Records from 2004 to 2025. Most recent: inspection, 4 December 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, KY, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 August 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
5590 - Displacement, Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
4 December 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8275647
3 September 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8226166
3 September 2024
COI Inspection · Cargo Tank Internal · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7995395
8 December 2023
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7836230
5 January 2023
Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7616735
8 December 2021
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7362358
30 October 2020
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7087195
1 October 2019
Examination of Repairs · Internal Structural Exam · MTSA Verification · COI Inspection · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6825399
7 September 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6806146
14 November 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6580928
15 November 2017
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6307309
2 November 2017
Deficiency Check · MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6299487
4 May 2017
Deficiency Check · In-Service Inspection · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6143787
21 April 2017
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6130227
21 April 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6137147
22 July 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5949463
24 August 2015
MTSA Verification · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5221038
20 August 2014
Internal Structural Exam · In-Service Inspection · COI Inspection · Examination of Repairs · Drydock Exam · Cargo Tank Internal · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4960362
13 February 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4799851
24 November 2013
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4758866
3 August 2013
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4732594
29 October 2012
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4477022
23 November 2011
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4190275
5 August 2010
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3815659
20 July 2010
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3800927
19 July 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3797248
29 June 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3780239
31 August 2009
Internal Structural Exam · MTSA Verification · Administrative Inspection · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3581752
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
18 January 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396884
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3335033
26 August 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3308552
22 August 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3308655
20 October 2006
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2803253
31 October 2005
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2525548
13 June 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2388924
20 August 2004
Hull Examination · Cargo Tank Internal · Initial Certification · MTSA Verification · Internal Structural Exam
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2170414
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 November 2017
Resolved
Hose not stenciled with MAWP of 150.
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 13 November 2017
Resolution: Hose properly stenciled.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 November 2017
Resolved
Generator Switch Board has two holes in back of box. Make weather tight.
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 13 November 2017
Resolution: Switch Board enclosure has been made weather tight.
Deck/Cargo › Cargo Heating › General
Issued 21 April 2017
Resolved
Repair replace thermal fluid heater prior to conducting cargo operations
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 19 May 2017
Resolution: Cropped and renewed Thermal Fuid Heater and all associated piping.
Deck/Cargo › Cargo Heating › General
Issued 21 April 2017
Resolved
Secure thermal fluid heater to deck during transit to Greenvill, MS.
Due 21 May 2017
Resolved 19 May 2017
Resolution: Cropped and renewed Thermal Fluid Heater and all associated piping.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 24 August 2015
Resolved
Closed gauging on vessel uses sight glasses to check tank levels. Product on sight glass prevented the ability to properly determine cargo level within cargo tanks as required by 46 CFR 39.2003.
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 8 September 2015
Resolution: Vessel rep had sight glass properly cleaned.
Deck/Cargo › Cargo Heating › General
Issued 24 August 2015
Resolved
A small leak of thermal fluid was found in vicinity of cargo manifold. Thermal fluid system piping in vicinity of cargo manifold to be available for visual inspection and to ensure system is leak free.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2015
Resolution: Leaking tracer line replaced and satisfactorily tested.
Engineering › Fuel Oil Service System › Hose
Issued 24 August 2015
Resolved
Non metalic piping (hose) used to supply fuel to diesel pump engine did not meet SAE J 1942 standard as required by 46 CFR 56.50-75/46CFR56.60.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 27 August 2015
Resolution: Vessel rep properly replaced fuel hose on diesel pump with approved hose.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 August 2015
Resolved
Hose (not in use nor connected to transfer system at time of inspection) not marked with maximum allowable working pressure as required by 33 CFR 155.800/33CFR154.500.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 26 August 2015
Resolution: Hose properly stenciled with appropriate markings.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 19 July 2010
Resolved
Properly repair indicator tab on the #2 cargo tank suction valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2010
Resolved 5 August 2010
Resolution: Replaced tab.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 19 July 2010
Resolved
Properly mark the MAWP on transfer hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2010
Resolved 5 August 2010
Resolution: Witnessed proper MAWP on hose (150 psi)
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2008
Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31 (l). Vessel operator given until 18JUN10 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. Magnolia Marine Transport compliance plan and D8 compliance plan approval letter have been scanned into vessel documents.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 15 September 2014
Resolution: Engine relocated outside the class 1 Div 1 hazardous zone.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 22 August 2008
Resolved
repair and prove proper operation of #1 stbd cargo tank high level alarm prior to loading next cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2008