properly blanked off.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 December 2021
Resolved
Towing vessels must have a means to detect smoke in berthing areas and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217.
Forward crew berthing space port side found without a smoke detector.
46 CFR 142.330(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2021
Resolved 21 December 2021
Resolution: A new UL 217 smoke detector was purchased and installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 December 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space.
Emergency lighting in the engine room found inoperable.
46 CFR 143.410(b)
Action required: 10 - Deficiency Rectified
Due 20 December 2021
Resolved 20 December 2021
Resolution: Crew repaired emergency light identified and showed proper operation.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 20 December 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Identified a (6) multi outlet daisy chained to a three prong extension which was plugged into another extension cord in the master's cabin.
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 1 February 2022
Resolution: The operator contracted a third party electrician to install UL approved electrical receptacle in the Captain's cabin and bridge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 December 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Identified an inoperable ground fault detection bulb at the main switchboard for the port generator. It is unknown if a fault exists or if the conductor to the bulb is not functioning.
46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 1 February 2022
Resolution: The operator hired a third party electrician to install a new bulb and trouble shoot the ground fault detection system. The system now functions as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 December 2021
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Each drill must, as far as practicable, be conducted as if there was an actual emergency. Instructions and drills are required for recovery of a person overboard.
The man overboard procedures do not match the man overboard recovery method used by the crew during an actual drill.
46 CFR 140.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 3 January 2022
Resolution: Man overboard recovery procedures were updated by the company and placed onboard. The procedures were reviewed and match the procedures used by the crew during man overboard recovery drills.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 December 2021
Resolved
The owner or managing operator of a towing vessel must establish procedures to address fall overboard prevention and recovery of persons in the water.
Fall overboard prevention procedures were not found onboard.
46 CFR 140.425
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 3 January 2022
Resolution: Fall overboard procedures were updated by the company and implemented onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 December 2021
Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a lifejacket meeting requirements in 46 CFR 141.340, an immersion suit meeting requirements in 46 CFR 141.350, or a work vest approved by the Commandant under 46 CFR subpart 160.053.
Identified (2) work vests onboard that are not approved under 160.053. (3) approved work vests found onboard.
46 CFR 140.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 28 December 2021
Resolution: Vessel has placed (06) new Type V Personal Flotation Devices, Model 280, USCG Approval # 160.053/115/0.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 December 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
Identified a port hole on the engine room main deck starboard side with wasted dogs and unable to secure properly.
46 CFR 140.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 5 January 2022
Resolution: The crew repaired the port hole and sealed the mounting device. The port hole makes an adequate weather tight closing after repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 December 2021
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
Identified portable gasoline tanks stored on the 01 deck starboard side.
46 CFR 142.225
Action required: 10 - Deficiency Rectified
Due 20 December 2021
Resolved 20 December 2021
Resolution: Crew moved gasoline cans into approved cabinet on port side of vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 December 2021
Resolved
Cylinders used for containing hazardous ships' stores that are compressed gases must be filled, marked, and inspected in accordance with 49 CFR 173.301 through 173.308. Cylinder requirements for re qualification can be found in 49 CFR 180.207.
Identified oxygen cylinders onboard which were last re-qualified in 2006.
46 CFR 147.60(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 3 January 2022
Resolution: New oxygen cylinders that were stamped for inspection at appropriate intervals were place onboard.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 20 December 2021
Resolved
Except as provided in paragraph (5), shipboard incineration shall be allowed only in a shipboard incinerator. The vessel's ITC exceeds 400 GT, therefore, Annex VI is applicable.
The crew admitted to using an unapproved incinerator or burn barrel for garbage incineration on the previous international voyage. This is not in accordance with the vessel's garbage plan which states that all garbage shall be retained onboard and removed ashore by an approved reception facility. An approved incinerator is not onboard or listed on the EIAPP Certificate. The use of a burn barrel is not authorized.
MARPOL Annex VI Regulation 16
Action required: 10 - Deficiency Rectified
Due 20 December 2021
Resolved 20 December 2021
Resolution: The crew and company will be using the vessel's garbage plan procedures for all future voyages.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Tape is used to cover switchboard holes and openings. Electrical systems and equipment must function properly and minimize system failures and fired and shock hazards.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 23 July 2019