Records from 1992 to 2026. Most recent: inspection, 15 January 2026.
Inspection history · 56
15 January 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8297102
2 November 2023
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7819085
28 March 2023
Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7658398
4 March 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7416680
12 January 2022
Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7379592
12 January 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7123556
28 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6938956
20 September 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6816471
27 June 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6727935
22 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6630789
11 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6624408
24 October 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6061952
14 January 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5798422
22 December 2015
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5786088
19 August 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5225779
15 October 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5009639
16 September 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4997395
7 November 2012
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4480284
19 September 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4446005
19 September 2012
MTSA Verification · Examination of Repairs · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4446648
24 February 2012
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4252005
23 February 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4250012
2 November 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4181166
10 March 2011
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3961255
28 January 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3936396
27 January 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3934591
22 September 2009
MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3601170
2 January 2009
Administration
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3387678
7 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3369190
24 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3215359
24 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3225132
20 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2859775
12 August 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2163861
9 June 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2095906
4 February 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2001638
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973229
7 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1484827
13 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1485972
7 September 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 93837
27 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1765778
3 June 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108859
28 May 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 179428
1 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 187212
27 November 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 188299
20 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 455788
19 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273887
4 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273281
11 September 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 40594
24 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 75392
23 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418486
12 May 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 34201
14 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 22496
10 February 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 134792
2 June 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 473388
20 October 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 32289
30 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67180
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2022
Resolved
Vessel's starboard shaft seal was excessively leaking.
(approx. 1 gallon a minute into engine room bilge)
Vessel is required to submit report from TPO that all permanent repairs are to their satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2022
Resolved 22 January 2022
Resolution: Reviewed TPO report of attending ABS surveyor attesting to the correction and testing of the leaking shaft seals by ships crew. All permanent repairs are to TPO satisfaction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 January 2022
Resolved
Remote fuel shutoff valves installed were not actuating when tested. After troubleshooting crew was able to acuate both shutoff valves and secure fuel to machinery.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 January 2022
Resolved 18 January 2022
Resolution: After trouble shooting crew was able to actuate both shutoff valves and secure fuel to machinery.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 January 2022
Resolved
Vessel's port and starboard winch's had cable runs that are open from main deck to the engine room allowing for free communication of water intrusion.
Vessel is required to submit report from TPO that all permanent repairs are to their stisfaction.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 27 January 2022
Resolution: Closure devises for hull penetration were installed on vessel's port and starboard winch's
wires from main deck to engine room to avoid water to enter the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 January 2022
Resolved
Two rail stanchions were observered broken across from the entrance to the engine room port and starboard side. Another rail stanchion on the port quarter was severely wasted and not providing protection for crew members astern.
Vessel is required to submit report from TPO that all permanent repairs are to their stisfaction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 27 January 2022
Resolution: broken rail stanchions across from the the entrance to the engine
room port and starboard side were repaired. The other rail stanchions found severely wasted on the port quarter were also repaired for
protection for crew members astern.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 January 2021
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Vessel's installed bilge pump could not dewater the vessel without significant time and effort to prime the pump. Demonstrate the vessel's installed bilge pump can properly dewater the vessel in case of an emergency situation to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2021
Resolved 22 March 2021
Resolution: Recieved Statement of fact and Survey after Construction documents from TPO.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 January 2021
Resolved
Alarms must be visible and audible at each operating station. Vessel did not have visual at operating station. Install an alarm that is capable of providing audible and visual alarm at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2021
Resolved 22 April 2021
Resolution: Witnessed satisfactory test of alarms.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 January 2021
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Vessel's current fuel shutoff configuration unsafe and prone to failure. Reconfigure fuel shutoff arrangement that prevents a potential failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2021
Resolution: New fuel shutoff configuration installed and satisfactorily working.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 September 2012
Resolved
Port MDE exhaust manifold gasket is blown and allowing coolant to seep into bilge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 September 2012
Resolved 21 September 2012
Resolution: technicians replaced gasket and manifold.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 September 2012
Resolved
supply hose is ruptured allowing for small amount of fluid to leak into bilge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 September 2012
Resolved 19 September 2012
Resolution: replaced hose
Stability › Unintentional Flooding › General
Issued 19 September 2012
Resolved
Shaft packing on starboard shaft is leaking approximately 1 gpm into bilge which caused bilge high level alarm to energise.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 September 2012
Resolved 19 September 2012
Resolution: Technician removed all packing and replaced using proper procedures. Training of proper installation procedures was conducted by Operators Port Captain to everyone available at fleeting. Tested shaft on load, test satisfactory to marine inspector.
Lifesaving › Buoyant Apparatus › Approval
Issued 4 January 2000
Resolved
VESSEL MISSING BUOY LIFE RING ONBOARD.
Condition: Unknown
Due 13 November 2006
Resolved 13 November 2006
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 4 January 2000
Resolved
NAME OF VESSEL NOT DISPLAYED ON THE BOW.
Condition: Unknown
Due 10 January 2000
Resolved 13 November 2006
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 23 July 1998
Resolved
NAVIGATION LIGHTS NOT FITTED WITH BLACK SCREENS.
Condition: Unknown
Due 23 July 1998
Resolved 9 November 2006
Lifesaving › Buoyant Apparatus › Approval
Issued 23 July 1998
Resolved
RING BUOYS ON BOARD VESSEL ARE BOTH WORN AND NONSERVICEABLE.
Condition: Unknown
Due 23 July 1998
Resolved 9 November 2006