AMERICAN WEST

AMERICAN WEST is a 1995 passenger vessel (inspected). The Coast Guard has recorded 200 inspections since 1995, most recently in June 2026, along with 226 deficiencies and 15 casualty investigations between 2005 and 2025.

Records from 1995 to 2026. Most recent: inspection, 16 June 2026.

Built
1995
Last inspected
16 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8642957 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF4506
414949
Flag
UNITED STATES
367452710
Maury page id
psix-414949

Inspections, by type

…with no type recorded94
Years with a record 28 calendar years (1995–2026)
The 200 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)221.3 ft × 41.3 ft × 10.0 ft
Registered tonnagegross 92 / net 92
ITC dimensions (L × B × D)221.3 ft × 41.3 ft × 10.0 ft
ITC tonnagegross 2,115 / net 776
BuilderNICHOLS BROTHERS BOAT · FREELAND, WA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2115 - Convention (Subpart B), Gross Ton
92 - Regulatory (Subpart C or D), Gross Ton
776 - Convention (Subpart B), Net Ton
92 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF4506MMSI 367452710 · active · compulsorily equipped · granted 8 May 2020, expires 18 May 2030
WDB4794MMSI 366902430 · expired · compulsorily equipped · granted 22 July 2003, cancelled 21 September 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GAMBLER Towing Vessel · MISLE 98071 · 8 April 2008 · activity 3179829CINDY B Towing Vessel · MISLE 53452 · 17 June 2003 · activity 1822383CAPTAIN BOB Towing Vessel · MISLE 125814 · 17 June 2003 · activity 1822383

Inspection history · 200

16 June 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8410498
22 May 2026 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8378779
28 April 2026 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8357581
23 April 2026 Deficiency Check · Administrative Inspection · Damage Survey · Vessel Attendance
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8354985
30 September 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8244465
29 September 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8244207
10 September 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8231061
2 August 2025 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8200644
2 August 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8201393
30 July 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8198726
27 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8168979
21 June 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8163655
9 May 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8133139
13 March 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8093548
16 September 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8003429
26 August 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7989623
26 August 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8027825
21 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7881107
18 September 2023 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7794112
7 May 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7706827
30 March 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7659645
29 September 2022 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7572529
22 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7457616
4 October 2021 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7328662
8 April 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7170643
11 June 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6974147
21 February 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6914810
4 December 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6869933
22 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6843843
1 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6821233
11 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6682393
1 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6653980
24 September 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6549289
25 July 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6490413
7 February 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6351512
5 April 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6118656
26 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5887782
17 February 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5817379
25 September 2015 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5728867
24 September 2015 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5737458
23 September 2015 Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5727892
29 June 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4951551
5 June 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4880422
16 September 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4149084
6 July 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4062915
30 December 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3389678
12 September 2008 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3323394
12 September 2008 Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3325333
12 September 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326356
25 August 2008 Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3308699
18 August 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3304826
9 June 2008 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3189661
20 May 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3211938
12 May 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3205417
8 April 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3179681
8 April 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179829
8 April 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3189369
4 April 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3135673
14 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3147489
19 October 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3084643
13 October 2007 Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3079113
13 October 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3195782
28 September 2007 In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3068349
18 July 2007 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2998628
10 April 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2906158
29 March 2007 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2897197
18 September 2006 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2781556
18 September 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2782413
24 August 2006 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2757771
22 August 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2763327
11 May 2006 Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2644210
15 March 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2561679
25 January 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2573926
16 August 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2464902
14 August 2005 Damage Survey · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2463784
29 June 2005 Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2415515
23 June 2005 Deficiency Check · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2443121
26 April 2005 Deficiency Check · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2433358
24 February 2005 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2305319
3 August 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2154792
22 June 2004 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2107344
25 May 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2077786
10 May 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2065743
26 April 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2052941
24 April 2004 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2053326
8 April 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2019042
17 August 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1888002
13 August 2003 Examination of Repairs · Permit to Proceed · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1877318
13 August 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2047575
8 August 2003 Deficiency Check · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1877088
5 August 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1985660
19 June 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1821610
17 June 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1822383
11 June 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1647740
1 May 2003 Deficiency Check · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1785053
1 May 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1827373
26 April 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1782060
11 February 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1742912
9 January 2003 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1715079
9 September 2002 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1673815
11 June 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1638415
23 May 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1618588
20 March 2002 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1597190
20 March 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1749247
3 March 2002 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1597170
28 February 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1490549
4 January 2002 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1475570
15 December 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1485696
15 November 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1076140
10 October 2001 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1074340
4 October 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1074524
2 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 53153
18 February 2001 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1423519
17 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 60151
12 February 2001 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1408671
1 January 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 43580
28 August 2000 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1451602
4 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 145237
20 June 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 29682
23 May 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 101147
6 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 67084
14 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1046209
12 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 731715
10 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 66882
10 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 131270
1 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 43854
12 February 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 74729
12 February 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384367
14 January 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369467
16 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 812568
9 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 133360
9 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369436
28 November 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 68956
13 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 7998
3 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 30722
29 June 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 48942
9 May 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 100850
9 May 1999 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1375778
6 May 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 68610
22 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 95798
18 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 66148
17 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 137174
15 April 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1124805
5 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 168741
2 March 1999 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1473382
15 January 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811257
3 December 1998 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 805352
26 November 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 71964
5 November 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 804298
22 October 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 808820
21 October 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 86957
9 September 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 122598
25 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 34425
25 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 58067
27 July 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 69067
25 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 120414
14 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 5230
1 June 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795594
14 May 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1126516
18 April 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 84303
17 April 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372222
3 April 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1123122
19 March 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 90312
13 March 1998 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1430519
11 March 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 80258
11 March 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 204594
11 March 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765737
14 December 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786289
25 September 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1396808
28 June 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1411499
15 May 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106702
21 April 1997 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1409666
20 April 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 142330
23 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 164750
15 March 1997 Deficiency Check · Examination of Repairs · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1421331
21 February 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356099
18 February 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 41286
2 December 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 874258
17 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 148639
14 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 713042
10 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 129939
1 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 30172
29 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 129056
29 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 213765
27 September 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 838811
9 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 156572
7 September 1996 Examination of Repairs · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385812
6 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 159292
4 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 8014
22 August 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1086421
3 July 1996 Examination of Repairs · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1353955
29 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 58147
12 April 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1466418
5 April 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 82849
15 March 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 8166
14 March 1996 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428614
9 December 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 152169
22 September 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 64439
25 August 1995 Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385571
17 August 1995 Initial Construction-Excluding Oversight · Inclining Experiment · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363121

Deficiency record · 226

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2026 Resolved
Windows and airports must be fitted with frames of steel or equivalent material. Glazing beads or angles of steel or equivalent material must be installed to hold glass in place in windows or airports in a fire control boundary in event of a fire. Several windows were missing metal tabs to hold windows in place in the event of a fire. Replace tabs as needed to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2026
Resolution: Resolved to the satisfaction of a Marine Inspector
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2026 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 lbs) applied at any point. Deck railing on the stbd side aft towards the paddle wheel is broke. Make repairs to the satisfaction of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
Resolution: resolved to the satisfaction of the marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 June 2026 Resolved
A door must be capable of operation from either side by one person. Doors in the dining room and fwd deck were inoperable. Provide evidence that the doors are operating as normal to a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
Resolution: resolved to the satisfaction of the marine inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. May 22, 2026 vessel reported that their coupling failed on the STBD engine. Vessel is allowed to transit to Richland, Washington to conduct repairs. Repairs to the coupling failure must be made to the satisfaction of the Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2026
Resolution: Vessel port engineer called to report that the starboard coupling was replaced and the vessel conducted sea trills and everything was operating normally.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. April 23, 2026 Vessel reported inoperable starboard side z drive due to damage caused by fouling string of buoys. Vessel is allowed to transit to Umatilla, OR to conduct repairs, repairs must be made to the satisfaction of the attending Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2026
Resolution: MI's attended vessel to witness operational test of repairs to Z drive pump motors. Witnessed several tests pier side. Vessel master sent email stating that the system was functioning as designed upon departure from the pier later that night. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 30 September 2025 Resolved
Whenever there is a hazardous condition, as defined by § 114.400 of this chapter, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port of the port or place of destination and the Captain of the Port of the port or place in which the vessel is located of the hazardous condition. Reports and photos from the vessel show a diesel fuel leak on the starboard tank. Vessel is authorized to perform temporary repair according to the submitted repair proposal. Provide proof of repairs to the satisfaction of the MI, ensuring no hazardous conditions exist to the vessel or environment. Furthermore, provide a permanent repair plan for the fuel tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 30 September 2025
Resolution: Deficiency was resolved and photographs were attached of the repairs. worklist item added for future permanent repairs to starboard fuel tank.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 August 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The company reported an allision with the McNary Lock and Dam while transiting upriver on the Columbia River. Pictures from the allision show evidence of damage to the rub rails and possible hull integrity on the starboard amidship main deck. Vessel shall make temporary repairs to railings to prevent man overboard incidents. Additionally vessel engineers shall conduct increased rounds. Vessel shall be made available for a damage survey with a Coast Guard Marine Inspector at the earliest oppotunity. *Permenent repairs must be affected prior to carrying passengers in the 2026 operating season.*
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 February 2026
Resolution: Received photos of final repairs, see documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported overheating of the Port Azimuth Thruster coupling Vessel moored at Port of Umatilla and conducted repairs to the coupling, tested operation satisfactory. Vessel is to provide a report and evidence of permanent repairs to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 28 June 2025
Resolved 27 June 2025
Resolution: Inspected new coupling and found installation satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operat ing at constant marine load under such requirements without exceeding its designed limitations. Sector Columbia River received a report from the AMERICAN WEST that they experienced a loss propulsion due to a failure of the pump that services their day tank. You are to make repairs to the affected fuel pump and prove proper operation to a Marine Inspector. Complete prior to getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: The Daytank Low Level alarm is operating audibly and visually in both the control room and wheel house. All connections were tightened and a relay was replaced. Tech report provided under deficiencies->documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2023 Resolved
High risk service spaces (9) include - (5) Cleaning gear locker or small storeroom in an accommodation area; (a)(2)Bulkheads and decks must be classed as A-60, A-30, A-15, A-0, B-15, B-0, C, or C' based on the following: (i) A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. Table 116.415 (b) shows that high risk service spaces leading to high risk accommodation must be an A-60 boundary and to low risk accommodation A-15 boundary. In the crew accommodation spaces, attending marine inspector observed two accommodation spaces converted to storage space with linens. The converted spaces did not have doors or means of preventing spread of fire. Marine inspector observed this space conversion may potentially affect vessel tonnage. Reattach doors to the two storage spaces to ensure it meets boundary requirements. 46 CFR 114.400 46 CFR 11.415 (a)(2) 46 CFR 116.415 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2023
Resolved 21 March 2024
Resolution: Rooms were converted back to accommondation spaces, combustibles removed and fire doors installed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 March 2023 Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. Fire damper in the aft engine room bulkhead was blocked open with a pry bar. This damper was found wired open during the MAR 30 inspection this year.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 April 2023
Resolved 21 April 2023
Resolution: Crew removed the pry bar and tested the fire damper.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2020 Resolved
Each battery installation must be protected from falling objects. Install a cover for the top of the battery bank located on the port side of the auxiliary machinery space and repair the connection to the battery from the charger.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2020
Resolved 20 May 2021
Resolution: Battery covers were in place.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 April 2019 Resolved
Significant rust scaling and rust of the hull plate found forward of the auxiliary machinery space off frame 10. It was also noted that 5 of the 6 intercostal longitudinal stringers were wasted beyond repair. Temporary repairs have been installed by welding temporary stiffeners and installing reinforced concrete patches in the areas of corrosion on the hull plate. Make permanent repairs to the shell plate and supporting structure around the sewage treatment tank in the axillary machinery space. Until this is completed. limit the filling of the chlorine tank to be done only by qualified personnel. A wide mouth funnel will be used to mitigate chlorine from getting into the bilge. The crew must make hourly rounds of the axillary machinery space. As proposed have a third party vendor conduct monthly UT soundings of the affected area while the vessel is in operation this season. Provide the results to MSU Portland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 20 December 2019
Resolution: The hull plating and associated transverse and logitudinal stiffners were renewed underneath the MSD in the forward machinery space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018 Resolved
The placarding on the main deck entrance to the elevator reflects six (6) persons as the maximum capacity allowed. The certification provided to the CG after the elevator was tested in April indicates the passenger elevator was tested to a maximum of four (4) persons or 1000lbs. Immediately properly Placard the elevator as indication on the test certification.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 July 2018
Resolved 27 July 2018
Resolution: Master Certified that the elevator is properly placarded as per the latest elevator servicing certificate.
Engineering › Steering Gear System › Feedback Unit
Issued 13 April 2018 Resolved
Starboard main propulsion drive is inoperable. Make repairs and conduct satisfactory underway test of the vessel's starboard main propulsion drive in the presence of a CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Feedback potentiometer replaced. Witnessed satisfactory operation of the starboard drive/steering system.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 April 2018 Resolved
Conduct a satisfactory man overboard drill in the presence of attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Witnessed satisfactory MOB recovery drill to include launching and recovery of rescue boat.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 April 2018 Resolved
Remove the excess flammable liquids from 04 deck areas to include paint thinner on top of port bridge wing battery bank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2018
Resolution: Witnessed removal of all flammable liquids from 04 deck area & battery bank on port bridge wing.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 April 2018 Resolved
Elevator is inoperable. Repairs must be made by a certified technician and operational test conducted in the presence of a CG marine inspector prior to using the elevator for passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2018
Resolution: Witnessed satisfactory test of elevator and reviewed satisfactory technician's servicing report.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 April 2018 Resolved
Ring buoy grab lines & float light lines require replacement on both port & starboard wheelhouse ring buoys.
Action required: 10 - Deficiency Rectified
Due 13 May 2018
Resolved 25 May 2018
Resolution: Received photo evidence of satisfactory replacement of ring buoy grab lines & float light lines on both port & starboard wheelhouse ring buoys.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 13 April 2018 Resolved
Appropriately fill cable transit in lower machinery space overhead to space aft of scullery with USCG approved material.
Due 13 May 2018
Resolved 25 May 2018
Resolution: Received photo evidence of satisfactory instllation of approved firestop materials in lower machinery space overhead to space aft of scullery.
Electrical › Lighting (service) › Conductor
Issued 13 April 2018 Resolved
Make proper repairs/splice to fluorescent light wiring under aft 04 deck covered area.
Action required: 10 - Deficiency Rectified
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed satisfactory repairs made to to overhead fluorescent light wiring under aft 04 deck covered area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2018 Resolved
Make proper repairs/splices to dead end wire and capped wires under aft deck piano.
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed dead end wires and capped wires under aft deck piano removed. All sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 April 2018 Resolved
Replace broken cover on A/C electrical outlet located in 04 deck starboard storage closet.
Due 13 May 2018
Resolved 14 April 2018
Resolution: New cover installed on A/C electrical outlet located in 04 deck starboard storage closet. All sat.
Construction/Loadline › Structures › Door
Issued 13 April 2018 Resolved
Forward lounge door on main deck missing uppermost securing device.
Due 13 May 2018
Resolved 14 April 2018
Resolution: New securing device installed on forward lounge door on main deck. All sat.
Construction/Loadline › Structures › Superstructure
Issued 13 April 2018 Resolved
Forward lounge windows, starboard side, are missing exterior securing clips.
Due 13 May 2018
Resolved 14 April 2018
Resolution: Witnessed new exterior window clips installed on forward lounge windows. All sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 June 2016 Resolved
Provide a valid FCC Communications Act Safety Radiotelephony Certificate and an FCC Vessel Bridge-To-Bridge Radiotelephony Certificate.
Due 3 June 2016
Resolved 7 June 2016
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 June 2016 Resolved
Prove proper operation of rescue boat's outboard engine.
Condition: Improper/Lack of Maintenance
Due 3 July 2016
Resolved 3 June 2016
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 27 September 2015 Resolved
Prove proper operation of both Z drives L/O flow and elvel alarms, provide tech report from ZF.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 27 September 2015
Resolution: ZF corrected improper wiring and all alarms are working properly.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 September 2015 Resolved
Replace missing lighting fixture cover in lower engine room under stbd main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 6 October 2015
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 27 September 2015 Resolved
Replace plugs for port and stbd side fuel vent combing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 6 October 2015
Electrical › Electrical Distribution System (service) › Cable
Issued 27 September 2015 Resolved
Remove box fans from galley ventilation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 6 October 2015
Construction/Loadline › Hull › Keel
Issued 26 September 2015 Resolved
Make permanent repairs to leaks in center vertical keel cooler prior to 2016 passenger operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 24 February 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 September 2015 Resolved
Ensure all main deck receptacle covers are watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 6 October 2015
Electrical › Electric Generation Source (service) › Generator
Issued 15 September 2008 Resolved
Repair as original and prove proper operation of emergency electrical system. System includes, but is not limited to electrical transformer, batteries, and inverter, supplying power for emergency lighting and navigation lights. Until this item is completed, vessel is restricted to operating underway only during daylight hours and must be moored to a shore side dock during hours of darkness.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2008
Resolved 15 September 2008
Electrical › Electric Supply System (service) › Transformer
Issued 12 September 2008 Resolved
Conduct repairs and prove proper operation of failed generator. To clear deficiency provide signed statement by master and chief engineer describing failure, repairs, and tests conducted to ensure proper operation prior to getting underway.
Condition: Unknown
Due 12 September 2008
Resolved 12 September 2008
Construction/Loadline › Structures › Deck Plating
Issued 25 August 2008 Resolved
Vessel was transiting into a lock when the current turned the vessel causing the aft starboard side to come into contact with the wall. Aft deck had buckled and one handrail stanchion was broken close to the deck just forward of the paddlewheel cantilever.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 March 2011
Resolved 10 May 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 April 2008 Resolved
Label CO2 manual actuation access door. 46 CFR 118.410 Complete prior to 07/09/08
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 5 August 2010
Electrical › Electrical Distribution System (service) › Busway
Issued 8 April 2008 Resolved
Replace all plastic wire ties securing wire runs to bulkheads in the engineroom. Wires may be bundled with plastic ties but must be secured to bulkheads and overhead with metal bands or clamps not more than 24” apart. 46 CFR 120.340(b)4 Complete prior to 07/09/08
Action required: 705 - Other - as specified
Due 30 March 2011
Resolved 10 May 2011
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 8 April 2008 Resolved
Re-install clips holding windows in the paddlewheel lounge area, including missing mounting studs. Complete prior to 07/09/08
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 5 August 2010
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 8 April 2008 Resolved
Re-route piping from Starboard main diesel engine coolant head tank. The current arrangement has the pipe tightly bound against the bulkhead and engine. This may lead to the fitting failing prematurely. 46 CFR 115.804(c) Complete prior to 07/09/08
Due 9 July 2008
Resolved 5 August 2010
Communications › Alarms/Indicators › Propeller Pitch Position Indicator
Issued 8 April 2008 Resolved
Starboard wing bridge control audible alarm does not sound. Renew failed components. If starboard wing bridge control is used for maneuvering station personnel in the wheelhouse to relay active alarms to the operator. 46 CFR 115.804(i) Complete prior to 07/09/08
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 5 August 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 April 2008 Resolved
Relocate all cable splices associated with the lower crew city head vent fans so that thay are all in proper enclosures (connector boxes) per 46 CFR 120.340(g) to be completed no later than 07Jul08.
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 5 August 2010
Electrical › Electrical Distribution System (service) › Switch
Issued 8 April 2008 Resolved
Remount all connector boxes for the gray and black water lift pumps controllers (located in the lower crew city center bilge void) to there mounting brackets. Replace all broken boxes and reseal their covers. 46 CFR 120.340. To be completed no later than 07jul08
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 5 August 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 8 April 2008 Resolved
Provide proper mount supports for each crew head vent fan located behind the head FRP modules, so that the fans are no longer supported by the vent tubing and in several cases, by ropes attached to the overhead. 46 CFR 116. to be completed no later than 07Aug08
Action required: 705 - Other - as specified
Due 7 August 2008
Resolved 5 August 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 8 April 2008 Resolved
Provide CG Marine Safety Center approved plans to modify the ventilation system for the lower crew city space so that all crew head exhaust fans vent directly to the vessels exterior. Currently, all vents discharge into the bilge space beneath the crew city compartment. Upon approval, all modifications must be made to the satisfaction of the attending CG Marine Inspector. 46 CFR 116. To be complet
Action required: 705 - Other - as specified
Due 30 March 2011
Resolved 10 May 2011
Accommodation/Occupational Safety › Ventilation › General
Issued 8 April 2008 Resolved
Prove proper operation of the exhaust ventilation fan located on the starboard side of the vessel in the main laundry space aft of crew city. 46 CFR 116. To be completed no later than 07Jul08
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 5 August 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 April 2008 Resolved
Modify emergency fuel shut off valve, port side hold deck behind clothes dryers, so that the valve operates with a single action (eliminate ratchet).
Due 4 May 2008
Resolved 9 June 2008
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 19 October 2007 Resolved
Re-locate, label, and demonstrate proper operation of fuel oil transfer pump emergency shut down.
Due 19 March 2008
Resolved 5 August 2010
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 13 October 2007 Resolved
Complete repairs and engine trials prior to operation with passengers on the port main engine, provide written service report to OCMI.
Due 30 October 2007
Resolved 13 October 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 13 October 2007 Resolved
Prior to departure from Astoria with passengers, provide a transit plan to OCMI/COTP for review and approval.
Due 30 October 2007
Resolved 13 October 2007
Resolution: Repairs complete, no plan required.
Engineering › Lubricating Oil Service System › Piping
Issued 17 July 2007 Resolved
Provide written proposal for repairs to the stbd hydraulic unit piping. Welded repairs to piping assembly shall be inspected both internally and externally. A Hydrostatic test of 1.5 times the maximum allowable working pressure shall be conducted IAW 46 CFR 56.97-30 and to the satisfaction of the attending CG Marine Inspector.
Due 18 July 2007
Resolved 18 July 2007
Resolution: Corrected
Engineering › Fuel Oil Service System › Piping
Issued 29 March 2007 Resolved
Provide drawings for review and approval for all new fuel transfer piping, coolers, day tank, etc... in the generator room.
Due 29 April 2007
Resolved 19 October 2007
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 29 March 2007 Resolved
Provide drawing for new generator control/gauge boxes adjacent to generators.
Due 29 April 2007
Resolved 19 October 2007
Engineering › Diesel Engine (auxiliary) › Governor
Issued 29 March 2007 Resolved
Demonstrate operation of diesel generator tachometers in generator room.
Due 29 April 2007
Resolved 19 October 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2007 Resolved
Remove or end in junction box dead ended improper wiring starboard side of main hydraulic tank behind starboard main engine.
Due 29 April 2007
Resolved 19 October 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 March 2007 Resolved
Satisfy structural issues outlined in Marine Safety Center letter H2-0700936 of 27MAR07.
Due 29 April 2007
Resolved 5 August 2010
Engineering › Diesel Engine (propulsion-electric) › Piston Ring
Issued 18 September 2006 Resolved
Received call from Master stating that the starboard main diesel engine experienced a large oil leak and was shut down. The Cummins Tech rep later found a seized piston and connecting rod. Prove proper operation of the engine prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2006
Resolved 23 September 2006
Resolution: Corrected
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 18 September 2006 Resolved
Prove Proper operation of starboard Main Diesel Engine upon making all necessary repairs. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2006
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 23 August 2006 Resolved
Vsl is to proceed on its current voyage from Snake River, WA to port of Longview, WA under its own power w/ tug escort, w/ 138 passengers & 46 crew members on board, per plan submitted to this office on 23AUG06. It is understood that vsl will be escorted by Shaver tug UMATILLA. Vsl will contact USCG Sector Portland IAW the comm plan outlined in submitted Req For Alt Vessel Itinerary plan.
Condition: Unknown
Due 30 August 2006
Resolved 24 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 23 August 2006 Resolved
Prove proper operation of the port side propulsion system upon completing all necessary repairs to the port paddlewheel gear box. Upon arrival in Longview, WA on or before 24AUG06, the vessel may not get underway with passengers until this item has been satisfied. This will require that the vessel proceed underway with marine inspector(s) on board for a trial run to test the repairs.
Condition: Unknown
Due 30 August 2006
Resolved 24 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 23 August 2006 Resolved
Make permanent repairs to leaks reported in the closed jacket water cooling system on the stbd main diesel engine. Upon arrival in Longview, WA on or before 24AUG06, the vessel may not get underway with passengers until this item is satisfied.
Due 30 August 2006
Resolved 24 August 2006
Electrical › Electric Generation Source (service) › Generator
Issued 8 May 2006 Resolved
Make permanent repairs to the port generator. Until such repairs are completed, the vessel will operate with tug assistance with pasengers allowed as detailed in the plan submitted.
Condition: Unknown
Due 12 May 2006
Resolved 11 May 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2006 Resolved
Provide proof of current FCC marine radio operator licenses for both masters. 47 CFR 80
Due 15 July 2006
Resolved 19 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 March 2006 Resolved
Provide 7 additional Type I CG approved PFD's (to achieve a total of 217 on board). Vessel limited to carrying NMT 210 adults until cleared.
Condition: Unknown
Due 15 April 2006
Resolved 23 May 2006
Electrical › Electric Generation Source (service) › Number of Sources
Issued 12 August 2005 Resolved
Prove proper operation of the port SSDG, to the satisfaction of the attending marine inspector. 46 CFR 120.310/120.312 No passengers may be carried u/w until requirement is corrected. As a condition of satisfying this requirement, the vsl should provide substantial findings to explain how casualty occurred.
Condition: Unknown
Due 16 August 2005
Resolved 14 August 2005
Resolution: Operational test conducted satisfactory.
Engineering › Steering Gear System › Ram
Issued 29 June 2005 Resolved
Make permanent repairs and demonstrate operations of steering in the presence of a cognizant CG marine inspector prior to the carrying of passengers. Loss of hydraulic fluid in port ram due to a possible blown seal or out of tolerance rod.
Due 29 June 2005
Resolved 30 June 2005
Resolution: Inspected installation of new Ram, looked at hydraulic lines, pins and mounting bolts. Witnessed functional operation of steering in all control functions at the rudders port and stbd and at the steering gear space.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 23 June 2005 Resolved
Make permanent repairs to hydraulic line where leaking from a fractured weld, and make repairs available for CG inspection. This item must be completed prior to operation with passengers.
Due 23 June 2005
Resolved 23 June 2005
Engineering › Steering Gear System › Solenoid Valve
Issued 29 April 2005 Resolved
Lay to Clarkston, Washington under tug assist. Provide copy of technician's report indicating cause of failure and repairs made to correct steering casualty. Provide copy of statement from the Master indicating that all testing of the steering system (post repair) has been completed and found satisfactory. Until this item is cleared, vessel is to remain moored in the port of Clarkston, WA.
Due 29 April 2005
Resolved 29 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2005 Resolved
Properly repair terminal block for propulsion hydraulic tank temperature probe.
Condition: Improper/Lack of Maintenance
Due 24 March 2005
Resolved 10 March 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 24 February 2005 Resolved
Properly install brackets/supports on port&stbd electrical cable connection to main generator fuel control.
Condition: Unknown
Due 24 March 2005
Resolved 10 March 2005
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 February 2005 Resolved
Properly install, repair and test latches/holds on galley fire doors (fwd). item to be cleared prior to teh carriage of passengers.
Condition: Unknown
Due 24 March 2005
Resolved 25 February 2005
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 24 February 2005 Resolved
Re-mount heat detector in lower engine room with a proper conn. box (currently held in place with zip-ties).
Condition: Improper Installation
Due 24 March 2005
Resolved 25 March 2005
Engineering › Reduction Gearing/Clutches
Issued 24 April 2004 Resolved
Provide a copy of condition found report, detailing findings relating to the failure of the stbd propulsion drive gear box, to MSO Portland, OR inspection office (attn: H. O'Sullivan). LEGACY COMPONENT DESC: Gear
Condition: Unknown
Due 24 May 2004
Resolved 25 May 2004
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 April 2004 Resolved
Restore missing A-60 SFP insulation in the engine control booth, stbd long. blkhd, fwd portion in way of the galley. 46 CFR 72.05-10 /NVIC 4-83 /NVIC 9-97 LEGACY COMPONENT DESC: Bulkheads - Control Stations
Condition: Improper Installation
Due 16 December 2004
Resolved 24 February 2005
Lifesaving › Work Vest
Issued 8 April 2004 Resolved
Replace seven of the eight buoyant work vests assigned for use by rescue boat crew and launching detail (paint damage, torn, weld damage). 46 CFR 115.808(a)
Condition: Improper/Lack of Maintenance
Due 8 May 2004
Resolved 25 May 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 April 2004 Resolved
Submit a proposal & complete repairs associated with a) perm. repairs to aft potable water storage tank (due to over-pressurizing); b) modify venting/over-fill protection so that relieving capacity prohibits either tank from exceeding max. design pressure of tank. ABS Inland Rules/46 CFR 177.10-1 LEGACY COMPONENT DESC: Storage Tanks
Condition: Improper Installation
Due 15 February 2005
Resolved 24 February 2005
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 April 2004 Resolved
Install vapor barrier over insulation on the aft engine room bulkhead to meet the requirements of 46 CFR 177.410(c)(4)
Condition: Improper/Lack of Maintenance
Due 8 April 2004
Resolved 8 April 2004
Operations/Management › Drills/Instruction › Fire
Issued 8 April 2004 Resolved
Write new engine room CO2 instructions that reflect the system installed, arrangement and operation requirements.
Condition: Placed in Improper Service
Due 8 April 2004
Resolved 8 April 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 April 2004 Resolved
Replace or repair the engine room CO2 system time delay bottle, so the discharge delay is atleast 30 seconds.
Condition: Unknown
Due 8 April 2004
Resolved 8 April 2004
Accommodation/Occupational Safety
Issued 15 August 2003 Resolved
Remove all hydraulic oil from all bilge spaces in the engine room prior to carrying passengers. LEGACY COMPONENT DESC: Hydraulic Oil in E/R Bilge
Due 15 August 2003
Resolved 22 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 15 August 2003 Resolved
Renew all oil soaked lagging in main engine room (upper and lower levels). LEGACY COMPONENT DESC: Oil Soaked Lagging
Due 22 August 2003
Resolved 22 August 2003
Pollution Prevention/Response › Prevention Equipment
Issued 15 August 2003 Resolved
Remove contaminated hydraulic oil from waste oil tank, & storage barrels onboard and discharge ashore. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Due 16 August 2003
Resolved 22 August 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 June 2003 Resolved
The vessel is to proceed from the port of Clarkston WA to the port of Longview, WA under stern tow, w/ pass. on board, per submitted/approved tow plan. Upon arrival to the port of Longview, WA the vessel will remain there until repairs are made to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 23 June 2003
Resolved 19 June 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 May 2003 Resolved
Make repairs to the vessels hydraulic system and notify the duty marine inspector by phone at [phone withheld] prior to departure. LEGACY COMPONENT DESC: Hydraulic Pump
Due 5 May 2003
Resolved 2 May 2003
Resolution: Inspected new hydraluic pump installation. Appears to be operating properly.
Fire Fighting › Structural Fire Protection - General
Issued 11 February 2003 Resolved
Replace missing steel window clips on the following windows: room 110 port, room 109 stbd, galley port, dining room stbd (5th window aft from midship door) & last dining room window stbd. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Unknown
Due 18 February 2003
Resolved 20 February 2003
Fire Fighting › Structural Fire Protection - General
Issued 11 February 2003 Resolved
Install closing devices for both fire screen doors leading to the engine control room. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Unknown
Due 18 February 2003
Resolved 20 February 2003
Electrical › Lighting (service)
Issued 11 February 2003 Resolved
Install covers on light fixtures where missing in the main engine room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 11 March 2003
Resolved 20 February 2003
Electrical › Electrical Distribution System (service)
Issued 11 February 2003 Resolved
Properly install defrost timer for main freezer in its junction box. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 11 March 2003
Resolved 10 March 2003
Resolution: Received written statement signed by master and chief engineer that the defrost timer was properly mounted in its junction box.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 February 2003 Resolved
Properly secure dryers in crew laundry space, and clean all lint/debris from behind dryers. LEGACY COMPONENT DESC: Laundry
Condition: Improper Installation
Due 11 March 2003
Resolved 10 March 2003
Resolution: Received a written statement from the master and chief engineer that the crew dryers were secured and the lint/debis cleaned from behind dryers.
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Install structural fire protection insulation to port aft corner overhead in C/E office to meet A-60. LEGACY COMPONENT DESC: Decks - Accommodation Spaces
Condition: Unknown
Due 18 February 2003
Resolved 20 February 2003
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Install blank in stuffing box leading from C/E office to corridors (A-60 boundry). LEGACY COMPONENT DESC: Bulkheads - Corridors
Condition: Improper Installation
Due 18 February 2003
Resolved 20 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 11 February 2003 Resolved
Clean and demonstrate proper operation of galley exhaust fire damper (stbd side). LEGACY COMPONENT DESC: Galley Exhaust
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2003
Resolved 20 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 11 February 2003 Resolved
Demonstrate the proper operation of all external fire dampers on the main deck. LEGACY COMPONENT DESC: Fire dampers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2003
Resolved 20 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 11 February 2003 Resolved
Repair and demonstrate proper operation of stbd engine room fire damper. LEGACY COMPONENT DESC: Main engine room fire damper
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2003
Resolved 20 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 11 February 2003 Resolved
Repair broken handrail support (crew stairway; lower forward rail). LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 11 March 2003
Resolved 20 February 2003
Operations/Management › Passenger Operations
Issued 11 February 2003 Resolved
Provide passenger safety bill instructions and place/post in all passenger staterooms. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 11 March 2003
Resolved 20 February 2003
Fire Fighting › Fire Hydrants
Issued 11 February 2003 Resolved
Remove all obstructions (permanently) from fire station #13 located in Columbia Showroom (port side). LEGACY COMPONENT DESC: Location/Position
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2003
Resolved 20 February 2003
Fire Fighting › Fixed Fire Detection System
Issued 11 February 2003 Resolved
Prove proper operation of lamp test switch for fire detection panel on bridge. LEGACY COMPONENT DESC: Control Panel
Condition: Unknown
Due 11 March 2003
Resolved 20 February 2003
Electrical › Electrical Distribution System (service)
Issued 11 February 2003 Resolved
Secure face plate on power distribution panel and label all circuits on bridge. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 11 March 2003
Resolved 10 March 2003
Resolution: Received written statement from master and chief engineer that the face plate on the power distribution panel on the bridge was installed and the circuits labeled.
Electrical › Lighting (emergency)
Issued 11 February 2003 Resolved
Prove proper operation of "E" lighting on stbd 300 deck (outside). LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 11 March 2003
Resolved 20 February 2003
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Install steel clips on inside of windows installed in A-0 bulkheads on all decks to prevent to windows from falling inward in the event of fire. (46 CFR 116.415) LEGACY COMPONENT DESC: Bulkheads - Accommodation Spaces
Condition: Improper Installation
Due 30 January 2004
Resolved 8 August 2003
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Install structural fire protection in the entire overhead of the #1 void (type 10 machinery space) adjacent to the Columbia Showroom (type 7 high risk accommodation space) to meet A-60. (46 CFR 116.415) LEGACY COMPONENT DESC: Decks - Machinery Spaces
Condition: Improper Installation
Due 30 January 2004
Resolved 8 April 2004
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Reduce fire load of the #2 void space to less than 0.5 pounds per sq foot, or insulate the overhead of the space to meet A-60. (46 CFR 116.415) LEGACY COMPONENT DESC: Decks - Aux Spaces (little/no fire risk)
Due 18 August 2003
Resolved 8 August 2003
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2003 Resolved
Install bulkhead and structural insulation meeting A-60 to separate the fixed fire extinguishing system bottles (type 1 space) from the garbage room, and galley space (type 9 spaces). (46 CFR 116.415) LEGACY COMPONENT DESC: Bulkheads - Control Stations
Condition: Improper Installation
Due 18 August 2003
Resolved 19 June 2003
Fire Fighting › Combustible Materials
Issued 11 February 2003 Resolved
Remove all combustible materials stowed in the stair tower leading to the crew areas and from the corridor adjacent to the [name withheld] office by fire stations #17 and #18. (46 CFR 116.405) LEGACY COMPONENT DESC: Furniture/Furnishings
Due 18 May 2003
Resolved 19 June 2003
Fire Fighting › Fixed Fire Detection System
Issued 11 February 2003 Resolved
Install fixed fire detecting systems in the following spaces; #1 void, C/E's office, entertainer's lounge, ship stores by laundry space, CO2 bottle room, garbage room, staterooms 109 & 111, weatherdeck store room, store room off main switch board room, & type 6 space off stair tower on Texas deck. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Due 30 January 2004
Resolved 8 April 2004
Engineering › Non-conventional Propulsion/Steering
Issued 20 March 2002 Resolved
Operationally test the hydraulic tank low level alarm on the primary steering system's sump to the satisfaction of the attending Coast Guard Marine Inspector. Until alarm is tested, hourly rounds are to be made to check the sump levels and the levels are to be reported to the bridge LEGACY COMPONENT DESC: Hydraulic fluid low level alarm
Condition: Improper Installation
Due 28 March 2002
Resolved 23 March 2002
Resolution: Operationally tested the low level hydraulic alarm by witnessing the alarm when the tank was drained. Alarm failed to operate initially because it had been disconnected during a recent yard period.
Engineering › Shafting/Propeller Arrangements
Issued 3 March 2002 Resolved
Water intrusion and possible scoring due to earlier incident during yard period when propulsion was engaged while shaft was secured. LEGACY COMPONENT DESC: Bearing
Condition: Damaged By Earlier Event
Due 3 March 2002
Resolved 3 March 2002
Engineering › Fuel Oil Service System
Issued 8 February 2002 Resolved
Install flame shield on generator RACOR filter bowls (46 CFR 119.100). LEGACY COMPONENT DESC: Filter
Condition: Unknown
Due 8 March 2002
Resolved 12 March 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 February 2002 Resolved
Install metal bracket to secured the expansion tank on the #2 ship's service generator.
Condition: Improper Installation
Due 8 March 2002
Resolved 12 March 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 February 2002 Resolved
Install flame protecting hose covers on generator fuel hoses to and from the fuel pump to meet S.A.E. J-1942 standards. LEGACY COMPONENT DESC: Fuel Hose
Condition: Improper Installation
Due 8 March 2002
Resolved 12 March 2002
Electrical › Electric Supply System (service)
Issued 8 February 2002 Resolved
Renew all zip-tie (plastic) clips on all overhead wire runs with metal clips (aux mach. space, engine room, generator room, and control booth.) [46 CFR 111.60-5] (IEE 45 - 10.5) LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 8 March 2002
Resolved 12 March 2002
Communications › Internal Communications System
Issued 8 February 2002 Resolved
Repair sound power phone circuit for the emergency steering station. Prove proper operation of all sound powered phones. LEGACY COMPONENT DESC: Sound-powered Telephone
Due 8 April 2002
Resolved 15 April 2002
Communications › Alarms/Indicators
Issued 8 February 2002 Resolved
Prove proper operation of the general alarm bell and light in the engine room. LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Due 8 March 2002
Resolved 11 February 2002
Fire Fighting › Structural - A Class Divisions
Issued 8 February 2002 Resolved
Install A-60 insulation on the backside of the bow thruster control panel in ship's stores locker. LEGACY COMPONENT DESC: Bulkheads - Control Stations
Due 8 March 2002
Resolved 11 February 2002
Fire Fighting › Structural - A Class Divisions
Issued 8 February 2002 Resolved
Restore A-0 bulkhead between gift shop store room and ship stores (lower level), due to two vent openings cut into bulkhead (install fuse-link vent dampers). LEGACY COMPONENT DESC: Bulkheads - Accommodation Spaces
Due 17 May 2002
Resolved 23 May 2002
Resolution: Vessel has installed a fuse-link vent damper at one location and welded an insert into the other.
Operations/Management › Passenger Operations
Issued 8 February 2002 Resolved
Provide service report/certificate for annual inspection of elevator. LEGACY COMPONENT DESC: Elevator Servicing Certificate
Due 8 March 2002
Resolved 12 March 2002
Fire Fighting › Structural - A Class Divisions
Issued 8 February 2002 Resolved
Provide proof of Coast Guard approval of the construction of the A-60 doors installed in way of galley. LEGACY COMPONENT DESC: Openings - Doors
Due 8 April 2002
Resolved 27 March 2002
Electrical › Lighting (emergency)
Issued 8 February 2002 Resolved
Provide emergency lighting in the engine room to illuminate the emergency escape hatch (stbd side).
Due 8 March 2002
Resolved 12 March 2002
Construction/Loadline
Issued 15 November 2001 Resolved
PROVE PROPER OPERATION OF BOTH FIRE DOORS BETWEEN THE GALLEY AND DINIING ROOM ABOARD THE VESSEL. BOTH DOORS SHALL CLOSE COMPLETELY AND LATCH WITH NO ASSISTANCE. THE DOORS SHALL SEAT PROPERLY IN THE DOOR FRAME WITH NO GAPS OR OPENINGS SHOWING. THIS MUST BE CORRECTED PRIOR TO 17NOV01.
Condition: Unknown
Due 17 November 2001
Resolved 19 November 2001
Engineering
Issued 18 February 2001 Resolved
MAKE PERM. REPAIRS TO THE VENT CLOSURES FOR THE ENGINEROOM (RESTORE TO ORIGINAL APPROVED ARRANGEMENT).
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Fire Fighting
Issued 18 February 2001 Resolved
HAVE FIXED CO2 SYSTEM REPAIRED AND SERVICED (POST FIRE)
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 18 February 2001 Resolved
RENEW ALL FIRE DAMAGED WIRING IN THE EXHAUST/CO2 SPACE. ALL WIRING TO BE REPLACED IN FULL LENGTH UNLESS OTHERWISE AUTH. BY CG MARINE INSPECTOR.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 18 February 2001 Resolved
REPAIR FIRE ALARM PULL STATION LOCATED IN THE ENGINE ROOM (DETACHED FROM THE J-BOX).
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Lifesaving
Issued 18 February 2001 Resolved
SUBMIT PROPOSAL TO [name withheld] CHANGES TO GARBAGE STOWAGE ARRANGEMENT ON BOARD THE VESSEL WHILE UNDERWAY.
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Engineering
Issued 18 February 2001 Resolved
RENEW EXHAUST FLANGE GASKET LOCATED IN THE EXHAUST/CO2 SPACE IN WAY OF THE UPPER INBOARD CORNER. HAVE VSL'S [name withheld] EXHAUSTPIPING IN THIS SPACE AND PROVIDE WRITTEN COND. FOUND REPORT FOR THE INPSECTOR.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Electrical
Issued 18 February 2001 Resolved
RENEW ALL DAMAGED LIGHTING FIXTURES IN THE EXHAUST/CO2 SPACE AND PORT SIDE E/R.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Engineering
Issued 18 February 2001 Resolved
REPAIR AND PROVE OPERATION OF PORT SIDE VENT DAMPER TO THE ENGINEROOM LOCATED IN THE EXHAUST/CO2 SPACE.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 12 February 2001 Resolved
Install smoke detection in #2 void.
Condition: Unknown
Due 1 February 2002
Resolved 8 February 2002
Resolution: Smoke detector was installed and test during vessels COI inspection.
Lifesaving
Issued 12 February 2001 Resolved
Hydrostatically test all air recievers and test safety relief valves in accordance with 46CFR176.812 and 46CFR61.10.
Condition: Unknown
Due 1 March 2001
Resolved 27 February 2001
Engineering
Issued 12 February 2001 Resolved
Install 30 x 30 mesh flame screen made of corrosion resistant material on all fuel tank vents IAW 46CFR182.20-35.
Condition: Unknown
Due 1 March 2001
Resolved 27 February 2001
Engineering
Issued 12 February 2001 Resolved
Provide a remote activating device to facilitate closing port side emergency fuel shut-off IAW 46CFR182.455.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 12 February 2001 Resolved
Install bilge alarm in #2 void IAW 46CFR182.530.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Fire Fighting
Issued 12 February 2001 Resolved
Provide fire servicing certificate.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Engineering
Issued 12 February 2001 Resolved
Repair port generator belt guard IAW 46CFR177.960.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Fire Fighting
Issued 12 February 2001 Resolved
Install vapor barrier over insulation in all machinery spaces having a common boundary with accomodation spaces IAW 46CFR177.405(e).
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Lifesaving
Issued 28 August 2000 Resolved
No passengers allowed in the Columbia Showroom within 12 feet of the brokenwindow and damaged area until the mast/boom is removed. 46 CFR 176.800
Condition: Unknown
Due 4 September 2000
Resolved 5 September 2000
Lifesaving
Issued 28 August 2000 Resolved
Provide 1 Pilot/Master and 2 qualified crew in the pilot house for transit to Longview, Washington. 46 CFR 176.800
Condition: Unknown
Due 4 September 2000
Resolved 5 September 2000
Lifesaving
Issued 28 August 2000 Resolved
No passengers allowed forward of the pilot house on outside decks until mast/boom is removed and all damaged handrail are replaced 46 CFR 176.800
Condition: Unknown
Due 4 September 2000
Resolved 5 September 2000
Engineering
Issued 9 December 1999 Resolved
Make repairs to port main engine, including exhaust manifold and turbo charger.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Fire Fighting
Issued 2 March 1999 Resolved
INSULATE OVERHEAD IN GENERATOR SPACE TO A-60, LAUNDRY SPACE BULKHEAD AT WATERTIGHT DOOR TO A-60 AND AT BULKHEAD BETWEEN NEW CREW QUARTERS AND EMERGENCY EQUIPMENT/STOREROOM ON TOP DECK TO A-60.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
INSTALL LARGER VENTILATION SYSTEM FOR CO2 STORAGE SPACE AND PROVIDE DOCUMENTARY EVIDENCE THAT TEMPERATURE REMAINS WITHIN LIMITS SPECIFIED IN 46CFR, DURING ALL PERIODS OF OPERATION.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
REMOVE PLASTIC TRASH RECEPTICLE FROM CREW LOUNGE AND PROVIDE METAL ENCLOSEDCONTAINERS IN ITS PLACE.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
REPAIR/REPLACE EMERGENCY POWER SOURCE FOR SMOKE DETECTING SYSTEM ON THE BRIDGE.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 2 March 1999 Resolved
INSTALL GUARDS AROUND BOTH MAIN PROPULSION DIESEL ENGINE DRIVE COUPLINGS.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
REMOVE ALL FLAMIBLE STORES FROM VOID NUMBER 2.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Electrical
Issued 2 March 1999 Resolved
REPAIR/REPLACE INVERTOR FOR EMERGENCY LIGHTING. INTERNAL FAN INOP CAUSING CONVERTER TO OVERHEAT. UPON REPAIR CONDUCT 2 HOUR TEST. PROVIDE 6 ADDITIONAL FLASHLIGHTS FOR LOWER DECK UNTIL INVERTER REPAIRED.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Electrical
Issued 2 March 1999 Resolved
INSTALL WATERTIGHT RECEPTICLES IN, VOID NUMBER 2 AT STAIRCASE, AT GRINDER IN VOID NUMBER 2, INSTALL WEATHERTIGHT UNDER SINK IN SHOWROOM AND AT SCULLERY COUNTER.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
REPAIR CONTROLS FOR FIRE SCREEN WINDOW FOR PURSORS OFFICE, AND DEMONSTRATE ELECTRICAL OPERATION.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Lifesaving
Issued 2 March 1999 Resolved
RENEW ALL NON-SKID THROUGH-OUT MACHINERY SPACE.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Electrical
Issued 2 March 1999 Resolved
REMOVE WIRE NUTS FROM WIRING UNDER BRIDGE CONSOLE AND THROUGH-OUT MACHINERYSPACE AND INSTALL PRESSURE CONNECTORS.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Electrical
Issued 2 March 1999 Resolved
HARDWIRE CREW WASHER AND DRYERS OR INSTALL WATERTIGHT RECEPTICLES AND PLUGSFOR SAME.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
PREFORM CONDUCTIVITY TEST ON CO2 HOSE ASSEMBLY FOR PORTABLE EXTINGUISHER.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Electrical
Issued 2 March 1999 Resolved
DEMONSTRATE THAT EMERGENCY BATTERIES WILL LAST 2 HOURS PER INSPECTION NOTE ENTERED 4JUL95, REF. CASE MI94042772.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
CLEAN ALL LINT FROM BEHIND DRYERS FOR PASSENGERS AND CREW, TO INCLUDE WIRING AND MOTORS IN DRYER CABINETS, REINSTALL COVERS AND DRYER HOSE ON PASSENGERS DRYERS.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
INSULATE HOT WATER PIPING WHERE EXPOSED IN VOID NUMBER 2.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Construction/Loadline
Issued 22 October 1998 Resolved
ADJUST AND CONDUCT CHALK TEST ON PORT SIDE MAIN DECK WATERTIGHT DOOR TO VOID NUMBER TWO.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Navigation
Issued 22 October 1998 Resolved
REPAIR/REPLACE SOUND POWERED PHONE FOR EMERGENCY STEERING STATION IN AFT MACHINERY SPACE. USE OF HAND PHONE SAT AS TEMPORARY REPAIR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998 Resolved
REMOVE ALL FLAMABLES FROM VOID NUMBER 2 AND STOW IN ACCEPTABLE LOCATION.
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Accommodation/Occupational Safety
Issued 22 October 1998 Resolved
REPAIR GRAY WATER DRAIN LINE STARBOARD SIDE IN BILGE/FIRE PUMP SPACE.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 22 October 1998 Resolved
INSTALL GUARD AROUND STARBOARD GENERATOR BELTS.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 17 April 1998 Resolved
PROVE PROPER OPERATION OF SHIPS SERVICE GENERATORS. GENERATORS CANNOT BE OPERATED IN PARALLEL UNTIL REVERSE PWR RELAY CAN BE PROVEN TO FUNCTION CORRECTLY. ENGINEERS ARE TO MAINTAIN A DILIGENT WATCH UNTIL SUCH TIME AS GENERATOR REVERSE PWR FUNCTION CAN BE PROVEN.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Engineering
Issued 13 March 1998 Resolved
LIMIT OPERATING PRESSURE ON THE HYDRAULIC SYSTEM TO 2600 PSI UNTIL THE CROSS OVER RELIEFS ON THE STARBOARD BLOCKS AT THE MOTOR ARE REPLACED WITH FACTORY SET RELIEFS.
Condition: Unknown
Due 3 April 1998
Resolved 6 April 1998
Electrical
Issued 13 March 1998 Resolved
PROPERLY INSTALL STRIP TRACK LIGHTING ON EXTERIOR OF VESSEL.
Condition: Unknown
Due 3 April 1998
Resolved 6 April 1998
Electrical
Issued 13 March 1998 Resolved
PROVE THE INSTALLED ELECTRIC HEATERS ON THE FOURTH DECK ARE SUITABLE FOR MARINE USE. (46 CFR 184.200)
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Engineering
Issued 13 March 1998 Resolved
PROVIDE TWO ADDITONAL SETS OF DRAWING NUMBER D-165951 FOR APPROVAL.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Engineering
Issued 13 March 1998 Resolved
DURING THE MARCH98 SHIPYARD PERIOD, MODIFICATIONS WERE MADE TO THE PIPING SYSTEM PREVIOUSLY APPROVED UNDER DRAWING NUMBER 5418-5 DATED 2/15/96. RESUBMIT A REVISION TO THE ABOVE DRAWING INDICATING THE MODIFICATIONS AND ALIST OF MATERIALS USED FOR APPROVAL. SUBMIT 3 SETS OF DRAWINGS.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Engineering
Issued 13 March 1998 Resolved
PROPERLY REPAIR FACE MATING PLATE ON THE STARBOARD MOTOR GEAR BOX TO PREVENT GEAR OIL LEAK.
Condition: Unknown
Due 3 April 1998
Resolved 6 April 1998
Engineering
Issued 13 March 1998 Resolved
DURING THE MARCH98 SHIPYARD PERIOD, MODIFICATIONS WERE MADE TO THE PIPING SYSTEM PREVIOUSLY APPROVED UNDER DRAWING NUMBER 5418-1 DATED 2/15/96. RESUBMIT A REVISION OF THE ABOVE DRAWING INDICATING THE MODIFICATIONS AND ALIST OF MATERIALS USED FOR APPROVAL. SUBMIT 3 SETS OF DRAWINGS.
Condition: Unknown
Due 13 May 1998
Resolved 6 July 1998
Electrical
Issued 13 March 1998 Resolved
PROPERLY INSTALL THE HEATER UNITS ON THE FOURTH DECK IAW 46 CFR 184.200. THE HEATER UNITS MUST BE PERMANENTLY INSTALLED.
Condition: Unknown
Due 3 April 1998
Resolved 6 April 1998
Fire Fighting
Issued 15 March 1997 Resolved
REPLACE AS ORIGINAL, ALL INSULATION ON BULKHEAD BETWEEN PILOT HOUSE VOID AND BATTERY LOCKERS._x001C_ _x001C_ X
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 15 March 1997 Resolved
PROPERLY INSTALL FAN IN PORT PILOTHOUSE VOID. ALL EXPOSED WIRES TO BE SAFE-ENDED UNTIL COMPLETED.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 March 1997 Resolved
PROVE PROPER OPERATION OF FIRE DOOR PRE-CLOSURE ALARM IN PURSER'S OFFICE.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 15 March 1997 Resolved
PROPERLY SUPPORT ALL CABLE RUNS, INCLUDING, BUT NOT LIMITED TO, PILOTHOUSE VOID, PILOTHOUSE CONTROL STATION SPACE, GENERATOR SPACE, MAIN ENGINE SPACE,E-LOCKER, AND ENGINE ROOM CONTROL SPACE.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 15 March 1997 Resolved
CLEAN ALL HYDRAULIC FLUID AND ANTI-FREEZE FROM ENGINEROOM DECK/BILGES. RENEW NON-SKID IN ALL ACCESSIBLE AREAS.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 15 March 1997 Resolved
PROVE SATISFACTORY PARALLEL OPERATION OF SHIP SERVICE GENERATORS.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 15 March 1997 Resolved
PROVE PROPER OPERATION OF SSG REVERSE POWER RELAYS.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Engineering
Issued 15 March 1997 Resolved
REPLACE OR PROVE ACCEPTABLE, FLEXIBLE FUEL HOSES ON SHIP'S SERVICE GENERATORS.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Accommodation/Occupational Safety
Issued 15 March 1997 Resolved
PROPERLY LABEL ESCAPE HATCH IN CO2 ROOM
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 March 1997 Resolved
INSTALL ACCEPTABLE FIRE STOPS IN CABLE PENETRATIONS BETWEEN GALLEY SPACE AND ENGINE CONTROL SPACE.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 March 1997 Resolved
INSTALL ACCEPTABLE FIRE STOPS IN DECK CABLE PENETRATIONS BETWEEN PILOT HOUSE AND PILOT HOUSE VOID._x001C_
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 February 1997 Resolved
CROP AND RENEW FLANGE PLATE ON UNDER DECK BRACKET, #7 STARBOARD SIDE, MAIN DECK.
Condition: Unknown
Due 15 March 1997
Resolved 15 March 1997
Unknown
Issued 21 February 1997 Resolved
PROVIDE PLANS FOR REPAIRS TO ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL DAMAGE FROM FIRE IN PILOT HOUSE VOID.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Construction/Loadline
Issued 21 February 1997 Resolved
REPAIR BROKEN WELDS ON PORTSIDE VERTICAL STIFFENERS ON THE AFT POTABLE WATER TANK IN THE #1 VOID.
Condition: Unknown
Due 15 March 1997
Resolved 15 March 1997
Documentation
Issued 27 September 1996 Resolved
AFTER COMPLETION OF ALL WEIGHT CHANGES TO THE VESSEL, SUBMIT DOCUMENTATION TO SATISFY THE REQUIREMENTS OUTLINED IN MSC-1 LETTER DATED APRIL 1, 1996.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Navigation
Issued 7 September 1996 Resolved
Replace the steering system follow up transmitter and prove proper operation of the steering system to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 7 September 1996
Resolved 7 September 1996
Navigation
Issued 7 September 1996 Resolved
Move out of the weather, or provide suitable waterproof enclosure for, the steering system follow up transmitter now located on the port, aft paddlewheel platform to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 7 September 1996
Resolved 7 September 1996
Navigation
Issued 7 September 1996 Resolved
Post ledgible, easily understood emergency/alternate steering system procedures in a conspicuous location in the pilot house to the satisfactionof the cognizant OCMI.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Construction/Loadline
Issued 7 September 1996 Resolved
Make permanent repairs to the weld fracture in the stbd aft paddlewheel platform to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 7 September 1996
Resolved 7 September 1996
Navigation
Issued 7 September 1996 Resolved
Repair or replace the inoperable center, port and stbd bridge control station RPM indicators to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 7 September 1996
Resolved 7 September 1996
Accommodation/Occupational Safety
Issued 7 September 1996 Resolved
Make permanent repairs to the fractured hand rail on the stbd aft paddlewheel platform to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 7 September 1996
Resolved 7 September 1996
Engineering
Issued 3 July 1996 Resolved
HAVE NAVAL ARCHITECT SUBMIT PLANS TO THIS INSPECTION OFF DETAILING PROPOSEDPERMANENT REPAIRS TO CORRECT REOCCURRING CRACKS IN PROPULSION WHEEL HUB. UPON APPROVAL OF THESE PLANS, COMPLETE PERMANENT REPAIRS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Engineering
Issued 12 April 1996 Resolved
MAKE PEMANENT REPAIRS TO SHAFT PLATE WHERE ATTACHED TO PADDLEWHEEL ON THE STARBOARD SIDE. CONDUCT NON-DESTRUCTIVE TESTING TO WELDS ON PLATE ATTACHMENT ON THE PORT SIDE. CONDUCT SEA TRIALS AFTER ALL REPAIRS COMPLETE AND SUBMIT WRITTEN CERTIFICATION AS TO CONDITIONS OF REPAIRS AND SEA TRIAL.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 14 March 1996 Resolved
Replace bolts in split flange couplings with a grade 8 bolt of the correct lengths and sizes, as indicated in SAE J518. Until bolts are replaced the master is to insure that a bi-weekly check of the torque on these bolts is conducted and logged.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Lifesaving
Issued 14 March 1996 Resolved
Steam clean engine room to remove all oil residue created from blown seals from split flange couplings.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996 Resolved
Install chaffing gear on flexhose and piping in the hydraulic system where making contact throughout the entire system.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996 Resolved
Make adjustments to the Sinclear Logic Panel to eliminate loss of pilot house control on reset of alarm. A caution sign is to be installed to prevent reset of alarm until repairs are made.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Navigation
Issued 14 March 1996 Resolved
Make adjustments and fine tune the controls for the main steering gear in the pilot house.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 14 March 1996 Resolved
Make adjustments to the pilot house control system to allow control of engine RPM when adjusting paddlewheel speed. Until adjustments are made theengine control station is to be manned during manuvering evolutions. ie: entry into locks and in and out of port.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Engineering
Issued 14 March 1996 Resolved
Install audible alarm to indicate loss of prt and stbd gear oil pumps or toindicate a non-start of these pumps upon main engine start.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 14 March 1996 Resolved
Prove adequacy of ventilation for CO2 storage space to insure space temp does not exceed 130 degrees. Relocate natural vent for space outside of thegalley.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Fire Fighting
Issued 14 March 1996 Resolved
Install the locking mechanism on the port fire screen door from the galley into the dining hall.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Accommodation/Occupational Safety
Issued 14 March 1996 Resolved
Repair/replace and demonstrate operation of the general alarm bell in the Paddlewheel Lounge.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Engineering
Issued 14 March 1996 Resolved
Repair/replace fitting to case drain on the stbd fwd hydraulic pump where leaking.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Electrical
Issued 14 March 1996 Resolved
Prove proper operation of port and starboard overspeeds for the ship service generators.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Engineering
Issued 14 March 1996 Resolved
Replace with proper grade material or test to the satisfaction of CG MSC, the 4 Cross Port Relief Valves.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Accommodation/Occupational Safety
Issued 25 August 1995 Resolved
The Paddle Wheel Lounge and the Dining Hall are restricted to passengers during high noise levels. These areas may be utilized with adaquate hearing protection and at reduced vessel speeds when noise level is lower.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Electrical
Issued 25 August 1995 Resolved
Provide operational data to show that the main power generating system is capable of handling the ship service loads. Either by properly load shedding or automatic parrallel of generators during high load demands.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Accommodation/Occupational Safety
Issued 25 August 1995 Resolved
Conduct a noise survey of the following areas and install insulation as determined by the survey: 1) Paddle Wheel Lounge, 2) Dinning Area 3) Galleyand 4) Crews Quarters.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Accommodation/Occupational Safety
Issued 25 August 1995 Resolved
Ensure door to galley from the dining hall on the starboard side close properly.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 25 August 1995 Resolved
Demonstrate that electronics for the starboard propulsion engine operates properly after installation of new electronics control unit.
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Documentation
Issued 17 August 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 17 August 1995 Resolved
TEST AND LABEL GENERAL ALARM LIGHTS OR BELLS IN THE FOLLOWING LOCATIONS: LOWER ENGINE ROOM SPACE, #1 VOID, #2 VOID.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 17 August 1995 Resolved
PROVIDE AND POST STATION BILL IN ACCORDANCE WITH NVIC 11-83 AND 46 CFR 78.13 STATION BILL SHALL BE POSTED IN GALLEY, CREWS QUARTERS, EMERGENCY GEAR LOCKER, AND BRIDGE.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 17 August 1995 Resolved
CONTINUE TO LABEL VESSEL'S SYSTEMS AS PREVIOUSLY MARKED IN MASKING TAPE, IEGENERAL ALARM BELLS & LIGHTS, CREW ONLY SIGNS, VENT CLOSURES ......
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 17 August 1995 Resolved
CONDUCT UNDERWAY TRIALS OF PROPULSION SYSTEM: FULL AHEAD, CRUISING SPEED, AND EMERGENCY STOP.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995
Accommodation/Occupational Safety
Issued 17 August 1995 Resolved
ALL DECKING MATERIAL IN THE LAUNDRY AND SWITCHBOARD ROOM SHALL BE CONSTRUCTED IN ACCORDANCE WITH 46 CFR 72.05-10(c) AND 46 CFR 72.05-15(f).
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 17 August 1995 Resolved
IN ACCORDANCE WITH ASME A17.1 PART XXII RULE 2201.2 MEANS SHALL BE PROVIDEDWITHIN THE ELEVATOR CAR TO GAIN ACCESS TO THE TOP EMERGENCY EXIT.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 17 August 1995 Resolved
RESUBMIT PLANS FOR APPROVAL ON HYDRAULIC PROPULSION SYSTEM.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995
Fire Fighting
Issued 17 August 1995 Resolved
ADJUST PORT AND STBD FIRE SCREEN DOORS FOR GALLEY SO THAT DOOR CLOSES FIRMLY AGAINST THE DOOR FRAME. DOOR MUST CLOSE AGAINST THE FRAME SO MAGNETIC RELEASE FOR STRIKER CAN PROPERLY LATCH THE DOOR.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Construction/Loadline
Issued 17 August 1995 Resolved
PROVIDE FIXED BALLAST PLAN AND STRESS CALCULATIONS FOR FIXED CONCRETE BALLAST.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Electrical
Issued 17 August 1995 Resolved
PROPERLY INSTALL BATTERY LOCATED IN THE STAIRTOWER, WHICH IS USED FOR THE PUBLIC PHONE, IN ACCORDANCE WITH 46 CFR 111.15
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Navigation
Issued 17 August 1995 Resolved
CONDUCT STEERING TEST OF MAIN ELECTRIC, EMERGENCY ELECTRIC, AND MANUAL EMERGENCY SYSTEMS.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995
Electrical
Issued 17 August 1995 Resolved
PROVE PROPER OPERATION OF THE SHIP'S SERVICE GENERATOR AND SWITCHBOARD TO THE SATISFACTION OF MSO PORTLAND.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995
Fire Fighting
Issued 17 August 1995 Resolved
CONDUCT FIRE, RESCUE, AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Documentation
Issued 17 August 1995 Resolved
PROVIDE DRUG TESTING POLICY AND LAB RESULTS OF CURRENTLY EMPLOYED CREW MEMBERS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995

Casualty record · 15

16 August 2005Routine · role: Involved in a Marine Casualty · activity 2464902
22 August 2006Routine · role: Involved in a Marine Casualty · activity 2763327
18 September 2006Routine · role: Involved in a Marine Casualty · activity 2782413
10 April 2007Routine · role: Involved in a Marine Casualty · activity 2906158
13 October 2007Routine · role: Involved in a Marine Casualty · activity 3195782
8 April 2008Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3179829
18 August 2008Routine · role: Involved in a Marine Casualty · at MCNARY DAM LOCKS BRIDGE · activity 3304826
12 September 2008Routine · role: Involved in a Marine Casualty · activity 3326356
7 August 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4405289
29 June 2014Routine · role: Involved in a Marine Casualty · 2 injured · activity 4951551
25 September 2015Routine · role: Involved in a Marine Casualty · activity 5728867
24 September 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6549289
26 August 2024Routine · role: Involved in a Marine Casualty · activity 8027825
2 August 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · at MCNARY DAM LOCKS BRIDGE · activity 8201393
29 September 2025Routine · role: Involved in a Marine Casualty · activity 8244207
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

QUEEN OF THE WEST (2005–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.