MAURY USCG vessel records Sign in
← All vessels

CLELIAMAR

CLELIAMAR is a 1993 tank ship. The Coast Guard has recorded 51 inspections since 1993, most recently in January 2011, along with 48 deficiencies and 14 operational controls.

Records from 1993 to 2011. Most recent: inspection, 27 January 2011.

Built
1993
Last inspected
27 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9001590 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
386443
Flag
LIBERIA
—
Maury page id
psix-386443

Inspections, by type

…with no type recorded26
Years with a record 14 calendar years (1993–2011)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it38653 - Convention (Subpart B), Gross Ton
20535 - Convention (Subpart B), Net Ton
81587 - Displacement, Ton
68500 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 6

Inspection history · 51

27 January 2011 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3929923
10 December 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3647901
12 March 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3432140
28 January 2009 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3401590
27 January 2009 PI Safety Exam · Deficiency Check · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3401285
27 January 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3401308
27 January 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3401320
16 December 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Annual · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3380797
16 April 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3185273
11 April 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3182319
29 September 2007 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3069117
29 January 2007 ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2863399
8 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2852268
7 July 2006 ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2705575
16 May 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2650541
16 May 2006 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2650885
2 February 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2577949
28 October 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2524322
26 October 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2522920
19 September 2005 MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2495968
17 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2496193
14 August 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2463118
23 May 2005 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2366275
17 April 2005 COC-TVE Annual
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2335667
17 April 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2366087
15 April 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2334970
9 April 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2329927
8 January 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2272076
6 January 2005 Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2269979
10 December 2004 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2257087
3 December 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2253094
29 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2249483
29 November 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2249859
15 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2241084
19 October 2004 Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2223658
22 June 2004 ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2107285
6 May 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2060293
23 March 2004 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2029595
30 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1805877
17 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1775393
27 February 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489865
5 January 2002 Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1475691
7 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 534998
4 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 285560
4 January 2001 Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1056908
5 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 279408
11 December 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 435544
11 December 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415287
8 August 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 418867
8 August 1998 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1131405
24 March 1993 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389631

Deficiency record · 48

Lifesaving › Lifeboat › Exhaust Pipe
Issued 27 January 2011 Resolved
0610- Lifeboats- Vessel lifeboat which serves as rescue boat is leaking exhaust gases into enclosed lifeboat. SOLAS 74 (a) I/11
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 28 January 2011
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. The damaged exhaust pipe was replaced, and tested satisfactory.
Engineering › Steering Gear System › Pump
Issued 27 January 2011 Resolved
2099- Other- When using the #2 steering gear pump, the rudder is not capable of being moved to 35 degrees starboard, and can only go to 32 degrees starboard.
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 28 January 2011
Resolution: Received, reviewed, and accepted class report from [name withheld] stating the deficiency was rectified. Pilot rod of hydraulic bottle of steering gear pump No. 2 was adjusted to minimize the difference between port and starboard rudder angles.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 December 2009 Resolved
Sector Houston-Galveston received a LOD in regards to the vessels Secondary Marine Radar system. 33CFR 164.37(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2009
Resolution: Received a Tech report attesting to the proper repair and operation of the Secondary Marine Radar system.
Engineering › Fuel Oil Service System › Piping
Issued 27 January 2009 Resolved
1400: All of the generators failed during the vessel's transit. Cause was due to blockage of fuel oil lines from the Diesel Oil Service Tank. All of the pipes and associated items leading to the generators must be cleaned and checked by the Class Representative prior to the vessel's departure. No reports have been submitted to the company by the ships PMS or SMS regarding these problems.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Received a report from Class and the fuel oil tank and all of its accessories will be dealt with by 15 February 09.
Engineering › Freshwater System (cylinder head cooling) › Level Control
Issued 27 January 2009 Resolved
1499; The radiator for the emergency Generator is leaking which could cause the engine to overheat if used for an excessive amount of time during an emergency. In addition the canvas transition ducting for the air intake is holed. No reports have been sent to the company as per the ship's SMS regarding these. Class must inspect prior to the vessel's departure from San Francisco.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 27 January 2009 Resolved
1400; The Diesel Oil Purifier is leaking fuel into the bilge area. No reports have been sent to the company regarding this problem as per the ships PMS and SMS System. Class must inspect the system prior to the vessels departure from San Francisco Bay.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Engineering › Steering Gear System › Power Unit
Issued 27 January 2009 Resolved
0936; During the testing of the steering system hydraulic leaks were found on the port / starboard steering units, starboard auto-pilot unit and mooring winch hydraulic power unit. No reports have been sent to the company regarding these by the ships PMS or SMS System. Class must inspect prior the vessel departure from San Francisco.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Engineering › Sea-water System (primary cooling) › Valve
Issued 27 January 2009 Resolved
1400; The Actuator for the salt water cooling valve between the #1 and #2 Auxiliary Generators is leaking lube oil into the bilge. No reports have been sent to the company by the ships PMS or SMS regarding this. Class must inspect the system prior to the vessel departure from San Francisco.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 27 January 2009 Resolved
1899; Number 1 Blower; Inert gas is leaking past he drive shaft seal, both S/W pipes are leaking and the drive shaft bearing housing is leaking oil. Scrubber; S/W cooling pipe on inlet is patched at the flue inlet and salt water is leaking out of the flue gas inlet flange. No reports have been sent to the company regarding these as per the ship's SMS or PMS system, Class must inspect.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Ventilation Systems › Ducts
Issued 27 January 2009 Resolved
0510; The Ventilation ducting above the incinerator is holed and is excessively deteriorated. No reports have been sent to the company as per the ship's SMS or PMS schedule. Class must inspect this before the vessel departs from San Francisco.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2009 Resolved
1550; The port navigation light lens is cracked and when in operation there is a white section of light showing. The starboard navigation lens is also cracked in several places but it does not show any white section when in operations. Both of the lights have the incorrect size and type of lamps in them. No reports have been sent to the company regarding these and Class must inspect.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Port light was replaced and a new light has been ordered for the starboard one both were tested to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 27 January 2009 Resolved
0710; The natural air vents around the house do not work as designed. Securing devices do not work or they are wasted. STBD bridge wing vent to A/C intake, bridge locker vent, battery room vent, air vents leading to steering and vent above A/C entrance. In addition the ducting in the fwd Bosn's stores is holed and wasted. No reports have been sent to the company regarding these by PMS or SMS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the vents were tested to the satisfaction of the attending Classification Society Representative.
Lifesaving › Lifeboat › Hull
Issued 27 January 2009 Resolved
0610; Port L/B next to the coxswain seat there is a chamber which attaches to the hull. The chamber is pulling away from the hull and crew has filled the crack with silicone. Both L/B engine covers and deck around the engine can not be secured. No reports have been sent to the company as per the ship's SMS or PMS regarding these and Class must address prior to the vessel's departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 January 2009 Resolved
0710; Class needs to inspect the following doors that do not operate properly, self closing devices are not working, doors are wasted or holed. Door between E/R and steering, door between passageway and engineers changing room, emergency escape door at boiler deck damaged, crew laundry room door B0 holed. Class also needs to look at the bulkhead in locker #334 which is holed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made to the satisfaction of the attending Classification Society Representative.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 27 January 2009 Resolved
1820; The grounding strap for the ballast line port side is wasted, the deck seal drain line is leaking water into the space. Approximately 95% of the grease fittings for the cargo valves have been painted over several times and it's apparent that no maintenance has been carried out on these for some time. PMS reports sent to the company reflect that all items are serviced on a regular basis.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2009
Resolved 29 January 2009
Resolution: Repairs were made and the systems were tested to the satisfaction of the attending Classification Society Representative.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 27 January 2009 Resolved
0330; The Sewage system is not being maintained as per the manufacturers requirements. Daily, weekly, monthly, semi annual and annual test have not been carried out. No chlorine tablets were on board and the ship's crew does not have a chlorine test kit on board. System has a certificate from Class which approves the inspection and operation of the system under MARPOL Annex IV.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 29 January 2009
Resolution: Tablets and a chlorine test kit have been placed on board and a maintenance schedule has been incorporated into the PMS system as per the manufacturers requirements.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 27 January 2009 Resolved
0720; The compressor for recharging the SCBA bottles has not been maintained as pre the manufacturers. to been carried out. The crew has jury-rigged a starting capacitor for the electrical motor and the air filter housing is being held in place by cellophane tape. The safety guard is missing for the cooling fan and some of the fan blades are broken.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 29 January 2009
Resolution: Repairs were made and the system was tested to the satisfaction of the attending Classification Society Representative.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 27 January 2009 Resolved
1820; There are no non-sparking tools on board that can be used in the pump room or on deck.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 12 March 2009
Resolution: New non-sparking tools have been provided to the crew and verified to be on board by ABS ISM auditor.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 27 January 2009 Resolved
2120; Mixed garbage was found in all of the containers at the final collection point prior to disposal at sea. All of the containers were properly color coded and marked but the crew failed to separate any of it. Additional garbage was found in plastic bags in some of the storage lockers inside the house. Crew training needs to be conducted and they need to follow the plan more closely.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 29 January 2009
Resolution: Training has been conducted for all crew regarding garbage.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 27 January 2009 Resolved
0735; The pants and jackets are in good condition but the reflective tape is starting to come off. No one has addressed this problem with the company as per the ships SMS or PMS system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 29 January 2009
Resolution: The fire Coats have been replaced.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 27 January 2009 Resolved
0750; The hatch leading into the engine room is not secured properly. Bolts are missing around the hatch cover which makes it not weather proof and if there was a fire in the engine room and CO2 was released it would leak out though the hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 29 January 2009
Resolution: Crew has been instructed on the proper procedures for keeping hatches closed for seagoing conditions and security reasons.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 27 January 2009 Resolved
0950; The company must provide documentation that the electrical matting throughout the vessel is rated for the proper voltage and meets the safety requirements as outlined in SOLAS. There are several different types of matting used and some are torn, or completely worn out which will not provide any protection for the crewmembers.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 12 March 2009
Resolution: Documentation was provided for the electrical matting and verified by the ABS ISM auditors.
Operations/Management › Ballast Water Managment › Training
Issued 27 January 2009 Resolved
2510; Company must provide documentation that the officers have received Ballast Water Management Training as per section 5 of the plan. The crew understands why they exchange ballast at sea but the do not fully understand how the system works on this vessel or any safety precautions as set by the company or Master on when not to exchange ballast.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 12 March 2009
Resolution: Documentation is being held and recorded in the Ballast Water Management Plan and verified by the ABS ISM auditors.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 January 2009 Resolved
2100; Company or Master must update and maintain the local contact numbers as per section 2.3 and appendix 7 of the plan, MARPOL Annex I / 37- 2.4.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2009
Resolved 12 March 2009
Resolution: All local contact numbers were updated and placed in the SOPEP as per the instructions and verified by the ABS ISM auditors.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 27 January 2009 Resolved
2500; The Captain of the Port of San Francisco questions the adequacy of the implementation of the vessel's Safety Management system under the International Safety Management Code. An external audit is recommended to be conducted by the flag state or recognized organization to determine whether the ship is operating in accordance with the ISM code within the next 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2009
Resolved 12 March 2009
Resolution: The ABS Classification Society carried out the ISM audit. One non-conformity and four observations were recorded.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 11 April 2008 Resolved
Received notification that the vessel's echo depth sounder is not functional. Vessel must have a working echo depth sounder. An LOD was issued for entry into the San Francisco Bay area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2008
Resolution: Received a tech report stating that a new echo depth sounder had been installed on the vessel. The new depth sounder is working properly.
Deck/Cargo › Cargo Heating › General
Issued 29 September 2007 Resolved
1960 On the stbd side of the vessel, a flex coupling in the steam line has failed and is leaking. SOLAS (as amended) Ch II-1/Reg 33.1) 70a
Action required: 15 - Rectify deficiencies by next port
Resolved 3 October 2007
Resolution: Received a Class Report describing the following repairs: The leaking coupling renewed with spare unit. Testing of coupling was not carried out due to operational reasons. Condition of class issued now for completion of repairs.
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2007 Resolved
0999 Centerline behind 5 stbd and 5 port vents, the conduit line is broken and is cutting into the electrical lines it is supposed to protect. SOLAS (as amended_ Ch II-2/ Reg 45 5.5 70a
Action required: 15 - Rectify deficiencies by next port
Resolved 3 October 2007
Resolution: Received a Class Report describing the following repairs: The damaged conduit line found temporarily repaired now. A condition of class issued now for permanent repairs.
Deck/Cargo › Inert Gas System › Venting System
Issued 29 September 2007 Resolved
PV valves for the 4C and 2P tanks will not seal. Provide class report attesting to the proper operation of the PV valves. SOLAS (as amended) CH II-2/Reg 4 2.2.4
Action required: 15 - Rectify deficiencies by next port
Resolved 3 October 2007
Resolution: Received a Class Report describing the following repairs: The leaking P/V valves were overhauled by ship staff. Sealing of valves was witnessed after overhauling under IG working pressure 600mm Water Column and no leak was found.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 September 2007 Resolved
Watertight hatch for steering gear room does not seal.
Action required: 705 - Other - as specified
Resolved 30 September 2007
Resolution: Hatch gasket replaced. Can no longer see daylight when the hatch is sealed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 19 September 2005 Resolved
The aft seal on the Stern Tube is wasted. Salt water is leaking in contaminating the lube oil. Vessel needs to replace all three seals. SOLAS Ch. I/IIa
Condition: Unknown
Due 20 September 2005
Resolved 19 September 2005
Resolution: Tech report received by fax stating all repairs were finished.
Deck/Cargo › Inert Gas System › Venting System
Issued 17 April 2005 Resolved
Fixed Oxygen Analyzer for IGS Calibrating readings to do not match span gas bottle readings. Provide proof of calibration with certified span gas bottle to satisfaction of class. SOLAS 74-II-2/18 Correct prior to next US Port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 May 2005
Resolved 23 May 2005
Resolution: The repaired to the satisfaction of class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 April 2005 Resolved
Fire doors do not close. SOLAS 74 II-2/47. Correct prior to next US Port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 May 2005
Resolved 23 May 2005
Resolution: Vessels Fire doors repaired to the satisfaction of class.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 19 October 2004 Resolved
AIS has alarm and technician is presently onboard to conduct servicing. provide technician report upon completion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2004
Resolution: Received Radio Holland technicians report for repair of the AIS
Engineering › Sea-water System (primary cooling) › Pump
Issued 19 October 2004 Resolved
Make permanent and proper repairs to the sea water in let to the #1 S/S generator, pipe has a soft patch.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 29 November 2004
Resolution: Received report #CLO 0400114, from Lloyd''s Register showing that item has been corrected.
Engineering › Compressed Air System (start air) › Piping
Issued 19 October 2004 Resolved
Make permanent and proper repairs to the jack water inlet valve for the #1 air compressor.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 29 November 2004
Resolution: Received report #CLO 0400114, from Lloyd''s Register showing that item has been corrected.
Deck/Cargo › Crude Oil Washing Systems
Issued 5 January 2002 Resolved
Replace/repair bonding strap on valve "R62" in way of port overboard decanting/wash line in pump room (cargo). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Inspected item and found bonding strap replaced satisfactory.
Deck/Cargo › Inert Gas System
Issued 5 January 2002 Resolved
Repair deck seal vent line in way of pump rom (cargo) where wasted. LEGACY COMPONENT DESC: Water Seal
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Inspected deck seal water line vent and found satisfactory repair.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 January 2002 Resolved
Mark emergency generator radiator air intake closure with "In case of fire close vent cover" or equivalent statement on exterior of E/G room aft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Inspected emergency generator space and found proper statement stencilled on bulkhead.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 5 January 2002 Resolved
Repair leaking steam valve on composite boiler in way of engine room heating line. LEGACY COMPONENT DESC: Valve, Vent
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Inspected item and found leak satisfactorily repaired.
Engineering › Bilge Water Management System
Issued 5 January 2002 Resolved
Provide class attestation of bilge piping and pumps (bilge) in way of E/R. Remove all temporary hoses from bilge pick up boxes and asociated manifold connections. LEGACY COMPONENT DESC: Piping
Due 5 January 2002
Resolved 7 January 2002
Resolution: Received surveyor''s report and cleared item.
Engineering › Feedwater/Condensate Water System
Issued 5 January 2002 Resolved
Provide class attestation of acceptance of condition of vessel feed water system/piping. Remove flexible hoses feeding into cascade tank from A/C condensate, condensate inspection tank and fresh water generator.
Due 5 January 2002
Resolved 7 January 2002
Resolution: Received surveyor''s report and cleared item.
Navigation › Collision/Grounding Avoidance
Issued 5 January 2002 Resolved
Provide a technician's report attesting to the proper operation of the #2 radar system prior to the departure from Pt. Everglades, FL. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Examined technician''s report stating seconday radar repaired.
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2002 Resolved
Provide receipt for Port of Miami chart prior to departure from Pt. Everglades, FL.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2002
Resolved 6 January 2002
Resolution: receipt provided
Lifesaving › Lifeboat Equipment
Issued 5 January 2002 Resolved
Provide lithium batteries for all GMDSS lifeboat radios. LEGACY COMPONENT DESC: Radio (fixed two-way VHF radio-telephone)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Examined master''s purchase request for new batteries.
Navigation › Piloting/Steering
Issued 5 January 2002 Resolved
Provide 2002 Tide Tables and Tidal Current Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 27 February 2002
Resolution: Observed 2002 editions of required publications were on board.
Deck/Cargo
Issued 4 January 2001 Resolved
REPAIR WASTED SEA WATER PIPING FOR DECK SEAL IN CARGO PUMP ROOM PORT SIDE WITHIN 30 DAYS.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Navigation
Issued 11 December 1999 Resolved
ARPA IS MISSING THE PERMANENTLY AFFIXED LABEL. OBTAIN NO LATER THAN 90 DAYS. CAN FAX A COPY TO USCG.
Condition: Unknown
Due 16 December 1999
Resolved 17 December 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.