Records from 2003 to 2025. Most recent: inspection, 18 November 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2003
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5590 - Displacement, Net Ton
1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
18 November 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8270325
31 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8024290
28 August 2023
Cargo Tank Internal · Drydock Exam · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7780526
9 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7555117
6 August 2021
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7277857
29 June 2020
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6991938
25 October 2019
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6842069
5 March 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6637204
18 July 2018
Administrative Inspection · Internal Structural Exam · MTSA Verification · COI Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6483549
26 April 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6133240
17 August 2016
Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5975522
22 April 2015
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5108550
15 September 2014
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4984517
10 December 2013
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4766917
30 October 2013
Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4744923
17 October 2013
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4736647
17 October 2013
Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4752220
24 June 2013
Drydock Exam · In-Service Inspection · Examination of Repairs · MTSA Verification · Administrative Inspection · COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4630491
20 September 2012
Annual Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4445581
28 June 2012
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4360012
26 September 2011
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4161313
12 July 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3794640
8 March 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3692974
3 June 2009
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3494254
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335001
2 July 2008
Administrative Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3254841
7 August 2007
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 3020326
13 March 2007
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2887951
3 March 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2881897
3 March 2007
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2883666
31 August 2006
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2769117
12 September 2005
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2490179
10 September 2004
MTSA Verification · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2184525
23 February 2004
Examination of Repairs · Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2027663
23 February 2004
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2050788
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997440
24 June 2003
Deadweight Survey · Construction Oversight · Initial Certification · Internal Structural Exam · Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1808066
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 October 2013
Resolved
Vessel was covered in asphalt after a facility transfer hose ruptured. Vessel to be cleaned and equipment operationally tested to the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 November 2013
Resolved 1 November 2013
Resolution: Barge was cleaned and all deck equipment tested operationally. All SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 October 2012
Resolved
Electically controlled engine not in compliance wiht 46 CFR 111.1105.31(1). Extended def due date until 01 NOV 2015 for correction IAW D8 letter dated 05 NOV 2010.
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 12 July 2013
Resolution: Relocated pump engine outside the Class1 Div 1 hazardous zone.
Documentation › Markings/Placards › Warning Signs
Issued 5 October 2012
Resolved
Benzene warning sign required by 46 CFR 197 Subpart C not installed on vessel. Cargo tanks had residue from last cargo; crude oil. According to MSDS, cargo has a benzene content of 1-9% by volume. Vessel CAA authorizes carriage of crude oil and vessel rep had a written benzene program.
Action required: 705 - Other - as specified
Due 19 October 2012
Resolved 10 October 2012
Resolution: New warning sign installed.
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2008
Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31 (l). Vessel operator given until 18JUN10 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. Magnolia Marine Transport compliance plan and D8 compliance plan approval letter have been scanned into vessel documents.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 5 October 2012
Resolution: Extended def due date until 01 NOV 2015 for correction IAW D8 letter dated 05 NOV 2010.
Construction/Loadline › Hull › Hull Plating
Issued 7 March 2007
Resolved
Transit to New Orleans AOR to off load current cargo CCFB. After off loading cargo contact the local OCMI and make the #1 port wing tank and bow void gas free allowing for entry of Coast Guard marine inspectors.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2007
Resolved 14 March 2007
Construction/Loadline › Hull › Double Hull
Issued 23 February 2004
Resolved
Proceed directly to Morris, IL at ILR MM 265 to offload current cargo. No loading operations permitted until permanent repairs are made and inspected to the satisfaction of a attending Coast Guard Marine Inspector. Dewatering pumps will remain onboard until repairs are complete.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 March 2004
Resolution: Witnessed successful airtesting of 130'' of formed bilge knuckle, bottom plating and integrity of the involved W/T bulkheads.