Records from 2004 to 2025. Most recent: inspection, 4 December 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS, INC. · ASHLAND CITY, TN, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
5590 - Displacement, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
4 December 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8275636
10 September 2024
Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7999571
8 December 2023
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7836225
14 December 2022
Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7608948
9 July 2022
Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7503412
2 December 2021
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7361313
30 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7087190
17 March 2020
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6927887
5 March 2020
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6924452
5 September 2019
Internal Structural Exam · COI Inspection · Damage Survey · Examination of Repairs · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6804592
14 November 2018
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6580921
19 November 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6309648
9 November 2017
Deficiency Check · Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6299447
22 July 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5949431
26 September 2015
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5730404
24 August 2015
Deficiency Check · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5221021
13 August 2014
Administrative Inspection · Internal Structural Exam · MTSA Verification · COI Inspection · Deficiency Check · Cargo Tank Internal · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4953921
13 February 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4799851
8 November 2013
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4752706
30 October 2012
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4475151
13 February 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4243267
23 November 2011
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4190257
5 August 2010
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3815666
20 July 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3797221
29 June 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3780239
31 August 2009
Examination of Repairs · Internal Structural Exam · MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3581750
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
18 January 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396865
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335019
22 August 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3308675
20 October 2006
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2803241
31 October 2005
Periodic Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2525519
13 June 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2388920
16 February 2005
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2298338
6 August 2004
Deadweight Survey · Hull Examination · MTSA Verification · Initial Construction-Excluding Oversight · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2156724
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 November 2017
Resolved
Hose not stenciled with MAWP of 150.
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 13 November 2017
Resolution: Hose properly stenciled.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 November 2017
Resolved
Generator Switch Board has numerous holes in side of box. Make weather tight.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 14 November 2017
Resolution: Switchboard box has been permanently repaired.
Deck/Cargo › Cargo Heating › General
Issued 24 August 2015
Resolved
A small leak of thermal fluid was found in vicinity of cargo manifold. Thermal fluid system piping in vicinity of cargo manifold to be available for visual inspection and to ensure system is leak free.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2015
Resolution: Vessel rep removed insulation, tightened heater fluid system union, and made available for inspection. Upon exam, piping was found to be satisfactory.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 24 August 2015
Resolved
Prove proper operation of high level alarms required by 46 CFR 39.2009. At time of inspection, alarms and lights continuously actuated, making them inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2015
Resolution: Vessel operator repaired alarm system and proved proper operation to attending marine inspector.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 August 2015
Resolved
Exhaust piping in area accessible by vessel crew not insulated nor were guards installed as required by 46 CFR 58.01-20.
Action required: 705 - Other - as specified
Resolved 25 August 2015
Resolution: Insulation installed on exhaust piping and examined by inspector.
Engineering › Fuel Oil Service System › Hose
Issued 24 August 2015
Resolved
Non metalic piping (hose) used to supply fuel to diesel pump engine did not meet SAE J 1942 standard as required by 46 CFR 56.50-75/46CFR56.60.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 26 August 2015
Resolution: Cotton jacketed fuel lines were replaced with approved ones.
Engineering › Fuel Oil Service System › Piping
Issued 24 August 2015
Resolved
Prove proper repair of fuel oil system piping; at time of inspection fuel piping return line was found to be leaking in vicinity of thermal fluid heater.
Action required: 705 - Other - as specified
Resolved 25 August 2015
Resolution: Vessel rep disassembled and properly reassembled piping and then demonstrated satisfactory operation to marine inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 August 2015
Resolved
Hose (not in use nor connected to transfer system at time of inspection) not marked with maximum allowable working pressure as required by 33 CFR 155.800/33CFR154.500.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 26 August 2015
Resolution: Cargo hoses were properly stenciled with appropriate markings.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 August 2015
Resolved
One B-II fire exinguisher on vessel to meet COI requirement was last serviced in July of 2014 and not within last 12 months as required by 46CFR31.10-18.
Due 24 August 2015
Resolved 24 August 2015
Resolution: Fire extinguisher removed from vessel and an extinguisher that had been properly serviced was placed on board before the end of the inspection.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 24 August 2015
Resolved
Transfer procedures did not include cargo information. This requirement is typically satisfied by the vessel with the carriage of Material Safety Data Sheets (MSDS) for cargos currently being transported by the vessel. The current cargo was asphalt and there was no MSDS for asphalt on board the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: Vessel rep placed an MSDS for asphalt on board the vessel.
Construction/Loadline › Structures › Rake
Issued 30 October 2012
Resolved
Port bow rake top corner has approx 2' long x 1.5' wide x 6" deep inset due to incident in July 2012. Company to ensure welds and frames integrity have not been compromised internally.
Action required: 705 - Other - as specified
Due 19 November 2012
Resolved 2 November 2012
Resolution: Marine surveyor was hired to inspect internal rake to determine extent of damage. No. 1 Port bilge knuckle bracket bent and distorted. No broken welds or frames found. This damage will be permanently repaired in dry dock.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2012
Resolved
Thermal fluid heater piping missing section of insulation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2012
Resolved 2 November 2012
Resolution: New insulation and metal sheeting installed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2012
Resolved
Insulation missing on stbd tank 2 hot oil supply upper coil valve #H25, stbd tank 3 #H35 and port tank 3 #H29.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2012
Resolved 2 November 2012
Resolution: Insulation replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2012
Resolved
Approx amidship stbd electrical cable run for depth sounder found broken and wiring exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2012
Resolved 2 November 2012
Resolution: Cable run temporarily repaired with red hand. Permanent repairs to be completed in dry dock.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 20 July 2010
Resolved
Replace missing handle on #1 port spill valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2010
Resolved 5 August 2010
Resolution: Witnessed replaced handle on #1 port spill valve.
Construction/Loadline › Penetrations › Gasket
Issued 20 July 2010
Resolved
Replace #1 port void hatch cover gasket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2010
Resolved 5 August 2010
Resolution: Void hatch cover gasket repaired.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 20 July 2010
Resolved
Install alignment pin on forward VCS header port and starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2010
Resolved 5 August 2010
Resolution: Alignment pins re-established.
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2008
Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31 (l). Vessel operator given until 18JUN10 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. Magnolia Marine Transport compliance plan and D8 compliance plan approval letter have been scanned into vessel documents.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 5 September 2014
Resolution: Cargo pump engine was relocated outside the class 1 div1 hazardous explosive zone.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 February 2005
Resolved
When attending the therminol spill it was noticed, on a standard check, the Pilot had an expired radar endorsement.
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 31 October 2005
Resolution: This barge has no personel listed on it''s COI, therefore I cleared the def.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 6 August 2004
Resolved
The wiper shaft of the sight glasses on all of the expansion trunks failed the initial vapor tightness testing. Issued CG-835 that no "O" cargoes loaded until vapor system successfully passes vapor tightness testing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 August 2004
Resolution: Witnessed successful vapor tightness test at James Marine/Paducah River Service. Issued MSC Vapor Letter.