Records from 2007 to 2026. Most recent: inspection, 16 July 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
16 July 2026
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8437947
29 October 2025
Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8259453
18 November 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8033490
13 October 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796477
20 September 2023
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7796025
8 September 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7566560
15 August 2022
Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7531535
27 July 2021
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7271516
24 July 2020
Periodic Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7015317
7 August 2019
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6775042
10 March 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6640111
1 August 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6498768
26 September 2017
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6275100
29 June 2017
MTSA Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Administrative Inspection · Drydock Exam · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6190609
18 October 2016
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6025062
4 May 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5868895
29 June 2015
Deficiency Check · Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5168009
10 September 2014
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4979837
2 July 2012
MTSA Verification · COI Inspection · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4365030
5 August 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4104119
17 September 2010
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3853529
3 September 2010
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3848940
19 August 2010
Damage Survey · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3825960
3 June 2009
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3494299
29 September 2008
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3334949
23 June 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3246339
21 June 2007
Initial Certification · MTSA Verification · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2968852
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2019
Resolved
One of three required portable fire extinguisher on board had gauge which showed pressure out of acceptable range. Extinguisher required to be replaced.
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: Defective extinguisher removed from service and replaced with an acceptable extinguisher.
Deck/Cargo › Cargo Heating › General
Issued 29 June 2015
Resolved
Prove proper operation of thermal fluid heater and generator prior to transporting elevated temperature "E" cargos.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2015
Resolution: Witnessed proper operation of thermal fluid heater and generator.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 September 2010
Resolved
Provide local OCMI with repair proposal and make proper permanent repairs to damage iwo the #5 and #6 wing voids.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 18 September 2010
Resolution: Air test and welds sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 19 August 2010
Resolved
EQUATE 4" PV drain plug screens require cleaning. Screens clogged with oil/asphalt product.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2010
Resolved 17 September 2010
Resolution: Examined screens all sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 August 2010
Resolved
Make available for visual inspection the #5 and #6 wingtanks to determine extent of damage to transverse bulkhead at deck/sideshell interface.
Action required: 705 - Other - as specified
Due 3 September 2010
Resolved 3 September 2010
Resolution: Company made vessel available for inspection. Issued new CG-835 for damage to transverse bulkhead between the #5 and #6 port wing void.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 21 June 2007
Resolved
Provide proof of cargo pump engine wiring harness and alternator meeting 46 CFR 111.105-31(l) N.E.C. Class 1/Division 1 as per USCG D8(m) policy letter 02-2005.
Action required: 705 - Other - as specified
Due 18 June 2010
Resolved 19 July 2012
Resolution: Relocated engine outside hazardous zone.