BUFFALO GIRL

BUFFALO GIRL is a 1967 towing vessel. The Coast Guard has recorded 25 inspections since 1993, most recently in June 2025, along with 23 deficiencies, 1 operational control and 4 casualty investigations between 2002 and 2014.

Records from 1993 to 2025. Most recent: inspection, 23 June 2025.

Built
1967
Last inspected
23 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ7652
Flag
UNITED STATES
Maury page id
psix-93724

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded12
Years with a record 18 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)68.8 ft × 22.2 ft × 6.2 ft
Registered tonnagegross 63 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
63 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 6

Inspection history · 25

23 June 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8165239
28 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8146232
7 June 2024 DAPI Audit · Deficiency Check · Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7930555
7 July 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7735277
7 July 2022 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7504577
5 July 2022 Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7496662
13 October 2021 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7332112
25 May 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7206556
10 April 2014 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4833293
24 January 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4789436
28 September 2013 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4733238
14 April 2011 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3986482
14 November 2008 Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363404
5 July 2007 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2983953
15 June 2007 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2962810
18 August 2006 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2758182
10 February 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2025066
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977781
7 July 2003 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1838481
29 November 2002 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1713658
5 April 2002 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1615361
17 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 212780
6 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 21716
28 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 175300
9 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 38409

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 8 June 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. A hole from the aft STBD void to the stern void was noted.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 June 2025
Resolution: MI verified repairs
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. Long insets have been found along the port and STBD sides of the forepeak. These insets have bent the side longs.
Action required: 30 - Ship detained
Resolved 6 June 2025
Resolution: MI verified repairs
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 8 June 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. There is a broken hand rail on the STBD push knee.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
Resolution: All broken hand rails have been rewelded. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. All tripping brackets in the forepeak have been found bent.
Action required: 30 - Ship detained
Resolved 6 June 2025
Resolution: MI verified repairs.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The general alarm has been found to be inoperable.
Action required: 30 - Ship detained
Resolved 13 June 2024
Resolution: General alarm fully funcitoning.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 8 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The fire pump has a leak coming from a valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Valve replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. There are guards removed from the front of both main diesel engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2024
Resolution: Replaced both guards on the main diesel engines. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Only one light works in the engine room. There is not enough light to move about safely.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Sufficent lightening observed in E/R.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2023 Resolved
At least two lifebuoys on a towing vessel greater than 26ft must be fitted with a floating electric water light. Vessel only had one non expired floating electric water light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2023
Resolution: Vessel replaced the expired water lights.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 7 July 2023 Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Forward tow bit has cracks in the base in multiple corners.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2023
Resolution: Grinded down to good metal and welded up the crack.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 July 2023 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. The relief valves on the pressure vessels don't have proper documentation on the last test date.
Action required: 705 - Other - as specified
Due 14 July 2023
Resolved 12 July 2023
Resolution: Vessel representative provided documentation for pressure relief devices installed on air receivers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 July 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation. Inadequate guards on both generators.
Action required: 705 - Other - as specified
Due 14 July 2023
Resolved 12 July 2023
Resolution: Additional guards installed on both auxiliary generators.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 7 July 2023 Resolved
Towing vessels must be equipped with the following equipment as applicable to the area of operation. (a) Fathometer. Vessel is not equipped with a fathometer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2023
Resolved 2 August 2023
Resolution: Received photo evidence of an installed fathometer.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 8 July 2022 Resolved
For a vessel of less than 300 tons gross tonnage that engages in towing on navigable waters of the U.S., including Western Rivers, the radar must meet- RTCM Standard for Marine Radar Equipment Installed on Ships of Less Than 300 Tons Gross Tonnage, RTCM Paper 71-95/SC112-STD, Version 1.1, display Category II and stabilization Category Bravo. The radar display at the primary conning station was not available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Radar reinstalled, verified safe operation. To the satisfaction of the marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2022 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. There was no day shapes on board the vessel for conditions of reduced maneuverability.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Purchased day shapes, MI verified ability to display.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 July 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. There was a through bulkhead penetration on the starboard side, just aft of the engine room watertight door that did was not properly blanked off, additionally the forward port port-light for the engine room was sealed with silicone, which is not approved to keep the bulkhead watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Through hull penetration secured with threaded plug.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 July 2022 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. The vessel’s company was unable to provide proof of the crewmembers on board during the inspection were currently enrolled in the companies drug testing program and was not able to provide annual numbers of individuals chemically tested with a MIS (Management Information System) report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: MI verified company in compliance with drug and alcohol program.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2022 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Missing section of main exhaust insulation at multiple locations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Reinstalled adequate lagging.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 July 2022 Resolved
Alarms must: (1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. No visible alarm at control stations.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Installed visible alarm at control station, MI verified operation.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 July 2022 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include - (1) Closing the seacock and removing the handle; (2) Padlocking the seacock in the closed position; (3) Using a non-releasable wire-tie to hold the seacock in the closed position; or (4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock. Missing seacock valve in piping system and means to secure and lock overboard discharge.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Locked was procured and verified by the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 July 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Main deck water tight doors (P/S, fore and aft), do not seal properly due to improper mounting and/or mis-aligned dogs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: All dogs and gaskets were reworked and found statisfactor, MI witnessed hose test.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 July 2022 Resolved
Towing vessels not subject to the provisions of 33 CFR part 26 or 33 CFR 164.72 must have a Very High Frequency-Frequency Modulated (VHF-FM) radio installed and capable of monitoring VHF-FM Channels 13 and 16, except when transmitting or receiving traffic on other VHF-FM channels, when participating in a Vessel Traffic Service (VTS), or when monitoring a channel of a VTS. The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. Neither control station had a VHF radio connected to battery back-up power.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 August 2022
Resolution: Batterys installed, MI verified and tested satsifactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2021 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 August 2021
Resolved 18 August 2022
Resolution: COI issued and effective 08JULY22.

Casualty record · 4

5 April 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1615361
15 June 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2962810
28 September 2013Routine · role: Involved in a Marine Casualty · activity 4733238
24 January 2014Routine · role: Involved in a Marine Casualty · activity 4789436
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.