Records from 1994 to 2023. Most recent: inspection, 21 December 2023.
Inspection history · 201
21 December 2023
Special Consideration · Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7841543
26 February 2009
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3424476
19 November 2008
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3365863
5 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3321090
25 August 2008
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3340794
2 June 2008
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3340799
11 February 2008
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3340790
19 November 2007
Hull Examination · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3100810
9 May 2007
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2930410
7 February 2007
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2868686
16 October 2006
Deadweight Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2801314
15 August 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2875992
17 May 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2657564
25 February 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2591783
21 November 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2538224
23 February 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2298463
15 December 2004
Deadweight Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2272145
9 November 2004
Underwater Inspection in lieu of Drydock · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2238101
24 August 2004
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2180105
24 May 2004
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2100342
17 February 2004
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2011421
19 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1967218
19 November 2003
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1951037
17 November 2003
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1949225
19 August 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1880227
15 May 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1794426
18 February 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1745764
26 December 2002
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1723013
19 November 2002
COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1715124
30 September 2002
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1716052
30 August 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1668710
30 August 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1710133
22 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1619652
26 March 2002
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1597712
26 February 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1489245
24 February 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1488816
18 February 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1487432
4 February 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1483719
10 December 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8538
27 November 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425244
18 September 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073352
5 June 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1066808
20 February 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384679
7 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 82891
8 September 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053974
5 September 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1055004
7 June 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1051465
12 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048620
4 April 2000
Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047150
6 March 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817958
12 January 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817391
30 November 1999
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438949
15 November 1999
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047521
15 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456783
17 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 213606
15 September 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444221
18 August 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 778955
21 July 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1103207
29 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446795
14 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 789312
24 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777557
24 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 787272
15 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463438
21 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 130729
19 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58636
2 December 1998
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449130
22 September 1998
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1368878
29 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 17543
28 July 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 75775
28 July 1998
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1130436
17 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 45318
23 June 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400801
16 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469504
30 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70028
30 March 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411641
19 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 131453
2 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411577
29 December 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1120756
10 December 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 13112
2 December 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443938
20 October 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 776763
19 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105747
16 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 181390
9 October 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1378178
10 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 92173
6 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 39436
24 August 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 36035
17 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36830
25 July 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 118353
25 July 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 178837
25 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 188896
20 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 149597
18 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14180
24 June 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407913
1 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163124
25 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101156
4 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 42307
26 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 45918
25 April 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101500
14 April 1997
Deficiency Check · Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096338
6 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127019
27 March 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409656
22 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152620
8 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70297
25 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101684
21 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 27237
3 December 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359304
21 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 142603
23 October 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850636
23 September 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418021
1 September 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943609
28 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40464
19 August 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438477
12 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 143839
12 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 181949
6 August 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1088280
23 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 178159
23 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1085661
19 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136431
11 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117505
4 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 4801
28 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 149782
25 June 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422707
21 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79445
1 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53024
29 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 155004
4 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 103298
31 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 18053
31 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108378
26 March 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434368
22 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 104114
9 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 43297
9 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 63588
5 March 1996
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442363
2 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 22488
22 February 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193139
10 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 173210
2 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50418
29 December 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419536
13 December 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360337
4 December 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360327
1 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 74479
24 November 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404044
20 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151413
14 November 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874190
8 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 876722
25 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 32384
20 October 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385553
10 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 126623
9 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 175003
28 September 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358922
26 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84212
26 September 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880965
20 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179552
15 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113875
5 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151984
28 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 175300
28 August 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411159
20 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 26102
11 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 71380
1 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58941
12 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 879450
3 July 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442278
30 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 3883
28 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 56039
28 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 184077
26 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 12151
20 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878986
15 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9622
14 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414480
10 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 143712
10 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 148821
9 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108596
30 May 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 752050
20 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100428
15 May 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228561
3 May 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1180164
1 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58242
26 April 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 860723
22 April 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 205127
12 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355199
11 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 4985
7 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 17292
7 April 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 841784
7 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380179
3 April 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146711
28 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141419
27 March 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394301
23 March 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139143
13 March 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 710220
8 March 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 858608
3 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102716
2 March 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164825
23 February 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1159227
17 February 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865077
16 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40476
7 February 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146663
10 January 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 222217
6 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 863166
5 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430003
23 December 1994
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439582
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 9 September 2008
Resolved
Provide local USCG OCMI with proposal for a mooring configuration that will withstand 150 MPH winds in hurricane conditions. A professional engineering assessment will be requried. LWB
Action required: 705 - Other - as specified
Due 6 October 2008
Resolved 28 October 2008
Resolution: A mooring configuration was provided that would allow subject vsl mooring to withstand 150 MPH winds.
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 14 May 2007
Resolved
Number one main low lube oil shutdown and emergency stop failed to work.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 4 June 2007
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 14 May 2007
Resolved
Paddle wheel engine's #2, #4, and #6 vavlves and pistons need reworking due to poor performance.
Action required: 705 - Other - as specified
Due 8 June 2007
Resolved 4 June 2007
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2007
Resolved
All weather decks are in need of repair. Prepare a repair proposal for repairing wasted exterior area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 4 June 2007
Resolution: Crew is working to stripe and repaint all outside decks.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 24 February 2006
No resolution recorded
No passenger will be authorized onboard the vsl when the vsl joes on ships power. Determine what occured during parallel testing of the generators, correct and submit report.
Condition: Unknown
Action required: 705 - Other - as specified
Resolution: Tech out to repair.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 24 February 2006
No resolution recorded
Required sceduled maintenance needs to be completed on all eng/gen. Crank case needs to be corrected. Mechanical and carbon monoxide issue. All eng/gen need to be reviewed with tech rep and repaired IAW manufactored requirements.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 February 2006 — due date passed with no resolution recorded
Resolution: Completed repairs to eng/gen set.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 February 2006
No resolution recorded
Draw up and submit alternate evacuation plan until employee ramp is back up.
Due 25 February 2006 — due date passed with no resolution recorded
Resolution: All rams have been rebuilt and installed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2006
No resolution recorded
Texas deck - AEVADS system needs to be louder to be heard by passengers. Increase volume to be heard over ventilation system.
Condition: Unknown
Due 27 May 2006 — due date passed with no resolution recorded
Resolution: Speakers turned up.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 February 2006
No resolution recorded
Repair/replace burnt outlet locatred in "Z" drive room.
Condition: Unknown
Due 3 March 2006 — due date passed with no resolution recorded
Resolution: Outlet replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2006
No resolution recorded
Thermostate wire is loose on the #4 AHV.
Condition: Unknown
Due 3 March 2006 — due date passed with no resolution recorded
Resolution: Wire tightened.
Stability › Intact Righting Energy › General
Issued 24 February 2006
No resolution recorded
Storage units on Hurrican Deck needs to be removed or fire calculations and weight for stability need to be submitted to MSC. Additionally need to be IAAW with VSP.
Due 3 March 2006 — due date passed with no resolution recorded
Resolution: Calculations conducted and submitted to MSC.
Stability › Intact Righting Energy › General
Issued 24 February 2006
No resolution recorded
Void space under wheelhouse - determine what plans have space designated as. If space needs to be changed - submit new plans and letters to MSC to change space designation.
Action required: 705 - Other - as specified
Due 24 March 2006 — due date passed with no resolution recorded
Resolution: Space will be confined space.
Fire Fighting › Fire Hoses › Condition
Issued 21 November 2005
Resolved
Establish procedures for testing fire hoses and provide to USCG.
Condition: Unknown
Due 23 November 2005
Resolved 23 November 2005
Resolution: Procedures establishe for testing fire hoses.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 21 November 2005
Resolved
Repair overspeed, low oil shutdown, and water jacket temp for the number (1) one generator.
Condition: Unknown
Due 28 November 2005
Resolved 25 November 2005
Resolution: Repaired overspeed, low oil shutdown, and water jacket temp for the number (1) one generator.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 21 November 2005
Resolved
Replace/repair accept button on alarm panel located in control room.
Condition: Unknown
Due 28 November 2005
Resolved 28 November 2005
Resolution: Repaired accept button on alarm panel located in control room.
Communications › Audible Communications › SPD (Other)
Issued 23 February 2005
Resolved
Replace/repair loud speakers on top deck (4 )- 2 p/s / 2 fore/aft.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 March 2005
Resolution: New speakers installed.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 23 February 2005
Resolved
Place locks on all rest room cabinets per MTSA security measures.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 March 2005
Resolution: Locks installed.
Construction/Loadline › Structures › Door
Issued 23 February 2005
Resolved
Repair port aft fire door to propulsion hydraulic motor room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 March 2005
Resolution: Door repaired.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 November 2004
Resolved
Fire Control Plan needs to be corrected. FCP does not indicate the number of items and locations. Make corrections, conduct walk through and post.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 3 December 2004
Resolution: fire control plan has been corrected. Vsl walked through and found some problems. Sent back for additional revisions. Should have final next week. Will double check on next quarterly.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 9 November 2004
Resolved
Emergency Procedures need to be expanded to include: launch/recovery of rescue boat; launch of emergency anchor; expand AEVADS checklist to include WTD; procedures to start fire pump; expand checklist for collision, man over board and checklist for fire on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Resolution: Emergency Procedures have been undated.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 24 August 2004
Resolved
Vsl has excessive power stripes throughout all spaces. Vsl is working on an electrical installation and maintenance plan. Will need to be reviewed upon completion.
Action required: 705 - Other - as specified
Due 7 September 2004
Resolved 2 September 2004
Resolution: Corrected all items. Removed power stripes.
Stability › Incline Test › General
Issued 24 August 2004
Resolved
Main deck stairwell as unapproved storage area: remove from vsl, basket lift. If vsl wishes to store basket lift in location, submit to MSC for stability calculations and approval from local OCMI.
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 24 August 2004
Resolution: Lift basket removed. Never used but purchased for atrium maintenance.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 August 2004
Resolved
Fire control plan needs to have additional information added. They did not have numbers/counts of items per deck. Need to update and have ready for next inspection.
Action required: 705 - Other - as specified
Due 7 October 2004
Resolved 7 October 2004
Resolution: Vsl stated that new FCP has been completed and waiting for next inspection.
Fire Fighting › Fire Main › Valves
Issued 24 August 2004
Resolved
Main deck drain and 24 hr sprinkler system service pipes are missing end caps. Install caps on water lines. Ensure that valves are closed to ensure water line stays operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 1 September 2004
Resolution: Placed caps on all pipes.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 August 2004
Resolved
Vessel has been conducting MTSA drills, however, they are not logging it properly. Drills are located in three different logs and none match up on dates and description of drill. Vsl told to revise log books and track employee training better.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 2 September 2004
Resolution: Vessel has revised training logs to track better.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 24 May 2004
Resolved
HVAC room - remove plastic water bottle that is being used as pipe from unit to drain. Fix with proper piping.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Installed drain line.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 May 2004
Resolved
Power stripe has ends removed. Open to allow for objects to be inserted. Remove and do not fabricate in house power stripe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Removed stripe.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 May 2004
Resolved
Dispatch office - open/dead end wires located from outlet box, need proper cover installed. Upper cash cage has open outlet box, needs cover, and remove power stripe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Completed.
Construction/Loadline › Penetrations
Issued 24 May 2004
Resolved
Liquar locker - 2 thru hull penetrations need to be capped.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Capped off pipes.
Construction/Loadline › Penetrations
Issued 24 May 2004
Resolved
Elevator Equipment room - cap off pipes. Valves closed but pipes need to be capped off.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Capped off pipe.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 May 2004
Resolved
Slot room- ceiling tile broken and has not been replaced. Pipe located in ceiling need to be checked for cap and repaired in 2 locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Repaired and ceiling tile replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 May 2004
Resolved
Smoke detector was installed incorrectly and light to indicate alarm was missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 31 May 2004
Resolution: Smoke detector was corrected.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 February 2004
Resolved
Vessel needs to ensure that venting system and AEVAD system are turned on and working IAW with system and COI. Vessel had then turned off, thought it was inconvienent to always check the alarms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 17 February 2004
Resolution: Vessel will always have venting and AEVAD systems on.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 February 2004
Resolved
Unclip and restow all PFD's.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 February 2004
Resolved 24 February 2004
Resolution: Vessel unclipped all PFD''s and restowed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 February 2004
Resolved
Remove extension cords ran to fans located in all restrooms, ensure that fans are cleaned of all dust, dirt and spider webs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2004
Resolved 24 February 2004
Resolution: Installed additional plug-in boxes and removed extension cord for fans.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 February 2004
Resolved
Camera located in beverage room was only installed with wire nuts. Need to complete installation of camera and wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2004
Resolved 24 February 2004
Resolution: Installation of camera and wiring completed.
Electrical › Electric Supply System (service)
Issued 17 November 2003
Resolved
Insure power strips are properly installed and of proper grade in Surveillance Room. LEGACY COMPONENT DESC: Power Strip
Condition: Improper Installation
Due 18 December 2003
Resolved 15 December 2003
Resolution: Removed all.
Electrical › Electrical Distribution System (service)
Issued 17 November 2003
Resolved
Insure power strips are installed properly and of proper grade in Soft Count Room. LEGACY COMPONENT DESC: Power strip
Due 24 November 2003
Resolved 15 December 2003
Resolution: Removed all.
Electrical › Electrical Distribution System (emergency)
Issued 17 November 2003
Resolved
Improperly stored equipment in switchboard, Remove all gear store in switchboard panels
Due 18 November 2003
Resolved 15 December 2003
Resolution: Removed all.
Electrical › Electrical Distribution System (service)
Issued 17 November 2003
Resolved
Remove unused junction box and dead end wire above sprinkler pressure tank. LEGACY COMPONENT DESC: Junction Box
Condition: Damaged By Earlier Event
Due 18 December 2003
Resolved 15 December 2003
Resolution: Removed dead end wires and junction box.
Fire Fighting › Structural - Main Vertical Zones
Issued 17 November 2003
Resolved
Need to install proper automatic door releases. Repair all unused penetrations. LEGACY COMPONENT DESC: Automatic door closures
Condition: Improper Installation
Due 24 November 2003
Resolved 15 December 2003
Resolution: Replaced inoperative door release. Tested sat.
Engineering › Diesel Engine (propulsion-electric)
Issued 17 November 2003
Resolved
# 1 SSDG L/O leak on outboard side. Repair. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Due 24 November 2003
Resolved 15 December 2003
Resolution: Repaired leak.
Engineering › Bilge Water Management System
Issued 17 November 2003
Resolved
Determine cause of high bilge alarm in Soft and Hard Count bilges. Correct. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 24 November 2003
Resolved 18 November 2003
Resolution: Removed water from bilge.
Engineering
Issued 17 November 2003
Resolved
Install proper metal wire restraint in public and service elevator shafts, and remove all gear from shafts. Repair and Correct LEGACY COMPONENT DESC: Elevator shaft
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 15 December 2003
Resolution: Install tie wraps. Cleaned area under elevator.
Engineering
Issued 17 November 2003
Resolved
Hydraulic lift cylinders of both service and public elevators have leaking seals. Repair/Adjust LEGACY COMPONENT DESC: Elevator Hydraulics
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 15 December 2003
Resolution: Parts are ordered and installed.
Engineering › Diesel Engine (auxiliary)
Issued 17 November 2003
Resolved
Leak on Racor of Emergency Generator fuel filter. Repair LEGACY COMPONENT DESC: Emergency Generator
Condition: Improper/Lack of Maintenance
Due 24 November 2003
Resolved 15 December 2003
Resolution: Replace fuel bowl and o-ring.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 November 2003
Resolved
Accumulation of hydraulic oil under storage tank in aft crew breaks area. Repair/ Clean
Due 24 November 2003
Resolved 15 December 2003
Resolution: Clean and tightened flange.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 November 2003
Resolved
Accumulation of hydraulic oil under port Z-Drive. Repair/Clean
Due 24 November 2003
Resolved 15 December 2003
Resolution: Replaced filter, this corrected problem.
Engineering
Issued 17 November 2003
Resolved
Missing dogging bar on aft hatch to Z-Drive room. Replace/Adjust LEGACY COMPONENT DESC: Water Tight Hatch
Due 1 December 2003
Resolved 15 December 2003
Resolution: Replaced missing dogging bar, Sat chalk test.
Engineering
Issued 17 November 2003
Resolved
Tank of refrigerant in A/C flat loose. Properly secure and store
Condition: Improper/Lack of Maintenance
Due 18 November 2003
Resolved 15 December 2003
Resolution: Secured with cargo strap.
Electrical › Electric Generation Source (service)
Issued 17 November 2003
Resolved
Reverse power relay, Show proper operation. Adjust /Test LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 15 December 2003
Resolved 15 December 2003
Resolution: Show proper operation of both reverse power relay.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 November 2003
Resolved
Show proper operation of over speed trip #1SSDG, #2SSDG and #1 MDE. Adjust/Test
Condition: Improper/Lack of Maintenance
Due 24 November 2003
Resolved 15 December 2003
Resolution: Vessel showed proper operation of above.
Engineering › Diesel Engine (propulsion-electric)
Issued 17 November 2003
Resolved
Show proper operation of starting system of #2 SSDG. Inspect/Test
Condition: Improper/Lack of Maintenance
Due 24 November 2003
Resolved 15 December 2003
Resolution: Replaced battery. Test sat.
Engineering
Issued 17 November 2003
Resolved
Show proof of Maintenance Record for the past year
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 15 December 2003
Resolution: Showed inspectors maintenance records.
Operations/Management › Drills/Instruction
Issued 17 November 2003
Resolved
Conduct Mass Evacuation drill, Fire drill, and Man overboard. Conduct/Record LEGACY COMPONENT DESC: Abandon Ship
Due 18 December 2003
Resolved 15 December 2003
Resolution: Conducted all above drills. Test sat.
Deck/Cargo › Cargo Stowage
Issued 17 November 2003
Resolved
Properly stencil and remove paint from Rubber-Maid container on aft deck. LEGACY COMPONENT DESC: Paint Locker
Due 15 December 2003
Resolved 15 December 2003
Resolution: Remove all flamable compounds, and properly labled.
Deck/Cargo › Cargo Stowage
Issued 17 November 2003
Resolved
Remove paint if not needed, keep minimum amounts of paint onboard.
LEGACY COMPONENT DESC: Paint Locker
Due 18 December 2003
Resolved 15 December 2003
Resolution: Removed paint.
Lifesaving › Buoyant Apparatus
Issued 17 November 2003
Resolved
Saftey line needs to properly stored.
LEGACY COMPONENT DESC: Life Ring
Condition: Improper Installation
Due 18 November 2003
Resolved 15 December 2003
Resolution: Line was properly stored.
Fire Fighting › Miscellaneous Items
Issued 19 August 2003
Resolved
Perform PMS on fire station #17 door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 11 September 2003
Resolution: Performed maintainance on door.
Construction/Loadline › Structures › Door
Issued 19 August 2003
Resolved
Perform PMS on service lobby door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 11 September 2003
Resolution: Performed PMS on service lobby door.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 19 August 2003
Resolved
Chief Engineer had posted an expired mariners license.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2003
Resolved 19 August 2003
Resolution: Current license was not posted.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 19 August 2003
Resolved
Captain had posted expired license.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2003
Resolved 19 August 2003
Resolution: Captain had not posted new/current license.
Electrical › Electrical Distribution System (service)
Issued 19 August 2003
Resolved
Remove powere strips and install fixed outlets in cages. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 11 September 2003
Resolution: Removed all power stripes from compartments on vessel.
Communications › Alarms/Indicators
Issued 19 August 2003
Resolved
Repair alarm/bell on #2 WTD in lower hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 19 October 2003
Resolution: Corrected alarm on WTD.
Construction/Loadline › Structures
Issued 19 August 2003
Resolved
Repair shoreside escape door on Texas Deck, midships. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 11 September 2003
Resolution: PMS''''d door.
Construction/Loadline › Structures
Issued 19 August 2003
Resolved
Adjust door brush on fire door, main deck, port side, aft. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 11 September 2003
Resolution: Adjusted brush for proper operation of fire door.
Documentation › Safety/Response Plans/Programs
Issued 19 August 2003
Resolved
Update FCP IAW IMO standards. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 19 October 2003
Resolution: Walked through with new FCP, all SAT
Lifesaving › Rescue Boat
Issued 15 May 2003
Resolved
Renew/ replace outboard propeller on bow rescue boat. LEGACY COMPONENT DESC: Propeller
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 3 March 2004
Electrical › Lighting (emergency)
Issued 15 May 2003
Resolved
Repair/replace inoperative emergency lights batteries on main deck. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 3 March 2004
Electrical › Lighting (emergency)
Issued 18 February 2003
Resolved
Perform "E" light test or provide documentation of testing. LEGACY COMPONENT DESC: Lighting Branch Circuit
Due 18 March 2003
Resolved 14 March 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 18 February 2003
Resolved
Remove boxes and paper goods from passage way in hold deck. Keep all egress routes clear at all times. LEGACY COMPONENT DESC: Open Deck Space
Due 18 March 2003
Resolved 14 March 2003
Construction/Loadline › Structures
Issued 18 February 2003
Resolved
Repair/replace 3rd deck exterior door on starboard side at egress ramp. LEGACY COMPONENT DESC: Door
Due 18 March 2003
Resolved 14 March 2003
Operations/Management › Equipment Service/Testing
Issued 18 February 2003
Resolved
Clean all smoke detectors of lint and provide a plan for regular maintence to prevent lint build up.
Due 18 March 2003
Resolved 14 March 2003
Construction/Loadline › Structures
Issued 18 February 2003
Resolved
Repair roll down doors under forward stairtower. Remove flammable material from storage area. LEGACY COMPONENT DESC: Door
Due 18 March 2003
Resolved 3 March 2004
Fire Fighting › Structural - A Class Divisions
Issued 18 February 2003
Resolved
Repair/ replace fire screen door #6 on 2nd deck. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 18 March 2003
Resolved 14 March 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 18 February 2003
Resolved
Remove lockers from in front of computer room door to allow it to fully open. LEGACY COMPONENT DESC: Open Deck Space
Due 18 March 2003
Resolved 14 March 2003
Engineering › Bilge Water Management System
Issued 19 November 2002
Resolved
Provide working vacum gauge on primary bilge pump. LEGACY COMPONENT DESC: Pump
Due 19 December 2002
Resolved 25 November 2002
Electrical › Electric Generation Source (service)
Issued 19 November 2002
Resolved
Prove proper operation of starboard genset low oil and overspeed shutdowns.
Due 19 December 2002
Resolved 21 November 2002
Fire Fighting › Automatic Sprinkler System
Issued 19 November 2002
Resolved
Adjust/renew packing on main sprinkler pump. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 19 November 2002
Resolved 26 November 2002
Fire Fighting › Structural Fire Protection - General
Issued 19 November 2002
Resolved
Provide fire load calculations inventory to verify onboard fireload
Due 19 December 2002
Resolved 26 December 2002
Electrical › Electrical Distribution System (service)
Issued 19 November 2002
Resolved
Provide log of ground faults found on each Chief Engineer watch and when and how corrected. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 25 November 2002
Fire Fighting › Fire Patrol
Issued 30 August 2002
Resolved
Repair pull station in hold deck. LEGACY COMPONENT DESC: Call Points
Due 30 September 2002
Resolved 30 September 2002
Electrical › Electric Generation Source (service)
Issued 30 August 2002
Resolved
Clear ground indication found on lighting circuit. LEGACY COMPONENT DESC: Ground Detection
Due 30 September 2002
Resolved 30 September 2002
Lifesaving › Rescue Boat
Issued 30 August 2002
Resolved
Repair/ replace rescue boat (forward) propeller. LEGACY COMPONENT DESC: Propeller
Due 30 September 2002
Resolved 30 September 2002
Accommodation/Occupational Safety › Messroom
Issued 30 August 2002
Resolved
Clean under ice box in 2nd deck galley (Quiznos).
Due 30 September 2002
Resolved 30 September 2002
Electrical › Electrical Distribution System (service)
Issued 30 August 2002
Resolved
Trace data cable in 2nd deck service. Determine if it is still in use. LEGACY COMPONENT DESC: Cable
Due 30 September 2002
Resolved 30 September 2002
Documentation › Safety/Response Plans/Programs
Issued 30 August 2002
Resolved
Provide an updated and correct fire and safety plan. LEGACY COMPONENT DESC: Fire Control Plans
Due 30 September 2002
Resolved 30 September 2002
Documentation › Safety/Response Plans/Programs
Issued 30 August 2002
Resolved
Provide an updated and correct fire and safety plan in accordance with subchaper W. LEGACY COMPONENT DESC: Fire Control Plans
Due 30 September 2002
Resolved 30 September 2002
Fire Fighting › Miscellaneous Items
Issued 30 August 2002
Resolved
Repair pull station in hold deck (5-32).
Due 30 September 2002
Resolved 30 September 2002
Electrical › Lighting (service)
Issued 30 August 2002
Resolved
Clear ground indication found on lighting circuit. LEGACY COMPONENT DESC: Ground Detection
Due 30 September 2002
Resolved 30 September 2002
Lifesaving › Rescue Boat
Issued 30 August 2002
Resolved
Repair/replace rescue boat (forward) propeller. LEGACY COMPONENT DESC: Propeller
Due 30 September 2002
Resolved 30 September 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 30 August 2002
Resolved
Clean under ice box in 2nd deck galley.
Due 30 September 2002
Resolved 30 September 2002
Electrical › Electrical Distribution System (service)
Issued 30 August 2002
Resolved
Trace data cable in 2nd deck service bar. (dead ended cable?) LEGACY COMPONENT DESC: Wiring
Due 30 September 2002
Resolved 30 September 2002
Electrical › Electric Generation Source (service)
Issued 26 February 2002
Resolved
Prove proper operation of starboard generator overspeed trip shutdown. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Lifesaving › Rescue Boat
Issued 26 February 2002
Resolved
Prove load rating of rescue boat hooks is equal to davit rating on both bow and stern boats. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Lifesaving › Rescue Boat Equipment
Issued 26 February 2002
Resolved
Replace/repair spot light on rescue boat. (on/off switch inoperative) LEGACY COMPONENT DESC: Electric Torch
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Operations/Management › Drills/Instruction
Issued 26 February 2002
Resolved
Provide documentation of qualification of senior deck hand. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Fire Fighting
Issued 27 November 2001
Resolved
Provide proper level of AEVADS for upper outside deck._x001C_
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Fire Fighting
Issued 27 November 2001
Resolved
Complete check list for fire dampers.
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Fire Fighting
Issued 27 November 2001
Resolved
Conduct fire and boat drills._x001C_
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Fire Fighting
Issued 27 November 2001
Resolved
Repair smoke extraction system to have fire screen doors open at no more then 30 LBS pull.
Condition: Unknown
Due 8 May 2002
Resolved 3 June 2002
Fire Fighting
Issued 27 November 2001
Resolved
Repair internal of sprinkler system storage tank as per manufactures recommendations.
Condition: Unknown
Due 27 November 2002
Resolved 30 August 2002
Lifesaving
Issued 27 November 2001
Resolved
Renew or remove hydro releases for all life rafts._x001C_
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Fire Fighting
Issued 27 November 2001
Resolved
Repair latches on both doors for A/C room._x001C_
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Fire Fighting
Issued 18 September 2001
Resolved
Post operating instructions for fixed CO2 system at manual location._x001C_
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Electrical
Issued 18 September 2001
Resolved
Complete required maintenance on emergency lighting._x001C_
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 18 September 2001
Resolved
Repair STB forward door on texas deck._x001C_
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Fire Fighting
Issued 20 February 2001
Resolved
Repair the following fire screen doors. 2nd deck; Stb Fwd: Upper deck; Stb midship fwd: Texas deck; Stb midship, fwd, Stb fwd: Hurricane deck; aft port._x001C_
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Electrical
Issued 20 February 2001
Resolved
Install proper preheater for Emergency generator._x001C_
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Lifesaving
Issued 20 February 2001
Resolved
Install float collar on stokes litter._x001C_
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Accommodation/Occupational Safety
Issued 30 November 1999
Resolved
PROPERLY SECURE PLUGS FOR SOLENOID VALVES FOR SERVICE ELEVATOR. SECURE ANDSTOP ALL HYDRAULIC LEAKS IN SPACE.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Electrical
Issued 30 November 1999
Resolved
VERIFY/INSTALL EMERGENCY LIGHTING IN BAR SERVICE AREAS.
Condition: Unknown
Due 16 December 1999
Resolved 4 January 2000
Accommodation/Occupational Safety
Issued 30 November 1999
Resolved
SECURE ALL LEAKS IN ELEVATOR PITS. HYDRAULIC RAMS TO BE PROPERLY SEALED_x001C_ SO AS NOT TO REQUIRE DRAIN BUCKETS OR SORBENT RAGS TO COLLECT HYDRAULIC OIL.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Electrical
Issued 30 November 1999
Resolved
INSTALL EMERGENCY LIGHTS IN ALL FWD STAIR TOWERS.
Condition: Unknown
Due 16 December 1999
Resolved 4 January 2000
Fire Fighting
Issued 30 November 1999
Resolved
PROVE PROPER OPERATION OF CO2 DISCHARGE ALARM FOR EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 10 December 1999
Resolved 4 January 2000
Accommodation/Occupational Safety
Issued 15 September 1999
Resolved
MAIN DECK BAR TO REMAIN CLOSED UNTIL PROPERLY SANITIZED.
Condition: Unknown
Due 15 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 15 September 1999
Resolved
REPAIR CEILING GRID ON HOLD DECK IN ALL SPACES THAT HAVE DROPPED CEILINGS TO ENSURE SPRINKLER HEADS WILL ADEQUATELY COVER DESIGNED SPRAY PATTERN.
Condition: Unknown
Due 29 September 1999
Resolved 14 October 1999
Fire Fighting
Issued 15 September 1999
Resolved
REPAIR/REPLACE FIRE STATION #2 CABINET ON HURRICANE DECK.
Condition: Unknown
Due 29 September 1999
Resolved 14 October 1999
Fire Fighting
Issued 15 September 1999
Resolved
SUBMIT PROPOSAL TO ADDRESS SHORESIDE FIREFIGHTING ASSISTANCE.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 15 September 1999
Resolved
PROPERLY INSTALL SPRINKLER HEAD IN DROP CEILING OF UPPER DECK CASH CAGE.
Condition: Unknown
Due 29 September 1999
Resolved 20 September 1999
Lifesaving
Issued 15 September 1999
Resolved
PREPARE POTABLE WATER TANK FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 29 June 1999
Resolved
REPLACE BROKEN/FRACTURED PADDLE WHEEL BOARDS AND PROVIDE COPY OF NUMBER REPLACED TO OCMI.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 29 June 1999
Resolved
SERVICE/REPAIR SERVICE ELEVATOR EMERGENCY ALARM AND PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Fire Fighting
Issued 29 June 1999
Resolved
PROVIDE AND DEMONSTRATE SMOKE DETECTION IN HIGH LIMIT CAGE AREA, HOLD MEN'SHEAD AND UPPER DECK CLUB ROUGE.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Lifesaving
Issued 29 June 1999
Resolved
REPLACE AFT RESCUE BOAT PROPELLER.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Fire Fighting
Issued 15 March 1999
Resolved
PROVIDE MAINTENANCE, INSPECTION AND TESTING RECORDS FOR INSTALLED AUTOMATICSPRINKLER SYSYEM IN ACCORDANCE WITH NFPA 25.
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Fire Fighting
Issued 15 March 1999
Resolved
SUBMIT PROPOSAL TO [name withheld] TO RELOCATE OBSTRUCTED SPRINKLER HEADS IN WAY OF NEWLY REMODELED HEADS. (MENS HEAD MAIN DECK SPRINKLER HEAD LOCATIONS ARE ACCEPTABLE)
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Accommodation/Occupational Safety
Issued 15 March 1999
Resolved
CLEAN AND SANITIZE ALL BAR AREAS ON ALL DECKS.
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Electrical
Issued 2 December 1998
Resolved
Properly install ROX blocks on wire runs in hold area.
Condition: Unknown
Due 8 December 1998
Resolved 5 January 1999
Fire Fighting
Issued 2 December 1998
Resolved
Remove money cabinet in way of sprinkler head in hard count room.
Condition: Unknown
Due 9 December 1998
Resolved 5 January 1999
Fire Fighting
Issued 2 December 1998
Resolved
Prove proper operation of AEVADs/fire alarm system.
Condition: Unknown
Due 9 December 1998
Resolved 5 January 1999
Lifesaving
Issued 2 December 1998
Resolved
Repair/replace bow light on forward rescue boat.
Condition: Unknown
Due 8 December 1998
Resolved 5 January 1999
Lifesaving
Issued 2 December 1998
Resolved
Provide apparoved PFDs other than work vests for use on rescue boats.
Condition: Unknown
Due 2 December 1998
Resolved 5 January 1999
Electrical
Issued 2 December 1998
Resolved
Eliminate the extension cord for the air compressor located at beverage store room.
Condition: Unknown
Due 2 December 1998
Resolved 5 January 1999
Fire Fighting
Issued 2 December 1998
Resolved
Prove proper operation of fire hydrant valve at fire station #17.
Condition: Unknown
Due 9 December 1998
Resolved 5 January 1999
Construction/Loadline
Issued 2 December 1998
Resolved
Make "Z" drive space watertight.
Condition: Unknown
Due 9 December 1998
Resolved 5 January 1999
Fire Fighting
Issued 2 December 1998
Resolved
Prove proper operation of weather deck doors at Texas deck.
Condition: Unknown
Due 8 December 1998
Resolved 5 January 1999
Electrical
Issued 2 December 1998
Resolved
Provide proper packing at fiber optic cable stuffing tube at "Z" drive.
Condition: Unknown
Due 2 December 1998
Resolved 5 January 1999
Lifesaving
Issued 2 December 1998
Resolved
Provide securing rack for spare fire extinguishers. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 December 1998
Resolved 5 January 1999
Lifesaving
Issued 22 September 1998
Resolved
Properly secure oxygen and acesetlene tanks.
Condition: Unknown
Due 29 September 1998
Resolved 13 October 1998
Engineering
Issued 22 September 1998
Resolved
Prove proper operation of all main engines and generator engines safety alarms.
Condition: Unknown
Due 29 September 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Replace float light on starboard ring buoy station at bridge deck.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Properly secure and replace wires with broken insulation on batteries in bow and stern rescue boats.
Condition: Unknown
Due 1 October 1998
Resolved 13 October 1998
Construction/Loadline
Issued 22 September 1998
Resolved
Prove proper operation of emergency exit door located at bow Texas deck.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Provide run indicator light for hydraulic fluid aux. cooling fan with display in the EOS.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Properly mount "Big Six Wheel" to deck using approved marine installation methods. Provide bracing near top of wheel to prevent wheel from tipping.
Condition: Unknown
Due 8 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Replace broken glass in EOS room doors.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Navigation
Issued 22 September 1998
Resolved
Repair lens cover on stern light and install handle on light switch on stern rescue boat.
Condition: Unknown
Due 1 October 1998
Resolved 13 October 1998
Engineering
Issued 22 September 1998
Resolved
Replace warped guage faces on bridge wing control stations.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Electrical
Issued 22 September 1998
Resolved
Remove improperly installed electrical outlet located starboard side midwayalong starboard side of vessel on upper deck.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
The vessel is limited to one thousand total persons until the inflatable buoyant apparatus are properly inspected and installed aboard the vessel. The total persons may be increased by 500 persons per properly installed and inspected bouyant apparatus.
Condition: Unknown
Due 22 October 1998
Resolved 13 October 1998
Lifesaving
Issued 22 September 1998
Resolved
Relocate the "Big Six Wheel Table" to provide adequate access to fire station #29.
Condition: Unknown
Due 8 October 1998
Resolved 13 October 1998
Engineering
Issued 28 July 1998
Resolved
PROPERLY REPAIR TO GOOD WORKING ORDER THE STBD Z-DRIVE. VESSEL MAY SAIL PROVIDED AN ASSIST TUG IS READILY AVAILABLE FOR VESSEL SAFETY WHEN UNDERWAY.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Accommodation/Occupational Safety
Issued 23 June 1998
Resolved
ICE MACHINE PLUMBING NEEDS REPAIR ON BAR 3RD DECK.
Condition: Unknown
Due 23 July 1998
Resolved 7 July 1998
Electrical
Issued 23 June 1998
Resolved
REPAIR/REPLACE BROKEN LIGHTS OVER BAR ON MAIN DECK.
Condition: Unknown
Due 6 July 1998
Resolved 7 July 1998
Construction/Loadline
Issued 23 June 1998
Resolved
PROVE PROPER OPERATION OF ALL WEATHER DECK DOORS AS APPLICABLE.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 23 June 1998
Resolved
RESUPPORT GRID SYSTEM IN SUPERVISOR OFFICE HOLD DECK AS TO NOT INTERFERE WITH SPRINKLER HEAD.
Condition: Unknown
Due 6 July 1998
Resolved 7 July 1998
Fire Fighting
Issued 23 June 1998
Resolved
PROVE PROPER OPERATION OF AFT PORT SIDE DOORS ON SECOND DECK WITH SMOKE EXTRACTION SYSTEM IN OPERATION. (MUST OPEN WITH LESS THAN 30 LBS PRESSURE.)
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Fire Fighting
Issued 23 June 1998
Resolved
PROVIDE UPDATED FIRE LOAD CALCULATIONS FOR MIS DC SPACE.
Condition: Unknown
Due 23 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 23 June 1998
Resolved
BOW THRUSTER FWD HEAT DETECTOR INOPERABLE. (DISCONNECTED)
Condition: Unknown
Due 6 July 1998
Resolved 7 July 1998
Engineering
Issued 23 June 1998
Resolved
PROVE PROPER OPERATION OF STARBOARD Z-DRIVE INDICATOR AND PORT Z-DRIVE DIRECTION INDICATOR AT PORT BRIDGE WING CONTROL STATION.
Condition: Unknown
Due 6 July 1998
Resolved 7 July 1998
Accommodation/Occupational Safety
Issued 23 June 1998
Resolved
CLEAN AND SANITIZE ALL BAR AREAS.
Condition: Unknown
Due 23 July 1998
Resolved 7 July 1998
Navigation
Issued 23 June 1998
Resolved
REPAIR/REPLACE 2ND DECK BRIDGE CALL BOX.
Condition: Unknown
Due 23 July 1998
Resolved 7 July 1998
Fire Fighting
Issued 23 June 1998
Resolved
PROVE PROPER OPERATION OF ALL FIRE SAFETY DOORS AS APPLICABLE.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Engineering
Issued 30 March 1998
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Engineering
Issued 30 March 1998
Resolved
REPAIR COOLING WATER LEAK AT CYLINDER HEAD ON #2 GENERATOR.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Engineering
Issued 2 January 1998
Resolved
REPAIR HEAT EXCHANGER FOR BOW THRUSTER AND PROVE PROPER OPERATION.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Engineering
Issued 2 January 1998
Resolved
REPAIR / REPLACE LUBE OIL PUMP FOR PADDLEWHEEL PRIME MOVER GEARBOX AND PROVE PROPER OPERATION.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Engineering
Issued 2 December 1997
Resolved
PROVIDE DOCUMENTATION OF TESTING OF OVERSPEEDS AND L/O SHUTDOWNS BY TECH REP ON ALL PROPULSION AND GENERATOR PRIME MOVERS. PROVE PROPER OPERATION IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 15 December 1997
Resolved 23 December 1997
Engineering
Issued 20 October 1997
Resolved
INSTALL AND PROVE PROPER OPERATION OF THE THRUST GAUGES AT THE CONTROL STATION IN THE EOS.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Engineering
Issued 9 October 1997
Resolved
INSTALL AND PROVE PROPER OPERATION OF THE THRUST GAUGES AT THE CONTROL STATION IN THE EOS.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAY ON #1 AND #2 GENERATORS.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 27 March 1997
Resolved
PROPERLY SECURE OVERHEAD WIRING IN CREW BREAK ROOM, CCTV SPACE AND MIS SPACE.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 25 February 1997
Resolved
Coordinate with the Marine Safety Center to have the vessel's new lightshipcharacteristics evaluated due to an approx. 20 ft. change in the vessel's LCG.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Accommodation/Occupational Safety
Issued 3 December 1996
Resolved
CLEAN AND SANTIZE UNDER BEVERAGE DISPENSER AND REEFER IN CREWS BREAK ROOM.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Accommodation/Occupational Safety
Issued 3 December 1996
Resolved
MOUNT WATER FILTER TO ICE MACHINE IN HOLD SERVICE LOBBY IN A PERMANENT MANNER.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Accommodation/Occupational Safety
Issued 3 December 1996
Resolved
SECURE TO THE BULKHEAD THE CANDY AND FOOD MACHINES IN THE HOLD SERVICE LOBBY.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Engineering
Issued 3 December 1996
Resolved
REPAIR THE LOW LUBE OIL PRESSURE ALARM TO THE STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Electrical
Issued 3 December 1996
Resolved
PROPERLY SECURE ELECTRICAL CABLES IN OVERHEAD IN WAY OF RECENT MODIFICATIONOF CCTV ROOM.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Electrical
Issued 3 December 1996
Resolved
PROPERLY REPACK ROX BLOCK IN HVAC ROOM AFT OF PILOTHOUSE.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Lifesaving
Issued 3 December 1996
Resolved
PROVIDE OSHA AND NFPA APPROVAL FOR PAINT LOCKER LOCATED NEAR PADDLEWHEEL ORREMOVE.
Condition: Unknown
Due 12 December 1996
Resolved 9 December 1996
Accommodation/Occupational Safety
Issued 3 December 1996
Resolved
SECURE BEVERAGE LEAK IN WAY OF SODA DISPENSER IN CREWS BREAK ROOM.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Lifesaving
Issued 23 September 1996
Resolved
PROVE PROPER OPERATION OF "AEVADS" IN ACCORDANCE WITH NVIC 8-93.
Condition: Unknown
Due 23 September 1996
Resolved 23 September 1996
Electrical
Issued 23 September 1996
Resolved
PROPERLY SECURE ELECTRICAL POWER WIRES TO THE JACKET WATER HEATER ON THE #1SSDG.
Condition: Unknown
Due 23 September 1996
Resolved 23 September 1996
Engineering
Issued 23 September 1996
Resolved
REPLACE EMERGENCY FUEL OIL SHUT-OFF VALVES, FROM REMOTE LOCATION, VALVE WRENCH.
Condition: Unknown
Due 23 September 1996
Resolved 23 September 1996
Electrical
Issued 23 September 1996
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR ENGINE'S EMERGENCY STOP SWITCH.
Condition: Unknown
Due 23 September 1996
Resolved 23 September 1996
Engineering
Issued 23 September 1996
Resolved
PROVIDE DOUBLE CLAMP PROTECTION TO RAW WATER SUPPLY/DISCHARGE HOSES ON PADDLEWHEEL HYDRAULIC OIL COOLER.
Condition: Unknown
Due 23 September 1996
Resolved 23 September 1996
Engineering
Issued 19 August 1996
Resolved
MAKE PROPER REPAIRS AND PROVE OPERATION TO THE HYDRAULIC PADDLEWHEEL. IF THE CAPTAIN IS NOT FEELING SAFE WITHOUT PADDLEWHEEL OPERATION, THE VESSEL_x001C_ SHOULD NOT GET UNDERWAY.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 25 June 1996
Resolved
REPLACE PAINTED SPRINKLER HEADS IN BEVERAGE SYSTEM LOCKER (3) AND IN STBD HOLD CORRIDOR ENTRANCE FROM WX DECK (1).
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Fire Fighting
Issued 25 June 1996
Resolved
PROVIDE SPARE SPRINKLER HEADS IAW NFPA 13 & NFPA 25.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Accommodation/Occupational Safety
Issued 25 June 1996
Resolved
Repair all hardware to 03 hold access doors on main deck starboard side near ramp.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Electrical
Issued 25 June 1996
Resolved
REPLACE MISSING CIRCUIT DIRECTORIES IN POWER PANELS: SP203(update), SP205, SP206, AND SP207.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Fire Fighting
Issued 25 June 1996
Resolved
REPLACE MISSING FIRE EXTINGUISHER IN SOFT COUNT ROOM.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Electrical
Issued 25 June 1996
Resolved
REPAIR/REPLACE E-LIGHT IN SOFT COUNT ROOM.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 5 March 1996
Resolved
Repair starboard Z drive and prove satisfactory operation. Vessel is to remain dockside when Z drive unit fails or is disabled.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Navigation
Issued 29 December 1995
Resolved
MAKE PERMANENT REPAIRS TO THE PORT Z-DRIVE/STEERING UNIT, PROVE PROPER OPERATION TO THE SATISFACTOIN OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 January 1996
Resolved 4 January 1996
Engineering
Issued 13 December 1995
Resolved
Repair starboard Z drive and prove satisfactory operation. Vessel is to remain dockside when Z drive unit fails or is disabled.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Engineering
Issued 4 December 1995
Resolved
Repair the starboard Z drive. Prove proper operation of the starboard Z drive. If the starboard Z drive fails to operate, vessel must remain dockside.
Condition: Unknown
Due 4 December 1995
Resolved 5 December 1995
Engineering
Issued 24 November 1995
Resolved
MAKE PERNMANENT REPAIRS TO VESSEL'S INSTALLED PADDLEWHEEL PROPULSION HYDRAULIC SYSTEM.
Condition: Unknown
Due 24 November 1995
Resolved 24 November 1995
Construction/Loadline
Issued 20 October 1995
Resolved
MAKE PROPER REPAIRS TO CRACK ON BOW THRUSTER. ONCE REPAIRS ARE STARTED, VESSEL IS RESTRICTED TO DOCK. VESSEL AUTHORIZED TO SAIL UNDER THE FOLLOWINGCONDITIONS: ELECTRICALLY ISOLATE BOW THRUSTER RM, POST A WATCH WITH COMMS,LIMIT VESSEL'S ROUTE,PROVIDE A TUG STANDING BY,& A SUITABLE PUMP.
Condition: Unknown
Due 20 October 1995
Resolved 21 October 1995
Fire Fighting
Issued 28 September 1995
Resolved
Provide correct number of and type of spare sprinkler heads and wrenches inaccordance with NFPA 13.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Accommodation/Occupational Safety
Issued 28 September 1995
Resolved
Replace missing tags on relief valves on hot water heaters in AMR.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Fire Fighting
Issued 28 September 1995
Resolved
Replace sprinkler heads that have been painted. Two in beverage locker and one in vestible aft of crew break room.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Accommodation/Occupational Safety
Issued 28 September 1995
Resolved
Repair hydraulic ram to texas deck service ramp & clean up hydraulic oil.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Navigation
Issued 28 August 1995
Resolved
Your operational route is amended/endorsed to the Mississippi River, eastern portion of the navigable channel between river mile 230.0 & 231.4. The western portion may be used to clear river traffic only. A tug off adequate horsepower under contract and immediately available.
Condition: Unknown
Due 26 September 1995
Resolved 27 October 1995
Engineering
Issued 28 August 1995
Resolved
Your vessel is restricted from sailing. You are to remain dockside until all propulsion and steering machinery are repaired or an acceptable alternative propulsion/steering system is installed.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 August 1995
Resolved
Make permanent repairs and prove proper operation of the Z drive propulsionsteering system. Proper operation to be witnessed by a USCG marine inspector.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 August 1995
Resolved
Make permanent repairs and prove proper operation of the gear box unit/hydraulic pump drive for the paddlewheel propulsion and bow thruster units. Proper operation is to be witnessed by a USCG marine inspector.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Documentation
Issued 28 August 1995
Resolved
You are require to provide a detailed written report, laying out the cause of problems with the STBD Z-Drive unit; repairs to combat problems and the actions taken for long term operation.
Condition: Unknown
Due 26 September 1995
Resolved 27 October 1995
Electrical
Issued 3 July 1995
Resolved
Repair elevator unit, port side, where by normal operation is acheived.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Accommodation/Occupational Safety
Issued 3 July 1995
Resolved
Repair crew door located on main deck stbd side to hold corridor.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Electrical
Issued 3 July 1995
Resolved
Prove proper operation and mark emergency lighting; install lighting over P/S Z-Drive units. Repair bilge alarm switch.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Lifesaving
Issued 27 March 1995
Resolved
PROVE DATE OF MANUFACTURE/EXPIRATION DATE OF HYDROSTATIC RELEASES ON ALL INFLATABLE BUOYANT APPARATUS.
Condition: Unknown
Due 27 April 1995
Resolved 3 May 1995
Fire Fighting
Issued 27 March 1995
Resolved
PROVIDE ENCLOSURES/PROTECTION FOR CO2 BOTTLES IN FIXED SYSTEMS; AND PROVIDELIFTING POINT FOR WEIGHING CYLINDERS. EMERG. GEN. BOTTLES TO BE PROTECTED FROM WEATHER. BOTTLES IN Z-DRIVE SPACE TO BE PROTECTED FROM ACCIDENTAL DISCHARGE.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 27 March 1995
Resolved
INSTALL FIRE DEPARTMENT SHORE CONNECTION FOR SPRINKLER SYSTEM ON PORT SIDE IAW NVIC 10-93.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 17 February 1995
Resolved
upon proper installation of the P/S flush & steering pumps for subject vessels' Z-drives (port/stbd) in all modes prior to 03 Mar 95
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Electrical
Issued 6 January 1995
Resolved
INSTALL TEST SWITCH AT EMERGENCY SWITCHBOARD IAW 46 CFR 112.45-5 AND PROVE PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Documentation
Issued 23 December 1994
Resolved
PROVIDE APPROVED PLANS FOR THE Z-DRIVE HYDRAULIC DIAGRAM (V) REV "C" AND EMERGENCY GENERATOR MANUALS.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Construction/Loadline
Issued 23 December 1994
Resolved
REPLACE TEMPORARY REPAIR TO BOTTOM PLATE PUNCTURE IN #1 PORT BALLAST TANK WITH A PERMANENT INSERT AT NEXT DRYDOCK.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Engineering
Issued 23 December 1994
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Documentation
Issued 23 December 1994
Resolved
SUBMIT REVISED DOCKSIDE EVACUATION PLAN TO OCMI FOR APPROVAL.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Documentation
Issued 23 December 1994
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION PRIOR TO CARRIAGE OF ANY PASSENGERS.
Condition: Unknown
Due 27 December 1994
Resolved 3 January 1995
Navigation
Issued 23 December 1994
Resolved
CONDUCT RIVER TRIALS DURING HIGH WATER PERIOD TO DETERMINE IF AN ADDITIONALSTEERING SYSTEM WILL BE REQUIRED.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994
Documentation
Issued 23 December 1994
Resolved
SUBMIT REVISED PERIODIC TEST PROCEDURES FOR SMOKE EXTRACTION SYSTEM TO OCMIFOR APPROVAL.
Condition: Unknown
Due 23 December 1994
Resolved 23 December 1994