Records from 1994 to 2026. Most recent: inspection, 2 March 2026.
Inspection history · 127
2 March 2026
Periodic Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8318573
10 February 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8077145
20 February 2024
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7860846
26 January 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7850879
12 October 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7807557
14 February 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636149
7 February 2022
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7394805
7 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328167
7 April 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7170570
3 March 2021
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7155113
22 March 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6930258
26 February 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6916341
26 October 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6842527
8 March 2019
Internal Structural Exam · Drydock Exam · MTSA Verification · COI Inspection · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6639016
21 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6545707
3 April 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384506
15 March 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6372375
5 April 2017
Drydock Exam · Periodic Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118168
6 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848530
13 April 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5102265
24 February 2014
COI Inspection · Internal Structural Exam · MTSA Verification · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4804937
27 April 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4297022
4 April 2012
Internal Structural Exam · Periodic Inspection · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4280465
7 July 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3788851
6 May 2010
Annual Inspection · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3722858
11 March 2009
Internal Structural Exam · Cargo Tank Internal · MARPOL Annex VI Survey · MARPOL Annex V Examination · MTSA Verification · In-Service Inspection · Drydock Exam · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3431431
7 March 2008
Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3441258
8 January 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3126636
30 November 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3107486
3 April 2007
Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection · Hull Examination · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2900577
12 September 2006
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2776168
9 September 2006
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2775192
9 September 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2775504
31 March 2006
Annual Inspection · Deficiency Check · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2613774
13 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2601788
25 January 2006
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2573067
19 October 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2517433
12 April 2005
MARPOL Annex I Examination · Annual Inspection · MTSA Verification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2331830
1 February 2005
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2284753
4 March 2004
Internal Structural Exam · COI Inspection · MARPOL Annex I Examination · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2017780
2 April 2003
Annual Inspection · Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1733525
28 January 2003
In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1737161
2 May 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1612096
25 April 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609552
8 March 2002
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1492233
16 January 2002
MARPOL Annex V Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1478990
19 November 2001
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1433913
5 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 45162
13 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071350
18 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 16171
11 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 111839
30 July 2001
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 442914
25 April 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062024
28 March 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1061569
1 March 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1444476
28 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 468417
10 November 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 171824
5 October 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 520839
2 September 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 503816
20 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 515915
7 April 2000
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 523596
16 March 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 51003
22 February 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1046067
21 January 2000
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1048037
14 January 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464904
13 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 26044
8 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 444784
2 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 436608
2 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 500830
19 November 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 458258
7 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 10295
6 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 62767
1 July 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1088274
3 June 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 440827
23 April 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 790972
20 April 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123804
25 March 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399071
22 March 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779448
28 December 1998
Examination of Repairs · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441439
27 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 114394
21 November 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 8266
16 November 1998
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805639
13 November 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 63112
13 November 1998
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 805382
3 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 5013
14 October 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 451531
6 August 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 39768
7 March 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 156901
4 February 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107576
19 December 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 446420
30 July 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 439542
15 July 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 60516
7 June 1997
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 776956
7 June 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1386020
6 June 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 165544
6 June 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1112432
8 May 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 533491
22 March 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 157517
22 March 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1400525
8 March 1997
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1092824
12 February 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106119
27 October 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 539636
20 September 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 470599
1 March 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 509512
12 February 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877595
11 February 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104445
31 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 22725
23 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 205886
23 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 205887
23 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760407
23 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760408
14 June 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467268
6 May 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 470369
24 March 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 489817
26 January 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142319
25 January 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143891
20 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 144218
5 December 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 503015
19 September 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870207
10 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1176596
2 August 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171789
7 July 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866488
27 April 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 92066
30 March 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 642907
20 March 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 366352
19 March 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 507452
16 February 1994
Initial Certification · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1356548
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 March 2026
Resolved
...Each nonrising-stem valve, lever-operated valve, or other valve where, because of design, the position of the disc or closure mechanism is not obvious must be fitted with an indicator to show whether the valve is opened or closed. No such indicator is required for any valve located in a tank or similar inaccessible space when indicators are available at accessible sites. The operating levers of quarter-turn valves must be parallel to the fluid flow when open and perpendicular to the fluid flow when closed. 46 CFR 56.20-9(a). All remote cargo tank valves did not have an indicator of opening or closure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 March 2026
Resolution: Oil xfr procedures articulate lashing practices
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 February 2023
Resolved
Each survival craft must be approved and equipped as follows. Each inflatable life raft must be under approval series 160.151 and equipped with a SOLAS A pack. Vessel has 4 person non SOLAS A life raft installed. 46 CFR 199.261
To be completed prior to dry dock credit, FEB 2024.
Action required: 705 - Other - as specified
Due 31 October 2026
Resolved 8 November 2023
Resolution: witnessed successful installation of correct liferaft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2023
Resolved
Classes I, II, and III pressure vessels not containing hazardous materials must be designed and constructed in accordance with the requirements in Section VIII, division 1, of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01-1) and must be stamped with the ASME “U” symbol. Pressure vessels nameplate must be made clean and visible. 46 CFR 54.01-5(c)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 17 March 2023
Resolution: Vessel provided photos of the cleaned air receiver placard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 February 2023
Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. Paint is covering instructions in thermal fluid heater space and instructions are missing in generator space.46 CFR 34.01-5(b)(2); 46 CFR 95.15-10(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 21 March 2023
Resolution: Vessel provided documentation attesting to placards being posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 February 2023
Resolved
Spaces protected by carbon dioxide - “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING". All spaces protected by CO2 do not have the required warning signs at the entrance of the spaces. 46 CFR 34.01-5(b)(2); 46 CFR 95.15-10(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 21 March 2023
Resolution: Vessel provided documentation attesting to placards being posted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 February 2023
Resolved
Armored and metallic sheathed cable. When installed, the metallic armor or sheath must meet the installation requirements of Section 25 of IEEE 45–2002 (incorporated by reference; see 46 CFR 110.10–1). Section 25.3 of IEEE 45-2002 For cable provided with armor, the armor should be electrically continuous between terminations and should be grounded at each end ( multi conductor cables only). 1) There is a break in the armor cable appx. 2ft from anchor winch control switch. 2) there is a break in the armor cable in wire bundle leading to forward navigation light tower. (Above fwd containment wall) 46 CFR 111.05-7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 21 March 2023
Resolution: Vessel provided documentation from certified electrician verifying continunity between armor cabling.
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 14 February 2023
Resolved
Emergency tow cable; The owner or operator of the system shall inspect it annually. The inspection must verify that the emergency retrieval system is ready for immediate use, and must include a visual inspection of the equipment that comprises the system in accordance with the manufacturer's recommendations. The emergency tow cable is secured without the ability to breakaway. Vessel must be retrofitted with breakaway clips or similar arrangement. 33 CFR 155.230
To be completed prior to dry dock credit, FEB 2024.
Action required: 705 - Other - as specified
Due 31 October 2026
Resolved 8 November 2023
Resolution: witnessed successfull repair of item
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 12 April 2021
Resolved
The cargo transfer piping shall be tested at least once a year for tightness. Each transfer pipe system must not leak under static liquid load pressure of at least 150% MAWP. Due to your operational constraints, vessel is allowed to complete current cargo discharge. Upon completion of the discharge, vessel is restricted from conducting cargo operations until a liquid load pressure test is conducted through-out the cargo transfer pipe system. All tests must be to the satisfaction of the attending USCG inspector.
Prior to next cargo ops, after completing current discharge.
Action required: 705 - Other - as specified
Resolved 18 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 March 2021
Resolved
LIFERAFTS SHALL BE STOWED IN A POSITION PROVIDING EASY SIDE TO SIDE TRANSFER AT A SINGLE OPEN DECK LEVEL. THE LIFERAFT WAS STOWED ON TOP OF THE ACCOMODATION SPACE. TO BE RECTIFIED AT NEXT DRYDOCK.
Action required: 705 - Other - as specified
Resolved 20 October 2021
Resolution: Received photographic evidence that liferaft was place in a satisfactory location.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2021
Resolved
Locations within 5 meters (16-ft) of cargo pressure/vacuum valves with an unlimited height, are required to meet Class 1, Division 1 measures. Pressure/Vacuum valves for #4 port and starboard cargo tanks are within 16-ft of the ventilation for cargo pump space.
Vessel shall only carry Grade D & E cargo with a flashpoint of 140 degrees F or above in Cargo Tanks #4 port and starboard. This will be in effect until their next dry dock credit when they must either move the PV valve or the affected air intake.
46CFR31.35-1
46CFR111.105-31(l)(3)
Action required: 705 - Other - as specified
Resolved 18 October 2021
Resolution: New location of P/V valve was more than 16 feet away from the cargo pump room ventillation.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 26 February 2020
Resolved
The cargo transfer piping shall be tested at least once a year for tightness. Each transfer pipe system must not leak under static liquid load pressure of at least 150% MAWP. Due to your operational constraints, vessel is allowed to complete current cargo discharge. Upon completion of the discharge, vessel is restricted from conducting cargo operations until a liquid load pressure test is conducted through-out the cargo transfer pipe system. All tests must be to the satisfaction of the attending USCG Marine Inspector.
Prior to next cargo ops, after completing current discharge.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2020
Resolution: Received hydrostatic test report.
Documentation › Logs/Records › Oil Record Book
Issued 3 April 2018
Resolved
Each completed op shall be signed by PIC and each completed page shall be signed by the master. Uncompleted pages are pre-signed.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 15 March 2018
Resolved
The cargo transfer piping shall be tested at least once a year for tightness. Due to operational constraints, vessel is allowed to complete current cargo discharge. Upon completion of the discharge, vessel is restricted from conducting cargo operations until a pressure test is conducted.
Action required: 705 - Other - as specified
Resolved 15 September 2018
Resolution: Reiceved all testing certificates for hydrstatic tests conducted.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 14 April 2014
Resolved
Vessel must demonstrate the proper operation of the High level alarm and Tank Overfill alarm loss of power system. 46CFR39.2009(a)(1) & 46CFR39.2007(b)(2)
Due 14 May 2014
Resolved 15 April 2014
Resolution: Vessel properly demonstrated the operation of loss of power system to the liquid overfill protection.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 24 February 2014
Resolved
Vessel does not have a line throwing gun onboard. Vessel is a Permissively Manned Barge, Route: Ocean International. 46 CFR 199.610(a) & 46 CFR 199.170(a). Correct prior to Coastwise/ Oceans Route.
Due 21 April 2014
Resolved 15 April 2014
Resolution: Vessel was provided with a line throwing gun.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 24 February 2014
Resolved
Bunker delivery notes shall be kept onboard & readily available for inspection at all reasonable times. Shall be retained for a period of 3 years after fuel has been delivered onboard. Vessel unable to provide delivery notes for the last 9 fuel transfers. Last delivery note provided was for 09September 2013. MARPOL Annex VI Reg 18.6.
Due 14 May 2014
Resolved 2 May 2014
Resolution: Received email from vessel representative showing bunker delivery analysis identifying sulfur content and delivery date.
Lifesaving › Immersion Suits › Not on Board
Issued 6 May 2010
Resolved
Provide additional immersion suit.
Action required: 705 - Other - as specified
Due 6 June 2010
Resolved 11 May 2010
Resolution: Received receipt from vessel rep.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 11 March 2009
Resolved
Demonstrate full compliance to MARPOL Annex VI regulations in order to obtain required IAPP certificate. Vessel is limited to
Domestic voyages until compliance is proven.
Action required: 705 - Other - as specified
Resolved 6 May 2010
Resolution: Completed satisfactory MARPOL Annex VI initial survey.
Deck/Cargo › Cargo Heating › General
Issued 27 April 2007
Resolved
Conduct Boiler Safety Tests on Therml Fluid Heater
Action required: 705 - Other - as specified
Resolved 27 April 2007
Resolution: Crew was able to complete satisfactory safety checks prior to CG Inspector departure
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 27 April 2007
Resolved
Install hard-wired bunk lights on all berthings
Due 11 May 2007
Resolved 30 April 2007
Resolution: Received digital pictures of satisfactory installation of lighting for berths
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 27 April 2007
Resolved
Provide proof of calibration of gas meter. Operational check was satisfactory.
Due 11 May 2007
Resolved 11 May 2007
Resolution: Recieved fax of calibration done be SeaSafety on 09May07.
Construction/Loadline › Structures › Rake
Issued 9 September 2006
Resolved
Do not load cargo prior to CG marine Inspector conducting ISE of the fwd rake and fwd 3 strb voids.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2006
Resolved 22 September 2006
Resolution: Made repairs to the satisfaction of the attending marine inspector.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 19 October 2005
Resolved
Vessel's anchor winch has failed and will not weigh anchor. With out a functioning anchoring system as required by 33CFR155.230(b)(1) the vessel is not allowed to operate in the RNAs surrounding the Hudson River and Upper New York Bay therefore restriction the vessel to RIVERS Route.
Action required: 705 - Other - as specified
Resolved 19 October 2005
Resolution: Received ABS report attesting to proper repairs.
Fire Fighting › Firemans Outfit
Issued 2 April 2003
Resolved
Vsl missing spare bottle for SCBA. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Due 2 May 2003
Resolved 1 May 2003
Communications › Alarms/Indicators
Issued 2 April 2003
Resolved
Vsl's smoke detectors in galley and berthing area inoperable. LEGACY COMPONENT DESC: Fire Alarm
Due 2 May 2003
Resolved 1 May 2003
Electrical › Electric Supply System (service)
Issued 2 April 2003
Resolved
Vsl's brackets on electrical cables on fwd mast wasted and/or broken off. LEGACY COMPONENT DESC: Cable
Due 2 May 2003
Resolved 1 May 2003
Fire Fighting › Combustible Materials
Issued 2 April 2003
Resolved
Remove combustible materials located in generator space.
Due 2 May 2003
Resolved 1 May 2003
Engineering › Diesel Engine (auxiliary)
Issued 19 November 2001
Resolved
COMPLETE AS BUILT VERIFICATION FOR THE NEW INSTALLATION OF DETROIT DIESEL ELECTRONICALLY CONTROLLED SERIES 60 CARGO PUMP PRIME MOVERS, IAW NYCMI APPROVED PLANS AND LETTER PR-020019.
Due 29 March 2002
Resolved 1 May 2003
Engineering
Issued 1 March 2001
Resolved
SECURE THERMAL FLUID HEATER UNTIL PERMANENT REPAIRS MADE AND REPAIRS TEST SAT TO ATTENDING [name withheld] SAT TO CGMI.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Deck/Cargo
Issued 1 March 2001
Resolved
REPAIR OVERFILL ALARM TO #2 STBD CARGO TANK.
Condition: Unknown
Due 8 March 2001
Resolved 6 March 2001
Deck/Cargo
Issued 21 January 2000
Resolved
PAINT/STENCIL SWL ON BOTH CARGO HOSE BOOMS.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Lifesaving
Issued 21 January 2000
Resolved
INSTALL FAN BELT GUARDS ON BOTH S/S GENERATORS.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Construction/Loadline
Issued 14 January 2000
Resolved
VESSEL TO PROCEED TO NORWALK, CT. TO OFFLOAD CARGO. THEN TO PROCEED (UNLOADED) IN FAIR WEATHER ONLY TO STATEN ISLAND TO AFFECT PERMANENT REPAIRS TO CRACK IN BILGE STRAKE, STBD AFT RAKE. MUST MAINTAIN PORTABLE PUMPS ABOARD VESSEL AND INSPECT DAM AREA EVERY 30 MIN UNTIL ARRIVAL IN S.I.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 25 March 1999
Resolved
Replace existing hand flares with 12 rocket parachute flares as per 46CFR199.60(c).
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Deck/Cargo
Issued 25 March 1999
Resolved
Repair #4 stbd cargo tank high level alarm. Prove proper operation of cargotank high level alarm system.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Lifesaving
Issued 25 March 1999
Resolved
Provide a USCG approval number for line throwing appliance as per 46CFR199.170.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Construction/Loadline
Issued 25 March 1999
Resolved
Install bilge pumping system for the forward and aft rakes to the satisfaction of an attending USCG marine inspector IAW 46 CFR 56.50-55(b).
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Construction/Loadline
Issued 28 December 1998
Resolved
VSL MAY PROCEED TO NORWALK, CT TO DISCHARGE CURRENT LOAD OF CARGO. VSL MUST THEN PROCEED DIRECTLY TO A CLEANING FACILITY TO CLEAN & CONDUCT REPAIRS IAW ABS RPT #NY-3887 DTD 28DEC98. NO CARGO MAY BE LOADED UNTIL REPAIRS COMPLETED TO SATISFACTION OF OCMI & ABS.
Condition: Unknown
Due 30 December 1998
Resolved 8 January 1999
Construction/Loadline
Issued 13 November 1998
Resolved
PROVE BOTTOM INSPECTION COMPLETE PRIOR TO LOADING CARGO. NOTIFY OCMI IN NEW YORK WHEN COMPLETE. DO NOT LOAD CARGO UNTIL [name withheld] IT.
Condition: Unknown
Due 26 December 1998
Resolved 26 December 1998
Construction/Loadline
Issued 6 June 1997
Resolved
Vessel is directed to proceed to Staten Island, NY. During transit, soundings and visual exams shall be conducted every 30 minutes. No cargo may be loaded until a damage survey is completed by the CG. Upon arrival inStaten Island, make the vessel available and ready for a CG inspection.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Unknown
Issued 22 March 1997
Resolved
Vessel has torn hull at #5 CT starboard side.
Condition: Unknown
Due 28 March 1997
Resolved 7 April 1997
Lifesaving
Issued 8 March 1997
Resolved
PROVIDE SPARE SELF CONTAINED BREATHING APPARATUS BOTTLE.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Lifesaving
Issued 8 March 1997
Resolved
PROVE PROPER OPERATION OF SELF CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Lifesaving
Issued 8 March 1997
Resolved
PROVIDE FLASHLIGHT AND EXTRA BATTERIES FOR EMERGENCY OUTFIT.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Fire Fighting
Issued 8 March 1997
Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF FIRE EQUIPMENT.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Lifesaving
Issued 8 March 1997
Resolved
REPLACE LIGHT ON LIFE PRESERVER AS NEEDED.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Lifesaving
Issued 8 March 1997
Resolved
REMOVE OBSTACLES IN WAY OF ESCAPE SCUTTLES.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Lifesaving
Issued 8 March 1997
Resolved
PROVE PROPER OPERATION OF COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 11 March 1997
Resolved 16 March 1997
Construction/Loadline
Issued 26 January 1995
Resolved
MAKE PERMANENT REPAIRS TO BOTTOM PLATING AND ASSOCIATED INTERNAL FRAMING INTHE PORT SIDE FWD RAKE AND PORT WING TANK.
Condition: Unknown
Due 3 February 1995
Resolved 3 February 1995
Documentation
Issued 2 August 1994
Resolved
BARGE HAS ADEQUATE STABILITY & STRENGTH TO PERMIT CARRIAGE OF A CARGO WITH A SPECIFIC GRAVITY OF 10489 OR LESS ON A MANNED VOYAGE FROM PORT OF NEW YORK, NY TO MONTVILLE, CT OR NORWALK, CT. DURING THIS VOYACE, CARGO TANKS SHALL BE LOADED IN ACCORDANCE C.R. CUSHIHNG LTR 1847PS48.DOC DATED 1JUL94.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 7 July 1994
Resolved
& STRENGTH TO PERMIT CARRIAGE OF A CARGO WITH A SPECIFIC GRAVITY OF 1.067 ON AN UNMANNED OCEAN VOYAGE FROM PORT OF PHILADELPHIA TO PORT OF NEW YORK. DURING THIS VOYAGE, CARGO TANKS SHALL BE LOADED IN ACCORDANCE WITH DATA & CALCULATIONS SUBMITTED IN C.R. CUSHING LETTER 1847PL48.DOC DTD 07JUL94.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Lifesaving
Issued 7 July 1994
Resolved
SUBMIT UPDATED STABILITY & CARGO LOADING CALCULATIONS TO USCG MARINE SAFETYCENTER, WASHINGTON, DC. UPDATED CALCULATION SHALL ADDRESS CARRIAGE OF CARGOES WITH SPECIFIC GRAVITIES IN EXCESS OF 1.025 (8.5 LBS/GAL). UNTIL CALCULATION ARE APPROVED, BARGE HAS ADEQUATE STABILITY (CONT)
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994