Documentation record
Registered dimensions (L × B × D)308.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,676 / net 1,676
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC. · MADISONVILLE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1676 - Simplified, Gross Ton
1676 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 41 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 22 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 41
19 March 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8328485
18 June 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8161802
18 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7914583
20 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7653890
7 February 2022
Examination of Repairs · Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7389170
28 October 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7346693
5 March 2021
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7150892
26 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6946360
18 March 2020
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6931153
11 March 2020
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6924417
9 January 2020
Damage Survey · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6885859
19 March 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645409
16 August 2018
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6511922
28 June 2018
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6458413
15 February 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6355440
26 January 2017
Drydock Exam · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6077479
12 April 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5852848
7 April 2016
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848940
24 February 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5070639
24 February 2015
Load Line/Change of Employment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5085515
2 May 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4851670
25 February 2014
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4805753
27 July 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4392102
25 March 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4272476
13 January 2012
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4223501
5 November 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4183608
21 October 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4173268
26 August 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3835083
4 August 2010
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3814590
3 August 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3821942
29 March 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3704772
28 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3707900
6 August 2009
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3558031
6 August 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3558172
5 February 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3412947
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
18 January 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396839
27 June 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3249385
26 February 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3153840
17 July 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2998064
9 January 2007
Cargo Tank Internal · COI Inspection · Initial Construction-Excluding Oversight · Administrative Inspection · MTSA Verification · Internal Structural Exam · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2852862
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 June 2024
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air).
Vessel Representative was unable to demonstrate an effective means to stop the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 19 March 2019
Resolved
Each item of remote operating or indicating equipment,such as emergency shutdown device must perform its intended function. The emergency shutdown on the STBD Black Oil cargo pump was inoperable at the time of inspection. Company representatives were able to correct the deficiency immediately.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 March 2019
Resolution: Vessel representative was able to rectify the deficiency
Documentation › Logs/Records › Oil Record Book
Issued 15 February 2018
Resolved
Each completed op shall be signed by PIC and each completed page shall be signed by the master. Completed pages are unsigned and blank pages are pre-signed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 16 February 2018
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 15 February 2018
Resolved
Hazardous location equipment must be approved as suitable for use in hazardous atmosphere. Electrical items in house in haz zone are not intrinsically safe.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 16 February 2018
Resolution: Corrected on the spot.
Deck/Cargo › Cargo Heating › General
Issued 15 February 2017
Resolved
Thermal Fluid Heater (TFH) to be examined by a MI at the COI to determine that the unit is in safe and satisfactory condition. Leaks observed at the on-deck isolation valve flanges. TFH to be tagged-out until gaskets are replaced and deck cleaned of residues.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 21 February 2017
Resolution: Received confirmation from rep that new gaskets were ordered and installed.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 15 February 2017
Resolved
A tank vessel must have a means of draining oil from enclosed deck area without discharging oil into the water. Oil residues from cargo tank cleaning were present on deck during COI. Oily residues shall be cleaned and disposed of IAW applicable pollution regs.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Vessel hired contractors to clean decks.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 March 2010
Resolved
Vessel only had a non-original copy of page 1 of the Certificate of Inspection. Vessel must have all pages of the original COI onboard before conducting any cargo operation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: Barge rep indicates COI has been lost and is not recoverable. Will issue new COI with periodic amendment.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 26 February 2008
Resolved
Vessel is required to repair and service all of shutdowns for the vessel's cargo pump engines prior to any cargo operations.
Action required: 705 - Other - as specified
Due 4 March 2008
Resolved 27 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2007
Resolved
Issued deficiency for not having an approved wiring harness that meets Class I, Div I requirements for use in hazardous areas. The current harness is going through the approval process.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 August 2007
Resolved 27 June 2008