MAURY USCG vessel records
← All vessels

SAN GABRIEL

Built
1976
Last inspected
19 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN9946
Flag
UNITED STATES
Maury page id
psix-48979

Documentation record

Registered dimensions (L × B × D)74.5 ft × 17.7 ft × 9.3 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ARTHUR, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 34 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

19 February 2026 Administrative Inspection · In-Service Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8307164
2 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8215277
5 June 2025 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8131745
27 February 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7885714
15 March 2023 COI Inspection · Inclining Experiment · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7651430
13 November 2022 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7594214
18 March 2022 In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7409625
6 April 2021 Annual Inspection · Deficiency Check · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7169654
19 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7159184
12 June 2020 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6966189
4 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6803449
14 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6709557
26 February 2019 Examination of Repairs · Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6632945
31 May 2018 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6423778
21 April 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6129696
7 February 2017 Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6084004
3 March 2016 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5827274

Deficiency record · 34

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 March 2022 Resolved
A bilge high level alarm must be installed on vessels of at least 26ft in length and produce an audible and visual alarm in normally unmanned spaces. When testing each compartment bilge high level alarm, none produced an audible or visual alarm. The bilge high level junction box located in the lazarette also poored out water when examined. Repair or replace existing high water alarm system and ensure all junctions remain free of water accumulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 March 2022 Resolved
Existing vessels must be fitted with a general alarm public address system by March 11, 2001, or ten years after is keel was laid. Vessel did not have a system fitted and was missing exterior system where previously installed. Install general alarm and public address system for the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 March 2022 Resolved
One length of fire hose shall be provided for each fire hydrant and shall be 1 1/2 inch diameter and 50 feet in length in good serviceable condition. When testing the fire hoses, leaks and pinholes were found in the line while pressure testing. Replace existing fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 March 2022 Resolved
Each required Life Float must be fitted with at least 2 paddles of at least 4 feet in length and buoyant. One 12 man Life Float was missing a paddle. Acquire and additional paddle labeled specific to the vessel. Vessel passenger count is restricted not more than 24 passengers until a new paddle is installed.
Action required: 705 - Other - as specified
Resolved 21 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2022 Resolved
Life Float and Life Ring shall have approved retro-flective material evenly placed on the body of the device. All reflective material was worn and not fit for continued use. Place new reflective material on required items. Vessel is restricted to day-time operations until reflective material is replaced.
Action required: 705 - Other - as specified
Resolved 18 March 2022
Resolution: Corrected on the Spot.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2022 Resolved
At each inspection for certification and subsequent inspections, Marine Inspector shall require that all observed unsafe practices and hazardous situation be corrected. Identified 2 electrical grounds within the passenger accommodation. Repair electrical systems to eliminate electrical grounds
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 March 2022 Resolved
At each inspection for certification and subsequent inspections, Marine Inspector shall examine the bilges & other spaces for no accumulation of oil or other matter to create a fire hazard. Found hydraulic oil water accumulated in the bilge. Remove sitting oil and water.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2022 Resolved
A vessel of more than 65 feet in length must have at least one fire axe located in or adjacent to the primary operating station. Fire axe found in poor condition. Replace existing fire axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 March 2022 Resolved
A Hatch cover exposed to the weather deck must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other means to prevent loss. Hatch cover leading to the forward compartment was not attached and the existing chain heavily rusted. Re-attach chain or install new attachment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2022 Resolved
At each initial and subsequent inspection for certification, the Marine inspector will examine all accessible parts of the exterior and interior of the hull. Conducting the ISE, a crack was identified on the vessel port side bit mount below deck on the port side bit that penetrates the weather-deck connected to a horizontal stringer. Conduct permanent repairs at next Dry Dock.
Action required: 705 - Other - as specified
Resolved 21 September 2023
Resolution: Repairs to port side bit mount have been completed to the satisfaction of the Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 April 2021 Resolved
The condition of the vessel and its equipment must be acceptable to the cognizant OCMI. Vessel was found to have two holes in the hull and other suspect areas. Vessel must identify all areas of wastage and submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 14 April 2021
Resolved 3 May 2021
Resolution: All repairs were completed to the port, starboard, and aft side shell. All repairs were inspected using bleed through PT NDT method and passed visual inspection. //s// [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 April 2021 Resolved
Vessel must be provided with sufficient fire fighting systems. Fire pump is inoperable. Make effective repair.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 14 April 2021
Resolved 5 May 2021
Resolution: A rag was found in the firepump pick up line left behind by a shipyard worker. Removed obstruction, completed operational test, passed with proper PSI and hose test on deck. //s// [name withheld]
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 April 2021 Resolved
Spaces containing machinery shall be fitted with adequate ventilators to provide sufficient air for proper operation of main engines and auxiliary engines. Ventilation has been removed from machinery space and no adequate natural ventilation is provided. Vessel must install proper ventilation for the operation of main engines and auxiliary engines.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 14 April 2021
Resolved 5 May 2021
Resolution: Installed new ventilation blowers port and starboard side aft in engine room. Completed an operational test of blowers and passed inspection. //s// [name withheld]
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 April 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Audible alarm was inoperable. Make effective repair.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 14 April 2021
Resolved 5 May 2021
Resolution: Installed new bildge alarm. Completed an operational test of unit. Passed test. //s// [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2021 Resolved
Exhaust piping shall be gas tight throughout its length. Found exhaust leak on starboard generator. Make effective repair.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 14 April 2021
Resolved 5 May 2021
Resolution: replaced seal on exhuast. condected an operational test and found no leaks remained on the system. //s// [name withheld]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2021 Resolved
All electrical installations shall be to the satisfaction of the OCMI and recognized good marine standards and practices. Found dead end wires of transformer, power supplies not properly secured,improper use of extension chords, and corroded battery connections. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 5 May 2021
Resolution: Dead end wires of transformer were properly terminated. Power supplies not properly secured are now secured. Improper use of extension chords are removed and replaced with proper electrical wiring. Corroded battery connections were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 April 2021 Resolved
A vessel must carry adequate and up-to-date charts and navigation publications. Vessel did not have up-to-date charts or publications. Provide required charts and publications.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 5 May 2021
Resolution: All required charts and publications are on the vessel. //s// [name withheld]
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 31 May 2018 Resolved
Starboard Propulsion Generator (not engine, as listed above) Exhaust had numerous holes, allowing exhaust to enter the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2018
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 31 May 2018 Resolved
Numerous welds were found to be cracked at the exhaust exit point on the port and starboard sides of the vessel, enabling water ingress and weakening structural integrity
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2018
Construction/Loadline › Hull › Weld
Issued 31 May 2018 Resolved
Numerous cracked welds were discovered as follows: 03 in the forepeak, 02 in the galley void, 01 in the Lazarette and 01 on the base of the starboard rail of the vessel on deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2018 Resolved
Navigation lights (side lights) did not meet the appropriate 112.5 degree requirements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2018 Resolved
Navigation light housings were not painted matte black.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Engineering › Diesel Engine (propulsion-electric) › Seal
Issued 31 May 2018 Resolved
Port side generator (not engine as listed above) was found to be leaking oil.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018 Resolved
Dead end wires were discovered on both Port and Starboard Engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018 Resolved
Numerous splices were discovered throughout the vessel
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018 Resolved
Plastic zip ties were utilized to secure wiring throughout the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Electrical › Electrical Distribution System (service) › Switchboard
Issued 31 May 2018 Resolved
Switchboard labels were worn or missing, and as such were not appropriately labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Electrical › Electrical Distribution System (service) › Switchboard
Issued 31 May 2018 Resolved
Numerous open blanks were found on the switchboard, enabling potential accidental contact with uninsulated wiring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Engineering › Generator (propulsion-electric) › Battery
Issued 31 May 2018 Resolved
Batteries were found to be unsecured against vessel movement within their battery boxes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Engineering › Fuel Oil Service System › Hose
Issued 31 May 2018 Resolved
Secondary fuel hose by the fuel filter on teh STBD generator was found to be dry-rotted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Fire Fighting › Means of Escape › Escape Route Signs
Issued 31 May 2018 Resolved
Emergency Exit sign in the engine room was illegible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 2 July 2018
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 23 March 2017 Resolved
HAILING PORT ON VESSEL DOES NOT MATCH DOCUMENTATION. NEED TO CORRECTLY MARK HAILING PORT ON VESSEL. 46 CFR 185.602
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 21 April 2017
Resolution: Updated hailing port to Houston to match all documentation. All was satisfactory.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 23 March 2017 Resolved
ALL BREAKER PANELS NOT LABELED. LABEL BREAKER PANELS. 46 CFR 183.220(d)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 21 April 2017
Resolution: Labelled all breaker panels appropriately. All was satisfactory.
Lifesaving › Lifefloat › Approval
Issued 3 March 2016 Resolved
Vessel operators removed approved lifefloats and incorrectly installed liferafts. Vessel operator must return vessel to original and submit plan for liferaft installation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2016
Resolved 3 March 2016
Resolution: Vessel operator returned life floats to vessel as originally installed. Vessel rep will follow up with office to install liferafts properly.

Recorded names · 1

BELLAGIO (2007–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.