MAURY USCG vessel records
← All vessels

MM 52

Built
1995
Last inspected
12 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 12 June 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

420399
Flag
UNITED STATES
Maury page id
psix-420399

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY NASHVILLE · NASHVILLE TN, UNITED STATES · built 1995
Hull materialSteel
PropulsionUnknown
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 59 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 59

12 June 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8397821
18 February 2025 Drydock Exam · COI Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8080618
23 September 2024 In-Service Inspection · Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8007576
1 May 2024 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7903315
4 April 2023 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7662287
23 February 2023 Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7641173
13 February 2023 Permit to Proceed
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7636088
31 January 2023 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7630221
1 February 2022 Examination of Repairs · MTSA Verification · Damage Survey · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7388934
29 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7185641
5 February 2020 MTSA Verification · Administrative Inspection · COI Inspection · Examination of Repairs · Internal Structural Exam · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6903267
23 May 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6691780
16 May 2018 MTSA Verification · Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6416360
26 March 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6379042
25 May 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6127026
1 May 2017 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6136307
8 March 2016 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5829401
7 January 2015 COI Inspection · Cargo Tank Internal · MTSA Verification · Administrative Inspection · Examination of Repairs · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5049474
10 July 2014 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4917849
3 March 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4809098
10 February 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4797419
17 September 2013 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4716999
1 August 2013 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4673549
7 May 2012 Administrative Inspection · Periodic Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4304407
11 May 2010 Examination of Repairs · Internal Structural Exam · COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3736387
24 September 2009 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3602237
22 September 2009 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3601447
17 April 2009 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3454386
30 May 2008 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3222254
21 February 2007 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2875951
3 April 2006 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2610655
17 March 2005 MTSA Verification · COI Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2312838
9 September 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2191030
23 August 2004 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2163029
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997402
13 August 2003 Deficiency Check
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1875205
5 August 2003 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1861825
27 December 2002 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1723145
26 December 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1971475
20 September 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1678218
16 August 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1660476
12 July 2002 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1645247
25 April 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1370138
14 October 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 490622
26 May 2000 COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1471738
14 December 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 510739
24 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 537247
11 August 1999 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 776380
12 July 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096566
29 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1081820
10 June 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423206
24 March 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 448830
30 July 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1423056
26 June 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441256
23 March 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 499462
8 December 1996 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 130553
3 September 1996 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 941941
23 August 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439768
11 July 1995 Initial Certification · Construction Oversight · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1439639

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2025 Resolved
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted by the owner, chief engineer, or person in charge at the inspection for certification. Thermal fluid heater Low flow control switch not installed correctly.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 March 2025
Resolution: Switch re-configured and tested, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 January 2023 Resolved
During a Lock and Dam allison the vessel suffered damage to lower PORT corner of the stern void allowing water ingress. Temporary repairs have been made to approximately 5" hole. Vessel is authorized to be moved to the ERGON facility in Nashville, TN to offload current cargo and proceed directly to Mikes INC shipyard in Wood River, IL for permanent repair. Any deviation of the submitted transit plan shall be requested to the nearest OCMI zone prior to execution. Once offloaded, vessel is not authorized to conduct any further cargo operations until repairs are made to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2023
Resolution: Examined renewed 54" x 28" corner wrap port bilge knuckle in the stern void in kind. Conducted a visual exam of all repairs and witnessed air test at 1.5 PSI. Test satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 17 May 2018 Resolved
Make permanent repairs to the three small fractures in way of the port bow deck.
Condition: Damaged By Earlier Event
Action required: 703 - Prior to bunkering operations
Resolved 18 May 2018
Resolution: Examined repairs of the fracture in way of the port bow deck. Fractures were drill stopped, gouged and welded. Air test was conducted and satisfactory.
Construction/Loadline › Hull › Weld
Issued 17 May 2018 Resolved
A fractured weld on a reinforcement doubler in way of the port stern corner was fracture approximately 6-8 inches.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2018
Resolved 18 May 2018
Resolution: Attended the vessel to examine permanent repairs of weld fracture. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 1 August 2013 Resolved
Remove damaged cargo hose from barge. Do not use for any transfer. 46CFR 32.5-30
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 3 August 2013
Resolution: Hose was marked as bad, removed from service.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 1 August 2013 Resolved
Submit new test procedures for Yokogawa high temperature and operating controls.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 3 March 2014
Resolution: Received new test procedure marked "Examined" by MSC for Yokogawa high Temperature Operational Control for Thermal Fluid Heater.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 1 August 2013 Resolved
Valve position indicators on numerous valves inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 1 August 2013
Resolution: Valve position indicators repaired, witnessed via e-mail photo.
Construction/Loadline › Hull › Hull Plating
Issued 22 September 2009 Resolved
One 7 inch long crack and one two inch hole discovered in vicinity of Ullage opening of #3 Cargo Hold within the cofferdam along the STBD Side. These hull breaches are in the NON CARGO Hull plating or "weatherdeck area". During loading operations an asphalt smell and "steam" came from the opening possibly indicating a breach in the cargo envelope. But this is unseeable from the breeches.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 September 2009
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 August 2004 Resolved
Properly renew gaskets on all void hatches.
Condition: Improper/Lack of Maintenance
Due 2 September 2004
Resolved 9 September 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 August 2004 Resolved
Properly adjust all dogs on void hatches.
Condition: Improper/Lack of Maintenance
Due 2 September 2004
Resolved 9 September 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 August 2004 Resolved
Properly renew stern STBD void dog.
Condition: Damaged By Earlier Event
Due 2 September 2004
Resolved 9 September 2004
Deck/Cargo › Mooring/Anchoring › Winch
Issued 26 August 2004 Resolved
Replace port stern winch wire.
Condition: Unknown
Due 2 September 2004
Resolved 9 September 2004
Deck/Cargo › Holds/Tanks › Hatch
Issued 26 August 2004 Resolved
Properly label cargo tank hatches.
Condition: Improper/Lack of Maintenance
Due 2 September 2004
Resolved 9 September 2004
Deck/Cargo › Cargo Stowage
Issued 5 August 2003 Resolved
Restencile barge warning sign. LEGACY COMPONENT DESC: Warning Placards
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2003
Resolved 13 August 2003
Resolution: Observed properly stenciled warning sign.
Engineering › Diesel Engine (auxiliary)
Issued 5 August 2003 Resolved
Replace gauge package on prime mover LEGACY COMPONENT DESC: Gauges
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2003
Resolved 13 August 2003
Resolution: Observed new and properly operating gauge package.
Deck/Cargo › Holds/Tanks
Issued 5 August 2003 Resolved
Show proper operation of stick gauging. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2003
Resolved 13 August 2003
Resolution: Proved proper operation of stick gauging.
Engineering › Diesel Engine (auxiliary)
Issued 5 August 2003 Resolved
Install closure plugs on air box to prime mover. LEGACY COMPONENT DESC: Air intake manifold
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2003
Resolved 13 August 2003
Resolution: Observed properly installed closure plugs.
Construction/Loadline › Hull
Issued 27 December 2002 Resolved
Provide repair proposal and make proper repairs to bow, #1 and #2 stbd voids. Repair all damaged structural members and side shell. Notify MSO St. Louis if vessel is to be taken to another port for repairs prior to departing. LEGACY COMPONENT DESC: Side Shell and internal structural members
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2002
Resolved 6 January 2003
Construction/Loadline
Issued 10 June 1999 Resolved
Permanently remove loadline marking from hull at next gas freeing.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Deck/Cargo
Issued 10 June 1999 Resolved
Present thermal fluid heater for internal examination.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 10 June 1999 Resolved
Present barge when empty for inspection of side shell.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 23 August 1996 Resolved
Weld pick-ups on weather decking as indicated during inspection.
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.