MAURY USCG vessel records Sign in
← All vessels

SERENITY

SERENITY is a 1998 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1998, most recently in June 2026, along with 44 deficiencies and 1 casualty investigation in 2012.

Records from 1998 to 2026. Most recent: inspection, 24 June 2026.

Built
1998
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF6830
485599
Flag
UNITED STATES
367478260
Maury page id
psix-485599

Inspections, by type

…with no type recorded5
Years with a record 24 calendar years (1998–2026)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER BOATS INTNL · FT PIERCE FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6830MMSI 367478260 · active · voluntarily equipped · granted 8 January 2021, expires 5 February 2031
WCZ6688MMSI not assigned · expired · compulsorily equipped · granted 17 February 2000, cancelled 24 April 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LIL PRINCESS Passenger (Inspected) · MISLE 391418 · 1 March 2021 · activity 7324450SIERRA Passenger (Inspected) · MISLE 449468 · 1 March 2021 · activity 7324450ISLAND TIME Passenger (Inspected) · MISLE 1219537 · 1 March 2021 · activity 7324450

Inspection history · 43

24 June 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8412858
16 December 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8291606
17 December 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8049641
20 June 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7936546
16 January 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7850019
20 December 2022 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7616472
8 June 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7470684
7 December 2021 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7351040
1 March 2021 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7324450
15 December 2020 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7100738
24 June 2020 Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6953019
3 December 2019 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6866051
19 December 2018 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6586641
15 June 2018 Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6456429
12 June 2018 Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6441817
16 January 2018 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6345728
13 December 2016 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6057010
9 June 2016 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5901942
27 January 2016 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5802651
9 June 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4894327
3 July 2012 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4366234
14 June 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4343846
2 June 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4335865
22 December 2011 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4212524
29 January 2010 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3672378
29 January 2009 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3402206
26 June 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3248655
15 April 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3184784
15 June 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2962327
7 February 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2580939
16 May 2005 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2359157
23 February 2005 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2297817
19 January 2005 Drydock Extension · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2276654
10 February 2004 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 2004240
12 December 2003 Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1962404
10 January 2003 Re-Inspection · Drydock Extension · Hull Examination · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1725419
5 December 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1485691
11 January 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421997
11 February 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1463554
27 August 1999 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 1497749
24 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420113
8 December 1998 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381422
17 November 1998 Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375604

Deficiency record · 44

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2021 Resolved
Lifering is worn; replace as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 21 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew from electrical hazards. Wiring exposed on bow thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2021
Resolved 21 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 December 2021 Resolved
A vessel must carry up-to-date U. S. Coast Pilot and Coast Guard Light List. Current editions on baord are from 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 21 December 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2021 Resolved
Provide panoramic mirror as required by COI for manning reduction prior to operating only with master.
Action required: 705 - Other - as specified
Due 7 December 2021
Resolved 21 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 December 2019 Resolved
Replace light cover on light fixture in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: replaced light
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2019 Resolved
Replace worn/missing chaffing gear on wires on engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: replaced chaffing gear on wires
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2019 Resolved
Remove or cap off all dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 December 2019
Resolution: capped dead end wire
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 December 2018 Resolved
Demonstrate proper operation of engine room ventilation closure devices (space protected by an fixed gas extinguishing system). Port ventilation was seized in the open position and would be unable to contain fire extinguishing agent in the event of an engine room fire.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2018
Resolved 20 December 2018
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 December 2018 Resolved
Demonstrate operation of magnetic compass light. Vessel limited to daylight operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2019
Resolved 3 January 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2018 Resolved
Provide permanent type connectors to battery terminals, wing nuts are currently installed on 03 of 04 terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2019
Resolved 3 January 2019
01 - Certificates & Documentation › 013 - Documents › AIS test report
Issued 19 December 2018 Resolved
Post emergency instructions that address the following situations as per 46 CFR 185.510: Rough weather at sea, Man overboard, and Fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2019
Resolved 3 January 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 December 2018 Resolved
Provide manufacture date for Fireboy cylinder, if manufacture date is past 12 years old then cylinder must be hydrostatic tested or replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2019
Resolved 3 January 2019
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 June 2018 Resolved
Make fuel tanks ready to visually inspect. Remove FRP casing. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 19 July 2018
Resolution: New fuel tanks installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 June 2018 Resolved
Replace manual activation cable for fixed gas fire extinguishing system. Demonstrate proper operation for attending marine inspector. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 27 July 2018
Resolution: New cable installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 January 2018 Resolved
Prove proper operation of Fireboy shutdown and override function.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2018
Resolution: Installed new override switch and successfully tested override function.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 January 2018 Resolved
Provide audible and visual indicators for each high level high-water alarm.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 19 February 2018
Resolution: Installed audible and visual indicators for each high level alarm and conducted tests of each.
Construction/Loadline › Structures › Deck Plating
Issued 16 January 2018 Resolved
Make repairs to damaged areas on port side above the rub rail.
Action required: 705 - Other - as specified
Due 9 June 2018
Resolved 12 June 2018
Engineering › Bilge Water Management System › Pump
Issued 16 January 2018 Resolved
Renew submersible bilge pumps with pumps meeting the requirements of UL113.
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 19 February 2018
Resolution: Installed bilge pumps meeting the requirements of UL113.
Engineering › Steering Gear System › Actuator
Issued 13 December 2016 Resolved
Prove proper operation of emergency steering
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: Proved proper operation of emergency steering.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 December 2016 Resolved
Remove locking mechanism from hatch where PFDs are stowed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Removed locking mechanism
Communications › Alarms/Indicators › High Water Alarm
Issued 13 December 2016 Resolved
Properly label high level and automatic bilge pump indicators
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 21 December 2016
Resolution: Labeled all indicators
Engineering › Fuel Oil Service System › Piping
Issued 13 December 2016 Resolved
Renew flexible fuel hose from selector valve to strainer with approved hose
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 21 December 2016
Resolution: Renewed with copper tubing
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 13 December 2016 Resolved
Properly label stowage of portable fire extinguisher in forward compartment
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 21 December 2016
Resolution: Installed label to indicate portable extinguisher in compartment
Fire Fighting › Fire Bucket › Availability
Issued 13 December 2016 Resolved
Provide 03 fire buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Provieded additional fire bucket
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2016 Resolved
Post Certificate of Inspection.
Action required: 705 - Other - as specified
Due 27 February 2016
Resolved 16 February 2016
Resolution: Vessel posted all pages of the COI.
Documentation › Certificates/Documents › Stability Letter
Issued 27 January 2016 Resolved
Post Stability Letter.
Action required: 705 - Other - as specified
Due 27 February 2016
Resolved 16 February 2016
Resolution: Vessel posted all pages of the Stability Letter.
Engineering › Bilge Water Management System › Valve
Issued 27 January 2016 Resolved
Install positive shutoff valve at the submersible bilge hull penetration.
Action required: 705 - Other - as specified
Due 27 February 2016
Resolved 16 February 2016
Resolution: Vessel installed positive shutoff valves on all submersible bilge pump discharge lines. Vessel was not able to install the valves at the through hull due to inaccessability. Recommend vessel move valves and install access ports at next drydock.
Fire Fighting › Fire Bucket › Lanyard
Issued 15 April 2008 Resolved
Install lanyards of sufficient length to all fire buckets.
Due 22 April 2008
Resolved 15 April 2008
Engineering › Fuel Oil Service System › Valve, Control
Issued 15 April 2008 Resolved
Label valve positions on emergency fuel shutoff valves.
Due 22 April 2008
Resolved 22 April 2008
Construction/Loadline › Hull › Keel
Issued 23 February 2005 Resolved
Make satisfactory repairs to area of delamination noted in way of vessels keel.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 30 March 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 February 2005 Resolved
Make satisfactory repairs to transverse structural member (web) IWO port MDE longitudinal stringer at the attacthment point between the 2 structural members as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 30 March 2005
Engineering › Fuel Oil Service System › Piping
Issued 19 January 2005 Resolved
Ensure fuel supply piping meets the standards of 46 CFR 182.455. If flexible hose is used IAW 46 CFR 182.720, ensure hose meets SAE standard J1942.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 30 March 2005
Engineering › Bilge Water Management System › Pump
Issued 19 January 2005 Resolved
Permanently mount automatic bilge pump float switch in vessel transom.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 30 March 2005
Stability › Watertight Integrity
Issued 10 January 2003 Resolved
Replace or renew latches to hatch cover for lazarette not later than 09FEB03. LEGACY COMPONENT DESC: Hatch cover securing devices
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 13 January 2003
Resolution: Hatch needed new spring for dogging mechanism and lubrication. Observed operating properly by [name withheld].
Stability › Watertight Integrity
Issued 10 January 2003 Resolved
Re-attach captive chain for hatch cover to lazarette not later than 09Feb03 LEGACY COMPONENT DESC: Captive chain in watertight hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 13 January 2003
Resolution: Observed reconnected by [name withheld].
Navigation
Issued 8 December 1998 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Properly mark location of PFDs.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Provide log for emergency drills.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Documentation
Issued 8 December 1998 Resolved
Provide Oil Discharge Placard.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Mark vsl name on ring buoy.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Display emergency procedures.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Documentation
Issued 8 December 1998 Resolved
Provide Certificate of Documentation.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Mark vsl name on PFDs.
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999
Documentation
Issued 8 December 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 December 1998
Resolved 22 February 1999

Casualty record · 1

2 June 2012Routine · role: Involved in a Marine Casualty · activity 4335865
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.