Inspection history · 53
10 December 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3112571
21 November 2007
Permit to Proceed
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3103044
19 June 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3006797
5 June 2006
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2702508
12 September 2005
Administrative Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2491125
30 March 2005
Examination of Repairs · Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2318582
30 March 2005
Periodic Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2332265
10 March 2005
Permit to Proceed · Examination of Repairs · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2306919
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1987819
4 September 2003
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1896360
9 June 2003
Internal Structural Exam · COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1812923
27 February 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1750482
11 December 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1718043
16 May 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1618887
12 February 2002
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1485973
14 March 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1060058
5 April 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816875
1 June 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 805415
15 April 1998
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1406305
5 November 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1120097
11 October 1997
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1110696
10 June 1997
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 774855
23 July 1996
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1084769
12 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108490
10 December 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 469622
28 August 1995
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1193505
30 April 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 105949
26 April 1995
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 863390
7 September 1994
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 865290
28 September 1993
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1156063
7 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 487607
7 December 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 826251
28 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 537666
12 February 1992
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1270787
21 November 1990
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1219617
30 April 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907600
23 April 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 913834
27 September 1989
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1329365
12 October 1988
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1202214
16 October 1987
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1325279
10 September 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1004320
30 December 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1005834
21 November 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 502975
21 November 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1020256
16 October 1986
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1013232
29 June 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 529401
23 October 1985
Credit Drydock · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1300430
15 May 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 475807
28 January 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 504611
10 October 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1283147
30 May 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 974022
18 May 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1280887
13 May 1982
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 972056
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 November 2007
Resolved
Pinhole leak located in the #3 cargo tank stripping line, approx 10 inches above the point of entry into the tank. Temp repair consist of epoxy patch secured w/FRP pipe wrap.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 December 2007
Resolution: Observed stainless steel repair of 2" stripping line.
Construction/Loadline › Hull › Hull Plating
Issued 4 September 2003
Resolved
Hull fractures in way of gunwales, deck and sideshell at various locations on barge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2003
Resolution: Three inserts and several fractures gouge and welded.
Construction/Loadline
Issued 11 October 1997
Resolved
Offload all cargo, proceed to Houston, Texas. Have forward rake gas freed and made ready for damage survey. Complete all repairs per damage survey to the satisfaction of the OCMI, Houston, Texas before any cargo operationstakes place.
Condition: Unknown
Due 11 October 1997
Resolved 11 October 1997
Electrical
Issued 21 November 1986
Resolved
REPLACE EXISTING 100 FOOT EXTENSION CORDS TO NAVIGATION LIGHTS WITH WIRING THAT MEETS THE STANDARDS OF 46 CFR 111.105-15 AND 46 CFR 111.75-18(E)(3).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Unknown
Issued 18 May 1984
Resolved
INSTALL SUITABLE GUARD OVER STRIPPING PUMP MOVING ASSEMBLY. INSTALLATION TOBE MADE TO COGNIZANT OCMI'S SATISFACTION PRIOR TO 01JUNE84.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 18 May 1984
Resolved
PRIOR TO LOADNG ACRYLONITRILE REPLACE ALL P/V VALVES (5 EACH) W/STAINLESS STEEL P/V VALVES. IAW 46CFR 151.05 TO COGNIZANT OCMI'S SATIS. PRIOR 18JUN84
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984