Records from 1993 to 2008. Most recent: inspection, 20 February 2008.
Inspection history · 27
20 February 2008
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3151225
12 January 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2565566
9 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2588102
1 November 2005
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2520783
24 June 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2408003
23 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2392416
23 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2426597
22 December 2004
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2263483
12 November 2004
COC-TVE Annual · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2241251
25 September 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1912611
8 May 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 277477
7 May 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 189009
29 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 432161
29 August 1999
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 784099
8 July 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 511635
29 January 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425169
20 October 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 421629
3 August 1998
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 470040
26 May 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416213
11 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410858
10 October 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 187525
28 May 1997
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 774003
28 May 1997
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 784146
27 May 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403999
21 April 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390250
21 April 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 377251
23 October 1993
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848160
Fire Fighting › Fire Hoses › Condition
Issued 20 February 2008
Resolved
6 fire hoses stored on deck near the paint locker were found to have holes in them. The holes were of sufficient size to impair firefighting effectiveness.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2008
Resolution: The hoses were replaced with extras from the ship''s stores and the ship has ordered 6 new hoses.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 November 2005
Resolved
All piping forward of the superstructure is corroded.
Action required: 705 - Other - as specified
Resolved 12 January 2006
Resolution: As per Class Report; crew has chipped and recoated piping on cargo block deck, specifically inert gas piping supports and stanchions. All now sighted found in good order.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 1 November 2005
Resolved
High level alarm is only visible from the port side.
Action required: 705 - Other - as specified
Resolved 12 January 2006
Resolution: As per Class Report; crew has made two additional placards to be affixed to mid-ship stanchion post indicating COT High Level Audible and Visual Alarm. These placards now in place , visible from all locations on deck. All now found in good order.
Deck/Cargo › Mooring/Anchoring › Standard Link (anchor chain)
Issued 12 November 2004
Resolved
outboard shot on starboard anchor chain stud links noted to be worn and fractured
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 December 2004
Resolved 22 December 2004
Resolution: Received DNV class report attesting to repairs
Documentation
Issued 27 May 1997
Resolved
PROVIDE LOCAL COAST GUARD WITH EXPLANATION FROM CLASS WHY VESSEL DOES NOT MEET MARPOL ANNEX I REG 13G. REVISE IOPP CERTIFICATE IF NECESSARY.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997