Records from 2005 to 2026. Most recent: inspection, 8 April 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
5590 - Displacement, Net Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
8 April 2026
MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8344761
13 January 2025
Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8058808
22 February 2024
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7867458
13 March 2023
Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7649103
2 December 2021
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7361309
28 January 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7132363
19 November 2019
Damage Survey · Internal Structural Exam · Drydock Exam · Cargo Tank Internal · MTSA Verification · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6858231
4 February 2019
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6618223
29 September 2017
In-Service Inspection · Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6277909
4 November 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6035288
10 September 2015
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5733618
26 February 2015
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5075889
18 February 2015
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5074476
15 February 2015
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5075258
14 November 2014
Deficiency Check · Examination of Repairs · Administrative Inspection · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5023815
19 August 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4959518
23 May 2014
Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4878443
23 May 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4900162
17 October 2013
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4736528
10 May 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4311277
13 January 2012
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4225928
22 December 2011
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4213242
5 November 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3889782
25 January 2010
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3669277
26 May 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3535430
20 January 2009
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3396883
12 January 2009
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3393181
12 January 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3393310
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3334988
30 May 2008
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3222258
5 October 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2794886
15 August 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3070556
3 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2598546
8 July 2005
Initial Certification · Internal Structural Exam · MTSA Verification · COI Inspection · Cargo Tank Internal · Construction Oversight · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2400600
13 June 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2388915
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 March 2023
Resolved
Cargo hose (not in use) required to be labled with MAWP. Hose not labled with MAWP. Correct prior to using hose for a regulated marine transfer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2023
Resolution: Vessel rep provided ojbective evidence of hose properly labeled with MAWP.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 13 March 2023
Resolved
Cargo hose (not in use) required to be annual tested. Hose not tested (according to available record) over one year. Correct prior to using hose for a regulated marine transfer.
Action required: 705 - Other - as specified
Resolved 14 March 2023
Resolution: Vessel rep provided copy of record showing hoses was properly tested on 10 Jan 2023.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 18 February 2015
Resolved
The cargo pump drive shaft coupling sheared all eight bolts during transfer. The vessel's crew made temporary repairs but were unable to fully extract two of the old bolts. As a result, the coupling is missing one bolt and one is only partially seated. Vessel is to make permanent repairs prior to discharge of cargo at next port.
Action required: 705 - Other - as specified
Due 18 March 2015
Resolved 26 February 2015
Resolution: The 2 broken bolts were extracted and replaced with new.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 February 2015
Resolved
The cargo pump drive shaft coupling sheared. As a result the mounted safety guard was damaged. Vessel is to make permanent repairs prior to discharge of cargo at next port.
Action required: 705 - Other - as specified
Due 18 March 2015
Resolved 26 February 2015
Resolution: Machinery guard replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 12 January 2009
Resolved
CFR Regulation: 46CFR30.01-10
Perform alterations or repairs in accordance with the regulations or under the direction of the OCMI.
Prior to setting sail to the satisfaction of a CG Marine Inspector/OCMI
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2009
Resolved 20 January 2009
Resolution: Air/soap tested repairs. Test sat.
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2008
Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31 (l). Vessel operator given until 18JUN10 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. Magnolia Marine Transport compliance plan and D8 compliance plan approval letter have been scanned into vessel documents.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 5 November 2010
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 8 July 2005
Resolved
Open gauging provided. Request amendment to 46 Subchapter "O" Cargo Authority Attachment (CAA) to reflect the open gauging installed or install closed gauging as depicted in approved drawings. Vessel is prohibited from carriage of all Subchapter "O" cargoes requiring restricted or closed gauging, until CAA amended or appropriate gauging installed to satisfaction of attending CG MI.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 August 2005
Resolution: CAA amended, per MSC ltr C2-0505376 dtd August 8, 2005.