MM 97B is a 2013 tank barge. The Coast Guard has recorded 21 inspections since 2013, most recently in August 2026, along with 11 deficiencies and 1 casualty investigation in 2013.

Records from 2013 to 2026. Most recent: inspection, 18 August 2026.

Built
2013
Last inspected
18 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1228834
Flag
UNITED STATES
—
Maury page id
psix-1228834

Inspections, by type

…with no type recorded4
Years with a record 14 calendar years (2013–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC PLANT 38 · MADISONVILLE, LA, UNITED STATES · built 2013
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 8

Inspection history · 21

18 August 2026 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8467222
8 October 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8249352
25 September 2025 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8240905
12 September 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7999643
20 July 2023 MTSA Verification · Cargo Tank Internal · Hull Examination · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7744524
9 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7555138
6 August 2021 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7277778
19 August 2020 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7037109
25 September 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6820126
21 June 2018 Damage Survey · COI Inspection · Examination of Repairs · MTSA Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6451456
24 July 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6219045
10 July 2017 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6204289
3 October 2016 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6016567
17 June 2016 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5910462
24 July 2015 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5194767
24 February 2015 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5074464
24 February 2015 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5109925
7 February 2015 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5065744
12 August 2014 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4953982
3 August 2013 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4732594
10 June 2013 Initial Certification · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Deadweight Survey · Hull Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4652856

Deficiency record · 11

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 September 2025 Resolved
All flame screens are clogged with cargo over 50%. Clean all flame screens on restricted gauging.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 September 2025
Resolved 25 September 2025
Resolution: ITV crew cleaned all flame screens.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 September 2025 Resolved
Renew closed gauging glass on No 3. and No. 4 port cargo tank. Glass was found fractured on No. 3 and cracked on No. 4.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 17 October 2025
Resolution: glass repaired
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 September 2025 Resolved
Clean or replace all stick gauges. Gauges fouled with cargo and cannot be read.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 17 October 2025
Resolution: gauges sticks replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 September 2025 Resolved
Vessel had 9 wing void hatches dryrotted and splitting. Renew all hatches marked with a white X on the cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2025
Resolved 17 October 2025
Resolution: gaskets replaced
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 September 2025 Resolved
Prove proper operation of all high level/overfill alarms prior to carrying cargo requiring use of the VCS or 14 days which ever comes first.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 17 October 2025
Resolution: high level alarms tested sat
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 9 September 2022 Resolved
Tank barges that load cargoes that require vapor collection shall have an intrinsically safe high level alarm. The barges high level alarms are inoperable. Repair prior to loading cargoes that require vapor collection.
Action required: 705 - Other - as specified
Resolved 26 September 2022
Resolution: High level alarms were repaired and are operable.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 9 September 2022 Resolved
Each vapor collection flange face must have a permanent stud projecting outward at least 1 inch long located at the top of the flange. The port side vapor collection flange stud weld broke and it is pushed in and no longer 1 inch long. Repair prior to loading cargo that requires vapor collection.
Action required: 705 - Other - as specified
Resolved 26 September 2022
Resolution: The vapor collection flange stud was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 September 2019 Resolved
Warning sign at gangway was heavily faded and not was not able to read clearly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 25 September 2019
Resolution: Company replaced sign on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2019 Resolved
Emergency shutdown on the prime mover for the cargo pump did not shut completely down while testing the emergency stop. A valve to shut off the air flow did not close completely. - corrected on the spot
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Valve was replaced and deficiency was corrected on the spot during the annual inspection
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 10 July 2017 Resolved
HIGH LEVEL/OVERFILL ALARM NOT FUNCTIONING PROPERLY. PROVE PROPER OPERATION WITHIN 45 DAYS OR PRIOR TO LOADING O CARGOES WHICHEVER COMES FIRST.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 24 July 2017
Resolution: Replaces all alarm sensors and associated wiring.
Engineering › Fuel Oil Service System › Ventilation
Issued 17 June 2016 Resolved
PV Valves on the port and starboard above deck service tanks dismantled.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 17 June 2016
Resolution: Replaced with goose neck style vent with flame screen.

Casualty record · 1

3 August 2013Routine · role: Involved in a Marine Casualty · activity 4732594
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.