Inspection history · 158
23 June 2021
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7233864
8 October 2020
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7073718
18 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955324
11 October 2018
In-Service Inspection · Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6558990
9 September 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6536847
15 November 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6307736
15 October 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6372529
17 March 2017
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6108660
20 January 2017
Internal Structural Exam · Cargo Tank Internal · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6072737
14 December 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6057602
13 June 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5905807
2 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5894886
23 June 2015
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5162067
15 June 2015
Periodic Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5150511
4 June 2015
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5144790
15 July 2014
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4923452
17 June 2014
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4891160
2 June 2014
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4877497
3 March 2014
Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4817602
21 September 2013
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4720147
6 September 2013
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4711050
13 August 2013
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4683932
3 July 2013
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4643156
17 June 2013
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4622916
20 July 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4384893
1 June 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4330723
29 May 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4326882
1 May 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4299517
10 April 2012
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4283821
6 April 2012
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4280605
5 January 2012
Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4221460
5 August 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4113247
14 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4082122
9 December 2010
Annual Inspection · MARPOL Annex V Examination · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3907306
25 April 2010
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3724790
25 March 2010
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702833
24 March 2010
MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey · Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702274
28 September 2009
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3604811
21 April 2009
MARPOL Annex VI Survey · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3472086
25 March 2009
Annual Inspection · MARPOL Annex V Examination · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3439642
12 March 2008
MARPOL Annex V Examination · Plan Review (Other than "T") · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3163226
21 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3151439
17 December 2007
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3116923
27 November 2006
Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2829375
11 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743988
1 March 2006
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2594181
3 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578846
25 May 2005
MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2366603
12 May 2005
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2356847
11 April 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2330914
11 March 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2308337
10 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2273332
24 November 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2247440
23 November 2004
Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2247115
17 November 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2242786
11 November 2004
Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2239719
27 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2079862
11 March 2004
MARPOL Annex II Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2021069
1 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2015909
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962294
23 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1824354
15 April 2003
Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1796453
6 September 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1692211
18 January 2002
Internal Structural Exam · Cargo Tank Internal · COI Inspection · Construction Oversight · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1476505
4 January 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058704
5 December 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 517269
12 October 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1055393
1 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 447862
23 February 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 94859
5 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 492468
24 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 517430
7 October 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789047
6 October 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123449
8 July 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 511635
25 June 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1451422
10 June 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 809307
21 May 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 475100
19 April 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 532862
7 April 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 508573
14 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 61209
12 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424471
8 January 1999
Examination of Repairs · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045743
17 November 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 197488
17 November 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 440354
17 November 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 767610
4 June 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 538430
14 November 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108275
2 August 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 494713
15 July 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 493687
12 June 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1110848
29 April 1997
Deficiency Check · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430386
17 January 1997
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433124
17 September 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 531070
11 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 666838
1 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 517133
16 November 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187975
25 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 20735
25 October 1995
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414528
7 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 862760
19 January 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374207
18 July 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863005
13 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436886
16 April 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 857074
24 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 508020
7 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 126116
18 January 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850820
21 December 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159564
8 December 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 849488
17 November 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1145983
5 February 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837395
27 November 1991
MARPOL Annex II Examination · Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944204
22 January 1991
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 914525
15 November 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1244628
14 September 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211766
12 July 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 524278
20 December 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903148
20 December 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914448
26 November 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 454738
22 November 1989
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1239592
13 June 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206767
10 May 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 499420
15 January 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 495936
28 December 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346829
15 December 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338857
13 December 1988
Damage Survey · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898722
4 December 1988
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897817
4 November 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 451896
23 May 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 494041
23 May 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 893937
6 November 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 436645
2 November 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021520
2 November 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329253
15 April 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 468947
25 February 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309005
11 February 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012585
6 January 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019756
6 January 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317760
31 October 1986
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020250
8 July 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 480197
12 June 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 309510
12 June 1986
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 989566
15 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 483395
15 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 517866
20 April 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 509882
15 March 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 450008
7 November 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989640
7 November 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001526
26 October 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 525450
17 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980553
26 March 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 447703
15 February 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 300391
14 January 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1285496
13 December 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287949
6 November 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 531401
17 October 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977609
9 November 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 981253
9 November 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1275586
18 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968642
02 - Structural Conditions › N/A - No Subsystem › Cargo area segregation
Issued 26 October 2018
No resolution recorded
VESSEL MUST MAINTAIN THE SAFETY REQUIREMENTS REQUISITE TO THE ISSUANCE OF A CERTIFICATE OF INSPECTION. PROVIDE REPAIR PROPOSAL TO CG FOR WASTED AREAS OF TRANSVERSE BULKHEADS BETWEEN THE #5, #6, AND #7 CARGO TANKS.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Cargo area segregation
Issued 12 October 2018
Resolved
VESSEL MUST MAINTAIN THE SAFETY REQUIREMENTS REQUISITE TO THE ISSUANCE OF A CERTIFICATE OF INSPECTION. INTEGRITY OF CARGO TANKS 6S AND 6P QUESTIONED FOLLOWING FAILURE OF VAPOR-TIGHTNESS TEST. MAKE AVAILABLE FOR INSPECTION.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 October 2018
Resolution: INSPECTED 6S AND 6P TANKS WITH SCAFFOLDING. ID'D AREAS OF WASTED STEEL VIA GAUGING REPORT AND VISUAL INSPECTION.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2018
No resolution recorded
THERMAL FLUID HEATER TO BE LOCKED OUT/TAGGED OUT UNTIL SATISFACTORY TESTING PROVIDED TO ATTENDING MARINE INSPECTOR.
Due 23 September 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2018
No resolution recorded
ELECTRICAL PANEL MUST HAVE BLANK COVERINGS INSTALLED. REPAIR PANEL OPENINGS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Due 23 September 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 September 2018
No resolution recorded
FUEL TANK VENT FLAME SCREENS HAVE HOLES IN MESH. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR. BOTH FUEL TANKS AND AFT PEAK VOID.
Due 23 September 2018 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 16 November 2017
Resolved
Watertight integrity of multiple voids and ballast tank compromised due to seized dogs and hatch cover gaskets. Repair and replace as necessary.
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: seized dogs freed or replaced and wasted gaskets renewed throughout.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 November 2017
Resolved
During cargo discharge MI observed cargo pumps #3 & #4 STBD side actively leaking excessively. Prior to use during cargo operations make repairs to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2017
Resolved 20 November 2017
Resolution: Vessel rep provided shipyard report attesting to the condition of old packing and the installation of new packing.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 November 2017
Resolved
while onboard MI observed signs of excessive leakage from #2 cargo pump PORT & STBD. pumps were not in operation at time observed but hsowed spray and and excessive amounts of cargo inside the containment. Prior to use during cargo operations make repairs to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2017
Resolved 20 November 2017
Resolution: Vessel rep provided shipyard report attesting to the condition of old packing and the installation of new packing.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 15 November 2017
Resolved
Aft PORT side void atmosphere was tested for explosive gases. Readings taken by onboard portable gas detector were 2% LEL. Additionally hose provided onbaord was of insufficient length for size of void/tank being tested. Vessel authorized transit approx 80 miles down river to Buck Kreihs repair facility. Vsl shall supply Marine Chemist with attendance of CG MI for further testing. Tanks to be closed and logged closed 2 hours prior to atmoshpere testing.
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Marine chemist tested all voids. Verified safe atmosphere.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 October 2017
Resolved
both smoke detectors in the berthing and galley area are inoperable. Repair or replace. 46 CFR 32.40-60(a)
Due 17 October 2017
Resolved 17 October 2017
Lifesaving › Immersion Suits › General
Issued 17 October 2017
Resolved
waterlights on 03 immerision suits expired. Replace.
Condition: Improper/Lack of Maintenance
Due 17 October 2017
Resolved 17 October 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 October 2017
Resolved
Repair junction located in aft port housing in thermal fluid heater room. Box is hold and wasted exposing wiring inside. 46 CFR 111.01-1(a)(2)
Due 31 October 2017
Resolved 24 October 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 October 2017
Resolved
Clean all dryer lint behind stackable laundy unit. Lint is excessive and creating a fire hazard.
Condition: Improper/Lack of Maintenance
Due 17 October 2017
Resolved 17 October 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 October 2017
Resolved
E-lighting lantern located in crew berthing inoperable. Repair or replace.
Condition: Improper/Lack of Maintenance
Due 17 October 2017
Resolved 17 October 2017
Deck/Cargo › Holds/Tanks › Hatch
Issued 21 March 2017
Resolved
Multiple cargo hatch access covers were found with severe corrosion and lack of satisfactory knife edge or inability to be watertight. Make repairs and prove all cargo hatch covers can be sealed properly. 46 CFR 32.60-40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Holds/Tanks › Ullage
Issued 21 March 2017
Resolved
Multiple Cargo tank sounding ulleges were found not to be vapor or watertight due to inadequate closer, gaskets or wastage on the knife edge. Make repairs and prove all cargo tank ulleges can be sealed properly. 46 CFR 32.60-40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 21 March 2017
Resolved
Multiple Cargo handling valves and stems were found to have severe necking corrosion and inadequate valve packing. Renew valve stems and repack valves where insufficient. 46 CFR 32.60-40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Ballast › Valves
Issued 21 March 2017
Resolved
Multiple ballast handling valves and stems were found to have severe necking corrosion and inadequate valve packing. Renew valve stems and repack valves where insufficient. 46 CFR 31.10-21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Construction/Loadline › Structures › Manhole
Issued 21 March 2017
Resolved
7. Multiple ballast hatch access covers were found with severe corrosion and lack of satisfactory knife edge or inability to be watertight. Make repairs and prove all cargo hatch covers can be sealed properly. 46 CFR 42.09-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Construction/Loadline › Structures › Manhole
Issued 21 March 2017
Resolved
Multiple void hatch access covers were found with severe corrosion and lack of satisfactory knife edge or inability to be watertight. Make repairs and prove all cargo hatch covers can be sealed properly. 46 CFR 42.09-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 March 2017
Resolved
Handrails cables around mooring bits were found disconnected and in disrepair. Renew handrail cables and connection points were missing. 46CFR 32.02-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Construction/Loadline › Structures › Deck Plating
Issued 21 March 2017
Resolved
Gauge tank top under all deck houses, and deck were indicated on the attached sheet. Gauging should include a 2'x2' grid with additional shots for deep pits. The gauging should be conducted with Coast Guard attendance. 46 CFR 31.10-21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Ballast › Vents
Issued 21 March 2017
Resolved
Multiple tank vent flame screens were inadequately supported and were no longer effective. Make repairs to flame screen covers/brackets where is disrepair. 46 CFR 32.55-45
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 21 March 2017
Resolved
Cargo pump shaft seals are not vapor tight when penetrating the cargo pump prime mover house. Either make all equipment within the house intrinsically safe or make all cargo pump shaft gasket vapor tight. 46CFR 32.50-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2017
Resolved
Cargo pump shaft guards were found corroded and inadequately supported. Renew cargo pump shaft guards where in disrepair. 46 CFR 32.02-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 21 March 2017
Resolved
Renew inoperable P/V valves at 2S and 3P, bench test all other P/V valves to prove operation. 46 CFR 32.55-25
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Electrical › Electric Supply System (service) › Cable
Issued 21 March 2017
Resolved
Electrical wire runs were found in disrepair and potential electrical hazard. Replace wire shielding and junctions to prevent chaffing. Ensure all wire runs within hazardous zones are intrinsically safe. 46 CFR 111.01-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 21 March 2017
Resolved
Remote shut-down cables were found slack and unsupported. Prove operation of emergency shut-downs on cargo pumps. 46 CFR 32.50-35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Operations/Management › Pollution › Control of Discharge of Oil
Issued 21 March 2017
Resolved
Hydraulic leak found under stbd crane. Make repairs and prove operation. 46 CFR 31.10-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Construction/Loadline › Structures › Deck Plating
Issued 21 March 2017
Resolved
Submit repair proposal to fix hole in the 8P tank top. 46 CFR 42.09-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2017
Resolved
Vessel must complete vessel COI renewal, credit dry-dock, ISE, and CTIE. 46 CFR 31.05-10 & 46 CFR 31.10-21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2017
Resolved
Submit an application for inspection and proposal on completing dry-dock, ISE, and CTIE. or Transfer barge into an out of commission/laid up status by removing all cargo residues and maintain the vessel in a gas free condition. 46 CFR 31.01-1 (b)
Due 31 March 2017
Resolved 17 October 2017
Construction/Loadline › Structures › Superstructure
Issued 20 January 2017
Resolved
Submit repair proposal to fix hole bulkhead void under aft deck house. 46 CFR 32.60
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2017
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 13 June 2016
Resolved
Technician unable to test overspeed device on No. 2 ship service generator; Replace or repair overspeed device and test in the presence of USCG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 17 June 2016
Resolution: Overspeed device on No. 2 ship service generator repaired by service technician; test sat.
Engineering › Diesel Engine (auxiliary) › Block
Issued 13 June 2016
Resolved
Technician unable to test lubricating pressure switch on No. 1 ship service generator; Replace lubricating pressure switch and test in the presence of USCG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 17 June 2016
Resolution: Lubricating pressure switch on No. 1 ship service generator replaced by technician; test sat.
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 June 2015
Resolved
Prior to traveling on an international route, must have valid IOPP & IAPP onboard. Certificates onboard barge have no endorsements.
Action required: 705 - Other - as specified
Resolved 17 July 2015
Deck/Cargo › Cargo Heating › General
Issued 15 June 2015
Resolved
Prior to carrying grade E cargoes that require thermal fluid heater, must operationally test it in the presence of the attending Coast Guard marine inspector within 30 days. Test could not be conducted due to the nature of the cargo onboard.
Action required: 705 - Other - as specified
Due 14 July 2015
Resolved 20 July 2015
Resolution: Barge isolated Thermal Fluid Heater, note was put into MISLE about testing the Thermal Fluid Heater prior to use or at next drydock whichever comes first in the presence of the Coast Guard.
Electrical › Electric Generation Source (service) › Generator
Issued 15 June 2015
Resolved
Each generator prime mover must have overspeed device independent of normal operating governor. Overspeed test could not be performed on generator #2, must prove operation to attending Coast Guard inspector.
Action required: 705 - Other - as specified
Due 29 June 2015
Resolved 23 June 2015
Resolution: Witnessed operational test.
Electrical › Electric Generation Source (service) › Generator
Issued 15 June 2015
Resolved
Each generator prime mover must shutdown automatically upon loss of lube oil. Aux generator did not. Must prove proper operation to the attending Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 29 June 2015
Resolved 23 June 2015
Resolution: Witnessed operational test.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 June 2015
Resolved
On switchboard must have working gauges. On barge some gauges did not work. Reverse power relay was not conducted. Must repair gauges and test according to attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 14 July 2015
Resolved 20 July 2015
Construction/Loadline › Hull › Double Hull
Issued 4 June 2015
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of ABS. Crew onboard discovered a 12" x 1.5" hole on the port side of the bow void, approx. 9' above the waterline. Barge is authorized completion of current cargo discharge and must then make permanent repairs to the satisfaction of Class
Due 19 June 2015
Resolved 29 June 2015
Resolution: Received ABS report attesting to proper repairs of the port bow void.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 June 2014
Resolved
Each Generator prime mover must have an overspeed device independent of normal operating governor as well as shut down automatically upon loss of lube oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 7 July 2014
Lifesaving › Lifebuoys › Serviceable
Issued 19 June 2014
Resolved
Replace all retro reflective tape on all life rings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2014
Resolved 19 June 2014
Operations/Management › Pollution › Control of Discharge of Oil
Issued 19 June 2014
Resolved
Replace two discharge of oil signs at ballast pump rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 8 July 2014
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 19 June 2014
Resolved
Repair machinery guard at stbd ballast pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 15 July 2014
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 19 June 2014
Resolved
Replace battery cables on cargo pumps #2,#3,#4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 21 July 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 September 2013
Resolved
A small crack was found on the #1 transverse bulkhead iwo the #1 cargo tank and stbd forward peak void. The crack is located on a weld approx 4 feet inboard from the side shell, along the 4th (from the bottom) longitudinal bulkhead stiffener and where the fwd void access ladder's support bracket attaches to the #1 transverse bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2013
Resolved 28 September 2013
Resolution: Witnessed satisfactory air test and visual inspection of repairs.
Deck/Cargo › Cargo Stowage › General
Issued 13 August 2013
Resolved
Transverse bulkhead no. 1 in forward Stbd void on weld seam of bulkhead stiffener no. 5 counting from bottom plating up. Make permanent repairs to forward bulkhead of the #1 stbd cargo tank. Repairs shall be to the satisfaction of the attending surveyor or CG inspector & prior to loading tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2013
Resolved 9 September 2013
Resolution: Two (2) inserts of size 77 in X 39 in and 57 in X 30 in were made in suspect area. In addition, repairs to
the hatch and adjacent hatch coaming of size 42 inch X 42 was made due to wastage of original
coaming. ABS surveyor satisfied with all repairs.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 June 2013
Resolved
Eliminate excessive oil leaks on #2 generator and mitigate oil on exhaust lagging to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 8 July 2013
Resolved 3 July 2013
Resolution: Verified that #2 Generator was operating properly and lagging was replaced. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 1 May 2012
Resolved
PROVIDE EXISTING APPROVED ELECTRICAL PLANS FOR THE HOSE CRANE MOTOR CIRCUIT -OR- PROVIDE AS INSTALLED APPROVED ELECTRICAL PLANS SHOWING ADEQUACY OF NEWLY INSTALLED CRANE MOTOR IAW 46 CFR 31.10-25.
Action required: 705 - Other - as specified
Resolved 29 May 2012
Resolution: RECEIVED ELECTRICAL LOAD ANALYSIS SHOWING ADEQUACY OF NEWLY INSTALLED CRANE MOTOR.
Construction/Loadline › Structures › Deck Plating
Issued 1 May 2012
Resolved
PROVIDE EXISTING APPROVED HYDRAULIC PLANS AND APPROVAL LETTER FOR THE HOSE CRANE -OR- PROVIDE EXISTING PLANS TO USCG MSC OR ABS FOR APPROVAL IAW 46 CFR 31.10-25. UPON APPROVAL, PROVIDE APPROVAL LETTER TO OCMI FOR VERIFICATION.
Action required: 705 - Other - as specified
Resolved 29 May 2012
Resolution: RECEIVED EXISTING APPROVED HYDRAULIC PLANS.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 April 2012
Resolved
Repair & test pinhole leak on cargo pipeline located in way of the #4 cargo pump valve & forward valve upstream of the transverse pipeline to satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2012
Resolution: New cargo piping was installed and tested satisfactorily.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2012
Resolved
PROVIDE EXISTING APPROVED ELECTRICAL PLAN FOR THE PORT AND STARBOARD CARGO HOSE CRANE INSTALLATION TO [name withheld].
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 3 May 2012
Resolution: Re-issuing CG-835 with different verbeage after discussing the issue with POC.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 17 March 2012
Resolved
PROVIDE 2 CONTAINMENT PLUGS FOR P & S FORWARD DEEP WELL CARGO PUMP CONTAINMENT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2012
Resolution: Observed 2 containment plugs installed via photograph.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 17 March 2012
Resolved
VESSEL TO REMAIN UNMANNED UNTIL ABS CLEARS PORT AFT INBOARD GENERATOR OPERATIONS & THE MANNED LOADLINE CERTIFICATE IS ISSUED.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 1 May 2012
Resolution: Received ABS Surveyor''s report attesting to the proper installation and operation of new port aft inboard generator. Manned loadline certificate has been issued.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 March 2012
Resolved
PROVIDE OPERABLE YELLOW FLASHING NAVLT PER COLREGS RULE 24 PRIOR TO PUSHING BARGE AHEAD INLAND ON WATERS PER 33 CFR 81-90.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 16 April 2012
Resolution: RECEIVED PICTURE FROM POC SHOWING OPERABLE YELLOW FLASHING NAVIGATION LIGHT ON BOW.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 17 March 2012
Resolved
COMPLETE ASSEMBLY OF ACCOMMODATIONS AND GALLEY TO MEET 46 CFR 32.57, 46 CFR 32.57-10(d)(8), (9) AND 46 CFR 32.60-25 PRIOR TO CREW OCCUPYING.
Action required: 705 - Other - as specified
Due 30 November 2012
Resolved 21 September 2012
Resolution: RCVD Approval letter from MSC stating that installing CG approved materials where previous combustible materials were installed is a sufficient means of complying with the regulations mentioned above.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 17 March 2012
Resolved
LABEL AIR RECEIVER WITH MAWP OF 150 PSI AND PROVIDE LABEL INFORMATION TO [name withheld]. PROVIDE PHOTO OF AIR RECEIVER WITH LEGIBLE LABEL TO PROVE SAME DESIGN.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 16 April 2012
Resolution: RECEIVED PICTURE OF AIR RECEIVER STENCILED WITH MAWP OF 150 PSI. ALSO PROVIDED LABEL INFORMATION TO [name withheld].
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2012
Resolved
REPLACE FLUORESCENT LIGHT COVER IN STBD FWD CARGO PUMP HOUSE.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 16 April 2012
Resolution: RECEIVED PICTURE FROM POC SHOWING FLUORESCENT LIGHT COVER IN STBD FWD CARGO PUMP HOUSE PROPERLY REPLACED.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 17 March 2012
Resolved
FURTHER INVESTIGATE, REPAIR/REPLACE LINKAGE/DIRECTIONAL VALVE FOR CREEP OF ANCHOR WINDLASS CAPSTAN. DEMONSTRATE FURTHER OPERATION TO CG INSPECTOR.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 16 April 2012
Resolution: RECEIVED PICTURE FROM POC VERIFYING REPLACEMENT OF LINKAGE/DIRECTIONAL VALVE OF ANCHOR WINDLASS CAPSTAN. POC STATES THAT WINDLASS IS NOW PROPERLY OPERATING.
Construction/Loadline › Structures › Deck Plating
Issued 17 March 2012
Resolved
PROVIDE GAUGE REPORT AND SHIPYARD DETAILS FOR STEEL WORK PERFORMED DURING JAN-MAR 2012 YARD PERIOD TAMPA, FLORIDA TO [name withheld].
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 17 March 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 March 2012
Resolved
REPLACE 100 FEET OF BUOYANT LINE ON STBD FWD RING BUOY PER 46 CFR 199. 70(3)(i).
Action required: 705 - Other - as specified
Resolved 17 March 2012
Resolution: OBSERVED NEW BLACK UV LINE BEING INSTALLED ON RING BUOY.
Construction/Loadline › Structures › Deck Plating
Issued 17 March 2012
Resolved
PROVIDE CG OR ABS NVIC 10-82 APPROVED PLANS FOR NEW INSTALLATION OF HYRAULIC OIL SYSTEM AND ELECTRICAL COMPONENTS FOR PORT AND STARBOARD CARGO HOSE CRANES.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 3 May 2012
Resolution: Re-issuing CG-835 with different verbeage after discussing the issue with POC.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 March 2010
Resolved
Conduct analysis of insulation located in the forecastle to determine composition, If the material is asbestos remove from space.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Resolution: Cleared requirement after reviewing photographs submitted by Bouchard Port Engineer. Photos show sat removal of pipe & insulation (cut away from inside forecastle space). M.H. Simpson, GS-13 [name withheld]/Galveston.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 March 2010
Resolved
Make repairs to lighting fixture\wiring in forecastle. Ensure all lighting operates as designed and is properly secured. All wiring must be properly run and secured.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 25 March 2010
Resolution: Space lighting was repaired, lighting units properly attached to bulkheads. All exposed wiring correctly run and secured.
Engineering › Generator (propulsion-electric) › Switch
Issued 25 March 2009
Resolved
Replace tachometers on both generators.
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 14 May 2009
Resolution: Tachometers replaced satisfactorily,
Electrical › Electric Generation Source (service) › Generator
Issued 12 March 2008
Resolved
Condition: Unknown
Due 13 April 2008
Resolved 11 April 2008
Resolution: Received pictures from vessel rep verifying that tachometer had been installed on both generators.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 12 March 2008
Resolved
Paint/mark vapor pipeline near manifold.
Due 13 April 2008
Resolved 11 April 2008
Resolution: Received pictures from vessel''s rep verifying that the vapor pipeline had been painted and marked IAW regulations.
Construction/Loadline › Hull › Hull Plating
Issued 17 December 2007
Resolved
Crop out and renew wasted deck plate beneath living quarters.
Condition: Unknown
Due 19 December 2007
Resolved 19 December 2007
Resolution: Air test completed satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 17 December 2007
Resolved
Renew wasted deck flooring in living quareters.
Condition: Unknown
Due 19 December 2007
Resolved 20 December 2007
Resolution: ABS witnessed satisfactory installation.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 1 March 2006
Resolved
Clean or renew flame screens as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 1 March 2006
Resolved
Provide proof of all cargo pump engine emergency shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 March 2006
Resolved
Ensure all lifebuoys meet requirements of 46CFR199.70.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 1 March 2006
Resolved
Provide proof of proper operation and all safety mechanisms on each service generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 March 2006
Resolved
Label all switches on switchboard on the No. 2 starboard pump house.
Condition: Improper Installation
Due 2 April 2006
Resolved 2 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 1 March 2006
Resolved
MAKE PERMANENT REPAIR TO FRACTURE IN #6 CARGO TANK TOP. MAINTAIN TEMPORARY 10" DOUBLER PLATE REPAIR.
Due 17 January 2007
Resolved 28 December 2006
Resolution: Permanent repairs completed while vessel was in the shipyard.
Deck/Cargo › Cargo Heating › General
Issued 11 April 2005
Resolved
Operationally test the Thermal Fluid Heater in the presence of an attending Marine Inspector. Test could not be conducted due to the nature of the cargo curently onboard.
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 12 May 2005
Resolution: Witness test conducted By Green Marine, all sat.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 November 2004
Resolved
BARGE IS NOT TO LOAD CARGO UNTIL ATTENDED BY USCG MARINE INSPECTOR (HOLE IN DECK INTO STARBOARD #6 CARGO TANK) VESSEL HAS CONDITION OF CLASS TO DISCHARGE CARGO.
Action required: 705 - Other - as specified
Resolved 22 December 2004
Resolution: AIR TEST COMPLETE ON INSERT
Stability › Watertight Integrity › General
Issued 11 November 2004
Resolved
KEEP ALL WTD CLOSE WHILE UNDERWAY TO MIAMI AND TO TAMPA FOR DRYDOCK
Due 19 November 2004
Resolved 23 November 2004
Resolution: VESSEL ARRIVED SAFELY FOR DRYDOCK
Engineering › Diesel Engine (auxiliary) › Valve, Pilot (air start)
Issued 15 April 2003
Resolved
DOCUMENTATION OF ANNUAL TESTING OF RELIEF VALVE NOT PROVIDED. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 11 November 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 15 April 2003
Resolved
EXTENTION CORD WIRED INTO WATER PUMP IN GALLEY. TO BE REPLACED WITH APPROVED MARINE CABLE. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 12 May 2005
Resolution: Cleared Legacy item.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 January 2001
Resolved
CROP AND RENEW HANDRAILS STARBOARD AFT SIDESHELL AT NEXT DRYDOCK WHICH IS TENTATIVELY SCHEDULED FOR 31 MAY 01.
Condition: Unknown
Due 31 May 2001
Resolved 30 May 2001
Construction/Loadline
Issued 25 June 1999
Resolved
VESSEL TO MAKE PERMANENT REPAIRS TO STBD AFT QUARTER AND SIDE SHELL DURING NEXT SCHEDULED DRYDOCK IN JULY 1999.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Unknown
Issued 25 June 1999
Resolved
REPAIRS TO STBD AFT QUARTER SHALL BE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Deck/Cargo
Issued 8 January 1999
Resolved
PROCURE TEST/CALIBRATION GAS FOR THE COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 8 February 1999
Resolved 14 January 1999
Documentation
Issued 8 January 1999
Resolved
PROVIDE PROOF THAT COMPANY/BARGE IS PRESENTLY ENROLLED IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 8 February 1999
Resolved 14 January 1999
Electrical
Issued 8 January 1999
Resolved
REINSTALL RPM GAUGE FOR VESSEL GENERATOR.
Condition: Unknown
Due 8 February 1999
Resolved 14 January 1999
Lifesaving
Issued 8 January 1999
Resolved
MOUNT LIFE BOUYS OUTSIDE OF DECKHOUSE.
Condition: Unknown
Due 8 February 1999
Resolved 14 January 1999
Deck/Cargo
Issued 17 January 1997
Resolved
PROVE PROPER OPERATION OF ALL EXHAUST VENTILATION HOODS, HYDRAULICALLY AND WEATHERTIGHT.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Accommodation/Occupational Safety
Issued 17 January 1997
Resolved
INSTALL SINK IN CREW'S RESTROOM.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Deck/Cargo
Issued 17 January 1997
Resolved
PROVIDE PLAN FOR REMOVAL OF STRIPPING PIPE.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Engineering
Issued 19 January 1995
Resolved
Replace leaking pressure relief valve on air compressor tank. New valve must be ASME coded "U" or "UV" (stamped) and set at less than or equal to 200psig.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 19 January 1995
Resolved
Do maintenance on all watertight doors and hatches; renew gasket material, de-rust knife edges, free up all dogging mechanisms.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Accommodation/Occupational Safety
Issued 19 January 1995
Resolved
Replace wasted escape scuttle hatch over crew berthing. Temporary repairs made to hinges this date.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Engineering
Issued 17 November 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Navigation
Issued 17 November 1993
Resolved
PAINT NAVIGATION LIGHT SCREENS STBD SIDE AND STERN FLAT BLACK.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
STENCIL HYDRO TEST DATES ON CARGO PIPE LINES AND TRANSFER HOSES.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Electrical
Issued 17 November 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO #1 PORT CARGO HATCH COVER WHERE TEMPORARY REPAIR HAS BEEN MADE.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO ANCHOR RIDING PAWL.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Construction/Loadline
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO FWD BILGE PUMP DISCHARGE OUTLET WHERE WASTED ON DECK.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
RESTENCIL LIFERAFT LOCATION AND CAPACITY.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Electrical
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL WIRING IN FORCASTLE WHERE SPLICE IS EVIDENT.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO MIDSHIP PORT CARGO PUMP EMERGENCY SHUTDOWN PRIOR TO ANY DISCHARGE OF CARGO.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
PROVIDE LIFERAFT INSTRUCTION PLACARD TO BE PERMANENTLY AFFIXED AT LIFERAFT STATION.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON PLACE RETROREFLECTIVE TAPE ON ALL RING BOUYS.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Engineering
Issued 17 November 1993
Resolved
PROVIDE USCG APPROVED AUTOMATION TESTING PROCEDURES FOR THERMAL FLUID HEATER, PRIOR TO USING HEATER.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Construction/Loadline
Issued 17 November 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
PROVIDE PROTECTIVE BOXES FOR ALL BATTERIES.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
REPAIR OR REPLACE PROTECTIVE GUARD ON STBD AFT CARGO PUMP, OUTSIDE PUMP HOUSE.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO WINCH SWITCH ASSEMBLY WHERE CONTROLS ARE BROKEN.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 17 November 1993
Resolved
REPLACE FLAME SCREEN ON P/V VALVE AT #3 PORT CARGO TANK.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Lifesaving
Issued 17 November 1993
Resolved
REPLACE REJECTED LIFEJACKETS.
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Construction/Loadline
Issued 17 November 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Engineering
Issued 17 November 1993
Resolved
REPLACE AIRLINE FROM BLOWER TO BURNER ON THERMAL FLUID HEATER, PRIOR TO USING HEATER.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Electrical
Issued 17 November 1993
Resolved
REMOVE DEAD-END WIRING ON GENERATOR SETS.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 5 February 1993
Resolved
STENCIL SAFE WORKING LOAD ON P & S DECK CRANE.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Deck/Cargo
Issued 5 February 1993
Resolved
#5 HYDRO TEST, OR MAKE AVAILABLE FOR INTERNAL EXAM AIR RECEIVER IN GENERATOR ROOM.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Electrical
Issued 5 February 1993
Resolved
PROVE PROPER OPERATION OF GENERATOR ROOM EMERGENCY LIGHTING.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Electrical
Issued 5 February 1993
Resolved
PROVE PROPER OPERATION OF GENERATOR REVERSE POWER PROTECTION.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Deck/Cargo
Issued 5 February 1993
Resolved
PROVE PROPER OPERATION OF BOILER ROOM VENTILATION BLOWER.
Condition: Unknown
Due 5 February 1993
Resolved 5 February 1993
Deck/Cargo
Issued 22 January 1991
Resolved
STENCIL CARGO PIPE WITH THE TEST PRESSURE AND DATE TESTED.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Fire Fighting
Issued 22 January 1991
Resolved
STENCIL THE FORWARD AND AFTER MAIN DECK B-V FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Deck/Cargo
Issued 22 January 1991
Resolved
REPAIR AND PROVE OPERATION OF THE THERMAL FLUID HEATER AUDIBLE ALARM.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Documentation
Issued 22 January 1991
Resolved
AMEND THE OIL TRANSFER PROCEDURES TO REFLECT CURRENT CONFIGURATION OF THE BARGE (EG. NO BOW THRUSTER ENGINE, NO BALLAST TIES OR SEACHESTS.)
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Deck/Cargo
Issued 13 December 1988
Resolved
RENEW/REPAIR PV VALVES ON ALL CARGO TANKS. THE BARGE IS RESTRICTED TO CARRIAGE OF CLASS "D" AND BELOW UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Deck/Cargo
Issued 13 December 1988
Resolved
CONDUCT ANNUAL TEST OF ALL SAFETYS AND ALARMS FOR THE THERMAL FLUID HEATER.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Navigation
Issued 13 December 1988
Resolved
REPLACE BATTERY OPERATED NAVIGAITON LIGHTS WITH APPROVED 110V INSTALLED LIGHTS THAT MEET THE COLLISION REGULATIONS.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 4 December 1988
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AREA IN WAY OF THE PORT AND CENTER FORWARD RAKE COMPARTMENTS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING CARGO.
Condition: Unknown
Due 4 December 1988
Resolved 4 December 1988
Deck/Cargo
Issued 23 May 1988
Resolved
MAKE PERMANENT REPAIRS TO #1 CARGO PUMP BLEED LINE.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Deck/Cargo
Issued 23 May 1988
Resolved
INSTALL PROPER PACKING IN #3 AND 4 CARGO PUMPS.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Navigation
Issued 23 May 1988
Resolved
REINSTALL BATTERY CABLING AND TEST BOW THRUSTER.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Navigation
Issued 23 May 1988
Resolved
REPAIR LEAKS IN EXHAUST PIPE FROM BOW THRUSTER ENGINE.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Construction/Loadline
Issued 23 May 1988
Resolved
REPLACE FLEXIBLE SECTION OF SUBMERSIBLE PUMP DISCHARGE LIN LOCATED IN FORWARD BILGE PUMP ROOM.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Construction/Loadline
Issued 23 May 1988
Resolved
REPLACE AND PROPERLY WELD THE ROUGHCUT MANHOLE IN THE AFT BULKHEAD OF THE FORWARD BILGE PUMP ROOM TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Deck/Cargo
Issued 2 November 1987
Resolved
MAKE PROPER REPAIRS TO FORWARD PORT DROP LINE LEAKING AT WELD TO FLANGE UNTIL REPAIRS ARE MADE, LINE IS NOT TO BE USED.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Deck/Cargo
Issued 6 January 1987
Resolved
PROVE PROPER OPERATION OF #1 CARGO PUMP EMERGENCY SHUTDOWN. SHUTDOWN NOT TESTED BECAUSE PUMP IS INOPERATIVE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 6 January 1987
Resolved
REPLACE WASTED MUFFLERS ON ALL CARGO PUMP EXHAUSTS.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Electrical
Issued 6 January 1987
Resolved
INSTALL BLANKS IN OPENINGS IN CIRCUIT BREAKER PANEL BEHIND #4 CARGO PUMP ENGINE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Fire Fighting
Issued 6 January 1987
Resolved
PROVIDE AIR BOTTLE FOR SELF-CONTAINED BREATHING APPARATUS WITH CURRENT HYDROSTATIC TEST DATE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 6 January 1987
Resolved
PROVIDE WARNING SIGN IN ACCORDANCE WITH 46 CFR 35.30-1 (B) VISIBLE FROM THE STARBOARD SIDE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Engineering
Issued 31 October 1986
Resolved
IN ACCORDANCE WITH 46 CFR 61.30-10 CONDUCT A 1.5 TIMES MAWP HYDROSTATIC TEST OF THE FIRED THERMAL FLUID HEATER.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Electrical
Issued 12 June 1986
Resolved
REPAIR BROKEN DECK LIGHTS.
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Deck/Cargo
Issued 12 June 1986
Resolved
COMPLETE TESTING OF AND MARKING OF OIL TRANSFER HOSES.
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Accommodation/Occupational Safety
Issued 15 February 1985
Resolved
VESSELS MSD IS INOPERATIVE/ NYCMI BOARDING ON 13DEC84 ISSUED A VIOLATION IDENT D-1/ TO BE CORRECTED PRIOR TO 16JAN85. MSD STILL INOP.
Condition: Unknown
Due 26 October 1985
Resolved 15 February 1985
Deck/Cargo
Issued 17 October 1984
Resolved
REPLACE BROKEN SIGHT GLASS AND BROKEN SIGHT GLASS FRAME ON THERMAL FLUID HEATER.
Condition: Unknown
Due 17 October 1984
Resolved 17 October 1984
Unknown
Issued 17 October 1984
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE INSTALLED MARINE SANITATION DEVICE. ACTUAL COMPLAINCE DATE 16JAN85
Condition: Unknown
Due 17 October 1984
Resolved 17 October 1984
Deck/Cargo
Issued 17 October 1984
Resolved
REPLACE OR REPAIR BROKEN FORCED AIR FLEX HOSE TO THERMAL FLUID HEATER.
Condition: Unknown
Due 17 October 1984
Resolved 17 October 1984
Deck/Cargo
Issued 17 October 1984
Resolved
PROVE PROPER OPERATION OF AUDIBLE AND VISUAL ALARMS ON THERMAL FLUID HEATER
Condition: Unknown
Due 17 October 1984
Resolved 17 October 1984
Unknown
Issued 9 November 1983
Resolved
CONDUCT HYDROSTATIC TEST OF THE THERMAL FLUID HEATER AND CONDUCT AN AUTOMATION TEST OF THE SAME.
Condition: Unknown
Due 9 November 1983
Resolved 9 November 1983