Records from 1998 to 2026. Most recent: inspection, 7 April 2026.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 28.0 ft × 9.5 ft
Registered tonnagegross 124 / net 99
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCENAC TOWING CO INC · HOUMA, LA, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it124 - Simplified, Gross Ton
99 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 39
7 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8344365
30 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8198534
11 June 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8157207
30 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7904179
1 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7757615
12 April 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7667806
20 April 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7434918
14 July 2020
Initial Certification · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7006067
9 September 2019
Type not recorded
No type recorded · Station Houston · USCG Heartland District (CGD-H) · Activity 6808818
2 April 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5095494
27 January 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5059893
20 August 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4961348
30 December 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4508579
12 January 2012
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4223572
10 March 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3961383
10 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4013193
19 May 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3742345
22 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3437788
12 December 2008
Administration
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3380287
19 November 2008
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3366023
4 October 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3340260
4 October 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3340354
11 February 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3145287
8 February 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3148062
5 July 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2702265
9 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2644676
13 June 2005
MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2389083
8 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2271140
5 January 2005
MTSA Verification · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2270135
3 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2268116
31 March 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2043914
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965165
17 January 2003
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1782963
27 February 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1491539
17 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072456
7 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139806
25 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 29474
24 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2384
5 September 1998
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 93593
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2022
Resolved
-Starboard generator prime mover had a leaking inboard fuel injector with the o-ring dislodged from it's seating
-Port generator prime mover had missing clamp for the fuel oil return line, allowing excessive vibration.
-Multiple flexible fuel lines on the three main engines were showing signs of wear at chafing points.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2022
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge. The needle for the starboard pressure tank was found broken.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 April 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. The engine room had large accumulations of lube oil under each main engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2022
Resolved
The watertight doors on the port engine room and the door leading from the engine room to the forward space were missing a small section of gasket, not allowing the door to be watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in table 141.370. Six day and six night flares are required as per the table for ltd. coastwise route.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 April 2022
Resolved
Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft. Missing placards.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2022
Resolved
The penetrations above the watertight door between the engine room and the forward compartment were not sealed watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2022
Resolved 12 May 2022