Records from 1993 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 51
12 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8372207
24 September 2025
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8240250
20 May 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8139618
8 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7903506
7 February 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7861907
4 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7799510
23 May 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7694573
25 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7459025
17 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7449917
12 May 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7179169
1 March 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7324450
2 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6966345
20 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6946798
10 June 2019
Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6713854
14 May 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6665188
23 April 2018
Administrative Inspection · Annual Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6397458
11 May 2017
Annual Inspection · Drydock Exam · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6119780
26 May 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5886300
12 May 2016
Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5872106
14 May 2014
Drydock Exam · Internal Structural Exam · Simplified Stability Test · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4856758
4 February 2012
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 4238815
15 September 2010
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3850378
10 October 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3344162
29 February 2008
Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 3165947
26 November 2007
Hull Examination · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3106081
6 September 2007
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3050387
18 September 2006
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2782080
22 August 2006
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2756138
28 July 2006
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2727359
11 October 2005
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2512164
15 September 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2488097
4 October 2004
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2216404
22 September 2004
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2203816
19 September 2003
MARPOL Annex V Examination · Periodic Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1899668
29 July 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1862778
9 October 2002
Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1724551
11 September 2002
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1670112
12 September 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384919
18 September 2000
Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382037
17 September 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410178
15 September 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461073
28 August 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368839
11 August 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368838
9 December 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113890
17 September 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1111713
17 September 1996
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1088529
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088470
2 August 1995
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 880100
18 July 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 865686
9 August 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1146483
19 July 1993
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399901
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 May 2026
Resolved
Provide documentation showing the fire fighting equipment has been inspected and maintained in accordance with NFPA 10 (annual servicing).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 22 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 May 2024
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. The manifolded bilge system and pump could not take suction from the forepeak or forward void. Prove proper operation of bilge system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 February 2024
Resolved
Received report vessel allided with concrete mooring dolphin and sustained damage to port hull at the sheer strake. Damage caused opening of the hull above the waterline. Submit repair proposal and repair to original scantling prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 27 June 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022
Resolved
Provide a valid FCC Safety Radiotelephony Certificate prior to operating more than 1,000 feet from shore.
Action required: 705 - Other - as specified
Resolved 27 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 May 2022
Resolved
Suitably insulate the piping on the port and starboard exhaust system where it exceeds 150 degrees fahrenheit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 June 2020
Resolved
Power take off for bilge pump in way of starboard engine is not adequately guarded. Submit plans for adequate guarding around dangerous machinery to the satisfaction of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2020
Resolved 26 June 2020
Resolution: Inspected guard installed around power take off for the bilge pump. The guard fully covers the wheel and other rotating machinery and is secured in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 June 2020
Resolved
Pilot house gauges for starboard engine intermittently power off and on. Ensure that gauges are properly functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2020
Resolved 26 June 2020
Resolution: Inspected newly installed starboard engine pilot house gauge. Gauge functions properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2020
Resolved
Exhaust breather pipes contained holes. Cut out old pipe and install new pipe to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2020
Resolved 22 May 2020
Resolution: New pipes welded sufficiently into place on both the port and starboard sides.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 10 June 2019
Resolved
Submit repair proposal for repairs of damages.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2018
Resolved
All fuel lines must be leak free. Return line connection fitting is slowly leaking in lazarett space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2018
Resolution: New 90* elbow installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 June 2018
Resolved
Make provisions to securely close supply ventilation to engine room. Closure devices not seating to secure air flow.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2018
Resolution: Closure devices repositioned and gaskets installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 June 2018
Resolved
Log fire fighting and man over board drills. Drills required quarterly or per 46CFR185.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2018
Resolution: Required drills logged.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 June 2018
Resolved
Provide up to date Coast Pilot and current tables for area of intend voyage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2018
Resolution: Publications onboard.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2016
Resolved
Provide repair proposal to make permanent repairs to all identified pitting on the port and starboard exterior hull (28 pits noted and welder to identify additional areas with the proper grinding tools).
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 18 May 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 May 2016
Resolved
Weld insert internally at both wet exhaust outlets as identified (internal weld were never completed on the aluminum exhaust outlets below the waterline).
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 20 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 12 May 2016
Resolved
Renew port engine inboard aft engine mount (cracked completely through).
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 20 May 2016
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 May 2016
Resolved
Provide vent closures for forward engine room vents.
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 20 May 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 September 2006
Resolved
Make watertight bulkhead penetrations watertight.
Due 20 September 2006
Resolved 25 August 2010
Communications › Alarms/Indicators › High Water Alarm
Issued 15 September 2005
Resolved
Prove proper operation of bilge high water alarm in way of #2 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Documentation › Certificates/Documents › FCC SSL
Issued 15 September 2005
Resolved
Provide FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 11 October 2005
Fire Fighting › Fire Main
Issued 11 September 2002
Resolved
Provide 3 fire buckets. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 18 September 2002
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 September 2002
Resolved
Renew first aid kit in accordance with 46 CFR 160 & 184 LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 18 September 2002
Resolution: Corrected
Engineering › Fuel Oil Service System
Issued 11 September 2002
Resolved
Provide plugs for RACOR flame bowls. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 29 July 2003
Resolution: Valves were removed and threaded plugs were installed.
Documentation › Certificates/Documents
Issued 11 September 2002
Resolved
Post all pages of COI & Stability letter LEGACY COMPONENT DESC: COI & Stability Letter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 18 September 2002
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 September 2002
Resolved
Attach a corrosion-resistant clip to waterlight lanyard.
Action required: 705 - Other - as specified
Due 11 October 2002
Resolved 11 September 2002
Resolution: Corrected on the spot.
Unknown
Issued 17 September 1999
Resolved
Provide proof of User-Fee payment.
Condition: Unknown
Due 17 September 1999
Resolved 7 October 1999
Construction/Loadline
Issued 17 September 1999
Resolved
Re-mount #2 hold high water alarm.
Condition: Unknown
Due 17 September 1999
Resolved 7 October 1999
Accommodation/Occupational Safety
Issued 17 September 1999
Resolved
Re-mount circulating pump for A/C unit in #2 Hold.
Condition: Unknown
Due 17 September 1999
Resolved 7 October 1999
Construction/Loadline
Issued 17 September 1999
Resolved
Repair stbd engine bilge pump.
Condition: Unknown
Due 17 September 1999
Resolved 7 October 1999
Electrical
Issued 11 August 1998
Resolved
Repair/renew explosive proof fixture in after steering compartment.
Condition: Unknown
Due 28 August 1998
Resolved 29 August 1998
Electrical
Issued 11 August 1998
Resolved
Replace wire connections in main hold w/crimp-style connectors. Complete in drydock period scheduled for SEP98.
Condition: Unknown
Due 30 September 1998
Resolved 16 September 1998
Lifesaving
Issued 11 August 1998
Resolved
Properly mark stowage locations of PFDs.
Condition: Unknown
Due 28 August 1998
Resolved 29 August 1998
Lifesaving
Issued 11 August 1998
Resolved
Properly display PFD Donning procedures.
Condition: Unknown
Due 28 August 1998
Resolved 29 August 1998
Electrical
Issued 11 August 1998
Resolved
Repair/renew exposed wiring on the port side, main deck, lighting fixture.
Condition: Unknown
Due 28 August 1998
Resolved 29 August 1998
Documentation
Issued 17 September 1997
Resolved
Provide a current FCC Safety Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Construction/Loadline
Issued 2 August 1995
Resolved
PIOR TO RECEIVING CREDIT FOR DRYDOCK EXAMINATION, MAKE LAZARETTE COMPARTMENT AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Engineering
Issued 2 August 1995
Resolved
PROPERLY SECURE ENGINE THROTTLE CABLES IN THE MAIN COMPARTMENT.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Lifesaving
Issued 2 August 1995
Resolved
INSTALL PROPER WEAK LINK ON BUOYANT APPARATUS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Lifesaving
Issued 2 August 1995
Resolved
PROPERLY LASH AND SECURE OARS TO THEIR RESPECTIVE BUOYANT APPARATUS.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Electrical
Issued 2 August 1995
Resolved
PROPERLY SPLICE WIRES UNDERNEATH BRIDGE CONSOLE WHERE THEY ARE TWISTED TOGETHER.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Electrical
Issued 2 August 1995
Resolved
LABEL PANEL BOARD AND BREAKERS LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Lifesaving
Issued 2 August 1995
Resolved
PROVIDE ONE ADDITIONAL, VALID, AND COAST GUARD APPROVED HAND RED FLARE PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 03 AUGUST 1995.
Condition: Unknown
Due 2 August 1995
Resolved 10 August 1995
Documentation
Issued 18 July 1994
Resolved
PROVIDE COPY OF VALID FCC RADIOTELEPHONY CERTIFICATE. UNTIL SUCH TIME, THEVESSEL IS LIMITED TO OPERATION NOT MORE THAN 1000 FEET FROM LAND.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994