Records from 2007 to 2023. Most recent: inspection, 2 October 2023.
Documentation record
Registered dimensions (L × B × D)105.6 ft × 32.0 ft × 10.3 ft
Registered tonnagegross 444 / net 133
ITC dimensions (L × B × D)105.6 ft × 32.0 ft × 10.3 ft
ITC tonnagegross 444 / net 133
BuilderNICHOLS BOAT COMPANY · GREENVILLE, MS, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it444 - Convention (Subpart B), Gross Ton
133 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
2 October 2023
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7799359
4 March 2020
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6920619
19 February 2020
Deficiency Check · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6912212
19 February 2020
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6915223
26 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6896397
28 June 2019
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7148828
16 November 2018
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6581872
3 October 2018
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6554606
27 June 2017
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6189733
14 December 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6057919
3 October 2016
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6016567
16 July 2013
DAPI Audit · MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4655958
5 November 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4478963
7 September 2012
Administration
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4434681
10 May 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4311277
22 December 2011
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4213242
19 October 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4172236
26 July 2010
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3806278
18 May 2010
Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3741825
23 January 2010
Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 3668651
12 December 2009
Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 3668631
6 August 2009
MTSA Verification · Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3557356
10 June 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3584294
27 February 2009
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3427495
14 December 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3379964
19 October 2008
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3415303
3 June 2008
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3229973
14 March 2008
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3165906
19 December 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3119312
19 December 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3119440
26 April 2007
MTSA Verification
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2916541
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 October 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Alarm setpoints: Twice every 5 years, with no more than 3 years elapsing since last test. Vessel could not provide any documentation of required tests for all machinery. Vessel will provide a third party report with completion of required tests.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 10 October 2023
Resolution: Recieved report from TVIB accepting all deficiencies. Added report to documents.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 2 October 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must: be visible and audible at each operating station. Vessels bilge alarms do not have visual or audible indication on the bridge. Vessels engineering alarms have no audible indications on the bridge. Vessel will ensure all engineering alarms have a audible and visual indicators to meet the requiments of 46CFR143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2023
Resolved 10 October 2023
Resolution: Received report from TVIB accepting all deficiencies. Added report to documents.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine Inspectors found excessive rust scaling and debris in both the port and starboard engine room alleyway bilges which would inhibit the proper operation of the fixed bilge suction lines. Remove the excessive rust scale and debris from the bilges of both compartments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2023
Resolved 10 October 2023
Resolution: Recieved report from TVIB accepting all deficiencies. Added report to documents.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 February 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Make proper repairs to the grey water pipe located inside the STBD side #06 fuel tank to the satisfaction of the CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2020
Resolution: Cleared to the satifaction fo the CG marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 26 January 2020
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Due to marine casualty, vessel incurred the following damage: 1. Port side bulwark: commencing at the port no.5 fwd fuel tank bulkhead and extending aft for 15' the bulwark set in ~6" x height. 2. Port side 02 Handrail: commencing at the port aft end and extending fwd for 12' the triple pipe handrail is set in ~3'" for height. 3. stbd side bulwark: stbd stern corner extending inboard for 18" and fwd for 8'6", the port bulwark is set in ~8" x height. Repairs to be made to original design. TPO, TVIB, to provide oversight of repairs and provide report of satisfactory completion to Coast Guard.
46CFR144.800
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 4 March 2020
Resolution: Satisfactory repairs were made to the handrails and bulwarks P&S. Repair report was provided by the TPO and scanned into MISLE docs.