Documentation record
Registered dimensions (L × B × D)195.0 ft × 52.5 ft × 12.5 ft
Registered tonnagegross 1,074 / net 1,074
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT · JEFFERSONVILLE, IN, UNITED STATES · built 1994
Hull materialSteel
PropulsionUnknown
Hull shapeBox
Hull configurationMonohull
Hailing portJEFFERSONVILLE, IN
Endorsements, as the file codes themcw_un
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1074 - Simplified, Gross Ton
1074 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 48
3 May 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7906109
8 February 2019
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6622618
9 July 2018
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6473084
2 January 2018
Annual Survey · MTSA Verification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6336142
9 December 2016
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6055298
7 December 2015
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5788342
6 January 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5049267
16 December 2013
Cargo Tank Internal · Administrative Inspection · COI Inspection · Drydock Exam · Examination of Repairs · MTSA Verification · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4770047
23 October 2012
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4474341
28 March 2012
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4274322
6 March 2012
Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4257790
9 February 2012
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4244293
9 February 2012
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4285101
3 October 2011
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4160090
1 October 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4166747
26 September 2011
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4152543
22 October 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3879900
2 June 2010
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3755625
16 April 2010
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3717807
20 May 2009
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3479838
21 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3384499
25 November 2008
Internal Structural Exam · Cargo Tank Internal · COI Inspection · MTSA Verification · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3369090
22 April 2008
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3163069
27 February 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2875744
1 June 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2667695
29 December 2005
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2557733
31 July 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2473528
30 November 2004
Annual Inspection · MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2250488
9 February 2004
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2002814
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984004
11 February 2003
Periodic Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1742874
30 January 2002
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1482604
16 January 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406847
22 February 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047236
2 March 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441456
25 January 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416828
2 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433292
7 March 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392625
8 October 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 517914
7 April 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 119196
24 January 1996
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1189444
24 July 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 497046
24 July 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 500171
19 May 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1182825
4 May 1995
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1032620
8 August 1994
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1178986
12 May 1994
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1169778
1 March 1994
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 853579
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 23 October 2012
Resolved
TBSIP Examiner found 03 scupper plugs frozen during annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2012
Resolved 23 October 2012
Resolution: Replaced all scuppers
Construction/Loadline › Hull › Hull Plating
Issued 9 February 2012
Resolved
"D8 TBSIP SELF-REPORTED DEFICIENCY" Port #1 wing void 6' Aft of the fwd B/H at the floor frame in the bottom 11/2" x
1/16" fracture.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 March 2012
Resolved 6 March 2012
Resolution: Damaged area renewed with an approx. 2'' x 3'' x 3/8" insert. Air test conducted sat.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2012
Resolved
Port #1 wing void 6' aft of the fwd b/h at the floor frame in the bottom there is 1 1/2" x 1/16" fracture.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 March 2012
Resolved 6 March 2012
Resolution: C/R 3/8" x 24" x 36" piece of bottom plate stbd side of #1 void adjacent to bilge knuckle.
Construction/Loadline › Hull › Side Shell
Issued 3 October 2011
Resolved
Vessel is to proceed empty to TT 104 for repairs to two punctures in the # 2 port void, one at the 6' draft mark (6'L x 6"W) and one at the 9' draft mark (3.5' x 4"). After repairs contact Sector NOLA dispatcher to schedule a repair check.
Action required: 705 - Other - as specified
Resolved 7 October 2011
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 22 October 2010
Resolved
Vapor gauge inoperable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2010
Resolved 22 October 2010
Resolution: Replaced gauge.
Deck/Cargo › Towing › Terminal Gear
Issued 22 October 2010
Resolved
STRBD stern winch cable broken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2010
Resolved 22 October 2010
Resolution: Replaced wire rope.
Construction/Loadline › Hull › Hull Plating
Issued 16 April 2010
Resolved
1"x1/16" pinhole on the #2 wing void, 20' aft of the fwd B/H at the 0" draft mark.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2010
Resolved 2 June 2010
Resolution: Witnessed satisf.actory repairs to #2 wing void, 8''x11'' plate insert, 10''x4'' bilge knuckle insert
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 February 2007
Resolved
Service tags were torn off two portable fire extinguishers on deck, vsl must provide servicing report for these extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 February 2007
Resolved
Fuel line and return line between the fixed piping and fuel filter/engine block on the prime mover is worn and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2007
Fire Fighting › Combustible Materials › Linings
Issued 27 February 2007
Resolved
Remove oily rags from under machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 February 2007
Resolved
Two temperature gauges on the gauge panel on the prime mover, but one was not connected to a sensor and the other was not working.
Due 29 March 2007
Resolved 1 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 January 2002
Resolved
Electrical connections not intrinsically safe in Class I, Div I hazardous area. Cargo Tank overfill/high level alarm cable seal glands worn. (46 CFR 39.20-9 (b))
Condition: Improper Installation
Due 30 January 2002
Resolved 30 January 2002
Resolution: All cable seals/glands repired IAW UL 913. (46 CFR 105.11)
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 30 January 2002
Resolved
Cargo tank visual level indicator IWO #1 stbd cargo tank inoperative. LEGACY COMPONENT DESC: Cargo Tank Level Indicator
Condition: Unknown
Due 30 January 2002
Resolved 30 January 2002
Resolution: Graduated rod replaced.
Deck/Cargo
Issued 4 May 1995
Resolved
GAS-FREE AND MAKE AVAILABLE FOR INSPECTION OF VAPOR RECOVERY SYSTEM TO CHECK FOR POLYMERIZATION.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995