MM 95

MM 95 is a 2013 tank barge. The Coast Guard has recorded 21 inspections since 2014, most recently in July 2026, along with 6 deficiencies and 3 casualty investigations between 2014 and 2022.

Records from 2014 to 2026. Most recent: inspection, 31 July 2026.

Built
2013
Last inspected
31 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 31 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2014–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1203337
Flag
UNITED STATES
Maury page id
psix-1203337

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · MADISONVILLE, LA, UNITED STATES · built 2013
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 21

31 July 2026 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8450392
21 August 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8210580
16 September 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8001426
23 June 2023 Internal Structural Exam · Initial Certification · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7720912
9 July 2022 Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7503415
9 July 2022 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7577570
16 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7479138
9 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7221699
19 August 2020 Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7037070
14 August 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6784269
14 January 2019 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6611150
31 May 2018 Internal Structural Exam · COI Inspection · Administrative Inspection · MTSA Verification · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6429983
24 August 2017 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6250528
2 August 2016 Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5961228
15 June 2016 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5908351
15 January 2016 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5799482
15 January 2016 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5808156
16 September 2015 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5720768
8 June 2015 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5148679
30 July 2014 Annual Inspection · Administrative Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4939102
9 March 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4813466

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 June 2022 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. The Vapor Line stud on the port side vapor connection flange face is missing. Rectify the deficiency prior to carriage of cargos requiring the vapor control system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 24 June 2022
Resolution: The vapor line stud was repaird to the satisfaction of the OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 August 2020 Resolved
Starboard cargo pump exhaust elbow has thin crack. Repair/replace cracked exhaust elbow and apply insulation to satisfaction of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 28 August 2020
Resolution: Exhaust elbow has been repaired to satisfaction of Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2020 Resolved
Replace missing battery box cover for vessel generator to satisfaction of Marine Inspector. 46 CFR 32.45-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 28 August 2020
Resolution: Battery cover replaced to satisfaction of Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 August 2020 Resolved
Vessel nav light posts need flat black paint re-applied to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 28 August 2020
Resolution: Nav light posts are black to satisfaction of Marine Inspector.
Electrical › Electric Generation Source (emergency) › Switch
Issued 30 July 2014 Resolved
Condition: Damaged By Earlier Event
Due 15 August 2014
Resolved 30 July 2014
Resolution: Switch replaced during inspection process.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 July 2014 Resolved
Thermal Fluid Heater emergency Light not operational.
Condition: Damaged By Earlier Event
Due 15 August 2014
Resolved 30 July 2014
Resolution: Corrected during inspection process.

Casualty record · 3

9 March 2014Routine · role: Moored/Anchored in Vicinity of Primary Subject · 1 injured · activity 4813466
15 January 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5808156
9 July 2022Routine · role: Involved in a Marine Casualty · activity 7577570