Records from 2005 to 2025. Most recent: inspection, 6 October 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2005
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
5590 - Displacement, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
6 October 2025
Internal Structural Exam · Drydock Exam · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8246029
28 February 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8086109
22 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8065638
25 September 2023
Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796475
20 September 2023
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796025
15 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7636266
15 December 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7368422
28 October 2020
Administrative Inspection · COI Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7085824
23 July 2019
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6759296
17 September 2018
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6542255
29 September 2017
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6277914
25 May 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5886787
3 August 2015
In-Service Inspection · MTSA Verification · Drydock Exam · Examination of Repairs · Administrative Inspection · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5205619
9 July 2015
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5177465
26 May 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5135771
22 May 2015
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5132087
19 May 2015
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5130424
13 May 2015
Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5125935
12 May 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5129293
18 June 2014
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4892488
23 May 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4900162
17 October 2013
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4736532
15 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4654250
18 May 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4314798
7 June 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4039270
12 July 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3796045
7 July 2010
Examination of Repairs · Deficiency Check · Administrative Inspection · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3797241
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3334994
30 May 2008
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3222265
10 October 2007
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3076762
5 October 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2794893
1 June 2006
Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2668144
1 June 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2668478
20 July 2005
MTSA Verification · Hull Examination · Cargo Tank Internal · Internal Structural Exam · Initial Certification · Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2400607
13 June 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2388917
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2023
Resolved
Electrical equipment must function at variations of at least ±5 percent of rated frequency. It was noted that the generator hertz meter read 55Hz while rated for 60Hz. Prove proper operation of generator within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2023
Resolved 18 October 2023
Construction/Loadline › Hull › Side Shell
Issued 19 May 2015
Resolved
Clean residual asphalt oil from decks and side of barge prior to any further cargo operations.
Action required: 705 - Other - as specified
Resolved 22 May 2015
Resolution: Cleaned to the satisfaction of attending Marine Inspector.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 15 May 2015
Resolved
Replace all pressure vacume valves on all cargo tanks prior to operating TFH and departure from MM769 Ohion River.
Action required: 705 - Other - as specified
Resolved 15 May 2015
Resolution: MI observed new P/V valves were installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 May 2015
Resolved
Vsl shall proceed one time, one way from MM769 Ohio River to Paduka KY cleaning facility. Make cargo pump availble for inspection. Prior to departure from Puduka KY.
Action required: 705 - Other - as specified
Resolved 19 May 2015
Resolution: Puduka Marine Inspector witnessed running of cargo pump after packing was replaced.
Electrical › Electric Supply System (service) › Cable
Issued 29 September 2008
Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31 (l). Vessel operator given until 18JUN10 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. Magnolia Marine Transport compliance plan and D8 compliance plan approval letter have been scanned into vessel documents.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 19 August 2010
Resolution: Company moved engine outside of the Class 1/ Div 1 area.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 20 July 2005
Resolved
Open gauging provided. Request amendment to 46 Subchapter "O" Cargo Authority Attachment (CAA) to reflect the open gauging installed or install closed gauging as depicted in approved drawings. Vessel is prohibited from carriage of all Subchapter "O" cargoes requiring restricted or closed gauging, until CAA amended or appropriate gauging installed to satisfaction of attending CG MI.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 August 2005
Resolution: CAA amended, per MSC ltr # C2-0505376, dtd August 8, 2005.