Inspection record

Last inspected 10 October 2025
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBP5989
382647
Flag
UNITED STATES
Maury page id
psix-382647

Documentation record

Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 73 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1992
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Net Ton
73 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

10 October 2025 Internal Structural Exam · Deficiency Check · MTSA Verification · Drydock Exam · Vessel Attendance · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8240949
10 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8045784
11 March 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7877220
23 June 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7484836
5 October 2020 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7066839
7 January 2019 Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604743
11 December 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314757
17 November 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6040455

Deficiency record · 51

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2026 Resolved
The intent of this part is to insure...auxillary machinery is suitable for the purpose intended. MI found fuel out leak on a fuel injector and fuel pump. 46 CFR 182.01-5(a) (old T)
Action required: 705 - Other - as specified
Due 14 January 2026
Resolved 10 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2026 Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure. MI found several cracked welds Id'ed on inspection to operator. 46 CFR 176.802(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 January 2026 Resolved
A vessel must comply with...the applicable the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MI found master with no Marine Radio Operator Permit on board. 46 CFR 184.504
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2026 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter. MI found expired floating waterlight batter on vessel. 46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2026 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current or each generator...A/C generator means for measuring frequency shall be provided. MI found Voltmeter, ammeter and frequency meter inoperable. 46 CFR 183.10-5(g) old t
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2026 Resolved
Inspection shall be in accordance with standards acceptable to OCMI as good marine practice. MI found label for "power available light" on generator switchboard and label for "center engine" shutdown on bridge to be missing. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 January 2026
Resolved 10 March 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2026 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weather tight. MI found all deck hatches with dry rotted and wasted rubber gaskets. 46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 January 2026 Resolved
The following signals, used or exhibited either together or separately, indicate distress and need of assistance: A continuous sounding with any fog-signaling apparatus. MI found ship horn to be inoperable. 33 CFR 87.01(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2026 Resolved
Inspection shall be in accordance with standards acceptable to OCMI as good marine practice. MI found alternator meter on bridge to be inoperable. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 10 March 2026
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 11 March 2024 Resolved
Radio transmitting and receiving installations or radiotelephones are required on certain vessels carrying passengers. Details of the application of this requirement as well as the details of the installation shall be set forth in the regulations of the Federal Communications Commission. The radios on board the vessel was unable to stay on to conduct a radio check. Repairs should be made to meet the satisfaction of the attending marine inspector. 46 CFR 184.25-1(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 March 2024
Resolution: Received confirmation of crew conducting a radio check.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 11 March 2024 Resolved
The ring life buoy shall be so placed as to be readily accessible .It shall be capable of being cast loose, shall not be permanently secured in any way, and shall have attached to it a line of at least 60 feet in length. The line on the ring buoy on board the vessel was not 60 feet. Line needs to be replaced to meet the satisfaction of the attending marine inspector. 46 CFR 180.30-10 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2024
Resolution: Received evidence of neccessary repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 March 2024 Resolved
Annual Inspection. Your Vessel must undergo an annual inspection within 3 months before or after each anniversary date. 46 CFR 176.500 a(1)
Action required: 10 - Deficiency Rectified
Due 29 March 2024
Resolved 29 March 2024
Resolution: Conducted annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2022 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. THE GENERATOR ONBOARD THE VESSEL WAS EXCESSIVELY SMOKY AND LEAKING FUEL. CONDUCT NEEDED REPAIRS. 46CFR183.01-15 - PRIOR TO CONDUCTING OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Vessel installed a new fuel rack and corrected the issue. All Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it’s installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The mounting system for the Center Main Engine has failed. Conduct needed repairs. 46CFR182.05-1 - Prior to conducting operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Repairs were conducted. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2022 Resolved
In keel cooler installations, short lengths of approved non-metallic flexible hose, fixed by two hose clamps at each end may be used. The center main engine is leaking jacket water at the hull penetration due to dryrotted hose and single hose clamps. Renew hose and install double hose clamps as required. 46CFR182.422(d) - Prior to conducting operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Repairs were conducted. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022 Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting the motion of the boat. The batteries were sitting in a bucket of water. 46 CFR 183.05-20(b) - Prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Batteries were removed. All Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 October 2022 Resolved
Employers must ensure that they and their crewmembers meet the requirements of 46 CFR 16 – Chemical testing. Vessel was unable to show proof of pre-employment testing or enrollment in random drug testing program. 46CFR16.203(a) - Prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: Verified company compliance with chemical testing program requirements.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it’s installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Marine inspector identified a lube oil leak on the Port and Starboard main engines. Conducted needed repairs. 46CFR182.200(a) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Repairs were conducted of the MEs. All Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2022 Resolved
Exhaust piping shall be gastight throughout the length of the piping. Marine inspector identified an exhaust leak on the Port main engines. Conducted needed repairs. - 46 CFR 182.15-20(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Repairs conducted. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 October 2022 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. Machinery guards are missing on all machinery. Provide machinery guards. 46 CFR 182.01-5 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: New guards were created and installed. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 17 October 2022 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places. Insulation needed to protect personnel from high temperatures were missing on the exhaust and jacket water return for all three main engines. - 46 CFR 177.35-15 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: New lagging was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2022 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and meet any of the requirements within the part. Vessel had multiple dead end wires within the navigation console. Remove dead end wires or place within approved receptacles. - 46 CFR 183.340(g) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
Resolution: Dead end wires removed from under the navigation console.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2022 Resolved
All equipment, including switches, fuses, lampholders, etc. shall be of a type designed for the potential involved and so identified. Outlet on the navigation panel was damaged and inoperable. Conduct needed repairs. - 46 CFR 183.10-20(i) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Outlet was renewed. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2022 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level in each of the following normally unmanned spaces: a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Engine room bilge high level alarm visual indicator inoperable. Conduct needed repairs. - 46 CFR 182.530 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
Resolution: Verified proper operation of bilge alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2022 Resolved
All electrical installations shall be to the satisfaction of the satisfaction of the Officer in Charge, Marine Inspection. Repair or remove broken Public address system and associated wiring. - 46 CFR 183.01-15(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
Resolution: Broken PA system was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022 Resolved
Each battery must be located as high above the bilge as practicable and secured to protect against shifting with motion of the boat. The vessel had multiple old batteries not secured and stored in the engine room. - 46 CFR 183.05-20(b) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Batteries were removed. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 October 2022 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Bulwark has numerous fractures in plating and cracked welds. Conduct needed repairs. - 46 CFR 177.35-1(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
Resolution: Fractures in bulwark have been welded.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 October 2022 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Accessible parts of the exterior and interior of the hull. There were multiple cracked welds in the numbers 1-5 voids. Identify and repair damaged welds. - 46 CFR 176.25-5 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Welds were repaired. All Sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 October 2022 Resolved
Man over board and firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide logs of any drills or training conducted. - 46 CFR 185.520(f) 46 CFR 185.524(d) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Logs were provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 October 2022 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date Tide Tables and Current tables. Vessel does not have a current tide table or currents table. Update navigation pubs, or use an electronic updated means. - 46 CFR 185.20-35 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2022
Resolution: Vessel has new publications onboard.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 17 October 2022 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Stbd side bridge window is cracked. Conduct needed repairs/replacement. - 46 CFR 177.1030 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Window was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The generator onboard the vessel was found inoperable. Corrected during inspection. - 46 CFR 183.01-15(a)
Action required: 10 - Deficiency Rectified
Resolved 17 October 2022
Resolution: Rectified during the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 October 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The vessel did not have a first aid kit on board. Corrected during inspection. - 46 CFR 184.710
Action required: 10 - Deficiency Rectified
Resolved 17 October 2022
Resolution: Rectified during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2022 Resolved
An adult life jacket must be provided for each person carried on board the vessel. 01 life jackets was found not in serviceable condition leaving the vessel with 09 life jackets. 10 life jackets are required as per the COI. Corrected during inspection. - 46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 17 October 2022
Resolution: Rectified during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2022 Resolved
The number lifejackets stowed inside and their size must be marked in clearly legible letters and numbers on each container. Number of lifejackets stowed in that location was incorrect. Corrected during inspection. - 46 CFR 185.604(f)
Action required: 10 - Deficiency Rectified
Resolved 17 October 2022
Resolution: Rectified during the inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2022 Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has been out of service since being damaged during Hurricane Ida (AUG 2021) and failed to undergo first annual inspection within the 3 months before or after the anniversary date. Vessel's anniversary date is based off Certificate of Inspection issuance date of 26OCT2020. Vessel must complete satisfactory annual inspection prior to returning to service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2022
Resolved 12 December 2022
Resolution: Completed annual inspection
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2020 Resolved
Installations of power fire pumps, fire main systems and fixed fire extinguishing systems on vessels constructed on or before June 1, 1958 shall meet the requirements of this part. The valve on the nozzle of the fire main line was missing, therefore prohibiting water from flowing. Replace valve handle and prove proper operation of the fire pump system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 November 2020
Resolution: Verified installation of firemain valve at the deck and witnessed satisfactory operation of the firemain system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020 Resolved
Installations and equipment accepted by the Coast Guard as meeting the applicable requirements in this subchapter in effect on the date the installation was contracted for and which are maintained in good serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, may be continued in use until replacement is ordered by the Officer in Charge, Marine Inspections. Vessel's batteries were unable to hold a sufficient charge for their intended use.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: Witnessed satisfactory start of the #2 MDE from battery power.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020 Resolved
Each generator must meet the applicable construction and test requirements of Section 35 of the American Bureau of Shipping's "Rules for Building and Classing Steel Vessels". Vessel's generator windings were dirty with oil soaked dust. Rectify before use of generator.
Action required: 705 - Other - as specified
Resolved 5 November 2020
Resolution: Verified that the generator windings were cleaned and witnessed the satisfactory start and running of the generator.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 5 October 2020 Resolved
Each ring life buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter. Vessel's ring life buoy had insufficient retro-flective tap, and the plug was wasted/broken allowing water/weather intrusion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2020
Resolution: Verified installation of new satisfactory life ring.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 January 2019 Resolved
At all inspections, special attention shall be paid to ensure that no fire hazards exist. Center Main Diesel Engine has a fuel leak from cylinder return elbow connection. Repair to satisfaction of attending USCG MI on or before 14JAN19. 46 CFR 176.25-10(b) 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 January 2019
Resolved 16 April 2019
Resolution: Elbow connection was tightened and rewelded. Observed satisfactory leak-free operation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 January 2019 Resolved
The general construction of the vessel shall be such as to minimize fire hazards. Openings for electrical wiring between engine room and pilothouse console were not vapor tight. Repair to satisfaction of attending USCG MI on or before 14JAN19. 46 CFR 177.10-5(a) 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 January 2019
Resolved 16 April 2019
Resolution: Openings were partially welded with aluminum plate, in conjunction with use of fire retardent insulation and finished with firestop adhesive caulking.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 January 2019 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in the lazarette and machinery space. Visual and audible alarms in both spaces were inoperable. Repair to satisfaction of attending USCG MI on or before 14JAN19. 46 CFR 182.530 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 January 2019
Resolved 19 April 2019
Resolution: Verified satisfactory operation of bilge high level alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2019 Resolved
An adult life jacket must be provided for each person carried onboard a vessel. 01 lifejacket was found to be deteriorated. Vessel provided replacement prior to completion of inspection. 46 CFR 180.71(a) 10c
Action required: 10 - Deficiency Rectified
Due 7 January 2019
Resolved 7 January 2019
Resolution: Vessel provided replacement for lifejacket prior to completion of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 January 2019 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. Found existing Bridge-to-Bridge Safety Certificate was expired. Provide proper documentation to satisfaction of attending USCG MI by 21JAN19. 47 CFR 80.903 16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2019
Resolved 16 April 2019
Resolution: Verified a valid renewal certificate was on board vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 7 January 2019 Resolved
Each EAP education program must include display and distribution of a community service hot-line number for crew member assistance. Found existing EAP program had incorrect contact information. Update existing program to the satisfaction of the attending USCG MI by 21JAN19. 46 CFR 16.401(a) 16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2019
Resolved 16 April 2019
Resolution: Verified Program was updated with proper information and posted.
Fire Fighting › Nozzles › Type
Issued 11 December 2017 Resolved
Garden type fire hose needs to be fitted with a nozzle capable of being changed between solid stream and spray pattern.
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 12 December 2017
Resolution: Company purchased new nozzles for effected vessels.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 November 2016 Resolved
Onboard COD expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 30 November 2016
Resolution: COD current and verified in MISLE.
Lifesaving › Hand Flares › Not on Board
Issued 17 November 2016 Resolved
x1 red hand flare missing. Corrected on the Spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Added x1 red hand flare.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 November 2016 Resolved
MI found x7 life jackets where the internal floatation material was deteriorated leaving vessel x1 lifejacket short of required. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Added x1 life jacket, verified appropriate markings.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2016 Resolved
STBD Engine PTO for Bilge/Fire pump missing machinery guard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 30 November 2016
Resolution: Recieved sufficient eveidence of installed guard protecting pto for fire/bilge pump machinery.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.