Inspection history · 57
24 November 2024
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8043205
26 October 2023
DAPI Audit · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7815031
22 March 2023
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654936
23 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7625844
16 May 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7480108
5 January 2022
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7376087
4 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7345870
20 October 2021
COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7336440
29 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7322943
24 May 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7205429
11 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6624408
9 August 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6506549
10 April 2017
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6121442
21 July 2016
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5948487
9 March 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4813466
9 February 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4798890
13 December 2012
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4502823
21 April 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4404109
9 June 2011
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4043436
21 March 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3968404
7 November 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3887347
17 August 2010
Administration · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3826638
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
15 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363566
3 May 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3199298
20 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2911053
27 November 2006
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2829126
2 November 2006
MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2813278
22 September 2005
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2499337
22 January 2005
Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 2279088
16 November 2004
Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 2242461
8 October 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2216452
21 June 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2111867
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980542
30 July 2003
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1867177
6 February 2002
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1484321
21 October 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1482004
20 October 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1481981
28 August 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 293320
14 August 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 29134
27 March 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 83864
8 September 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 140782
15 July 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 431221
7 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 77916
22 June 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 10578
11 May 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 416345
30 December 1997
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 763695
20 December 1997
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 163281
20 December 1997
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 203095
8 December 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 130553
8 January 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 46987
31 October 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 695653
29 October 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 64752
26 October 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 384303
19 October 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 384036
3 October 1994
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 371108
8 June 1993
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 358803
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 January 2023
Resolved
Each Towing Vessel must have... high bilge alarms.. alarms must be visible and audible at each operating station.
The vessel did not have an audible bilge alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 13 February 2023
Resolution: witness visual and audible alarm at ops station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2023
Resolved
Each EAP education program must include at least the following elements: ... display and distribution of community service hot-line telephone number.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 January 2023
Resolved 23 January 2023
Resolution: An EAP poster was
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2023
Resolved
Machinery... systems must be designed and maintained to provide safe operation of the towing vessel.
There was a fuel leak on the STBD fuel-water separators.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2023
Resolved 23 January 2023
Resolution: The fuel leak was repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
Pressure vessel relief valves must be tested twice every 5 years, with no more than 3 years elapsing since the last test.
The relief valves were eight years old with no record of testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2023
Resolved 31 January 2023
Resolution: New relief valves were installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 January 2023
Resolved
An existing vessel may be deemed by the OCMI to be in compliance with this subpart provided that (b) it does not cause the structure of the vessel to be questioned by the OCMI.
The hatch gaskets on the water tight doors in the engine room have failed and caused the watertight integrity of
vessel to be questioned by the OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 13 February 2023
Resolution: Chalked tested watertight doors, new gaskets were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
Machinery must be designed and maintained to provide safe operation of the towing vessel and safety of persons onboard.
The MSD appeared to be leaking into the forward deck locker and it appeared to be held in place with a chain fall. Prove to the OCMI that that the MSD is fully operational and secured to the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 July 2023
Resolved 13 February 2023
Resolution: verified installation of new MSD.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 January 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
The vessel had broken windows on both sides of the engine room, repair the windows to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 31 January 2023
Resolution: The engine room windows were repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 January 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
There were no provisions for closing the ventilation intakes in the engine room. Make provisions to the satisfaction of the OCMI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 31 January 2023
Resolution: Closures were added to the engine room ventilation supply ducts.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 October 2021
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 50 PSI and a flow rate of at least 80 gpm.
The vessel's fire pump only produced 15 psi while delivering water to a single hydrant.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2021
Resolved 25 October 2021
Resolution: CG Inspector witnessed proper operation of water pressure from fire pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 October 2021
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the international regulations for preventions of collisions at sea or 33 CFR part 84 as appropriate to its area of operation.
The vessel's port running light was inoperative.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: The light bulb was replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) high bilge levels.
The vessel did not have a high bilge level alarm in the space with the fire pump through hull fitting.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2021
Resolved 25 October 2021
Resolution: Owner had two additional high level bilge alarms installed in the generator room and in the forward compartment, where the fire pump is installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2021
Resolved
Lifejackets must have the following attachments and fittings:(1) each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket.
The lifejacket on the bridge did not have a working lifejacket light.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: Battery was replaced in the lifejacket light. Op test was SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 October 2021
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either:... the vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI engaged on a survey.
The framing in the stern void had deterated to the point where it no longer added structural stiffness to the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2022
Resolved 10 November 2021
Resolution: Companty replaced frames in stern void.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 21 August 2021
Resolved 10 November 2021
Resolution: Vessel completed satisfactory COI inspection and COI routed for signature.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2002
Resolved
Labeling on fire detection control panel did not indicate location/origin of fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 June 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 February 2002
Resolved
Remote fuel shut off was lacking the purpose of the valve. LEGACY COMPONENT DESC: Labeling
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 June 2004
Operations/Management › Drills/Instruction › Fire
Issued 6 February 2002
Resolved
Vessel is not logging monthly fire drills that are conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 June 2004
Lifesaving
Issued 11 May 1998
Resolved
CG boarding officers recommended installation of machinery guards over exposed generator belts. Installation confirmed on follow up boarding 12 May 98.
Condition: Unknown
Due 12 May 1998
Resolved 24 May 1998
Documentation
Issued 26 October 1995
Resolved
TRANSFER PROCEDURES NOT AVAILABLE FOR INSPECTION
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Construction/Loadline
Issued 26 October 1995
Resolved
OFFICIAL NUMBER WAS NOT CLEARLY VISIBLE ON INTERIOR STRUCTURAL PART OF HULL.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995