Records from 2003 to 2023. Most recent: inspection, 5 September 2023.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2003
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
5 September 2023
Internal Structural Exam · MTSA Verification · Drydock Exam · COI Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7770909
30 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7103650
16 September 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6812858
23 August 2018
Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6518154
31 October 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6298547
25 October 2016
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6020885
15 October 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5741916
23 October 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5011025
12 February 2014
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4799207
3 November 2013
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4747165
2 July 2013
MTSA Verification · Drydock Exam · Examination of Repairs · COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4631198
27 November 2012
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4491112
12 March 2012
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4266647
19 October 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4172236
20 June 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4054507
16 February 2011
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3945835
11 January 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3924485
11 January 2011
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3932859
28 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3859058
17 December 2009
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3652341
9 March 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3430459
18 December 2008
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3382107
21 February 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3149597
15 March 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2888462
24 March 2006
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2608277
15 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2407718
10 February 2005
MTSA Verification · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2289890
17 March 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2026163
24 December 2003
Initial Certification · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1969162
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2016
Resolved
Barge cargo engine supply and return hose ends heavily corroded. Replace hoses to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 27 October 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 October 2016
Resolved
Forward fire extinguisher bracket wasted with broken hold down strap. Replace bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 27 October 2016
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 29 November 2012
Resolved
Noted #3 Port and Stbd and #2 Stbd power wires for the High Level/Overfill Alarms were pulled out exposing internal conductors. Req issued to make wires water/Vapor tight.
Due 29 November 2012
Resolved 30 November 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 November 2012
Resolved
Re-attach hand rail portside fwd, and re-install fwd ladder or remove and replace with new hand rail section.
Due 29 November 2012
Resolved 30 November 2012
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 29 November 2012
Resolved
Prove the proper operation of the Cargo Pump engine emergency shutdown.
Action required: 705 - Other - as specified
Due 29 November 2012
Resolved 30 November 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 16 February 2011
Resolved
Repair and remount emergency shutdown cable on engine. 46 CFR 32.50-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 21 March 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 February 2011
Resolved
Repair mounting bracket for fire extinguisher. 46 CFR 34.50-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 21 March 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 February 2011
Resolved
Repair and retest crossover header for cargo pipeline.
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 21 March 2011
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 16 February 2011
Resolved
Repair valve indicator on cargo tanks 3 starboard and 1 port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 21 March 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 March 2006
Resolved
Provide proof of annual pressure test and mark the hose with the type of service and maximum allowable working pressure.
Action required: 705 - Other - as specified
Due 24 April 2006
Resolved 24 April 2006
Resolution: Test records provided and hose marked satisfactorily.