Records from 1991 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 86
13 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8344233
12 November 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8267914
12 June 2025
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8158461
17 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8021194
4 June 2024
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7927040
27 March 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7885955
4 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7662488
11 March 2022
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Drydock Exam · Damage Survey · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7410133
29 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7185637
22 April 2020
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6942360
17 May 2019
MTSA Verification · Damage Survey · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6686469
11 June 2018
Examination of Repairs · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6441270
10 April 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388947
24 February 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6363550
19 May 2017
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6189998
17 April 2017
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6148657
10 February 2017
Administrative Inspection · COI Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6086005
26 February 2016
Examination of Repairs · Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5821169
15 May 2015
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5128982
5 November 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5018308
26 September 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5018255
26 June 2014
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4900440
28 April 2014
Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4845723
12 December 2011
Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4206628
15 June 2011
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4045498
7 November 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3887347
12 October 2010
Administrative Inspection · COI Inspection · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3869971
18 February 2010
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3682322
31 July 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3551430
27 October 2008
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3352314
30 January 2008
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3140164
4 January 2007
Examination of Repairs · Internal Structural Exam · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2850222
18 April 2006
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2627449
18 April 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2633005
14 November 2005
COI Inspection · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2528852
14 March 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2307602
24 February 2005
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2297771
2 November 2004
Damage Survey · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2233372
1 November 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2243627
1 April 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2035289
29 March 2004
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2033501
23 March 2004
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2029857
17 March 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2029163
20 February 2004
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2010092
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997375
25 November 2003
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1954374
4 April 2003
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1768272
27 February 2003
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1750525
1 March 2002
Periodic Inspection · Examination of Repairs · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1490722
29 November 2000
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1386921
5 March 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 496260
11 January 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458706
11 December 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 482748
10 June 1999
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 808659
24 January 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 529238
3 December 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470484
21 June 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 516049
16 January 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404501
13 January 1998
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 452982
8 January 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 768868
17 August 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 534134
3 January 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 190526
17 December 1996
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1434495
8 December 1995
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1185684
15 November 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434324
18 February 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 21807
10 January 1995
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1170823
21 November 1994
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 133973
21 November 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170979
5 October 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 462442
18 September 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 491501
11 September 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 483324
13 August 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 436798
16 December 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159274
1 December 1993
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 530053
1 December 1993
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 852529
17 October 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 450600
1 February 1993
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 831047
25 July 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 530043
14 July 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 665632
5 May 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 34313
5 May 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 449900
5 May 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 501418
19 December 1991
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 447186
18 December 1991
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1266219
6 December 1991
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 940038
Deck/Cargo › Cargo Heating › General
Issued 23 April 2018
Resolved
A small area of burnt paint was identified on the end of the thermal fluid heater nearest the conterol panel. Vessel rep stated that the area would be inspected and a report of findings would be provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 18 June 2018
Resolution: TFH was inspected and found to have a faulty section of insulation, technican repaired insulation.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 3 March 2016
Resolved
On 2 cargo tanks (no. 4 port and starboard) overfill devices(required by 33 CFR 155.480/46 CFR 39.2003(b)) were improperly installed. Installation rendered devices inoperable; standard ERL devices installed on oversized base flanges (approximately 40 inches). Vessel required to be brought into compliance with 33 CFR 155.480 to the satisfaction of the attending CG marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2016
Resolved 4 March 2016
Resolution: Bases supporting devices shortened to a hieght that would support proper operation of ERL standard high level indicating device (approximately 6 inches).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 26 February 2016
Resolved
Vessel improperly marked with two Maximum Allowable Working Pressures; required removal of one to be in compliance with 33 CFR 155.800/33 CFR 154.500/46 CFR 32.50-30.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 26 February 2016
Resolution: Incorrect MAWP rendered unreadable.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 26 February 2016
Resolved
When energizing high level alarm system, visual and audio alarms activated continuously rendering alarm system inoperable. Prior to using vapor control system during a cargo load, vessel representative must demonstrate properly operating high level alarm system.
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 4 March 2016
Resolution: Witnessed proper operation of high level alarm system.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 February 2016
Resolved
Switchboard located on weather deck used in thermal fluid heater system had several 1/8 inch holes and one 1 inch hole in the box compromising container's construction integrity. Construction integrity required to be maintained IAW 46 CFR 111.01-1. Integrity of container to be restored prior to using equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Holes mechanically secured; restoring box integrity.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 12 December 2011
Resolved
Vapor recovery system not approved bt MSC; vapor lines not authorized for use prior to receipt of approval from MSC.
Action required: 705 - Other - as specified
Resolved 17 April 2012
Deck/Cargo › Cargo Heating › General
Issued 24 February 2005
Resolved
Repair or replace sight glass on thermal fluid heater.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 14 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2005
Resolved
Place lagging on thermal line on #1 cargo tank.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 14 March 2005
Electrical › Electric Generation Source (service) › Ground Detection
Issued 24 February 2005
Resolved
Place ground detection on generator panel IAW 46 111.05-21
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 14 March 2005
Deck/Cargo › Holds/Tanks
Issued 17 March 2004
Resolved
Pinhole leaks were discovered on the weld seam on # 2 stbd cargo tank in way of external frames 6 and 7 at themain deck and tank trunk. Pinhole leaks were discovered on weld seam on # 3 stbd cargo tank in way of external frame 2 at the main deck and tank trunk.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2004
Resolution: Repairs to the #2 and #3 starboard cargo tanks were completed by Mississippi Marine Corp. Air soap test was sat.
Construction/Loadline › Hull
Issued 4 April 2003
Resolved
Make barge available for damage survey upon it's return to the port of St. Louis. This is required due to a grounding at Mile
106 of the Missouri River. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Due 4 May 2003
Resolved 25 November 2003
Deck/Cargo › Cargo Stowage › General
Issued 27 February 2003
Resolved
Install proper length rising sticks on #4 port and starboard cargo tanks to compensate for riser. LEGACY COMPONENT DESC: Rising sticks
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 14 November 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Deck/Cargo
Issued 27 February 2003
Resolved
Show proper operation of #1, #2, and #3 port rising sticks. LEGACY COMPONENT DESC: Rising sticks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 17 April 2003
Construction/Loadline › Structures
Issued 27 February 2003
Resolved
Install Brake pad on aft port cable winch brake.
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 18 April 2003
Construction/Loadline › Structures
Issued 27 February 2003
Resolved
Replace hatch gaskets on forward port and #4 starboard forward hatch. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 18 April 2003
Deck/Cargo
Issued 15 November 1995
Resolved
REMOVE ACCESS PANEL IWO THERMAL FLUID HEATER TO ALLOW CG INTERNAL VISUAL EXAM.(IAW 46 CFR 61.30-5 a,b AND 61.30-15).
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
RENEW CRACKED WELDS LOCATED IN UNION BETWEEN TRANSVERSE AND VERTICAL FRAMESABOVE CARGO TANK TRUNKS AT THE FOLLOWING FRAMES (COUNTING FROM FWD AFT: PORT 1-30, STBD 1-30)
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
RENEW WELDMENT IN WAY OF AFT OUTBOARD CORNERS OF #4 PORT AND STBD CARGO TANKS AT UNION OF WEATHER DECKING AND MAIN DECK.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
RENEW CRACKED SEAMS (RUNNING LONGITUDINALLY) ON MAIN DECK AT CARGO TANK TRUNKS AT THE FOLLOWING LOCATIONS: ADJACENT TO #3 PORT FWD BUTTERWORTH HATCH.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
REPAIR 2" HOLE IN MAIN DECK IWO FIRST SEAM STBD OF CENTER LINE SEAM 10" AFTOF BOW.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
PICK-UP BROKEN INTERMITTEN WELDS ON WEATHER DECK TRUNK (STBD AND AFT).
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Accommodation/Occupational Safety
Issued 15 November 1995
Resolved
REATTACHED DISCONNECTED CAT WALK EXPANDED METAL AT #2 CARGO TANK.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 15 November 1995
Resolved
RENEW HULL MARKINGS IWO VESSEL NAME ON BOW.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 1 December 1993
Resolved
OPEN ALL PV VALVES FOR INSPECTION. NO CARGO OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Deck/Cargo
Issued 1 December 1993
Resolved
MAKE PERMANENT REPAIR TO FRACTURES IN #2 PORT AND STBD CARGO TANKS, AT ABOUT AMIDSHIP, AT BOTTOM OF RAISED CARGO TANK TRUNK AT DECK. NO CARGO OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 1 December 1993
Resolved
MAKE PERMANENT REPAIR TO NUMEROUS FRACTURED WELDS ON CARGO TANK RAISED TRUNK VERTICAL EXTERNAL FRAMES. NO CARGO OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 1 December 1993
Resolved
MAKE PERMANENT REPAIR TO NUMEROUS FRACTURED WELDS ON CARGO TANK EXTERNAL TRANSVERSE FRAMES ON CENTERLINE OF TANKS. NO CARGO OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 1 December 1993
Resolved
MAKE PERMANENT REPAIR TO FRACTURES ON PORT AND STBD AFT CORNERS OF RAISED CARGO TANK TRUNKS. NO CARGO OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Construction/Loadline
Issued 6 December 1991
Resolved
PROVIDE EVIDENCE TO COMPLY WITH ITEM 3 OF MSC-3 PLAN REVIEW COMMENT LETTER OF 05NOV91, SERIAL C-10398, NO LATER THAN 20 DECEMBER 1991.
Condition: Unknown
Due 20 December 1991
Resolved 6 February 1992
Deck/Cargo
Issued 6 December 1991
Resolved
MAXIMUM SPECIFIC GRAVITY OF CARGO CARRIED IN THE INTEGRAL GRAVITY CARGO TANKS MUST NOT EXCEED 1.05 (8.7 LB/GAL).
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Deck/Cargo
Issued 6 December 1991
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP AND CARGO ENGINE, INCLUDING EMERGENCY SHUTDOWN FOR CARGO PUMP ENGINE AND LIFTING OF CARGO PUMP DISCHARGE RELIEF VALVE AT 125 PSI, PRIOR TO ANY CARGO OPERATIONS AND NO LATER THAT 06JAN92.
Condition: Unknown
Due 6 January 1992
Resolved 6 February 1992
Construction/Loadline
Issued 6 December 1991
Resolved
BARGE MAXIMUM DRAFT IS LIMITED TO 10'-6" ON RIVERS ROUTE AND MAXIMUM DRAFT OF 10'-6" ON LAKES, BAYS AND SOUNDS.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Documentation
Issued 6 December 1991
Resolved
SUBMIT FINALIZED STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY _x001C_ CENTER (MSC-3) NO LATER THAN 20 DECEMBER 1991.
Condition: Unknown
Due 6 January 1992
Resolved 6 February 1992
Documentation
Issued 6 December 1991
Resolved
PLACE COPY OF CERTIFICATE OF FINANCIAL RESPONSIBILITY ON BOARD PRIOR TO ANYCARGO OPERATIONS AND NO LATER THAN 06JAN92.
Condition: Unknown
Due 6 January 1992
Resolved 6 February 1992
Electrical
Issued 6 December 1991
Resolved
CONDUCT TEST OF GENERATOR EMERGENCY SHUTDOWN PRIOR TO ANY OPERATION OF THE GENERATOR, AND NO LATER THAN 06JAN92.
Condition: Unknown
Due 6 January 1992
Resolved 6 February 1992
Deck/Cargo
Issued 6 December 1991
Resolved
MAXIMUM SPECIFIC GRAVITY OF THE LIQUID CARRIED IN THE DECK TANKS MUST NOT EXCEED 0.85 (7.1 LBS/GAL).
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992