MAURY USCG vessel records
← All vessels

GONSOULIN 107

Built
1995
Last inspected
12 February 2018
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 12 February 2018
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1995–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

403184
Flag
UNITED STATES
Maury page id
psix-403184

Documentation record

Registered dimensions (L × B × D)297.6 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE GROUP · GULFPORT, MS, UNITED STATES · built 1995
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 51 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 51

12 February 2018 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6353793
2 February 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6097762
3 February 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808870
18 December 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5827219
14 November 2014 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5022743
19 August 2014 Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958648
26 June 2014 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4899518
19 May 2014 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4860200
28 June 2012 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4360012
8 November 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4203731
30 November 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3901026
8 November 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3901029
14 May 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3474766
28 April 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3469779
12 January 2009 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392770
1 July 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3253744
4 February 2008 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3141394
13 January 2006 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2566298
9 November 2005 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2531682
29 March 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2322226
24 November 2004 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Cargo Tank Internal · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2247420
6 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001896
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963403
11 August 2003 Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1873817
11 August 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1886861
21 January 2003 Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1732916
8 February 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1485230
27 October 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1598583
16 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448218
29 November 2000 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1055512
25 October 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 29474
25 October 2000 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 823556
11 February 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461239
2 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 481300
30 June 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 494956
23 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 475997
21 January 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430635
23 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 10557
15 April 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396903
8 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479463
6 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784532
22 September 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 512076
15 March 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179064
19 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406051
16 October 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1156344
23 May 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1084139
23 April 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409491
7 July 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882565
22 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877429
18 April 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867390
22 February 1995 Initial Construction-Excluding Oversight · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439602

Deficiency record · 24

Deck/Cargo › Cargo Heating › General
Issued 12 February 2018 Resolved
Prior to loading of next cargo and prior to operation of thermal fluid heater provide satisfactory operational tests of thermal fluid heater in presence of Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 17 April 2018
Resolution: Thermal Fluid Heater removed, test no longer required.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 February 2017 Resolved
Draft marks not legible
Condition: Improper/Lack of Maintenance
Due 2 March 2017
Resolved 2 February 2017
Resolution: Crew painted draft marks
Construction/Loadline › Hull › Side Shell
Issued 19 May 2014 Resolved
Crop/renew sharp inset at Port Sideshell, aft end of #1 void.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Hull › Side Shell
Issued 19 May 2014 Resolved
Crop/renew area of 3 sharp insets, Port Sideshell appx half way through #1 void at waterline.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014 Resolved
Stbd stern corner deck-crop/renew deck knuckle at stern.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See activity 4899518
Construction/Loadline › Structures › Rake
Issued 19 May 2014 Resolved
Crop/renew damage to stbd bow rake, in way of 3 foot waterline mark and rub rail.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014 Resolved
Crop/renew Stbd midship deck knuckle 1 foot by 4 foot area with 3-4 inch inset.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2014 Resolved
Crop/renew stbd aft deck knuckle 1 foot by 3 foot section in way of timber bitts.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 26 June 2014
Resolution: See Activity 4899518
Construction/Loadline › Hull › Hull Plating
Issued 19 May 2014 Resolved
Provide gauging report for #1 tank tops in way of centerline, and to pt/stbd of centerline appx 10x25 foot area. Provide gauging for stbd outboard of S2 tank dome appx 14 feet forward of mid ship ladder guage deepest single pit and area around this.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 7 October 2014
Resolution: Air tested 4 plates that were inserted to replace sections of bad deck that were called out in this deficancy by the gauging report. See Activity 4958648
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003 Resolved
Discharge Complete cargo of #6 oil prior to departing Texaco dock at Mile 98 LMR.
Condition: Damaged By Earlier Event
Due 12 August 2003
Resolved 12 August 2003
Stability › Watertight Integrity
Issued 12 August 2003 Resolved
Make temp repairs to the #5 Port wing void prior departure Texaco Marrero Dock. LEGACY COMPONENT DESC: Wing Voids
Condition: Damaged By Earlier Event
Due 12 August 2003
Resolved 12 August 2003
Stability › Watertight Integrity
Issued 12 August 2003 Resolved
Vessel allowed to transit thru the [name withheld] the the ICW to the Bourg Dry-dock Houma La. on a one way trip. No other cargo operations allowed until repairs to the #5 Port wing void completed to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: #5 Port Wing Void
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2003
Resolved 2 February 2004
Resolution: REPAIR TO VOID COMPLETE.
Engineering › Fuel Oil Service System
Issued 21 January 2003 Resolved
Fuel hose was worn due to lack of chaffing material. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Installed chaffing material on fuel line on generator during inspection.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 January 2003 Resolved
Flame screen loose on Pressure/Vaccum vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Repaired vent and installed new screen during inspection. Screen was missing locking ring to secure screen in place.
Electrical › Electrical Distribution System (service)
Issued 21 January 2003 Resolved
Non conducting electrial mat was missing in front of generator electrical panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Owner installed a non conducting electrical mat in front of generator electrical panel during inspection.
Electrical › Electrical Distribution System (service)
Issued 21 January 2003 Resolved
Missing non-conductive deck mat in front of thermal fluid heater control electrical panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Owner installed non-conductive mat during inspection.
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2002 Resolved
Replace fuel hoses not to exceed max of 30"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 February 2002 Resolved
Provide permanent bracket for all fire extinguirsers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Deck/Cargo › Cargo Heating
Issued 8 February 2002 Resolved
Demonstrate proper operation of all alarms and shut downs for thermal fluid heater.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 28 February 2002
Construction/Loadline
Issued 25 October 2000 Resolved
Effect permanent repairs to plating insets in way of port bow rake below headlog.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 23 April 1996 Resolved
PROVIDE COPY OF APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN AS REQUIREDBY 33 CFR 151.09
Condition: Unknown
Due 23 April 1996
Resolved 23 April 1996
Deck/Cargo
Issued 18 April 1995 Resolved
VAPOR RECOVERY SYSTEM IS NOT TO BE OPERATED UNTIL ALARM SYSTEM IS INSTALLEDAND PLANS ARE APPROVED BY THE MSC. ALARMS TESTS ARE TO WITNESSED BY A MARINE INSPECTOR.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Deck/Cargo
Issued 22 February 1995 Resolved
PRIOR TO CARRYING ELEVATED TEMP CARGOES, A HYDROSTATIC TEST OF THE CARGO HEATING PIPING, AND AN OPERATIONAL TEST OF THE FIRED THERMAL FLUID HEATER MUST BE CONDUCTED.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Deck/Cargo
Issued 22 February 1995 Resolved
PRIOR TO CARRYING CARGO PROVE OPERATION OF THE CARGO PUMP ENGINE REMOTE STOP.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.