Inspection history · 51
12 February 2018
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6353793
2 February 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6097762
3 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808870
18 December 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5827219
14 November 2014
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5022743
19 August 2014
Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958648
26 June 2014
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4899518
19 May 2014
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4860200
28 June 2012
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4360012
8 November 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4203731
30 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3901026
8 November 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3901029
14 May 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3474766
28 April 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3469779
12 January 2009
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392770
1 July 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3253744
4 February 2008
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3141394
13 January 2006
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2566298
9 November 2005
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2531682
29 March 2005
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2322226
24 November 2004
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Cargo Tank Internal · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2247420
6 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001896
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963403
11 August 2003
Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1873817
11 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1886861
21 January 2003
Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1732916
8 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1485230
27 October 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1598583
16 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448218
29 November 2000
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1055512
25 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 29474
25 October 2000
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 823556
11 February 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461239
2 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 481300
30 June 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 494956
23 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 475997
21 January 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430635
23 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 10557
15 April 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396903
8 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479463
6 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784532
22 September 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 512076
15 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179064
19 February 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406051
16 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1156344
23 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1084139
23 April 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409491
7 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882565
22 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877429
18 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867390
22 February 1995
Initial Construction-Excluding Oversight · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439602
Deck/Cargo › Cargo Heating › General
Issued 12 February 2018
Resolved
Prior to loading of next cargo and prior to operation of thermal fluid heater provide satisfactory operational tests of thermal fluid heater in presence of Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 17 April 2018
Resolution: Thermal Fluid Heater removed, test no longer required.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 February 2017
Resolved
Draft marks not legible
Condition: Improper/Lack of Maintenance
Due 2 March 2017
Resolved 2 February 2017
Resolution: Crew painted draft marks
Construction/Loadline › Hull › Side Shell
Issued 19 May 2014
Resolved
Crop/renew sharp inset at Port Sideshell, aft end of #1 void.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Hull › Side Shell
Issued 19 May 2014
Resolved
Crop/renew area of 3 sharp insets, Port Sideshell appx half way through #1 void at waterline.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014
Resolved
Stbd stern corner deck-crop/renew deck knuckle at stern.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See activity 4899518
Construction/Loadline › Structures › Rake
Issued 19 May 2014
Resolved
Crop/renew damage to stbd bow rake, in way of 3 foot waterline mark and rub rail.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014
Resolved
Crop/renew Stbd midship deck knuckle 1 foot by 4 foot area with 3-4 inch inset.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014
Resolved
Crop/renew stbd aft deck knuckle 1 foot by 3 foot section in way of timber bitts.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Hull › Hull Plating
Issued 19 May 2014
Resolved
Provide gauging report for #1 tank tops in way of centerline, and to pt/stbd of centerline appx 10x25 foot area. Provide gauging for stbd outboard of S2 tank dome appx 14 feet forward of mid ship ladder guage deepest single pit and area around this.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 7 October 2014
Resolution: Air tested 4 plates that were inserted to replace sections of bad deck that were called out in this deficancy by the gauging report. See Activity 4958648
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003
Resolved
Discharge Complete cargo of #6 oil prior to departing Texaco dock at Mile 98 LMR.
Condition: Damaged By Earlier Event
Due 12 August 2003
Resolved 12 August 2003
Stability › Watertight Integrity
Issued 12 August 2003
Resolved
Make temp repairs to the #5 Port wing void prior departure Texaco Marrero Dock. LEGACY COMPONENT DESC: Wing Voids
Condition: Damaged By Earlier Event
Due 12 August 2003
Resolved 12 August 2003
Stability › Watertight Integrity
Issued 12 August 2003
Resolved
Vessel allowed to transit thru the [name withheld] the the ICW to the Bourg Dry-dock Houma La. on a one way trip. No other cargo operations allowed until repairs to the #5 Port wing void completed to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: #5 Port Wing Void
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2003
Resolved 2 February 2004
Resolution: REPAIR TO VOID COMPLETE.
Engineering › Fuel Oil Service System
Issued 21 January 2003
Resolved
Fuel hose was worn due to lack of chaffing material. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Installed chaffing material on fuel line on generator during inspection.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 January 2003
Resolved
Flame screen loose on Pressure/Vaccum vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Repaired vent and installed new screen during inspection. Screen was missing locking ring to secure screen in place.
Electrical › Electrical Distribution System (service)
Issued 21 January 2003
Resolved
Non conducting electrial mat was missing in front of generator electrical panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Owner installed a non conducting electrical mat in front of generator electrical panel during inspection.
Electrical › Electrical Distribution System (service)
Issued 21 January 2003
Resolved
Missing non-conductive deck mat in front of thermal fluid heater control electrical panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Owner installed non-conductive mat during inspection.
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2002
Resolved
Replace fuel hoses not to exceed max of 30"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 February 2002
Resolved
Provide permanent bracket for all fire extinguirsers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Deck/Cargo › Cargo Heating
Issued 8 February 2002
Resolved
Demonstrate proper operation of all alarms and shut downs for thermal fluid heater.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 28 February 2002
Construction/Loadline
Issued 25 October 2000
Resolved
Effect permanent repairs to plating insets in way of port bow rake below headlog.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 23 April 1996
Resolved
PROVIDE COPY OF APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN AS REQUIREDBY 33 CFR 151.09
Condition: Unknown
Due 23 April 1996
Resolved 23 April 1996
Deck/Cargo
Issued 18 April 1995
Resolved
VAPOR RECOVERY SYSTEM IS NOT TO BE OPERATED UNTIL ALARM SYSTEM IS INSTALLEDAND PLANS ARE APPROVED BY THE MSC. ALARMS TESTS ARE TO WITNESSED BY A MARINE INSPECTOR.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Deck/Cargo
Issued 22 February 1995
Resolved
PRIOR TO CARRYING ELEVATED TEMP CARGOES, A HYDROSTATIC TEST OF THE CARGO HEATING PIPING, AND AN OPERATIONAL TEST OF THE FIRED THERMAL FLUID HEATER MUST BE CONDUCTED.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Deck/Cargo
Issued 22 February 1995
Resolved
PRIOR TO CARRYING CARGO PROVE OPERATION OF THE CARGO PUMP ENGINE REMOTE STOP.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995