MAURY USCG vessel records Sign in
← All vessels

MAERSK ARIZONA

MAERSK ARIZONA is a 1975 freight ship. The Coast Guard has recorded 102 inspections since 1987, most recently in June 2006, along with 155 deficiencies, 1 operational control and 6 casualty investigations in 2005.

Records from 1987 to 2006. Most recent: inspection, 28 June 2006.

Built
1975
Last inspected
28 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7361180 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419903
Flag
MINISTERO DEI TRANSPORTI E DELLA NAVIGAZIONE
367519000 (licence lapsed)
Maury page id
psix-419903

Inspections, by type

…with no type recorded60
Years with a record 20 calendar years (1987–2006)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it40594 - Convention (Subpart B), Gross Ton
17083 - Convention (Subpart B), Net Ton
32178 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KAKGMMSI 367519000 · expired · compulsorily equipped · granted 14 April 2005, cancelled 20 June 2015
KAKGMMSI 367519000 · terminated · compulsorily equipped · granted 29 March 1995, cancelled 14 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CELTIC Passenger (Inspected) · MISLE 46805 · 10 January 1999 · activity 133223CAROLINIAN Passenger (Inspected) · MISLE 46555 · 10 September 1998 · activity 29159

Inspection history · 102

28 June 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2694126
27 June 2006 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2693175
23 June 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2689261
21 June 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2686654
25 May 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2659635
25 May 2006 Permit to Proceed
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2664251
23 February 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2592546
13 February 2006 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2584359
27 September 2005 Type not recorded
No type recorded · Activities Europe · Activity 2592585
9 July 2005 Type not recorded
No type recorded · Activities Europe · Activity 2592429
2 July 2005 Type not recorded
No type recorded · Activities Europe · Activity 2423589
2 July 2005 Type not recorded
No type recorded · Activities Europe · Activity 2592431
2 May 2005 Type not recorded
No type recorded · Activities Europe · Activity 2361024
17 February 2005 Annual Inspection
Physical examination · Activities Europe · Activity 2274821
28 January 2005 Type not recorded
No type recorded · Activities Europe · Activity 2284172
20 December 2004 Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 2245811
11 August 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2162739
28 May 2004 Type not recorded
No type recorded · Activities Europe · Activity 2080536
18 May 2004 Administrative Inspection
Administrative · Activities Europe · Activity 2080540
11 May 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2059776
15 April 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2044365
11 April 2004 Type not recorded
No type recorded · Activities Europe · Activity 2053473
8 February 2004 Periodic Inspection
Physical examination · Activities Europe · Activity 1977209
15 January 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2159960
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979841
3 January 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1725517
30 December 2002 Administrative Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1722643
26 September 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1680955
12 September 2002 Internal Structural Exam · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1667514
5 July 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1641492
28 March 2002 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1598511
26 February 2002 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1492631
1 December 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 480261
16 November 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 771955
15 October 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1387187
10 October 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 460437
7 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417390
23 February 2001 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1059635
22 February 2001 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 176009
25 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 821813
24 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 155608
16 December 1999 Re-Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1393296
10 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 34776
27 April 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 803973
29 March 1999 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1115453
1 March 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 797074
10 February 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365052
6 February 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 9511
10 January 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 133223
25 October 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 164196
16 October 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 24147
10 September 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 29159
12 June 1998 Deficiency Check
Physical examination · Activities Europe · Activity 1127104
31 March 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1421482
13 October 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 224466
25 August 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 787958
4 August 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 108432
30 July 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1116787
11 July 1997 Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1114048
25 June 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 134841
20 June 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 157141
15 June 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 775373
28 May 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1109078
23 May 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1106157
23 May 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1108568
16 May 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1094403
19 March 1997 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1390478
1 December 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 219672
10 May 1996 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1083321
6 March 1996 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1078907
20 July 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 27625
20 July 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 120560
9 April 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 174487
9 April 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1152587
29 March 1995 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1136412
24 March 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 177693
8 October 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 371181
23 May 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 465220
22 January 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 363986
27 October 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 361907
22 August 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 360525
22 June 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 359569
4 April 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 357437
4 February 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 485101
2 September 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352969
4 February 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 348622
25 August 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 671387
2 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 343557
21 February 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 476880
4 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339693
26 July 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 338479
8 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 482333
9 August 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331939
15 June 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 331011
12 January 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 469240
19 June 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 324004
6 April 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 449133
22 October 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 436438
28 August 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 479201
18 June 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 316954
6 June 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 316605
8 April 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 315326

Deficiency record · 155

Construction/Loadline › Structures › End Bulkhead
Issued 13 February 2006 Resolved
Make permanent repairs to starboard #3 wing fuel oil tank bulkhead at frame 155.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 February 2006
Resolved 23 February 2006
Resolution: Repairs made, all sat.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 17 February 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 April 2005
Resolved 30 March 2005
Resolution: Received email from the master stating the above has been corrected. Email scanned into MISLE.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 17 February 2005 Resolved
REPLACE NON CG APPROVED HYDROSTATIC RELEASE ON THE LIFERAFT STARBOARD SIDE AFT PILOT DECK WITH COAST GUARD APPROVED
Due 17 April 2005
Resolved 30 March 2005
Resolution: Received email from the master stating the above has been corrected. Email scanned into MISLE.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 February 2005 Resolved
REPLACE NON CG APPROVED HYDROSTATIC RELEASE ON THE EPIRB WITH COAST GUARD APPROVED
Due 17 April 2005
Resolved 30 March 2005
Resolution: Received email from the master stating the above has been corrected. Email scanned into MISLE.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 17 February 2005 Resolved
REPAIR ALL HYDRAULIC LEAKS ON ANCHOR WINDLESS
Due 17 April 2005
Resolved 21 March 2005
Resolution: Received email from the Chief Engineer stating the above was corrected.
Electrical › Electric Supply System (service) › Cable
Issued 17 February 2005 Resolved
REMOVE ALL DEAD END WIRES PORT SIDE MAIN DECK IN WAY OF OVERHEAD
Due 17 April 2005
Resolved 21 March 2005
Resolution: Received email from the Chief Engineer stating the above was corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 February 2005 Resolved
ENSURE VESSEL HAS 45 LIFE JACKETS (MISSING 5 DUE TO CONDITION). VESSEL CAN'T SAIL WITH NO MORE THAN 40 POB
Condition: Placed in Improper Service
Due 17 April 2005
Resolved 30 March 2005
Resolution: Received email from the master stating the above has been corrected. Email scanned into MISLE.
Construction/Loadline › Structures › Scuttle
Issued 24 December 2004 Resolved
Repair/replace wasted hatch to engine room on port side aft of house. 23 Jun 05 Rcvd e-mail reporting Item cleared, Item will remain opened until cleared by next attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 20 December 2005
Resolution: FOUND CORRECTED ON BOARD
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 23 December 2004 Resolved
Renew/repair both bunker station booms and associated wasted platforms. Booms are down rated to 1 ton Safe working load. 23 Jun 05 Rcvd e-mail reporting Item cleared, Item will remain opened until cleared by next attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 20 December 2005
Resolution: FOUND CORRECTED ON BOARD
Engineering › Pressure Vessel › Relief Valve
Issued 23 December 2004 Resolved
Install hot water tank relief valve on Bal-95-22 Pressure vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2005
Resolved 28 February 2005
Resolution: CORRECTED
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 23 December 2004 Resolved
Replace Lifeboat First Aid kits with USCG Approved First Aid Kits.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2005
Resolved 30 March 2005
Resolution: Received email from the master stating the above has been corrected. Email scanned into MISLE.
Stability › Watertight Integrity › General
Issued 23 December 2004 Resolved
Crop and insert 500 x 500 to #3 DB fuel Oil tank as marked in #3 cargo hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2005
Resolved 25 December 2004
Resolution: Completed
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 20 December 2004 Resolved
Hydro economizer boiler to 19.5 Bar LR srveyor May witness test.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 24 December 2004
Resolution: LR witnessed test.
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2004 Resolved
Complete permanent repairs to hole in port clean bilge tank iwo sounding tube. Until this is completed, soundings of the tank shall be completed and logged daily, and the repair shall be visually inspected every 30 days. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Due 31 August 2004
Resolved 23 December 2004
Resolution: completed
Construction/Loadline › Markings › Load Line Mark
Issued 8 February 2004 Resolved
Properly mark loadline iaw Loadline Certificate.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 8 February 2004 Resolved
Weigh all 100 LB high pressure CO2 tanks.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 29 February 2004
Resolution: Done
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 8 February 2004 Resolved
Replace expired seasick medicine in lifeboats.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Done
Lifesaving › Lifeboat › Lamp (inside)
Issued 8 February 2004 Resolved
Repair interior lighting within port lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Done
Lifesaving › Lifeboat › Propulsion Starting System
Issued 8 February 2004 Resolved
Install float ball in drain for port lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 8 February 2004 Resolved
Replace all windows on port and starboard lifeboats.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Lifesaving › Lifeboat › Hatches
Issued 8 February 2004 Resolved
Repair/replace locking arm for forward hatch in STBD lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 8 February 2004 Resolved
Replace plexiglass over emergency hook release on starboard lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 8 February 2004 Resolved
Replace windshield wiper on port lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Lifesaving › Buoyant Smoke Signals › General
Issued 8 February 2004 Resolved
Provide 4 meters of adequate line between bridge quick release ring buoy and smoke signal.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Communications › Alarms/Indicators › Fire Alarm
Issued 8 February 2004 Resolved
Within wheelhouse alarm panel, mark No. 12 alarm light as spare. Replace red lens on No. 1 alarm light.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Lifesaving › Inflatable Liferafts › Float Free
Issued 8 February 2004 Resolved
Make repairs to all wasrted liferaft securing post.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected
Construction/Loadline › Hull › Side Shell
Issued 8 February 2004 Resolved
Make proper repairs to crack on bulwark iwo embarkation ladder on portside.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Construction/Loadline › Structures › Superstructure
Issued 8 February 2004 Resolved
Make proper reparis to waster bulkhead in AC room above pool.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 February 2004 Resolved
Develop, write and post proper lifeboat launching procedures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 8 February 2004 Resolved
Make repairs to all gates below lifeboats iwo embarkation ladder.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Lifesaving › Inflatable Liferafts › Float Free
Issued 8 February 2004 Resolved
All liferaft securing posts outboard of lifeboats are to be removable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected.
Construction/Loadline › Hull › Side Shell
Issued 8 February 2004 Resolved
Make proper repairs iaw repair proposals to areas damaged by loose forklift. Insert hole on Port side and renew two damaged frames on starboard.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2004 Resolved
Provide covers for all lighting where missing. (ie throughout stairtower)
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2004 Resolved
Insure all doors within stairtower close and latch upon release.
Condition: Design Flaw
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 February 2004 Resolved
Make repairs to both bridge rudder angle indicators. Prove proper operation of both indicators in FU and NFU modes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected
Construction/Loadline › Structures › Door
Issued 8 February 2004 Resolved
Make door weathertight leading into emergency switchboard room.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Lubricating Oil Service System › Piping
Issued 8 February 2004 Resolved
Clean up oil and water within emergency switchboard room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 8 February 2004 Resolved
Repair ventilation closure for CO2 room portside.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Deck/Cargo › Cargo Stowage › General
Issued 8 February 2004 Resolved
Make repairs to cracked welds on outrigger outboard of No. 6 hold portside.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 February 2004 Resolved
Replace missing gasket on hatch cover stacked above No. 5 port.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 8 February 2004 Resolved
Make paint locker exhaust vent on focsle deck vapor tight.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2004 Resolved
Replace cable conduit for anchor shackle counter Stbd side focsle.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Structures › Door
Issued 8 February 2004 Resolved
Dewater paint locker CO2 room and make door watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 29 February 2004
Resolution: Corrected.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 8 February 2004 Resolved
Remove all oil on deck and clean anchor hydraulic room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2004 Resolved
Properly secure all electrical wiring passing through anchor hydraulic room.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Structures › Superstructure
Issued 8 February 2004 Resolved
Repair wasted areas of catwalk inboard of first set of outriggers of No. 1 hold.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Fire Fighting › Means of Escape › Mimic Plans
Issued 8 February 2004 Resolved
Update fire control plans with EEBD's and lifesaving equipment. Submit to USCG once plan has been verified.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2004 Resolved
Replace all missing lighting throughout the main deck.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Fire Hoses › Condition
Issued 8 February 2004 Resolved
Provide fire hoses for all fire hoses which failed hydro test.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2004
Resolved 29 February 2004
Resolution: Corrected
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 8 February 2004 Resolved
Prove proper operation of high exhaust temperature alarms for main engines.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 8 February 2004 Resolved
Test the following equipment IAW USCG approved automations test procedures; 1. Oil fired boiler. 2. ships service generator. 3. Bowthruster interlock.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 8 February 2004 Resolved
Prove proper operation of the #1 fire/GS pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2004 Resolved
Install lagging on exhaust gas inlets to turbochargers on all generators.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2004 Resolved
Repair guardrail iwo No. 3 Diesel Generator.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Correccted.
Engineering › Bilge Water Management System › Valve
Issued 8 February 2004 Resolved
Prove proper operation of emergency bilge suction valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2004
Resolution: Corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 February 2004 Resolved
Provide weathertight closure for shore-tie cable penetration to the gym.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Heating › Radiator
Issued 8 February 2004 Resolved
Remove portable space heater from steering gear room.
Due 17 March 2004
Resolved 17 March 2004
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 8 February 2004 Resolved
Prove proper operation of emergency fuel shut-off valve for air seperating chamber.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Compressed Air System (control) › Valve
Issued 8 February 2004 Resolved
Prove proper seating of #2 start air receiver relief valve.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Securing Means
Issued 8 February 2004 Resolved
Properly secure all semi-portable fire extinguishers in engine room.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 8 February 2004 Resolved
Provide IMO placards for all firefighting/lifesaving equipment.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Freshwater Generation System › Valve, Dump
Issued 8 February 2004 Resolved
Remove storage in way of evaporator brine overboard sea valve.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2004 Resolved
Provide lighting covers for all lights within galley.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2004 Resolved
Make repairs so that fire doors on decks A, C & D all properly close and latch.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2004 Resolved
Repair door handle and latch on stairtower fire door on E deck.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 8 February 2004 Resolved
Radio Officer need to be removed from Muster & station emergency bill within the SOLAS Training Manual as vessel does not carry a radio officer.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 8 February 2004 Resolved
Update liferaft information within SOLAS Training Manual to include raft carried on board.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 February 2004 Resolved
List of ring buoys and associated equipment within SOLAS Training Manual is not in accordance with posted Safety Plan. Two ringbuoys shall have line with no light installed.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 8 February 2004 Resolved
Lifesaving signals training page within SOLAS Training Manual illegible.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 8 February 2004 Resolved
Update lifeboat launching procedures with SOLAS Training Manual.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 8 February 2004 Resolved
Prove proper operation of bilge suction within all cargo holds.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Ducts
Issued 8 February 2004 Resolved
Provide louvers on all e-gen and e-switchboard room ventilation openings to prevent water intrusion.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2004 Resolved
Properly secure light fixture 30 feet aft of port bridge wing door.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 February 2004 Resolved
Remove dead end wiring from fire damper room aft of bridge.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 8 February 2004 Resolved
Properly mount emergency battery box for radio on starboard side of stack.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 8 February 2004 Resolved
Repair hole in overhead of No.1 air intake room.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2004 Resolved
Properly mount light above door leading to gas turbine room.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2004 Resolved
Install missing ventilation fan within paint locker.
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Structures › Ventilators
Issued 8 February 2004 Resolved
Repair holed ventilation ducting for paint locker supply and exhaust ducting on focsle. Also repair holed ducting inside paint locker IWO exhaust fan.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2004 Resolved
Weather tight door leading down from pool to "B" deck does not latch closed.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Means of Escape › Doorways
Issued 8 February 2004 Resolved
Remove all hasps on outside of cabin doors to prevent locking from the outside.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 8 February 2004 Resolved
Remove portable heater from supply fan opening in the AC Compressor room.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2004 Resolved
Vent dryer exhaust within crew laundry to the weather decks.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 8 February 2004 Resolved
Install missing protective covers over heat detectors in crew laundry.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Steam Boiler (auxiliary/waste heat) › Tube Sheet
Issued 8 February 2004 Resolved
Provide repair proposal for tube sheet fracture within boiler and make approved repairs.
Condition: Damaged By Earlier Event
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 February 2004 Resolved
Submit request to amend COI to include carriage of "persons in addition to the crew".
Due 17 March 2004
Resolved 17 March 2004
Resolution: Done.
Lifesaving › Launching Appliances › Block
Issued 8 February 2004 Resolved
Prove proper operation of all sheaves on the port and starboard lifeboat.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 February 2004 Resolved
Prove calibration of critical gauges in accordance with company procedures.
Condition: Unknown
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Lifesaving › Launching Appliances › Falls
Issued 8 February 2004 Resolved
Renew port davit fall turnbuckle.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Structures › Deck Plating
Issued 8 February 2004 Resolved
Crop and renew holed/wasted overhead iwo chart table.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2004 Resolved
Remove dead-end wiring from junction box for supply power to washing machine in crew laundry.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Fire Hydrants › Location/Position
Issued 8 February 2004 Resolved
Provide additional fire hydrant(s) and associated equipment on "B" deck for fire fighting. All spaces shall be reachable by at least one length of fire hose not longer than 75 feet.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 23 December 2004
Resolution: B deck Hydrant moved closer to door.
Construction/Loadline › Structures › Cofferdam
Issued 8 February 2004 Resolved
Repair structural integrity of bunker station containment and catwalk immediately forward of the house.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2004 Resolved
Renew all wasted electrical conduit forward of house between port & stbd bunker stations.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Structures › Cofferdam
Issued 8 February 2004 Resolved
Replace wasted containment on the main deck inboard of port bunker station.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2004 Resolved
Replace all wasted steps below port bunker station.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 February 2004 Resolved
Provide cover for MDO fill pipe.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 February 2004 Resolved
Replace all holed and wasted fill pipes at port and starboard bunker stations.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2004 Resolved
Remove all non-explosion proof lights/electrical fixtures within 10 feet of port and starboard bunker stations.
Condition: Placed in Improper Service
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2004 Resolved
Modify controls for all stairtower fire doors so that the magnets do not reset once fire alarm is secured.
Condition: Design Flaw
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected.
Construction/Loadline › Penetrations › Valve Flange
Issued 30 December 2002 Resolved
Remove the non operable valve stem (port and STBD side) via the UNREP bunker station in conjunction with the next dry-dock examination.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 11 May 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 24 December 2002 Resolved
Remount all loose electrical fixtures and secure all loose wiring iwo main deck. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper Installation
Due 19 January 2003
Resolved 3 January 2003
Resolution: Cleared
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 24 December 2002 Resolved
Electrical conduit steel tubing wasted in location of the main deck. Make permanent repairs to electrical conduit iwo of main deck by replacing the all tubing and rerouting all wiring in conjunction with the next dry-dock examination. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 11 May 2004
Resolution: Corrected.
Documentation
Issued 24 December 2002 Resolved
Firefighting and life raft servicing in progress: Provide final reports to MSO Houston. LEGACY COMPONENT DESC: Servicing Reports
Due 27 December 2002
Resolved 3 January 2003
Resolution: Verified valid servicing reports.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 9 September 2002 Resolved
Prove proper operation of auxiliary heating boiler and separator boiler relief valves IAW 46 CFR 52.01-120. LEGACY COMPONENT DESC: Valve, Relief
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 26 September 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 9 September 2002 Resolved
Provide Non-destructive test (NDT) of upper tube sheet of auxiliary heating boiler IWO weld seem in vicinity of upper access port as marked. LEGACY COMPONENT DESC: Tube Sheet
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2002
Resolved 26 September 2002
Resolution: Vessel provided report attesting to repairs.
Engineering › Steering Gear System
Issued 9 September 2002 Resolved
Conduct operational test of steering system IAW SOLAS 74(A) II-1/29.3.2 (46 CFR 58.25-10(b)(2) and provide written report from [name withheld] attesting to results.
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 26 September 2002
Lifesaving › Lifeboat
Issued 9 September 2002 Resolved
Make permanent repairs to port life boat FRP hull, stb side, aft, IWO engine exhaust IAW ABS Rules for Building and Classing FRP Vessels and provide written class report attesting to proper repairs. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 7 October 2002
Resolution: Received class report Certificate No. BOA 200172/01 dated 07OCT02.
Lifesaving › Lifeboat
Issued 9 September 2002 Resolved
Port Lifeboat propulsion engine leaking fuel oil. Remove all fuel and oily waste from bilge, determine source of leak and correct. LEGACY COMPONENT DESC: Propulsion Engine
Due 12 September 2002
Resolved 9 September 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 9 September 2002 Resolved
Conduct operational test of exhaust gas boiler (economizer) safety relief valve and provide written report of test results to include lifting pressure, blowdown pressure and all safety valve name plate data. LEGACY COMPONENT DESC: Valve, Relief
Due 20 September 2002
Resolved 26 September 2002
Engineering › Pressure Vessel
Issued 7 September 2002 Resolved
Prove proper operation of pressure relief valve on start air flask BAL-95-12. (Valve failed to operate at stamped set presseure 0f 426.6 psig/30 bar) LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 7 September 2002
Resolution: Valve opened, inspected and adjusted. Observed proper operation at 426.6 psig/30 bar
Engineering › Pressure Vessel
Issued 7 September 2002 Resolved
Prove proper operation of pressure relief valve on aux. start air flask BAL-95-14. (Valve failed to operate at stamped set pressure 0f 426.6 psig/30 bar) LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 7 September 2002
Engineering › Shafting/Propeller Arrangements
Issued 7 September 2002 Resolved
Provide written report of inspection of inboard propulsion shaft seal assy. IAW 46 CFR 61.20-17(e)(2). LEGACY COMPONENT DESC: Stern Gland
Due 12 September 2002
Resolved 9 September 2002
Resolution: Vessel provide report attesting to repairs.
Construction/Loadline › Hull
Issued 7 September 2002 Resolved
Three transverse frames IWO # 3 STBD F/O tank, frame 162-164, 2nd 'tween deck, fractured and bent. Crop approx. 1 m and repair as new. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Due 12 September 2002
Resolved 9 September 2002
Construction/Loadline › Hull
Issued 7 September 2002 Resolved
#6 Port Wing Ballast tank, frame 125, 3rd 'tween deck, outboard, tripped transverse floor girder. Crop and repair as new. LEGACY COMPONENT DESC: Girder
Due 12 September 2002
Resolved 9 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 7 September 2002 Resolved
#5 Port wing ballast tank, renew all wasted ladder way safety rails. LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 12 September 2002
Resolved 9 September 2002
Engineering › Bilge Water Management System
Issued 7 September 2002 Resolved
Repair reach rod to bilge/ballast valve in fore peak tank. LEGACY COMPONENT DESC: Valve
Due 12 September 2002
Resolved 9 September 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 7 September 2002 Resolved
Clean burner assy./fuel nozzle of auxiliary boiler LEGACY COMPONENT DESC: Fuel Oil Burner
Due 12 September 2002
Resolved 9 September 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 7 September 2002 Resolved
Clean water side tube headers of auxiliary boiler. LEGACY COMPONENT DESC: Tube Header
Due 12 September 2002
Resolved 9 September 2002
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 7 September 2002 Resolved
Clean water side tube header of exhaust gas (economizer) boiler. LEGACY COMPONENT DESC: Tube Header
Due 12 September 2002
Resolved 9 September 2002
Engineering › Shafting/Propeller Arrangements
Issued 7 September 2002 Resolved
Provide written report of tail shaft bearing clearances IAW 46 CFR 61.20-17(e)(1). LEGACY COMPONENT DESC: Propeller Shaft
Due 12 September 2002
Resolved 9 September 2002
Lifesaving › Lifeboat
Issued 28 March 2002 Resolved
Port lifeboat start battery was expired
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 29 March 2002
Resolution: Port lifeboat start battery replaced and properly installed
Lifesaving › Lifeboat
Issued 28 March 2002 Resolved
Repair external battery charger connection on port lifeboat.
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 29 March 2002
Resolution: External battery charger connection on port lifeboat repaired and properly functioning.
Lifesaving › Lifeboat
Issued 28 March 2002 Resolved
Clean excessive oil from bilges in port lifeboat.
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 29 March 2002
Resolution: All oil cleaned from bilges in port lifeboat.
Lifesaving
Issued 15 October 2001 Resolved
Properly renew griping cables and clamps on port and stbd life boats.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 15 October 2001 Resolved
Install proper connections to the nine cargo hold smoke sensor lines to prevent kinking of lines.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 15 October 2001 Resolved
Properly replace manual brake release cable on port life boat.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Lifesaving
Issued 7 October 2001 Resolved
CONDUCT 110% WEIGHT LOAD TEST OF PORT LIFEBOAT DAVIT PRIOR TO DEPARTING NORSHIPCO.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Lifesaving
Issued 7 October 2001 Resolved
CONDUCT REPAIRS AND FREE UP LIFEBOAT DAVIT BRAKE RELEASE CABLE SHEAVES FOR PORT AND STARBOARD DAVITS.
Condition: Unknown
Due 7 October 2001
Resolved 7 October 2001
Lifesaving
Issued 7 October 2001 Resolved
PROPERLY INSTALL AND CONDUCT OPERATIONAL TEST OF UPPER LIMIT SWITCHES TO PORT LIFEBOAT DAVIT.
Condition: Unknown
Due 7 October 2001
Resolved 7 October 2001
Lifesaving
Issued 7 October 2001 Resolved
CONDUCT 110% WEIGHT LOAD RELEASE TEST OF PORT LIFEBOAT RELEASING GEAR IAW 46 CFR 199.190(i)(5) PRIOR TO LEAVING NEXT U. S. PORT.(SUNNY POINT, N.C.).
Condition: Unknown
Due 7 October 2001
Resolved 7 October 2001
Engineering
Issued 25 August 2000 Resolved
Vessel to operate at full engineroom manning during all periods of underwayuntil the bridge manuevering system has been repaired and tested.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Construction/Loadline
Issued 16 December 1999 Resolved
CLEAN AND GAS-FREE #3 STARBOARD FUEL TANK FOR FRAME DAMAGE INSPECTION. SIDE SHELL CREASED IN WAY OF TANK.
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Fire Fighting
Issued 16 December 1999 Resolved
PROVE PROPER OPERATION OF BOTH THE MECHANICAL AND ELECTRONIC FIRE DETECTIONSYSTEMS.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Lifesaving
Issued 16 December 1999 Resolved
PROVIDE ADDITIONAL LIFERAFTS TO ACCOMODATE FOR 100% OF THE CREW PER SIDE.
Condition: Unknown
Due 15 March 2000
Resolved 6 March 2000
Electrical
Issued 16 December 1999 Resolved
PROVIDE EXPLOSION PROOF LIGHTS FOR THE PAINT LOCKER.
Condition: Unknown
Due 15 March 2000
Resolved 6 March 2000
Electrical
Issued 10 February 1999 Resolved
Provide proof of operation of the emergency gas turbine generator after auxiliary gear shaft repairs. Proof to include testing of all alarms and shutdowns of generator and two hour load test.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Lifesaving
Issued 10 February 1999 Resolved
Crop and renew wasted and holed embarkation ladder foundation assemblies, port and stbd boat decks.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Fire Fighting
Issued 10 February 1999 Resolved
Reposition fire station #58 stand pipe discharge fitting to provide a horizontal fire hose connection vice vertical hose connections.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Lifesaving
Issued 10 February 1999 Resolved
Prove proper operation of each lifeboat searchlight.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Construction/Loadline
Issued 10 February 1999 Resolved
Crop and renew wasted brackets/gussets on box girder-bulkheads on tween decks #4, 5 and 6, #5 cargo hold.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Lifesaving
Issued 10 February 1999 Resolved
Conduct a full load weight test for each lifeboat at the upcoming shipyard period, not later than 30APR99.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Construction/Loadline
Issued 10 February 1999 Resolved
Make permanent repairs to leaky ballast pipe dresser coupling located adjacent to RPDB3-1 Reefer Distribution Board, stbd pipe tunnel.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Documentation
Issued 31 March 1998 Resolved
PROVIDE AN APPROVED CARGO SECURING MANUAL IN ACCORDANCE WITH NVIC 10-97. CURRENT MANUAL IS NOT ACCEPTABLE BECAUSE IT WAS NOT APPROVED BY AN ORGANIZATION AUTHORIZED BY THE U.S. COAST GUARD.
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Engineering
Issued 16 May 1997 Resolved
WHILE AT SEA, PROPERLY SET THE ECONOMIZER BOILER AND STEAM SEPARATOR SAFETYVALVES, AND LOG SETPOINT AND BLOWDOWN PRESSURES. PRESENT THE LOG AND HAVE THE SAFETY VALVES SEALED BY A CG MARINE INSPECTOR AT NEXT U.S. PORT.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 19 March 1997 Resolved
Service low pressure fixed CO2 system.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Accommodation/Occupational Safety
Issued 19 March 1997 Resolved
Provide servicing to elevator as per 46 CFR 111.91-1 Servicing shall be conducted as recommended by ANSI A17.1
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Lifesaving
Issued 19 March 1997 Resolved
Weight test port and starboard life boat as required by 46 CFR 199.45
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Electrical
Issued 19 March 1997 Resolved
In accordance with 46 CFR 111.75-20 provide new diffusers in-way-of lighting for passage ways and stairtowers where missing. Lights shall havediffuser/covers in accordance with UL-595 as marine approved equipment.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Lifesaving
Issued 19 March 1997 Resolved
Provide SOLAS approved lights on PFD's as per 46 CFR 199.70(b)(4)(i)
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Navigation
Issued 27 October 1993 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH A B.A. COASTPILOT VOL 68 NOT CORRECTED UP TO THE LATEST NOTICE TO MARINERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Documentation
Issued 2 May 1991 Resolved
A VIO OF 49 CFR 176.30(A)(3)(i) IN THAT THE B/O VERIFIED THAT THE PERSON SUPERVISING THE PREPERATION OF THE DCM DID NOT INCLUDE THE EMERGENCY RESPONSE TELEPHONE NUMBER
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Navigation
Issued 26 July 1990 Resolved
A vio of 33CFR164.30 in that the U.S. Coast Pilot vol. 3 used by the vsl was not corrected to ntm 23/90 which was reasonably available and containedcorrections that were applicable to the vsl's route from Cape Henlopen DE to Gloucester City NJ. No foreign equivalent o/b.
Condition: Unknown
Due 26 July 1990
Resolved 26 July 1990
Navigation
Issued 26 July 1990 Resolved
A vio of 33CFR88.05 in that the operator of the vsl did not have o/b a copyof the Inland Navigation rules while u/w in U.S. Inland waters from Cape Henlopen DE to Gloucester City NJ.
Condition: Unknown
Due 26 July 1990
Resolved 26 July 1990
Documentation
Issued 6 June 1987 Resolved
A VIO OF 33 CFR 155.740 IN THAT THE OTP REQ BY 33 CFR 155.720 WERE NOT AVAILABLE FOR INSPECTION BY THE COTP. THE VSL DID NOT HAVE ANY OTP O/B.
Condition: Unknown
Due 18 June 1987
Resolved 6 June 1987

Casualty record · 6

28 January 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2284172
2 May 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2361024
2 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2423589
2 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2592431
9 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2592429
27 September 2005Routine · role: Involved in a Marine Casualty · activity 2592585
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.