Records from 1990 to 2021. Most recent: inspection, 23 March 2021.
Inspection history · 50
23 March 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7161530
12 January 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7123999
25 October 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6568692
27 December 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6331633
8 June 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5901281
6 May 2016
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5884341
26 March 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5853713
6 June 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4881471
3 July 2013
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4642809
10 April 2013
MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4566275
7 April 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4796303
14 February 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4533778
11 July 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4077862
10 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4080931
11 April 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3984668
10 March 2011
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3961264
14 February 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3946367
26 August 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3835083
4 August 2010
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3820312
3 August 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3821942
8 October 2009
Administration · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3612214
6 August 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3558172
19 April 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3457350
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
16 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3372626
28 September 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368595
20 January 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3153111
24 August 2006
MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2758082
21 June 2006
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2687994
13 June 2006
Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2678265
27 May 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2386067
21 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2278833
14 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2278629
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978889
27 November 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 29659
20 March 2000
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 187359
8 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83168
3 September 1999
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510052
11 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 133144
16 April 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 22450
15 April 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 169918
16 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 161207
7 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 50454
22 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 22989
3 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 114010
14 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 665887
12 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 61192
12 May 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 231050
24 July 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 644405
12 January 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 334928
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 January 2021
No resolution recorded
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover and must be installed in the fuel piping directly outside of the fuel oil supply tank. The vessels remote fuel shutoffs were not located directly outside of the fuel oil supply rendering the shutoff's useless.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 January 2021
No resolution recorded
There must be an installed or portable bilge pump for emergency dewatering. Vessels crew could not prove proper operation of the installed emergency bilge pump.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 January 2021
No resolution recorded
The OCMI may require a review of a vessels watertight and weathertight integrity. During the course of the inspection it was noted there were multiple instances of questionable watertight integrity to include the port side shell in the engine room, the starboard side sideshell in the engine and a watertight bulkhead penetration in engine room aft above watertight door. A review shall be submitted to the OCMI in accordance with 46 CFR 144.330.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Documentation
Issued 12 January 1990
Resolved
46CFR 67.45-7(A) MISSING CERTIFICATES OF DOCUMENTATION
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 12 January 1990
Resolved
47CFR80.405(C) RADIOTELEPHONE STATION LICENCE OUTDATED 46CFR80.409(A) RADIO STATION LOG NOT MAINTAINED
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 12 January 1990
Resolved
46CFR25.25-5(D) NO SERVICEABLE CG APPROVE LIFE RING
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 12 January 1990
Resolved
46CFR67.15-1 OFFICAL NUMBER NOT MARKED ON INTERIOR OF HULL
Condition: Unknown
Due 12 February 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 12 January 1990
Resolved
46CFR25.30-20(B)(1) VESSEL HAS ONLY ONE OPERABLE BII FIRE EXTINGUISHER 46USC4102(A) EXTINGUISHERS NOT SERVICED
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 January 1990
Resolved
33CFR 155.410(A) NO MEANS OF DISCHARGING OILY MIXTURES
Condition: Unknown
Due 12 February 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 January 1990
Resolved
33CFR155.740(A) MISSING OIL TRANSFER PROCEDURES
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 January 1990
Resolved
33CFR 155.450(A)DISCHARG PLACARD NOT POSTED IN MACHINERY SPACE
Condition: Unknown
Due 12 January 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 12 January 1990
Resolved
33CFR 159.7 VESSEL NOT USEING MSD 33CFR 1322(B)(1) SEWAGE BEING PUMPED OVERBOARD
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 12 January 1990
Resolved
33CFR155.320(B) NO FIX CONTAINMENT UNDER OVER FLOW VENTS OR FUEL PIPES
Condition: Unknown
Due 12 February 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past