Records from 2005 to 2026. Most recent: inspection, 16 June 2026.
Inspection history · 38
16 June 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8410498
22 May 2026
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8378779
28 April 2026
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8357581
23 April 2026
Deficiency Check · Administrative Inspection · Damage Survey · Vessel Attendance
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8354985
30 September 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8244465
29 September 2025
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8244207
10 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8231061
2 August 2025
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8200644
2 August 2025
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8201393
30 July 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8198726
27 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8168979
21 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8163655
9 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8133139
13 March 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8093548
16 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8003429
26 August 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7989623
26 August 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8027825
21 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7881107
18 September 2023
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7794112
7 May 2023
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7706827
30 March 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7659645
29 September 2022
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7572529
22 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7457616
4 October 2021
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7328662
8 April 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7170643
11 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6974147
21 February 2020
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6914810
4 December 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6869933
22 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6843843
1 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6821233
11 May 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6682393
1 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6653980
24 September 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6549289
25 July 2018
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6490413
7 February 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6351512
5 April 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6118656
26 May 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5887782
17 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5817379
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2026
Resolved
Windows and airports must be fitted with frames of steel or equivalent material. Glazing beads or angles of steel or equivalent material must be installed to hold glass in place in windows or airports in a fire control boundary in event of a fire. Several windows were missing metal tabs to hold windows in place in the event of a fire. Replace tabs as needed to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2026
Resolution: Resolved to the satisfaction of a Marine Inspector
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2026
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 lbs) applied at any point. Deck railing on the stbd side aft towards the paddle wheel is broke. Make repairs to the satisfaction of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
Resolution: resolved to the satisfaction of the marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 June 2026
Resolved
A door must be capable of operation from either side by one person. Doors in the dining room and fwd deck were inoperable. Provide evidence that the doors are operating as normal to a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
Resolution: resolved to the satisfaction of the marine inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. May 22, 2026 vessel reported that their coupling failed on the STBD engine. Vessel is allowed to transit to Richland, Washington to conduct repairs. Repairs to the coupling failure must be made to the satisfaction of the Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2026
Resolution: Vessel port engineer called to report that the starboard coupling was replaced and the vessel conducted sea trills and everything was operating normally.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
April 23, 2026 Vessel reported inoperable starboard side z drive due to damage caused by fouling string of buoys. Vessel is allowed to transit to Umatilla, OR to conduct repairs, repairs must be made to the satisfaction of the attending Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2026
Resolution: MI's attended vessel to witness operational test of repairs to Z drive pump motors. Witnessed several tests pier side. Vessel master sent email stating that the system was functioning as designed upon departure from the pier later that night. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 30 September 2025
Resolved
Whenever there is a hazardous condition, as defined by § 114.400 of this chapter, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port of the port or place of destination and the Captain of the Port of the port or place in which the vessel is located of the hazardous condition. Reports and photos from the vessel show a diesel fuel leak on the starboard tank. Vessel is authorized to perform temporary repair according to the submitted repair proposal. Provide proof of repairs to the satisfaction of the MI, ensuring no hazardous conditions exist to the vessel or environment. Furthermore, provide a permanent repair plan for the fuel tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 30 September 2025
Resolution: Deficiency was resolved and photographs were attached of the repairs. worklist item added for future permanent repairs to starboard fuel tank.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 August 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The company reported an allision with the McNary Lock and Dam while transiting upriver on the Columbia River. Pictures from the allision show evidence of damage to the rub rails and possible hull integrity on the starboard amidship main deck. Vessel shall make temporary repairs to railings to prevent man overboard incidents. Additionally vessel engineers shall conduct increased rounds. Vessel shall be made available for a damage survey with a Coast Guard Marine Inspector at the earliest oppotunity.
*Permenent repairs must be affected prior to carrying passengers in the 2026 operating season.*
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 February 2026
Resolution: Received photos of final repairs, see documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel reported overheating of the Port Azimuth Thruster coupling Vessel moored at Port of Umatilla and conducted repairs to the coupling, tested operation satisfactory. Vessel is to provide a report and evidence of permanent repairs to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 28 June 2025
Resolved 27 June 2025
Resolution: Inspected new coupling and found installation satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is
installed and capable of operat ing at constant marine
load under such requirements without exceeding its
designed limitations. Sector Columbia River received a
report from the AMERICAN WEST that they experienced a
loss propulsion due to a failure of the pump that
services their day tank. You are to make repairs to the
affected fuel pump and prove proper operation to a
Marine Inspector. Complete prior to getting underway
with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: The Daytank Low Level alarm is operating audibly and visually in both the control room and wheel house. All connections were tightened and a relay was replaced. Tech report provided under deficiencies->documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2023
Resolved
High risk service spaces (9) include - (5) Cleaning gear locker or small storeroom in an accommodation area;
(a)(2)Bulkheads and decks must be classed as A-60, A-30, A-15, A-0, B-15, B-0, C, or C' based on the following: (i) A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. Table 116.415 (b) shows that high risk service spaces leading to high risk accommodation must be an A-60 boundary and to low risk accommodation A-15 boundary. In the crew accommodation spaces, attending marine inspector observed two accommodation spaces converted to storage space with linens. The converted spaces did not have doors or means of preventing spread of fire. Marine inspector observed this space conversion may potentially affect vessel tonnage. Reattach doors to the two storage spaces to ensure it meets boundary requirements.
46 CFR 114.400
46 CFR 11.415 (a)(2)
46 CFR 116.415 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2023
Resolved 21 March 2024
Resolution: Rooms were converted back to accommondation spaces, combustibles removed and fire doors installed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 March 2023
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. Fire damper in the aft engine room bulkhead was blocked open with a pry bar. This damper was found wired open during the MAR 30 inspection this year.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 April 2023
Resolved 21 April 2023
Resolution: Crew removed the pry bar and tested the fire damper.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2020
Resolved
Each battery installation must be protected from falling
objects. Install a cover for the top of the battery bank
located on the port side of the auxiliary machinery
space and repair the connection to the battery from the
charger.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2020
Resolved 20 May 2021
Resolution: Battery covers were in place.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 April 2019
Resolved
Significant rust scaling and rust of the hull plate found forward of the auxiliary machinery space off frame 10. It was also noted that 5 of the 6 intercostal longitudinal stringers were wasted beyond repair. Temporary repairs have been installed by welding temporary stiffeners and installing reinforced concrete patches in the areas of corrosion on the hull plate.
Make permanent repairs to the shell plate and supporting structure around the sewage treatment tank in the axillary machinery space. Until this is completed.
limit the filling of the chlorine tank to be done only by qualified personnel. A wide mouth funnel will be used to mitigate chlorine from getting into the bilge.
The crew must make hourly rounds of the axillary machinery space.
As proposed have a third party vendor conduct monthly UT soundings of the affected area while the vessel is in operation this season. Provide the results to MSU Portland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 20 December 2019
Resolution: The hull plating and associated transverse and logitudinal stiffners were renewed underneath the MSD in the forward machinery space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
The placarding on the main deck entrance to the elevator reflects six (6) persons as the maximum capacity allowed. The certification provided to the CG after the elevator was tested in April indicates the passenger elevator was tested to a maximum of four (4) persons or 1000lbs. Immediately properly Placard the elevator as indication on the test certification.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 July 2018
Resolved 27 July 2018
Resolution: Master Certified that the elevator is properly placarded as per the latest elevator servicing certificate.
Engineering › Steering Gear System › Feedback Unit
Issued 13 April 2018
Resolved
Starboard main propulsion drive is inoperable. Make repairs and conduct satisfactory underway test of the vessel's starboard main propulsion drive in the presence of a CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Feedback potentiometer replaced. Witnessed satisfactory operation of the starboard drive/steering system.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 April 2018
Resolved
Conduct a satisfactory man overboard drill in the presence of attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Witnessed satisfactory MOB recovery drill to include launching and recovery of rescue boat.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 April 2018
Resolved
Remove the excess flammable liquids from 04 deck areas to include paint thinner on top of port bridge wing battery bank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Witnessed removal of all flammable liquids from 04 deck area & battery bank on port bridge wing.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 April 2018
Resolved
Elevator is inoperable. Repairs must be made by a certified technician and operational test conducted in the presence of a CG marine inspector prior to using the elevator for passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2018
Resolution: Witnessed satisfactory test of elevator and reviewed satisfactory technician's servicing report.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 April 2018
Resolved
Ring buoy grab lines & float light lines require replacement on both port & starboard wheelhouse ring buoys.
Action required: 10 - Deficiency Rectified
Due 13 May 2018
Resolved 25 May 2018
Resolution: Received photo evidence of satisfactory replacement of ring buoy grab lines & float light lines on both port & starboard wheelhouse ring buoys.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 13 April 2018
Resolved
Appropriately fill cable transit in lower machinery space overhead to space aft of scullery with USCG approved material.
Due 13 May 2018
Resolved 25 May 2018
Resolution: Received photo evidence of satisfactory instllation of approved firestop materials in lower machinery space overhead to space aft of scullery.
Electrical › Lighting (service) › Conductor
Issued 13 April 2018
Resolved
Make proper repairs/splice to fluorescent light wiring under aft 04 deck covered area.
Action required: 10 - Deficiency Rectified
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed satisfactory repairs made to to overhead fluorescent light wiring under aft 04 deck covered area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2018
Resolved
Make proper repairs/splices to dead end wire and capped wires under aft deck piano.
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed dead end wires and capped wires under aft deck piano removed. All sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 April 2018
Resolved
Replace broken cover on A/C electrical outlet located in 04 deck starboard storage closet.
Due 13 May 2018
Resolved 14 April 2018
Resolution: New cover installed on A/C electrical outlet located in 04 deck starboard storage closet. All sat.
Construction/Loadline › Structures › Door
Issued 13 April 2018
Resolved
Forward lounge door on main deck missing uppermost securing device.
Due 13 May 2018
Resolved 14 April 2018
Resolution: New securing device installed on forward lounge door on main deck. All sat.
Construction/Loadline › Structures › Superstructure
Issued 13 April 2018
Resolved
Forward lounge windows, starboard side, are missing exterior securing clips.
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed new exterior window clips installed on forward lounge windows. All sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 June 2016
Resolved
Provide a valid FCC Communications Act Safety Radiotelephony Certificate and an FCC Vessel Bridge-To-Bridge Radiotelephony Certificate.
Due 3 June 2016
Resolved 7 June 2016
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 June 2016
Resolved
Prove proper operation of rescue boat's outboard engine.
Condition: Improper/Lack of Maintenance
Due 3 July 2016
Resolved 3 June 2016