Records from 1994 to 2007. Most recent: inspection, 3 April 2007.
Engineering
Issued 17 May 2000
Resolved
PROVIDE DEAD MAN TYPE RE-FUELING NOZZLES FOR ALL REFUELING STATIONS (CRANES, CEMENT UNIT).
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 17 May 2000
Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELLS TO PROVIDE ADEQUATE COVERAGE THROUGHOUT MAIN DECK. PROVIDE ADDITIONAL G/A LIGHT FOR ENGINE ROOM.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Documentation
Issued 17 May 2000
No resolution recorded
SUBMIT APPROVED SOPEP FOR 5 YEAR APPROVAL, DUE JULY 2000.
Condition: Unknown
Due 17 July 2000 — due date passed with no resolution recorded
Lifesaving
Issued 17 May 2000
Resolved
REPAIR REVERSE ON LIFEBOAT #2 ENGINE. REPAIR LIMIT SWITCH ON FWD FALLS OF SAME BOAT.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Fire Fighting
Issued 17 May 2000
Resolved
PROVIDE FIRE DOOR FOR GALLEY/DRY STORE BOUNDRY.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 20 May 1999
Resolved
REPAIR / REPLACE FORWARD HATCH / WINDOW OF #2 LIFE BOAT THAT HAS A BROKEN HINGE.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Lifesaving
Issued 20 May 1999
Resolved
ADD GENERAL ALARM BELLS TO COMPRESSOR ROOM AND WORK / STORAGE SPACES ON EITHER SIDE, REPAIR GENERAL ALARM BELL IN MUD PITS, AND PROPERLY LABEL ALL GENERAL ALARM BELLS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Electrical
Issued 20 May 1999
Resolved
CONDUCT AND LOG SEMI-ANNUAL LOAD TEST OF EMERGENCY BATTERIES.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Construction/Loadline
Issued 10 June 1997
Resolved
ENSURE ALL WATERTIGHT DOORS AND HATCHES ARE FUNCTIONAL AND ADJUSTED PROPERLY. COMPLETE PRIOR TO RE-FLOATING RIG.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Electrical
Issued 27 May 1997
Resolved
REPLACE DAMAGED ARMORED CABLE IN ALL HAZARDOUS LOCATIONS.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Lifesaving
Issued 27 May 1997
Resolved
PLACE CAGE ON CROWS NEST LADDER.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Lifesaving
Issued 27 May 1997
Resolved
REPAIR GENERAL ALARM SYSTEM. MAKE GENERAL ALARMS AUDIBLE AT ALL LOCATIONS.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Accommodation/Occupational Safety
Issued 27 May 1997
Resolved
REMOVE PERMANENT LOCKS FROM ACCOMMODATION ENTRY/EXIT POINTS.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Fire Fighting
Issued 27 May 1997
Resolved
TRAIN FIRE TEAMS IN PROPER USE OF SELF-CONTAINED BREATHING APPARATUS AND BASIC FIREFIGHTING TECHNIQUES.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Lifesaving
Issued 27 May 1997
Resolved
COMPLY WITH THE REVISED OPERATIONAL REQUIREMENTS OF 46 CFR 109. REFERENCE FEDERAL REGISTER, VOL. 61, NO. 98, DATED MAY 20, 1996, WHICH WAS PROVIDED AT THE TIME OF INSPECTION.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997
Resolved
LABEL CIRCUIT BREAKER PANELS THROUGHOUT RIG.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997
Resolved
IMPLEMENT POLICY TO (A) CONDUCT LINETHROWING APPLIANCE TRAINING EVERY 3 MONTHS, (B) CONDUCT 2-HR MONTHLY EMERGENCY GENERATOR TEST, (C) CONDUCT SEMIANNUAL EMERGENCY BATTERY TEST AND (D) OPERATE LIFEBOATS IN THE WATER ONA QUARTERLY BASIS. LOG EACH TEST APPROPRIATELY.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Fire Fighting
Issued 21 May 1996
Resolved
PLUG ALL HOLES IN CLASS A AND B BULKHEADS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
PROVIDE OPERABLE FLASHLIGHT AND SPARE BATTERIES IN FIREMAN LOCKER ON MAIN DECK.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
REPAIR FIRE DAMPER IN LIVING QUARTERS, UPPER LEVEL.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
CONDUCT AND LOG EMERGENCY GENERATOR AND EMERGENCY BATTERY TESTS PER 46 CFR 109.217.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROVIDE AUDIBLE PURGE LOSS ALARM FOR BAYTRON JUNCTION BOX IN DOG HOUSE ON DRILL FLOOR.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
PROPERLY SECURE ELECTRICAL CABLES GOING UP DERRICK.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
STENCIL GENERAL ALARM BELLS IN EMERGENCY GENERATOR ROOM AND P-TANK ROOM TO READ "WHEN ALARM SOUNDS, GO TO YOUR STATION"
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
MOUNT JUNCTION BOXES (2) AND REPLACE BROKEN COVER ON ONE (1) JUNCTION BOX BELOW DRILL FLOOR.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
REPAIR GENERAL ALARM IN MUD PUMP AREA.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
PROOF TEST SATISFACTORY OPERATION OF REMOTE VENTILATION SHUTDOWN TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 21 May 1996
Resolved
REPAIR FUEL OIL PUMP REMOTE SHUT DOWN.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
PROOF TEST SATISFACTORY OPERATION OF REVERSE POWER RELAYS, OVERSPEED TRIPS,LOW LUBE OIL PRESSURE ALARMS ON ALL GENERATORS TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
SUBMIT PROPOSAL TO FLAG STATE REP TO LOCATE PRIMARY LIFESAVING SO THAT A CASUALTY WOULD NOT IMMOBILIZE ALL LIFEBOATS OR LIFERAFTS PER 46 CFR 108.511(B).
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
REPAIR LEAK IN COMPASS IN LIFEBOAT #1
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
REPAIR FIRE NOZZLES AT FIRE HOSE STATIONS #17, #14, #10.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 21 May 1996
Resolved
FREE UP DOGS AND PROVIDE DOGGING WRENCH FOR WATER TIGHT DOOR ON STARBOARD SIDE GOING TO LOWER HULL.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996
Resolved
SUBMIT PROPOSAL TO INSTALL ADDITIONAL FIRE HOSE EQUIPMENT TO BE ABLE TO REACH PORT AND STARBOARD THRUSTER ROOMS IN ACCORDANCE WITH 46 CFR 108.423.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
PROOF TEST SATISFACTORY OPERATION OF AUTO-BUS TRANSFER FOR EMERGENCY GENERATOR TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 21 May 1996
Resolved
PROOF TEST SATISFACTORY OPERATION OF REMOTE FUEL SHUT DOWN FOR DAY TANK TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROOF TEST SATISFACTORY OPERATION OF PURGE LOSS ALARM ON ANNADRIL MONITOR AT DRILLERS CONSOLE TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
PROVIDE WORKING SHOULDER LIGHTS FOR ALL LIFEJACKETS. ENSURE SALTWATER LIGHTS HAVE NOT BEEN SPENT.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 21 May 1996
Resolved
CLEAN LINT FROM ALL VENTS IN LIVING QUARTERS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996
Resolved
PROPERLY CONNECT PLUG TO EXPLOSION PROOF RECEPTICLE ON STARBOARD AFT SIDE OF DRILL FLOOR
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Navigation
Issued 21 May 1996
Resolved
ENSURE ALL OBSTRUCTION LIGHTS FLASH IN UNISON.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996
Resolved
REPAIR PURGE LOSS ALARM FOR GENERATOR PANEL AT DRILLERS CONSOLE AND PROOF TEST TO THE SATISFACTION OF FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Documentation
Issued 21 May 1996
Resolved
PROVIDE OIL RECORD BOOK
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 23 May 1995
Resolved
MAKE HALON SYSTEM FOR MAIN GENERATOR ROOM OPERATIONAL AFTER ACCIDENTAL DISCHARGE OF SYSTEM BY SAFETY CONCEPTS SERVICE TECHS. PROVIDE THREE BV WHEEL UNITS FOR PROTECTION OF SPACE UNTIL HALON SYSTEM IS OPERATIONAL.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 23 May 1995
Resolved
PROVIDE ABS SURVEY REPORT FOR EXAMINATION OF CRANES. FOR LOC OPTION "A" CRANES MUST BE EXAMINED AND TESTED BY EITHER USCG, ABS OR ICGB.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 23 May 1995
Resolved
PROVIDE FLAG STATE/ABS APPROVED OPERATING MANUAL TO MARINE SAFETY OFFICE NEW ORLEANS FOR REVIEW.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Electrical
Issued 23 May 1995
Resolved
INSTALL RUBBER MAT IN FRONT OF SWITCHBOARD IN COMPRESSOR ROOM.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 23 May 1995
Resolved
PROVIDE APPROVED EMERGENCY EVACUATION PLAN ON BOARD.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Lifesaving
Issued 23 May 1995
Resolved
MARK ALL EMERGENCY EXIT HATCHES IN LOWER HULL WITH "EMERGENCY EXIT-KEEP CLEAR" ON INSIDE AND OUTSIDE OF SPACE.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Fire Fighting
Issued 23 May 1995
Resolved
REPLACE TWO (2) DEFECTIVE THERMAL DETECTORS FOR FIRE DETECTION IN PUMPROOM AND MUD PIT ROOM STARBOARD.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Documentation
Issued 23 May 1995
Resolved
PROVIDE APPROVED COPY OF SHIPBOARD OIL POLLUTION EMERGENCY PLAN ON BOARD.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Documentation
Issued 23 May 1994
Resolved
PROVIDE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Documentation
Issued 23 May 1994
Resolved
PROVIDE REVISED OPERATIONS MANUAL WITH FULL FLAG STATE APPROVAL.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Lifesaving
Issued 23 May 1994
Resolved
REPLACE DECK GRATING AS NECESSARY TO SUBSTRUCTURE.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Lifesaving
Issued 23 May 1994
Resolved
PROVIDE 1500 FT. AUXILLIARY LINE FOR LINE THROWING DEVICE.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994