Inspection history · 52
8 October 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8249292
26 February 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8085278
23 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7869208
1 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7630259
13 December 2021
Drydock Exam · Internal Structural Exam · Cargo Tank Internal · MTSA Verification · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7335790
13 January 2021
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7123888
11 March 2020
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6924419
7 January 2020
Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6885554
6 August 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6774398
20 February 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6628647
4 December 2018
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6591438
27 October 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6571120
5 April 2018
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6385994
13 December 2017
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6323581
28 November 2016
Drydock Exam · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048218
2 November 2016
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6049917
25 July 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5953684
31 March 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5844189
15 January 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5798280
6 January 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792076
4 June 2015
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5817334
15 March 2015
Load Line/Change of Employment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5085477
24 February 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5070634
19 December 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5068776
26 February 2014
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4806463
30 November 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4763450
8 August 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4690286
29 December 2011
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4215362
21 October 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4173268
18 November 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3893794
26 August 2010
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3834890
26 August 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3835083
3 August 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3821942
29 March 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3704899
28 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3707900
23 April 2009
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3458946
19 April 2009
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3456009
19 April 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3457350
9 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3416191
5 February 2009
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3412961
18 January 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396790
18 January 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3396863
27 June 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3249386
26 February 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3153773
20 January 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3153111
19 January 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3135726
19 September 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3061193
12 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3056039
31 August 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3043974
28 August 2007
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3041215
28 August 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3041866
18 December 2006
Administrative Inspection · COI Inspection · Hull Examination · MTSA Verification · Internal Structural Exam · Initial Construction-Excluding Oversight · Cargo Tank Internal · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2842377
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 January 2020
Resolved
High-level alarm and tank overfill alarm must be independent of each other and activate an alarm in the event of loss of power to the alarm system. The loss of power alarm was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 22 January 2020
Resolution: Received video of loss of power alarm with audio.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 December 2017
Resolved
The light on the ground detection is not operational on the 120V panel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2017
Resolved 14 December 2017
Resolution: Technician determined fault. Repaired accordingly. Ground detection on 120V panel is working as required.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 16 December 2016
Resolved
Electrical installations on vessels must ensure:(1)Maintenance of services necessary under normal & emergency conditions; (2) Protection of passengers, crew, other persons & the vessel from electrical hazards. Locate ground on vessel and repair to satisfaction of the attending CG Marine Inspector. 46 CFR 111.01-1 (a) (1) & (2)
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 23 December 2016
Resolution: Received documentation from electrician attesting that all grounds have been located and repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 March 2016
Resolved
Provide intrinsically safe battery box with proper connections
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Battery box has been moved to machinery space. All sat
Construction/Loadline › Hull › Hull Plating
Issued 26 August 2010
Resolved
Tank Barge BRYANT SEA was moored pier side at Cargo Dock No. 9 in the Corpus Christi inner harbor when it was struck by the bow of the KIRBY 30400/DAN L. The hull plating, just above the water-line, was punctured in the vicinity of the stern voids (6P & stern void). Vessels was issued a CG-835.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 September 2010
Resolved 30 August 2010
Resolution: Vessel underwent permanent repairs at Bludworth Shipyard in Corpus Christi, TX. (See Documentations/Certifications tab for pictures of the repairs.)
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2009
Resolved
Repair timberhead on port stern to satisfaction of OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2009
Resolution: SECT Houston inspector cleared def.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 26 February 2008
Resolved
Vessel is required to repair and service all of shutdowns for the vessel's cargo pump engines prior to any cargo operations.
Action required: 705 - Other - as specified
Due 4 March 2008
Resolved 27 June 2008
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 29 August 2007
Resolved
#2 Port side Prime Mover does not start, problem is unknown.
Action required: 705 - Other - as specified
Due 29 September 2007
Resolved 19 September 2007
Resolution: Engine starts, cleared deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 August 2007
Resolved
#6 port side (drop down) Cargo pipe valve suspect as cause of cargo release (oil spill) during cargo loading operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2007
Resolution: Received an fax of a successful air test performed on the valve located above tank top deck & two marine inspectors witnessed the pressure holding in pipe IWO valve.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 August 2007
Resolved
Emergency shutdown cable on #2 port side Prime Mover parted at engine shutdown device
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2007
Resolution: Emergency shutdown cable on #2 port side Prime Mover as been appropriately attached to prime mover and is functional.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 December 2006
Resolved
Wiring harness for the 3 cargo pump prime movers are not authorized for use within harzardous locations. Approval for the current harnesses or replacing the harnesses with an approved harness is required by 30 Aug 2007.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 August 2008
Resolved 27 June 2008